At least 685 records · Page 38

Agni: Coupling Model Analysis Tools and High-Performance Subsurface Flow and Transport Simulators for Risk and Performance Assessments

Agni is open source /community /multi platform framework for model-based analyses (SA, UQ, PE, RA, DS). Agni can be applied independently from other Advanced Simulation Capability for Environmental Management (ASCEM) modules. Agni will be available as Mercurial repository (hg clone https://akuna.labworks.org/hg/Platform) including source code, manual, test and verification examples.

COMPUTER CODES↗

GW100: Comparison of Methods and Accuracy of Results Obtained with the WEST Code

The reproducibility of calculations carried out within many-body perturbation theory at the G(0)W(0) level is assessed for 100 closed shell molecules and compared to that of density functional theory. We consider vertical ionization potentials (VIP) and electron affinities (VEA) obtained with five different codes: BerkeleyGW, FHI-aims, TURBOMOLE, VASP, and WEST. We review the approximations and parameters that control the accuracy of G(0)W(0) results in each code, and we discuss in detail the effect of extrapolation techniques for the parameters entering the WEST code. Differences between the VIP and VEA computed with the various codes are within similar to 60 and similar to 420 meV, respectively, which is up to four times larger than in the case of the best results obtained with DFT codes. Vertical ionization potentials are validated against experiment and CCSD(T) quantum chemistry results showing a mean absolute relative error of similar to 4% for data obtained with WEST. Our analysis of the differences between localized orbitals and plane-wave implementations points out molecules containing Cu, I, Ga, and Xe as major sources of discrepancies, which call for a re-evaluation of the pseudopotentials used for these systems in G(0)W(0) calculations.

Govoni, Marco↗

Spectral energy distribution analysis of class I and class II FU Orionis stars

FU Orionis stars (FUors) are eruptive pre-main sequence objects thought to represent quasi-periodic or recurring stages of enhanced accretion during the low-mass star-forming process. We characterize the sample of known and candidate FUors in a homogeneous and consistent way, deriving stellar and circumstellar parameters for each object. We emphasize the analysis in those parameters that are supposed to vary during the FUor stage. We modeled the spectral energy distributions of 24 of the 26 currently known FUors, using the radiative transfer code of Whitney et al. We compare our models with those obtained by Robitaille et al. for Taurus class II and I sources in quiescence periods by calculating the cumulative distribution of the different parameters. FUors have more massive disks: we find that ∼80% of the disks in FUors are more massive than any Taurus class II and I sources in the sample. Median values for the disk mass accretion rates are ∼10{sup –7} M {sub ☉} yr{sup –1} versus ∼10{sup –5} M {sub ☉} yr{sup –1} for standard young stellar objects (YSOs) and FUors, respectively. While the distributions of envelope mass accretion rates for class I FUors and standard class I objects are similar, FUors, on average, have higher envelope mass accretion rates than standard class II and class I sources. Most FUors (∼70%) have envelope mass accretion rates above 10{sup –7} M {sub ☉} yr{sup –1}. In contrast, 60% of the classical YSO sample has an accretion rate below this value. Our results support the current scenario in which changes experimented by the circumstellar disk explain the observed properties of these stars. However, the increase in the disk mass accretion rate is smaller than theoretically predicted, although in good agreement with previous determinations.

79 ASTRONOMY AND ASTROPHYSICS↗

Interpretation of Lyman opacity measurements in JET with the ITER-like wall using a particle balance approach

Recent measurements of the Ly β /D α ratio in the JET ITER-like wall (ILW) divertor show comparatively more pronounced Ly β reabsorption relative to previous results in JET with the carbon wall (JET-C). At the outer horizontal target ion current rollover point a Ly β reabsorption rate of 60% is measured, increasing to 80% in more pronounced detachment, implying a Ly α reabsorption rate of 90%–98%. The radially resolved Ly β /D α measurements are used to constrain Lyman opacity corrections to atomic rate coefficients using the population escape factor technique in order to capture the local changes to the excited state population structure in the high Lyman opacity regions at and outboard of the outer strike point. To check the self-consistency of the Lyman opacity measurements, a detailed spectroscopic interpretation of the outer divertor particle balance is presented, in which the impact of opacity corrections to the Ly α inverse photon efficiency coefficients is assessed. A five-fold deficit in the estimated D + source rate obtained with optically thin plasma assumptions is reconciled once the opacity corrections are factored into the Ly α photon rate to ionization rate conversion. The experiment results are reproduced in EDGE2D-EIRENE density scan simulations in which an imposed ad hoc Lyman reabsorption rate is recovered spectroscopically using synthetic measurements, and a similar shortfall in the D + source rate estimates is reconciled using Lyman opacity corrected atomic data. The model limitations prevent a more detailed self-consistent analysis of the Lyman opacity impact on divertor parameters and detachment evolution, and hence motivate renewed efforts to re-establish routine exploitation of the photon transport modelling capabilities in the EIRENE code package. Lyman opacity corrections to atomic data coefficients are necessary for spectroscopic interpretation of the JET-ILW divertor plasma, with significant influence on the divertor plasma also a likely consequence of the presence of strong Ly α reabsorption. Finally, a scan of auxiliary heating powers spanning L-mode and H-mode conditions reveals a strong correlation of the measured Ly β opacity with the outer target temperature, suggesting new possibilities for using Lyman opacity measurements in establishing detachment scalings.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Monte Carlo Shielding Analysis Capabilities with MAVRIC

Monte Carlo shielding analysis capabilities in SCALE 6 are centered on the CADIS methodology Consistent Adjoint Driven Importance Sampling. CADIS is used to create an importance map for space/energy weight windows as well as a biased source distribution. New to SCALE 6 are the Monaco functional module, a multi-group fixed-source Monte Carlo transport code, and the MAVRIC sequence (Monaco with Automated Variance Reduction Using Importance Calculations). MAVRIC uses the Denovo code (also new to SCALE 6) to compute coarse-mesh discrete ordinates solutions which are used by CADIS to form an importance map and biased source distribution for the Monaco Monte Carlo code. MAVRIC allows the user to optimize the Monaco calculation for a specify tally using the CADIS method with little extra input compared to a standard Monte Carlo calculation. When computing several tallies at once or a mesh tally over a large volume of space, an extension of the CADIS method called FW-CADIS can be used to help the Monte Carlo simulation spread particles over phase space to get more uniform relative uncertainties.

99 GENERAL AND MISCELLANEOUS↗

Assessment of the MACCS Code Applicability for Nearfield Consequence Analysis

Three codes are used for comparisons in this report to evaluate the adequacy of MACCS in the nearfield, AERMOD, ARCON96 and QUIC. Test cases were developed to give a broad range of weather conditions, building dimensions and plume buoyancy. Based on the comparisons of MACCS with AERMOD, ARCON96 and QUIC across the test cases, the following observations are made: MACCS calculations configured with point-source, ground-level, nonbuoyant plumes provide nearfield results that bound the centerline, ground-level air concentrations from AERMOD, ARCON96, and QUIC. MACCS calculations with ground-level, nonbuoyant plumes that include the effects of the building wake (area source) provide nearfield results that bound the results from AERMOD and QUIC and the results from ARCON96 at distances >250 m. If using a point-source is too conservative and it is desired to bound the results from all three codes, another alternative is to use area source parameters in MACCS that are less than the standard values, i.e., an area source intermediate between the standard recommendation and a point source. All these options provide results from MACCS that are bounding for the test cases evaluated. Based on these observations, it appears that MACCS is adequate for use in nearfield calculations, given the correct parameterization.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Impact of Dutch nuclear fuel cycle scenarios on radionuclide inventory intended for disposal - 15201

One of the main subjects of Dutch five-year research program into geological disposal of radioactive waste, OPERA, is the post-closure radiological safety assessment. Reliable estimates of the radionuclide inventory and matrix composition are an important input for the safety assessment. The amounts and categories of waste foreseen to be disposed in 2130 the Netherlands have been compiled by the Dutch waste management organisation COVRA. Additionally, NRG has made a characterisation of the waste (radionuclides and matrix). This reference inventory is based on the Dutch base nuclear energy scenario of operating the Dutch single reactor, the Borssele NPP, until its presently scheduled shut-down in 2033. However, changes in the presently adopted nuclear fuel cycle strategy in the Netherlands may impact both the quantities of generated radioactive waste and its composition, and therefore the source term of the radiological safety assessment. To get a grip on this uncertainty a set of alternative future fuel cycle scenarios in the Netherlands, which are in compliance with scenarios formulated in the Dutch vision documents, has been considered and evaluated. The scenarios have been analysed with the computer code DANESS, 'Dynamic Analysis of Nuclear Energy System Strategies'. The result of the DANESS analyses concerns the amount and type of the radioactive waste to be finally disposed in a deep geological repository. This also includes the inventories of the individual radionuclides that are relevant for the post-closure safety assessment to be performed in a subsequent stage of the OPERA program. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Time-Dependent Sensitivity Analysis of OECD Benchmark using BISON and RAVEN

Developments in uncertainty quantification for nuclear simulations have decreased the computational cost required to perform accurate sensitivity analysis. This work demonstrates implementation of these methods in the RAVEN framework, allowing for time-dependent sensitivity analysis. By demonstration we consider an OECD benchmark case. We propagate uncertainties using RAVEN operating on the BISON fuels performance code. We then consider the time-evolution of output response sensitivity to uncertain inputs. We perform sensitivity analysis using time-based stochastic collocation for generalized polynomial chaos (SCgPC) and high-dimension model reduction (HDMR). While uncertainty quantification applied to end-of-cycle statistics is useful, we demonstrate that dominant sources of uncertainty for figures of merit may fluctuate throughout the simulation. Time-dependent sensitivity analysis allows more insight on key design parameters for fuel. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

{sup 103}Pd strings: Monte Carlo assessment of a new approach to brachytherapy source design

Purpose: A new type of{sup 103}Pd source (CivaString and CivaThin by CivaTech Oncology, Inc.) is examined. The source contains {sup 103}Pd and Au radio-opaque marker(s), all contained within low-Z{sub eff} organic polymers that permit source flexibility. The CivaString source is available in lengths L of 10, 20, 30, 40, 50, and 60 mm, and referred to in the current study as CS10–CS60, respectively. A thinner design, CivaThin, has sources designated as CT10–CT60, respectively. The CivaString and CivaThin sources are 0.85 and 0.60 mm in diameter, respectively. The source design is novel and offers an opportunity to examine its interesting dosimetric properties in comparison to conventional {sup 103}Pd seeds. Methods: The MCNP5 radiation transport code was used to estimate air-kerma rate and dose rate distributions with polar and cylindrical coordinate systems. Doses in water and prostate tissue phantoms were compared to determine differences between the TG-43 formalism and realistic clinical circumstances. The influence of Ti encapsulation and 2.7 keV photons was examined. The accuracy of superposition of dose distributions from shorter sources to create longer source dose distributions was also assessed. Results: The normalized air-kerma rate was not highly dependent onL or the polar angle θ, with results being nearly identical between the CivaString and CivaThin sources for common L. The air-kerma strength was also weakly dependent on L. The uncertainty analysis established a standard uncertainty of 1.3% for the dose-rate constant Λ, where the largest contributors were μ{sub en}/ρ and μ/ρ. The Λ values decreased with increasing L, which was largely explained by differences in solid angle. The radial dose function did not substantially vary among the CivaString and CivaThin sources for r ≥ 1 cm. However, behavior for r < 1 cm indicated that the Au marker(s) shielded radiation for the sources having L = 10, 30, and 50 mm. The 2D anisotropy function exhibited peaks and valleys that corresponded to positions adjacent to {sup 103}Pd wells and Au markers, respectively. Dose distributions of both source types had minimal anisotropy in comparison to conventional {sup 103}Pd seeds. Contributions by 2.7 keV photons comprised ≤0.1% of the dose from all photons at positions farther than 0.13 mm from the polymer source surface. Differences between absorbed dose to water and prostate became more substantial as distance from the sources increased, with prostate dose being about 13% lower for r = 5 cm. Using a cylindrical coordinate system, dose superposition of small length sources to replicate the dose distribution for a long length source proved to be a robust technique; a 2.0% tolerance compared with the reference dose distribution did not exceed 0.1 cm{sup 3} for any of the examined source combinations. Conclusions: By design, the CivaString and CivaThin sources have novel dosimetric characteristics in comparison to Ti-encapsulated{sup 103}Pd seeds. The dosimetric characterization has determined the reasons for these differences through analysis using Monte Carlo-based radiation transport simulations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of a commercial MRI Linac based Monte Carlo dose calculation algorithm with GEANT 4

Purpose: This paper provides a comparison between a fast, commercial, in-patient Monte Carlo dose calculation algorithm (GPUMCD) and GEANT4. It also evaluates the dosimetric impact of the application of an external 1.5 T magnetic field. Methods: A stand-alone version of the Elekta™ GPUMCD algorithm, to be used within the Monaco treatment planning system to model dose for the Elekta™ magnetic resonance imaging (MRI) Linac, was compared against GEANT4 (v10.1). This was done in the presence or absence of a 1.5 T static magnetic field directed orthogonally to the radiation beam axis. Phantoms with material compositions of water, ICRU lung, ICRU compact-bone, and titanium were used for this purpose. Beams with 2 MeV monoenergetic photons as well as a 7 MV histogrammed spectrum representing the MRI Linac spectrum were emitted from a point source using a nominal source-to-surface distance of 142.5 cm. Field sizes ranged from 1.5 × 1.5 to 10 × 10 cm{sup 2}. Dose scoring was performed using a 3D grid comprising 1 mm{sup 3} voxels. The production thresholds were equivalent for both codes. Results were analyzed based upon a voxel by voxel dose difference between the two codes and also using a volumetric gamma analysis. Results: Comparisons were drawn from central axis depth doses, cross beam profiles, and isodose contours. Both in the presence and absence of a 1.5 T static magnetic field the relative differences in doses scored along the beam central axis were less than 1% for the homogeneous water phantom and all results matched within a maximum of ±2% for heterogeneous phantoms. Volumetric gamma analysis indicated that more than 99% of the examined volume passed gamma criteria of 2%—2 mm (dose difference and distance to agreement, respectively). These criteria were chosen because the minimum primary statistical uncertainty in dose scoring voxels was 0.5%. The presence of the magnetic field affects the dose at the interface depending upon the density of the material on either sides of the interface. This effect varies with the field size. For example, at the water-lung interface a 33.94% increase in dose was observed (relative to the D{sub max}), by both GPUMCD and GEANT4 for the field size of 2 × 2 cm{sup 2} (compared to no B-field case), which increased to 47.83% for the field size of 5 × 5 cm{sup 2} in the presence of the magnetic field. Similarly, at the lung-water interface, the dose decreased by 19.21% (relative to D{sub max}) for a field size of 2 × 2 cm{sup 2} and by 30.01% for 5 × 5 cm{sup 2} field size. For more complex combinations of materials the dose deposition also becomes more complex. Conclusions: The GPUMCD algorithm showed good agreement against GEANT4 both in the presence and absence of a 1.5 T external magnetic field. The application of 1.5 T magnetic field significantly alters the dose at the interfaces by either increasing or decreasing the dose depending upon the density of the material on either side of the interfaces.

61 RADIATION PROTECTION AND DOSIMETRY↗

Multiscale Simulations of ALD in Cross Flow Reactors

In this study, we have developed a multiscale simulation code that allows us to study the impact of surface chemistry on the coating of large area substrates with high surface area/high aspect-ratio features. Our code, based on open-source libraries, takes advantage of the ALD surface chemistry to achieve an extremely efficient two-way coupling between reactor and feature length scales, and it can provide simulated quartz crystal microbalance and mass spectrometry data at any point of the reactor. By combining experimental surface characterization with simple analysis of growth profiles in a tubular cross flow reactor, we are able to extract a minimal set of reactions to effectively model the surface chemistry, including the presence of spurious CVD, to evaluate the impact of surface chemistry on the coating of large, high surface area substrates.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

MC21 analysis of the nuclear energy agency Monte Carlo performance benchmark problem

Due to the steadily decreasing cost and wider availability of large scale computing platforms, there is growing interest in the prospects for the use of Monte Carlo for reactor design calculations that are currently performed using few-group diffusion theory or other low-order methods. To facilitate the monitoring of the progress being made toward the goal of practical full-core reactor design calculations using Monte Carlo, a performance benchmark has been developed and made available through the Nuclear Energy Agency. A first analysis of this benchmark using the MC21 Monte Carlo code was reported on in 2010, and several practical difficulties were highlighted. In this paper, a newer version of MC21 that addresses some of these difficulties has been applied to the benchmark. In particular, the confidence-interval-determination method has been improved to eliminate source correlation bias, and a fission-source-weighting method has been implemented to provide a more uniform distribution of statistical uncertainties. In addition, the Forward-Weighted, Consistent-Adjoint-Driven Importance Sampling methodology has been applied to the benchmark problem. Results of several analyses using these methods are presented, as well as results from a very large calculation with statistical uncertainties that approach what is needed for design applications. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Simulation of the cygnus rod-pinch diode using the radiographic chain model

The Cygnus radiographic machine is a relatively compact low-energy (<3 MV) x-ray source with some extremely desirable features for radiographic applications. These features include small spot size critical for high-spatial resolution and high dose in a low energy range. The x-ray source is based on bremsstrahlung production in a small diameter ({approx}0.75 mm) tungsten rod by a high-current ({approx}60 kA) electron beam converging at the tip of the rod. For quantitative analysis of radiographic data, it is essential to determine the bremsstrahlung spectrum accurately. We have used the radiographic chain model that self-consistently models the diode with a two-dimensional particle-in-cell code (Merlin) which links to an electron-photon Monte Carlo code to obtain the spectrum under three different situations. These are: steady state spectrum using a voltage puise of 2.5 MV, time-integrated spectrum using a time-dependent experimental voltage pulse, and inclusion of reflexing electrons at the anode in our particle-in-cell simulation. Detailed electron dynamics have been obtained in our study. Our investigations conclude that the time integrated bremsstrahlung spectrum is significantly softer than that of the steady state. In our latest simulations, we have included the effects of reflexing electrons around the anode rod and found the spectrum to be in better agreement with experimental data.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Efficient analysis routines for single and double peaked Type 2 AGN spectra

Driven by the imminent need to rapidly process and classify millions of AGN spectra drawn from next generation astronomical facilities, we present a spectral fitting routine for Type 2 AGN spectra optimized for high volume processing, using the quasar spectral fitting library (qsfit). We analyse an optically selected sample of 813 luminous Type 2 AGN spectra at z < 0.83 from the Sloan Digital Sky Survey (SDSS) to qualify its performance. We report a median narrow line H α/H β Balmer decrement of 4.5 ± 0.8, alluding to the presence of dust in the narrow line region (NLR). We publish a specialized QSFIT fitting routine for high signal-to-noise ratio spectra and general fitting routine for double peaked Type 2 AGN spectra applied on a subsample of 45 spectra from our parent sample. We report a median red and blue peak velocity separation of 390 ± 60 kms −1 . No trend is found for red or blue peaks to exhibit systematically different luminosity or ionization properties. Emission line diagnostics show that the double peaks in all sources are illuminated by an AGN-powered ionizing continuum. Finally, we examine the morphology of host galaxies of our double peaked sample. We find double peaked Type 2 AGN reside in merging systems at a comparable frequency to single peaked AGN. This suggests that the double peaked AGN phenomenon is likely to have a bi-conical outflow origin in the majority of cases. We publicly release the code used for spectral analysis and produced catalogues used in this work.

79 ASTRONOMY AND ASTROPHYSICS↗

DO WE REALLY KNOW THE DUST? SYSTEMATICS AND UNCERTAINTIES OF THE MID-INFRARED SPECTRAL ANALYSIS METHODS

The spectral region around 10 {mu}m, showing prominent emission bands from various dust species is commonly used for the evaluation of the chemical composition of protoplanetary dust. Different methods of analysis have been proposed for this purpose, but so far, no comparative test has been performed to test the validity of their assumptions. In this paper, we evaluate how good the various methods are in deriving the chemical composition of dust grains from infrared spectroscopy. Synthetic spectra of disk models with different geometries and central sources were calculated, using a two-dimensional radiative transfer code. These spectra were then fitted in a blind test by four spectral decomposition methods. We studied the effect of disk structure (flared versus flat), inclination angle, size of an inner disk hole, and stellar luminosity on the fitted chemical composition. Our results show that the dust parameters obtained by all methods deviate systematically from the input data of the synthetic spectra. The dust composition fitted by the new two-layer temperature distribution method, described in this paper, differs the least from the input dust composition and the results show the weakest systematic effects. The reason for the deviations of the results given by the previously used methods lies in their simplifying assumptions. Due to the radial extent of the 10 {mu}m emitting region there is dust at different temperatures contributing to the flux in the silicate feature. Therefore, the assumption of a single averaged grain temperature can be a strong limitation of the previously used methods. The continuum below the feature can consist of multiple components (e.g., star, inner rim, and disk midplane), which cannot simply be described by a Planck function at a single temperature. In addition, the optically thin emission of 'featureless' grains (e.g., carbon in the considered wavelength range) produces a degeneracy in the models with the optically thick emission of the disk. The effect of different noise levels on the results has also been tested. We find that for a signal-to-noise ratio (S/N) of 100 one can expect an absolute uncertainty in the value of the crystallinity of about 11% using ground-based observations (8-13 {mu}m). For space-based observations (7-17 {mu}m) the expected uncertainty is about 5% for the same S/N value. Moreover, the average value of the estimated crystallinity increases toward lower S/N in general. On the basis of our results, we propose a recipe for the analysis and interpretation of dust spectroscopy data in the mid-infrared which should be especially valuable for analyzing Spitzer spectroscopy data and ground-based infrared spectroscopy data in the 10 {mu}m window.

99 GENERAL AND MISCELLANEOUS↗

On the prediction of horizontal bubbly flows using the interfacial area transport equation

To solve the two-fluid model utilized in current nuclear reactor system analysis codes, the interfacial area concentration (a i) is estimated through flow regime dependent correlations that rely on static regime transition criteria. This approach does not capture the continuous evolution of the interfacial structures, and thus, it can pose numerical issues near the transition boundaries. The interfacial area transport equation (IATE) can help address these shortcomings by providing a dynamic prediction of a a{sub i} through mechanistic source and sink terms that account for bubble coalescence and breakup. Most of the previous work for this approach has focused on vertical two-phase flow. However, relatively few studies have been performed for horizontal two-phase flows, where buoyancy strongly affects the phase distribution. To develop a one-dimensional, area-averaged form of the IATE for adiabatic, horizontal bubbly flows the following considerations are necessary: (1) pressure drop estimation, (2) bubble velocity/void fraction estimation, (3) determination of bubble interaction mechanisms, and (4) treatment of the asymmetric phase distribution. In the current work, treatment of the asymmetric phase distribution is presented. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Performance gain with low-enriched fuel and optimized use of neutrons

The most challenging type of reactors to convert to low-enriched fuel are high-flux research reactors, which, along with some spallation sources, are the most important neutron sources for modern neutron scattering experiments. Advanced Monte-Carlo computer codes are now available that make it possible to track neutrons from the reactor core, through neutron guides, to instruments and detectors. These 'virtual experiments' allow optimizing the performance of a research facility as a whole instead of the reactor alone. This article briefly reviews performance gains obtained for high-flux reactors during previous facility-upgrades. The Monte-Carlo code VITESS is used to compare results for typical neutron scattering experiments using obsolete versus state-of-the-art technologies. The analysis shows that performance gains due to instrument upgrades or neutron guide renewals dwarf potential neutron flux losses due to conversion to low-enriched fuel. Combined convert-and-upgrade strategies therefore offer unique opportunities for reactor operators and neutron instrument groups to significantly improve the overall performance of research facilities. (author)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Overview of the Multiscale Epidemiologic/Economic Simulation and Analysis (MESA) Decision Support System

The Multiscale Epidemiologic/Economic Simulation and Analysis (MESA) Decision Support System (DSS) is the product of investments that began in FY05 by the Department of Homeland Security (DHS) Science and Technology Directorate and continue today with joint funding by both DHS and the US Department of Agriculture (USDA). The DSS consists of a coupled epidemiologic/economic model, a standalone graphical user interface (GUI) that supports both model setup and post-analysis, and a Scenario Bank archive to store all content related to foreign animal disease (FAD) studies. The MESA epi model is an object-oriented, agent-based, stochastic, spatio-temporal simulator that parametrically models FAD outbreaks and response strategies from initial disease introduction to conclusion over local, regional, and national scales. Through its output database, the epi model couples to an economic model that calculates farm-level impacts from animal infections, responsive control strategies and loss of trade. The MESA architecture contains a variety of internal models that implement the major components of the epi simulation, including disease introduction, intra-herd spread, inter-herd spread (direct and indirect), detection, and various control strategies (movement restrictions, culling, vaccination) in a highly configurable and extensible fashion. MESA development was originally focused to support investigations into the economic and agricultural industry impacts associated with Foot-and-Mouth Disease (FMD outbreaks). However, it has been adapted to other FADs such has Highly Pathogenic Avian Influenza (HPAI), Classical Swine Fever (CSF) and Exotic Newcastle Disease (END). The MESA model is highly parameterized and employs an extensible architecture that permits straightforward addition of new component models (e.g., alternative disease spread approaches) when necessary. Since its inception, MESA has been developed with a requirement to enable simulation of the very large scale, nationwide disease outbreaks that are of special interest to DHS. MESA has been developed at Lawrence Livermore National Laboratory (LLNL) and has benefited from the world-class experience in supercomputing application development held by LLNL staff as well as the best-in-class high performance computing infrastructure in place at LLNL. MESA incorporates novel architectural features that permit it to make efficient use of available compute cycles by dynamically increasing the fidelity of the simulation in spatial (geopolitical) regions where relevant activity is occurring and keeping other regions aggregated into a computationally simpler representation. In addition to the MESA epi and economic models, the MESA DSS incorporates other key components. Integral to the parametric approach MESA employs to setup and define disease outbreak scenarios is a GUI that enables the MESA user to efficiently manage the thousands of parameters required by the simulator. The GUI provides individual parameter editors for groups of variables that support a common high level function, such as disease introduction, spread, control strategies, etc. It also provides a capability to browse through multiple study projects and develop n-additional outbreak scenarios per project through successive refinement of existing scenarios. Finally, the MESA GUI links post-processing applications that permit extraction of key data from MESA raw output, generation of spreadsheets, and geospatial mapping of simulation results. The MESA GUI is a standalone application that normally runs on the user's desktop, although its Java source code is portable and can execute under virtually any modern operating system. The final major component of the MESA DSS is the Scenario Bank, which is a web-served archive of unclassified FAD study content. The Scenario Bank implements a hierarchy of spaces, structured primarily along organizational lines (e.g., 'USDA', 'LLNL', etc), that permits participants to store simulator inputs, outputs, analysis results, reports, etc. and explicitly control who among Bank users may access them. Documents can be shared within organizations or across organizations at the owner's discretion. The Scenario Bank is intended to be the system of record for USDA and DHS sponsored FAD study efforts and as such will archive content from a variety of models employed by USDA and DHS-sponsored researchers and analysts.

59 BASIC BIOLOGICAL SCIENCES↗