Search NASA⌕ Search

SEARCH · Search NASA

Results for “CONVENTIONAL RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Interrater Reliability of the Categorization of Late Radiographic Changes After Lung Stereotactic Body Radiation Therapy

Purpose: Radiographic changes after lung stereotactic body radiation therapy (SBRT) have been categorized into 4 groups: modified conventional pattern (A), mass-like fibrosis; (B), scar-like fibrosis (C), and no evidence of increased density (D). The purpose of this study was to assess the interrater reliability of this categorization system in patients with early-stage non-small cell lung cancer (NSCLC). Methods and Materials: Seventy-seven patients were included in this study, all treated with SBRT for early-stage (T1/2) NSCLC at a single institution, with a minimum follow-up of 6 months. Six experienced clinicians familiar with post-SBRT radiographic changes scored the serial posttreatment CT images independently in a blinded fashion. The proportion of patients categorized as A, B, C, or D at each interval was determined. Krippendorff's alpha (KA), Multirater kappa (M-kappa), and Gwet's AC1 (AC1) scores were used to establish interrater reliability. A leave-one-out analysis was performed to demonstrate the variability among raters. Interrater agreement of the first and last 20 patients scored was calculated to explore whether a training effect existed. Results: The number of ratings ranged from 450 at 6 months to 84 at 48 months of follow-up. The proportion of patients in each category was as follows: A, 45%; B, 16%; C, 13%; and D, 26%. KA and M-kappa ranged from 0.17 to 0.34. AC1 measure range was 0.22 to 0.48. KA increased from 0.24 to 0.36 at 12 months with training. The percent agreement for pattern A peaked at 12 month with a 54% chance of having >50% raters in agreement and decreased over time, whereas that for patterns B and C increased over time to a maximum of 20% and 22%, respectively. Conclusion: This post-SBRT radiographic change categorization system has modest interrater agreement, and there is a suggestion of a training effect. Patterns of fibrosis evolve after SBRT and alternative categorization systems should be evaluated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric Evaluation of Incorporating Patient Geometric Variations Into Adaptive Plan Optimization Through Probabilistic Treatment Planning in Head and Neck Cancers

Four-dimensional (4D) adaptive radiation therapy (ART) treatment planning is an alternative to the conventional margin-based treatment planning approach. In 4D ART, interfraction patient geometric variations, gathered from computed tomography (CT) or cone beam CT (CBCT) images acquired during the patient treatment course, are directly incorporated into the adaptive plan optimization using a probabilistic treatment planning method. The goal of the present planning study was to evaluate the dosimetric differences between 4D ART and conventional margin-based adaptive planning strategies for head and neck cancers. In addition, we examined whether the dose differences achieved with 4D ART would translate into clinically relevant toxicity reductions using the existing normal tissue complication probability (NTCP) models.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Segregation behavior and phase instability of Eurofer97 after neutron irradiation to 72 dpa

Here, a reduced activation ferritic/martensitic steel, Eurofer97, was neutron irradiated in the vicinity of 300 °C in the High Flux Isotope Reactor (HFIR) up to 72 dpa. Advanced analytical scanning transmission electron microscopy and conventional transmission electron microscopy were applied to investigate the radiation-induced segregation and phase instability behavior after neutron irradiation. Amorphization was observed in M 23 C 6 carbides. Cr-rich clusters were seen within the matrix, near the lath boundaries and close to the M 23 C 6 carbides. Cr enrichment and Fe depletion were detected at both prior austenite grain boundaries and lath boundaries, despite different segregation magnitude. In addition, the enrichment of Ni, the depletion of V, and tiny cavities (presumably helium bubbles) are also found at lath boundaries. This work interrogates the evolution of microstructures after neutron irradiation, which provides detailed understanding on the microstructural aspects controlling the mechanical integrity of Eurofer97 under high-dose neutron damage.

36 MATERIALS SCIENCE↗

Development of a Negative Hydrogen Ion Source for Spatial Beam Profile Measurement of a High Intensity Positive Ion Beam

We have been developing a negative hydrogen ion (H{sup -} ion) source for a spatial beam profile monitor of a high intensity positive ion beam as a new diagnostic tool. In case of a high intensity continuous-wave (CW) deuteron (D{sup +}) beam for the International Fusion Materials Irradiation Facility (IFMIF), it is difficult to measure the beam qualities in the severe high radiation environment during about one-year cyclic operation period. Conventional techniques are next to unusable for diagnostics in the operation period of about eleven months and for maintenance in the one-month shutdown period. Therefore, we have proposed an active beam probe system by using a negative ion beam and started an experimental study for the proof-of-principle (PoP) of the new spatial beam profile monitoring tool. In this paper, we present the status of development of the H{sup -} ion source as a probe beam source for the PoP experiment.

43 PARTICLE ACCELERATORS↗

Dosimetric characteristics of Novalis Tx system with high definition multileaf collimator

A new Novalis Tx system equipped with a high definition multileaf collimator (HDMLC) recently became available to perform both image-guided radiosurgery and conventional radiotherapy. It is capable of delivering a highly conformal radiation dose with three energy modes: 6 MV photon energy, 15 MV photon energy, and 6 MV photon energy in a stereotactic radiosurgery mode with 1000 MU/min dose rate. Dosimetric characteristics of the new Novalis Tx treatment unit with the HDMLC are systematically measured for commissioning. A high resolution diode detector and miniion-chamber detector are used to measure dosimetric data for a range of field sizes from 4x4 mm to 400x400 mm. The commissioned Novalis Tx system has passed the RPC stereotactic radiosurgery head phantom irradiation test. The Novalis Tx system not only expands its capabilities with three energy modes, but also achieves better beam conformity and sharer beam penumbra with HDMLC. Since there is little beam data information available for the new Novalis Tx system, we present in this work the dosimetric data of the new modality for reference and comparison.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tungsten anode spectral model using interpolating cubic splines: Unfiltered x-ray spectra from 20 kV to 640 kV

Purpose: Monte Carlo methods were used to generate lightly filtered high resolution x-ray spectra spanning from 20 kV to 640 kV. Methods: X-ray spectra were simulated for a conventional tungsten anode. The Monte Carlo N-Particle eXtended radiation transport code (MCNPX 2.6.0) was used to produce 35 spectra over the tube potential range from 20 kV to 640 kV, and cubic spline interpolation procedures were used to create piecewise polynomials characterizing the photon fluence per energy bin as a function of x-ray tube potential. Using these basis spectra and the cubic spline interpolation, 621 spectra were generated at 1 kV intervals from 20 to 640 kV. The tungsten anode spectral model using interpolating cubic splines (TASMICS) produces minimally filtered (0.8 mm Be) x-ray spectra with 1 keV energy resolution. The TASMICS spectra were compared mathematically with other, previously reported spectra. Results: Using pairedt-test analyses, no statistically significant difference (i.e., p > 0.05) was observed between compared spectra over energy bins above 1% of peak bremsstrahlung fluence. For all energy bins, the correlation of determination (R{sup 2}) demonstrated good correlation for all spectral comparisons. The mean overall difference (MOD) and mean absolute difference (MAD) were computed over energy bins (above 1% of peak bremsstrahlung fluence) and over all the kV permutations compared. MOD and MAD comparisons with previously reported spectra were 2.7% and 9.7%, respectively (TASMIP), 0.1% and 12.0%, respectively [R. Birch and M. Marshall, “Computation of bremsstrahlung x-ray spectra and comparison with spectra measured with a Ge(Li) detector,” Phys. Med. Biol. 24, 505–517 (1979)], 0.4% and 8.1%, respectively (Poludniowski), and 0.4% and 8.1%, respectively (AAPM TG 195). The effective energy of TASMICS spectra with 2.5 mm of added Al filtration ranged from 17 keV (at 20 kV) to 138 keV (at 640 kV); with 0.2 mm of added Cu filtration the effective energy was 9 keV at 20 kV and 169 keV at 640 kV. Conclusions: Ranging from 20 kV to 640 kV, 621 x-ray spectra were produced and are available at 1 kV tube potential intervals. The spectra are tabulated at 1 keV intervals. TASMICS spectra were shown to be largely equivalent to published spectral models and are available in spreadsheet format for interested users by emailing the corresponding author (JMB)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Fermilab Facility for Dark Matter Discovery (F2D2): A Conceptual PIP-II Beam Stop Facility for Dark Sector Physics

What do the accelerator target stations of the next decade look like? The NuMI beamline, fed by Fermilab s Main Injector, recently exceeded 1 MW beam power. Future experiments fed by the PIP-II superconducting linear accelerator might demand upwards of 2 MW in continuous-wave mode, compared to the pulsed beams typical of neutrino experiments. Looking further into the future, the Muon Collider front end includes a target station with even higher power 5 MW or beyond. How do we build a 2+ MW target facility? How does a high-power, low-energy, CW beam affect target design compared to conventional high-energy neutrino targets? How do we manage radiation and heat? How is the facility serviced? What is the current state of capability, and what technologies do we need to develop? These questions are answered in the context of F2D2, a conceptual target station design for dark sector physics experiments using beam from PIP-II.

Williams, Jonathan K.↗

Determining Thermal Diffusivities of Radiating Specimens

Two heat-pulse techniques eliminate uncertainties due to radiation losses. Flashlamp supplies pulse of heat to one side of specimen. Temperatures of illumninated surface and of opposite surface monitored photometrically. In second method, pulse of electrons supplies heat to one side of specimen. Temperature of opposite side monitored by photon detector. Techniques needed because radiation heat losses in this temperature range introduce uncertainties into conventional heat-flux measurements.

Wood, C.↗

Energy dispersive X-ray diffraction in the diamond anvil, high-pressure apparatus - Comparison of synchrotron and conventional X-ray sources

The use of both conventional fixed-anode X-ray sources and synchrotron radiation to carry out energy-dispersive X-ray diffraction experiments at high pressure in a diamond anvil cell, is discussed. The photon flux at the sample and at the detector for the two cases are compared and the results are presented in graphs. It is shown that synchrotron radiation experiments can be performed with nearly two orders of magnitude increase in data rate if superior detectors and detector electronics are available.

Spain, I. L.↗

Self-Testing Computer Memory

Memory system for computer repeatedly tests itself during brief, regular interruptions of normal processing of data. Detects and corrects transient faults as single-event upsets (changes in bits due to ionizing radiation) within milliseconds after occuring. Self-testing concept surpasses conventional by actively flushing latent defects out of memory and attempting to correct before accumulating beyond capacity for self-correction or detection. Cost of improvement modest increase in complexity of circuitry and operating time.

Chau, Savio, N.↗

Blocked impurity band hybrid infrared focal plane arrays for astronomy

High-performance infrared hybrid focal plane arrays using 10- x 50-element Si:As blocked-impurity-band (BIB) detectors (cutoff wavelength = 28 microns) and matching switched MOSFET multiplexers have been developed and characterized for space astronomy. Use of impurity-band-conduction technology provides detectors which are nuclear-radiation-hard and free of the many anomalies associated with conventional silicon photoconductive detectors. Emphasis in the present work is on recent advances in detector material quality which have led to significantly improved detector and hybrid characteristics. Results demonstrating increased quantum efficiency (particularly at short-wavelength infrared), obtained by varying the BIB detector properties (infrared active layer thickness and arsenic doping profile), are summarized. Measured read noise and dark current for different temperatures are reported. The hybrid array performance achieved demonstrates that BIB detectors are well suited for use in astronomical instrumentation.

Reynolds, D. B.↗

Low-temperature thermal control for a lunar base

The generic problem of rejecting low- to moderate-temperature heat from space facilities located in a hot thermal sink environment is studied, and the example of a lunar base located near the equator is described. The effective thermal sink temperature is often above or near nominal room temperature. A three heat pump assisted thermal bus concept appears to be the most viable as they are the least sensitive to environmental conditions. Weight estimates are also developed for each of the five thermal control concepts studied: (1) 149kg/kW for a central thermal loop with unitary heat pumps; (2) 133 kg/kW for a conventional bus connected to large, central heat pumps at the radiator; (3) 134 kg/kW for a central, dual loop heat pump concept; (4) 95 kg/kW for the selective field-of-view radiator; and (5) 126 kg/kW for the regolith concept.

Swanson, Theodore D.↗

Line narrowing of AgGaSe2 optical parametric oscillator by injection seeding

Solid-state lasers are developed for atmospheric applications. Optical parametric oscillators (OPO) are being investigated as sources of tunable radiation in the 2.5-12 micron range where development of conventional lasers is subject to numerous difficulties. Parametric oscillation is a nonlinear optical technique for converting laser output to longer wavelengths. Incident photons, typically from a pulsed pump laser, are converted into two photons of longer wavelength, while satisfying energy conservation. The particular split of energy is determined by momentum conservation; the wavelength of interest is usually selected by angle orientation of the nonlinear material with respect to the direction of propagation of the pump beam. An OPO based on AgGaSe2 was considered.

Watson, George H.↗

Issues In Space Radiation Protection: Galactic Cosmic Rays

When shielding from cosmic heavy ions, one is faced with limited knowledge about the physical properties and biological responses of these radiations. Herein, the current health is discussed in terms of conventional protection practice and a test biological response model. The impact of biological response on optimum materials selection for cosmic ray shielding is presented in terms of the transmission characteristics of the shield material. Although liquid hydrogen is an optimum shield material, evaluation of the effectiveness of polymeric structural materials must await improvement in our knowledge of both the biological response and the nuclear processes.

Wilson, J. W.↗

Radio Frequency Interference Detection for Passive Remote Sensing Using Eigenvalue Analysis

Radio frequency interference (RFI) can corrupt passive remote sensing measurements taken with microwave radiometers. With the increasingly utilized spectrum and the push for larger bandwidth radiometers, the likelihood of RFI contamination has grown significantly. In this work, an eigenvalue-based algorithm is developed to detect the presence of RFI and provide estimates of RFI-free radiation levels. Simulated tests show that the proposed detector outperforms conventional kurtosis-based RFI detectors in the low-to-medium interference-to-noise-power-ratio (INR) regime under continuous wave (CW) and quadrature phase shift keying (QPSK) RFIs.

kurtosis↗

Radio Frequency Interference Detection for Passive Remote Sensing Using Eigenvalue Analysis

Radio frequency interference (RFI) can corrupt passive remote sensing measurements taken with microwave radiometers. With the increasingly utilized spectrum and the push for larger bandwidth radiometers, the likelihood of RFI contamination has grown significantly. In this work, an eigenvalue-based algorithm is developed to detect the presence of RFI and provide estimates of RFI-free radiation levels. Simulated tests show that the proposed detector outperforms conventional kurtosis-based RFI detectors in the low-to-medium interferece-to-noise-power-ratio (INR) regime under continuous wave (CW) and quadrature phase shift keying (QPSK) RFIs.

Passive remote sensing↗

Simulation-based Study of Single-Event Burnout in 4H-SiC High-Voltage Vertical Superjunction DMOSFET: Physical Failure Mechanism and Robustness vs. Performance Tradeoffs

We explore and elucidate physical failure mechanisms in a 4H-SiC, high voltage, superjunction (SJ) vertical DMOSFET from a single heavy ion strike using three-dimensional electro-thermal transient simulations. The single-event burnout (SEB) failure is thermal runaway from second breakdown, initiated by impact ionization and terminated with mesoplasma formation, at the center of the P-pillar/N+ substrate interface. We also demonstrate that the SEB performance of this SiC SJ DMOSFET is insensitive to the pillar width but sensitive to the strike location with ion strike at the P-pillar causing SEB at a lower blocking voltage than at the N-pillar. Compared to commercially available 1.2 kV blocking-rated non-SJ DMOSFETs, which have been demonstrated to survive SEB up to 525 V, the SJ DMOSFET increases SEB survival threshold voltage (VSEB) by a factor of 2.2, making it close to 1200 V, while the on-resistance is increased by only 11%. Using our recently developed figure of merit (FoM), which considers the trade-off between VSEB and on-state performance, we find that the SiC SJ DMOSFET achieves a FoM that is 14 times better, making it superior to conventional 1.2 kV SiC DMOSFETs for long-term radiation-tolerant operation in space applications.

Silicon Carbide↗