Search NASA⌕ Search

SEARCH · Search NASA

Results for “Building data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Sensor Data Management, Validation, Correction, and Provenance for Building Technologies

Oak Ridge National Laboratory (ORNL) conducts research on technologies that use a wide range of sensors to develop and characterize building energy performance. The management of high-resolution sensor data, analysis, and tracing lineage of such activities is challenging. Missing or corrupt data due to sensor failure, fouling, drifting, calibration error, or data logger failure is another issue. This paper focuses on sensor data management, validation, correction, and provenance to combat these issues, ensuring complete and accurate sensor datasets for building technologies applications and research. The design and development of two integrated software products are discussed: Sensor Data Validation and Correction (SensorDVC) and the Provenance Data Management System (ProvDMS) platform.

Data management↗

Do energy costs really affect commercial mortgage default risk? New results and implications for energy efficiency investments [PowerPoint]

This paper presents new results on the link between energy factors and commercial mortgage default. First, we summarize results from an empirical analysis of the impact of source energy use intensity (EUI) and electricity prices on mortgage default. We used a unique data set that merges building-level energy use data from city benchmarking ordinances and financial data for commercial mortgages on the same buildings. We found that building source EUI and electricity price are statistically and economically associated with commercial mortgage defaults. Next, we present five case studies on the impact of energy use and price variations on default risk: three office buildings, a hotel, and a multi-family residential building. We use the empirical model coefficients to compute the default risk impacts due to variations in source EUI and electricity price over the course of the mortgage term. We found that variations in source EUI could raise or lower the default rates in these properties by between 5% and 40%, depending on the property type and geography. Electricity pricing has an even greater effect – roughly 60% change in default rate in the Denver area and nearly 90% in northern California. Finally, we propose an energy risk score that lenders can use to assess energy risk and inform mortgage terms. The score is being developed and piloted in collaboration with three mortgage lenders. We conclude with implications of this score as a market signal and mechanism for incentivizing energy efficiency investments through the commercial mortgage channel.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Cybersecurity Testbed for Smart Buildings

Smart buildings are equipped with a plethora of cyber-physical systems, such as Internet of Things (IoT) devices and building automation systems. These devices, especially in commercial buildings, use legacy communications and hardware that were not designed with cybersecurity in mind. With increasing cyber threats in recent years, smart buildings have become an increasing target for attacks, but not enough published data are available from these incidents to study or replicate the scenarios to defend buildings. As part of the U.S. Department of Energy-funded project focusing on developing the Building Intelligence with Layered Defense Using Security-Constrained Optimization and Security Risk Detection (BUILD-SOS) platform, we developed a cybersecurity test bed for smart buildings. This test bed includes a building simulation tool, virtual devices, emulated operational technology networks, and remote hardware-in-the-loop. Using this test bed, we performed different cyberattacks on the smart building model and collected both physical building data, to understand the impacts on the building, and network data, to aid in separating mechanical faults from cyberattacks during the detection. This test bed is a significant tool in protecting smart buildings from cyberattacks because it can aid in both cybersecurity analysis and the evaluation of other cyberattack detection tools by testing the tools in a secure environment without impacting the building operations.

cyber-physical systems↗

A Cybersecurity Testbed for Smart Buildings

Smart buildings are equipped with a plethora of cyber-physical systems, such as Internet of Things (IoT) devices and building automation systems. These devices, especially in commercial buildings, use legacy communications and hardware that were not designed with cybersecurity in mind. With increasing cyber threats in recent years, smart buildings have become an increasing target for attacks, but not enough published data are available from these incidents to study or replicate the scenarios to defend buildings. As part of the U.S. Department of Energy-funded project focusing on developing the Building Intelligence with Layered Defense Using Security-Constrained Optimization and Security Risk Detection (BUILD-SOS) platform, we developed a cybersecurity test bed for smart buildings. This test bed includes a building simulation tool, virtual devices, emulated operational technology networks, and remote hardware-in-the-loop. Using this test bed, we performed different cyberattacks on the smart building model and collected both physical building data, to understand the impacts on the building, and network data, to aid in separating mechanical faults from cyberattacks during the detection. This test bed is a significant tool in protecting smart buildings from cyberattacks because they can aid in both cybersecurity analysis and the evaluation of cyberattack detection tools by testing the tools in a secure environment without impacting the building operations.

alfalfa↗

Understanding the Effect of Baseline Modeling Implementation Choices on Analysis of Demand Response Performance

Accurate evaluation of the performance of buildings participating in Demand Response (DR) programs is critical to the adoption and improvement of these programs. Typically, we calculate load sheds during DR events by comparing observed electric demand against counterfactual predictions made using statistical baseline models. Many baseline models exist and these models can produce different shed calculations. Moreover, modelers implementing the same baseline model can make different modeling implementation choices, which may affect shed estimates. In this work, using real data, we analyze the effect of different modeling implementation choices on shed predictions. We focused on five issues: weather data source, resolution of data, methods for determining when buildings are occupied, methods for aligning building data with temperature data, and methods for power outage filtering. Results indicate sensitivity to the weather data source and data filtration methods as well as an immediate potential for automation of methods to choose building occupied modes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

UNDERSTANDING FLOW OF ENERGY IN BUILDINGS USING MODAL ANALYSIS METHODOLOGY

It is widely understood that energy storage is the key to integrating variable generators into the grid. It has been proposed that the thermal mass of buildings could be used as a distributed energy storage solution and several researchers are making headway in this problem. However, the inability to easily determine the magnitude of the building’s effective thermal mass, and how the heating ventilation and air conditioning (HVAC) system exchanges thermal energy with it, is a significant challenge to designing systems which utilize this storage mechanism. In this paper we adapt modal analysis methods used in mechanical structures to identify the primary modes of energy transfer among thermal masses in a building. The paper describes the technique using data from an idealized building model. The approach is successfully applied to actual temperature data from a commercial building in downtown Boise, Idaho.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Renewable Energy at NASA's Johnson Space Center

NASA's Johnson Space Center has implemented a great number of renewable energy systems. Renewable energy systems are necessary to research and implement if we humans are expected to continue to grow and thrive on this planet. These systems generate energy using renewable sources - water, wind, sun - things that we will not run out of. Johnson Space Center is helping to pave the way by installing and studying various renewable energy systems. The objective of this report will be to examine the completed renewable energy projects at NASA's Johnson Space Center for a time span of ten years, beginning in 2003 and ending in early 2014. This report will analyze the success of each project based on actual vs. projected savings and actual vs. projected efficiency. Additionally, both positive and negative experiences are documented so that lessons may be learned from past experiences. NASA is incorporating renewable energy wherever it can, including into buildings. According to the 2012 JSC Annual Sustainability Report, there are 321,660 square feet of green building space on JSC's campus. The two projects discussed here are major contributors to that statistic. These buildings were designed to meet various Leadership in Energy and Environmental Design (LEED) Certification criteria. LEED Certified buildings use 30 to 50 percent less energy and water compared to non-LEED buildings. The objectives of this project were to examine data from the renewable energy systems in two of the green buildings onsite - Building 12 and Building 20. In Building 12, data was examined from the solar photovoltaic arrays. In Building 20, data was examined from the solar water heater system. By examining the data from the two buildings, it could be determined if the renewable energy systems are operating efficiently. Objectives In Building 12, the data from the solar photovoltaic arrays shows that the system is continuously collecting energy from the sun, as shown by the graph below. Building 12 has two solar inverters, located on the second floor, that collected the data from the solar photovoltaic arrays. The data displayed here is the total energy produced by the system. These are cumulative amounts, so the last point on the graph shows all of the energy collected from the system since the start of its operation. The data shown here was manually collected from the solar inverters. However, the data is also automatically recorded through EBI. Through analysis of both sets of data it was determined that the EBI data was faulty. For example, from the manually collected data it can be determined that a total of 73 kWh of energy was collected between the dates of 1/16/2014 – 1/22/2014. The EBI data reports that approximately 17800 kWh of energy was collected during the same time frame. Not only does this exceed the time frame examined, but it also exceeds the total energy collected from the start of collection as recorded from the inverters. This leads to the belief that there is a malfunction with the automatic recording of the energy. In Building 20, data was examined from the solar water heater dating back many months and found that the pump for the solar water heater system was not operating properly, as exhibited in the graph shown below. The pump operates on a solar energy system, meaning that it collects energy throughout the day from the sun. Because of this, the system would stop operating shortly after the sun set because of a lack of sunlight. At that point, the graph should show a zero flow rate, but as exhibited in the graph below, that is not the case. It is clearly shown that the pump is continuously operating, even during the night. It was also observed that the majority of the time the pump would not turn on at all, despite good weather conditions. This led to the conclusion that the pump is malfunctioning, and needs to be examined and fixed.

McDowall, Lindsay↗

A method of building of decision trees based on data from wearable device during a rehabilitation of patients with tibia fractures

Nowadays technologies which are used in traumatology are a combination of mechanical, electronic, calculating and programming tools. Relevance of development of mobile applications for an expeditious data processing which are received from medical devices (in particular, wearable devices), and formulation of management decisions increases. Using of a mathematical method of building of decision trees for an assessment of a patient’s health condition using data from a wearable device considers in this article.

97 MATHEMATICS AND COMPUTING↗

The Building Adapter: Automatic Mapping of Commercial Buildings for Scalable Building Analytics

This project creates new solutions for the manual metadata mapping problem: the costly process of creating a match between a building’s sensor data streams and the inputs of a building analytics engine. This goal is achieved by creating and improving techniques for metadata inference: automatically constructing new contextual information for sensing and control points based on the sensor point names and the raw time series values. The objective is to enable vendors to apply building analytics to 90% of buildings with no manual mapping, and to 10% of buildings with a 90% reduction in manual mapping. These targets are set for all types of metadata required by current analytics engines, including type, location, equipment type, and other relationships. The outcome of this project is a suite of solutions to the manual mapping problem collectively called the Building Adapter that allows vendors to apply analytics engines to new buildings at a significantly reduced cost.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Field Demonstration of the Brick Ontology to Scale up the Deployment of ASHRAE Guideline 36 Control Sequences

Many commercial buildings have a vast network of sensors as part of their building automation systems (BAS) that allows opportunities for energy consumption and cost savings by deploying advanced control sequences. However, this resource is often underutilized since BAS are typically programmed with simple control sequences with limited potential to deliver on these opportunities. The recent availability of ASHRAE Guideline 36 (G36) with advanced HVAC control sequences supports control retrofits in existing buildings to unlock much of the savings potential. However, barriers such as the lack of standard naming convention of building assets and data points, proprietary equipment and BAS, and the inherent uniqueness of buildings and their systems prevent building stakeholders from adopting any “plug-and-play” implementation of G36. Instead, control vendors must often undertake the manual and labor-intensive point mapping process to identify a data stream’s functional and spatial relationship within the HVAC system along with other relevant contexts and map it to the new control sequences. The vendor must carry out the point mapping process in each individual building since the mapping is unlikely to port over to another building. Even for the same building, the point mapping process can occur multiple times if various control vendors implement different control retrofits and/or multiple control retrofits happen over the lifecycle of the building. Then, there is the likelihood that G36 control sequences are programmed uniquely to the building, preventing the same implementation from being reused in another. Therefore, this paper presents a field demonstration of how we leveraged the Brick ontology with BACnet, OpenBuildingControl’s Control Description Language (CDL), and open-source support tools to implement scalable and portable advanced building controls. These tools provide standardized semantic descriptions and relationships of the building’s assets and data points (Brick), standardized communication protocol to read from and write to the building’s BAS (BACnet), and standardized code implementations (CDL) of standardized advanced control strategies (G36). We implemented G36’s hot water supply temperature setpoint reset in a Berkeley, CA building for this field demonstration. This field demonstration aims to show how integrating these tools may streamline the deployment of advanced control sequences such as G36 in a consistent manner regardless of differences found across buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Data-Driven Approach to Nation-Scale Building Energy Modeling

In 2019, 125 million U.S. residential and commercial buildings consumed $412 billion in energy bills. These buildings currently consume 40% of the nation's primary energy, 73% of electricity, 80% of energy during peak electric grid use, and responsible for 39% of greenhouse gas emissions [14]. Urban-scale building energy modeling has grown significantly in the past decade, allowing individual campuses or communities of buildings to be modeled, simulated, and cost-effective solutions for intelligent management to be identified and implemented. While traditionally limited to individual counties and usually less than 2,000 buildings, the Automatic Building Energy Modeling (AutoBEM) soft-ware suite has been developed to process unconventional, nation-scale data sources to generate unique OpenStudio and EnergyPlus models of each building. Through the use of High Performance Computing (HPC) resources, every U.S. building has been simulated. This paper showcases the data layout, node partitioning, algorithmic approaches, and analytic results that were used to create, share, and analyze 124.4 million U.S. building models.

Berres, Andy↗

BrickQA: Bridging the Semantic Gap in Building Operations with Dynamic Graph Exploration

While standardized ontologies like the Brick schema address data heterogeneity in Building Automation Systems (BAS), accessing this semantic data remains a challenge as domain experts often lack the expertise to formulate complex SPARQL queries. To bridge this gap, we present BrickQA, a Large Language Model (LLM)-based framework that translates natural language into executable SPARQL queries through structured query decomposition, dynamic schema exploration, and inline validation. BrickQA utilizes an iterative reasoning agent to actively navigate graph topology through dynamic exploration actions without requiring exhaustive context injection or model fine-tuning. This approach effectively mitigates hallucinations, particularly in large-scale building knowledge graphs. Empirical evaluation on BuildingQA, a standardized benchmark, demonstrates that BrickQA significantly outperforms ReAct baselines, delivering a 0.291–0.355 absolute F1 improvement while achieving 3 × –12.7 × higher token cost-efficiency. Beyond these metrics, the framework maintains structural fidelity across heterogeneous buildings and remains resilient to ambiguous queries without requiring site-specific fine-tuning. Furthermore, a case study on operational analytics validates the framework’s capability to handle temporal and aggregation constraints, effectively transforming abstract semantic models into actionable facility management insights.1

Ko, Yun-Dam↗

Data-driven evaluation of HVAC operation and savings in commercial buildings

Commercial buildings consumed 36% of electricity, or 1.35 trillion kWh, in the United States in 2017, and almost 30% of this energy was wasted. Much of this loss can be attributed to inefficient heating ventilation and air con­ditioning (HVAC) systems. By improving the operational conditions of HVAC, significant savings can be achieved. However, most buildings and building equipment do not use costly sub-meters to monitor and address performance issues, and on-site auditing can be expensive and insufficient. Alternatively in this study, we propose a data-driven method to identify savings opportunities using only whole building meter data and without setting foot in the building. For this purpose, we introduced two algorithms that virtually quantify the value of a thermostat setpoint setback and HVAC rescheduling. Additionally, we developed novel methods for detecting occupancy patterns and quantifying the baseload of the HVAC operation. Using a clustering algorithm, we identified those buildings for which HVAC savings was significant and further categorized the buildings based on their potential for savings. A population study of over 432 commercial buildings demonstrated a median percentage energy savings of 1.6% from a baseload reduction and 2.1% from HVAC rescheduling. Additionally, results indicate that retail buildings have the highest potential for savings among the building types studied.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A distributed decision framework for building clusters with different heterogeneity settings

In the past few decades, extensive research has been conducted to develop operation and control strategy for smart buildings with the purpose of reducing energy consumption. Besides studying on single building, it is envisioned that the next generation buildings can freely connect with one another to share energy and exchange information in the context of smart grid. It was demonstrated that a network of connected buildings (aka building clusters) can significantly reduce primary energy consumption, improve environmental sustainability and building s resilience capability. However, an analytic tool to determine which type of buildings should form a cluster and what is the impact of building clusters heterogeneity based on energy profile to the energy performance of building clusters is missing. To bridge these research gaps, we propose a self-organizing map clustering algorithm to divide multiple buildings to different clusters based on their energy profiles, and a homogeneity index to evaluate the heterogeneity of different building clusters configurations. In addition, a bi-level distributed decision model is developed to study the energy sharing in the building clusters. To demonstrate the effectiveness of the proposed clustering algorithm and decision model, we employ a dataset including monthly energy consumption data for 30 buildings where the data is collected every 15 min. It is demonstrated that the proposed decision model can achieve at least 13% cost savings for building clusters. Furthermore, the results show that the heterogeneity of energy profile is an important factor to select battery and renewable energy source for building clusters, and the shared battery and renewable energy are preferred for more heterogeneous building clusters.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building Agent™ Software (BA) [SWRs 12-05 and 17-21]

Energy interfaces provide a new level of motivational information. Many studies have reported energy savings after dashboards for operators are installed, but these provide little actionable information to the occupant and the occupant cannot report individual comfort. The Building Agent™ (BA), in development at the National Renewable Energy Laboratory (NREL), provides an interface for the occupant to converse with the building control system and aims to actively engage and affect occupant behavior to achieve positive energy outcomes. Energy savings achieved via occupant behavioral changes could be as high as 25%, and could rival savings achieved by technological measures. For example, energy audits often show that more than 50% of the energy used in a building is consumed at night. Occupants leaving equipment and lighting on after they leave work is a large contributing factor. Similar savings opportunities have been identified when occupants were away from their desks 50% of the time, while most of their computers, lights, and other equipment remained powered on. Building Agent aims to create cohesion between building automation system (BAS) data, local measurements, and occupant feedback to provide visualizations, empowering occupants and building engineers to take diagnostic, proactive, energy-saving, and comfort-improving actions. The multilayer BA architecture consists of central server, measurement, and distributed application layers. The server layer aggregates global and localized measurements with occupant feedback to correlate perceived comfort with actual data throughout the building. The measurement layer complements BAS data with localized, environmental condition measurements at workstations. The application layer provides a bidirectional communications mechanism between the building and the occupants that accepts comfort feedback and provides energy performance information. The interface layer also uses three displays to influence building energy use: empathetic and personalized gauges, graphical data, and competitive rankings. Building Agent was implemented at NREL in the Research Support Facility (RSF), a LEED Platinum and Net Zero office building, which has received many awards. The constant feedback from occupants has enabled BA to better enhance the BAS data controls. Continued work is being done on BA to increase visualization of data and enhanced the user experience.

Long, Nicholas↗

Accessing Wi-Fi Data for Occupancy Sensing

A key issue for saving energy in buildings is to assure that delivery of energy services matches building occupancy as closely as possible, to assure that energy is not wasted providing the services to empty rooms or buildings, and to assure that needed services are provided during all times when desired. Accomplishing this to date has been significantly hampered by a lack of inexpensive mechanisms to obtain and use building-wide and more granular data about occupancy. In recent years, the concept of inferential (or implicit) sensing has been proposed and explored to use data from IT systems that already exists in most buildings, to obtain data that are not perfect, but are nearly free to obtain. Past work by LBNL and others has primarily demonstrated the principle and potential for this, with a primary focus on data from Wi-Fi networks as the best near-term opportunity for inferential sensing from IT networks. This is due to its near-ubiquity, ease of explanation to many audiences, relative uniformness in deployment, low latency of detection, clear ways to mitigate privacy and security, and other benefits (Price et al., 2015). While the potential and value are clear, researchers or building managers who want to obtain the data lack a source of information to understand what data might exist, what devices may have it, and what mechanisms are available to obtain the data. The purpose of this report is to fill that gap. The report begins with a review of institutional issues in collecting such data, including very real concerns about privacy and IT security. It then describes the various system architectures used in Wi-Fi systems in commercial buildings today, and a variety of mechanisms that can be used to obtain information from them, including examples of how to use them, and sample output. Next is a summary of how to use such data for several different purposes, from retrospective analysis to dynamic building operation, and a conclusion. An appendix provides additional detail on specific mechanisms available from major equipment manufacturers. The mechanisms specified in this report can be used by building owners and operators to confirm proper operation and uncover any issues or unexpected conditions as a resource for building owners and researchers interesting in utilizing inferential sensing data.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗