Search NASA⌕ Search

SEARCH · Search NASA

Results for “Detection Limit”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Ultrasensitive Photothermal Spectroscopy: Harnessing the Seebeck Effect for Attogram-Level Detection

Molecular-level spectroscopy is crucial for sensing and imaging applications, yet detecting and quantifying minuscule quantities of chemicals remain a challenge, especially when they surface adsorb in low numbers. Here, we introduce a photothermal spectroscopic technique that enables the high selectivity sensing of adsorbates with an attogram detection limit. Our approach utilizes the Seebeck effect in a microfabricated nanoscale thermocouple junction, incorporated into the apex of a microcantilever. We observe minimal thermal mass exhibited by the sensor, which maintains exceptional thermal insulation. The temperature variation driving the thermoelectric junction arises from the nonradiative decay of molecular adsorbates’ vibrational states on the tip. We demonstrate the detection of photothermal spectra of physisorbed trinitrotoluene (TNT) and dimethyl methylphosphonate (DMMP) molecules, as well as representative polymers, with an estimated mass of 10 -18 g.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dual-wavelength quantum cascade laser for trace gas spectroscopy

We demonstrate a sequentially operating dual-wavelength quantum cascade laser with electrically separated laser sections, emitting single-mode at 5.25 and 6.25 μm. Based on a single waveguide ridge, this laser represents a considerable asset to optical sensing and trace gas spectroscopy, as it allows probing multiple gas species with spectrally distant absorption features using conventional optical setups without any beam combining optics. The laser capability was demonstrated in simultaneous NO and NO{sub 2} detection, reaching sub-ppb detection limits and selectivity comparable to conventional high-end spectroscopic systems.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Quantifying Surface Water Dynamics at 30 Meter Spatial Resolution in the North American High Northern Latitudes 1991-2011

The availability of a dense time series of satellite observations at moderate (30 m) spatial resolution is enabling unprecedented opportunities for understanding ecosystems around the world. A time series of data from Landsat was used to generate a series of three maps at decadal time step to show how surface water has changed from 1991 to 2011 in the high northern latitudes of North America. Previous attempts to characterize the change in surface water in this region have been limited in either spatial or temporal resolution, or both. This series of maps was generated for the NASA Arctic and Boreal Vulnerability Experiment (ABoVE), which began in fall 2015. These maps show a nominal extent of surface water by using multiple observations to make a single map for each time step. This increases the confidence that any detected changes are related to climate or ecosystem changes not simply caused by short duration weather events such as flood or drought. The methods and comparison to other contemporary maps of the region are presented here. Initial verification results indicate 96% producer accuracy and 54% user accuracy when compared to 2-m resolution World View-2 data. All water bodies that were omitted were one Landsat pixel or smaller, hence below detection limits of the instrument.

Carroll, Mark↗

Atmospheric pressure ionisation - mass spectrometry for argon online monitoring in ASTRID

Safety, operability, waste transmutation and mastered investment costs are key issues for the development of generation IV reactors, especially sodium cooled fast reactors. To achieve a development scheduled around 2040, the nuclear energy division of CEA, France, is studying a prototype called ASTRID (Advanced Sodium Technological Reactor for Industrial Demonstration) which is in its conceptual design phase. To achieve a high level of maturity, In Service Inspection and Repair is very important, in particular fuel cladding failure detection. If such a failure occurs, fission products Xenon and Krypton are released. Their fast and sensitive detection is a challenge. The use of a commercial API-MS is evaluated in this work. Detection limits below 10 ppt have been measured for Kr 84 and for Xe 132. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Quantum sensing for emerging energy technologies

The ability to exploit quantum phenomena has enabled sensing technologies with detection limits below the classical limit. Sensors with applications in energy discovery, production, transportation, and consumption can be enhanced through quantum or hybrid quantum-classical sensors. Here, in this Review, we provide an overview of commercial and emerging quantum sensor platforms and their opportunity areas specific to advanced energy technologies. Key examples include: power grid-enhancing-technologies, where quantum magnetometers can detect powerline and transformer faults; electric vehicle-to-grid applications, where chip-scale atomic clocks can enable grid synchronization; and carbon capture and storage, where quantum gravimeters and single-photo LiDAR can detect microscopic leaks. Quantum sensor deployment requires further research into miniaturization and ruggedization for field deployment, cost-reduction, and workforce development. The maturation of clean energy technologies and quantum sensors provide opportunities for synergy, with the integration of quantum sensors into advanced energy technologies maximizing their security, reliability, and efficiency.

critical metals↗

Current Problems in X-Ray Emission Spectroscopy

Various problems that limit X-ray analysis in the analytical electron microscope are reviewed. Major emphasis is given to the trade-off between minimum mass fraction and spatial resolution. New developments such as high-brightness electron guns, new X-ray spectrometers and clean high-vacuum analysis conditions will lead to major improvements in the accuracy and detectability limits of X-ray emission spectroscopy.

Goldstein, Joseph I.↗

Metal–Organic Framework-Based Microfluidic Impedance Sensor Platform for Ultrasensitive Detection of Perfluorooctanesulfonate

The growing global concerns to public health from human exposure to perfluorooctanesulfonate (PFOS) requires rapid, sensitive, in-situ detection where current, state-of-the-art techniques are yet to adequately meet sensitivity and selectivity standards of the real-world. This work presents, for the first time, a synergistic approach for the targeted affinity-based capture of PFOS using a porous sorbent probe that enhances detection sensitivity by embedding it on a microfluidic conductive platform. This novel sorbent-containing platform functions as an electrochemical sensor to directly measure PFOS concentration through a proportional change in electrical response (increase in impedance). The extremely high surface area and pore volume of mesoporous metal-organic framework (MOF) Cr-MIL-101 is used as the probe for targeted PFOS capture based on the affinity of the chromium center towards both the fluorine tail groups as well as the sulfonate functionalities as demonstrated by spectroscopic (NMR and XPS) and microscopic (TEM) studies. Answering the need for an ultrasensitive PFOS detection technique, we are embedding these MOF capture probes inside a microfluidic channel, sandwiched between interdigitated microelectrodes (IDµE). The nanoporous geometry increases the signal to noise ratio of interdigitated microelectrodes tremendously increasing sensitivity; this in combination with the ability of the capture probes to interact with the PFOS at the molecular level and effectively transduce that response electrochemically has allowed us achieve a PFOS detection limit of 0.5 ng/L, which is unprecedented for in-situ analytical PFOS sensors and even comparable to quantification limits achieved using state-of-the-art ex situ techniques.

36 MATERIALS SCIENCE↗

A HERO'S LITTLE HORSE: DISCOVERY OF A DISSOLVING STAR CLUSTER IN PEGASUS

We report the discovery of an ultra-faint stellar system in the constellation of Pegasus. This concentration of stars was detected by applying our overdensity detection algorithm to the Sloan Digital Sky Survey Data Release 10 and confirmed with deeper photometry from the Dark Energy Camera (DECam) at the 4 m Blanco telescope. The best-fitting model isochrone indicates that this stellar system, Kim 1, features an old (12 Gyr) and metal-poor ([Fe/H] ∼ -1.7) stellar population at a heliocentric distance of 19.8 ± 0.9 kpc. We measure a half-light radius of 6.9 ± 0.6 pc using a Plummer profile. The small physical size and the extremely low luminosity are comparable to the faintest known star clusters Segue 3, Koposov 1 and 2, and Muñoz 1. However, Kim 1 exhibits a lower star concentration and is lacking a well-defined center. It also has an unusually high ellipticity and irregular outer isophotes, which suggests that we are seeing an intermediate mass star cluster being stripped by the Galactic tidal field. An extended search for evidence of an associated stellar stream within the 3 deg{sup 2} DECam field remains inconclusive. The finding of Kim 1 is consistent with current overdensity detection limits and supports the hypothesis that there are still a substantial number of extreme low-luminosity star clusters undetected in the wider Milky Way halo.

79 ASTRONOMY AND ASTROPHYSICS↗

Inductively Coupled Plasma: Fundamental Particle Investigations with Laser Ablation and Applications in Magnetic Sector Mass Spectrometry

Particle size effects and elemental fractionation in laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) are investigated with nanosecond and femtosecond laser ablation, differential mobility analysis, and magnetic sector ICP-MS. Laser pulse width was found to have a significant influence on the LA particle size distribution and the elemental composition of the aerosol and thus fractionation. Emission from individual particles from solution nebulization, glass, and a pressed powder pellet are observed with high speed digital photography. The presence of intact particles in an ICP is shown to be a likely source of fractionation. A technique for the online detection of stimulated elemental release from neural tissue using magnetic sector ICP-MS is described. Detection limits of 1 μg L -1 or better were found for P, Mn, Fe, Cu, and Zn in a 60 μL injection in a physiological saline matrix.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Functionalized Graphene Oxide as a Nanocarrier in a Multienzyme Labeling Amplification Strategy for Ultrasensitive Electrochemical Immunoassay of Phosphorylated p53 (S392)

P53 phosphorylation plays an important role in many biological processes and might be used as a potential biomarker in clinical diagnoses. We report a new electrochemical immunosensor for ultrasensitive detection of phosphorylated p53 at Ser392 (phospho-p53-392) based on graphene oxide (GO) as a nanocarrier in multienzymes amplification strategy. Greatly enhanced sensitivity was achieved by using the bioconjugates featuring horseradish peroxidase (HRP) and p53392 signal antibody (p53Ab2) linked to functionalized GO (HRP-p53Ab2-GO) at high ratio of HRP/p53Ab2. After a sandwich immunoreaction, the HRP-p53Ab2-GO captured onto the electrode surface produced an amplified electrocatalytic response by the reduction of enzymatically oxidized thionine in the presence of hydrogen peroxide. The increase of response current was proportional to the phospho-p53 concentration in the range of 0.02 to 2 nM with the detection limit of 0.01 nM, which was 10-fold lower than that of traditional sandwich electrochemical measurement for p53. The amplified immunoassay developed in this work shows acceptable stability and reproducibility and the assay results for phospho-p53 spiked in human plasma also show good recovery (92%~103.8%). This simple and low-cost immunosensor shows great promise for detection of other phosphorylated proteins and clinical applications.

59 BASIC BIOLOGICAL SCIENCES↗

Hyperspectral Microscopy of Explosives Particles Using an External Cavity Quantum Cascade Laser

Using infrared hyperspectral imaging, we demonstrate microscopy of small particles of the explosives compounds RDX, tetryl, and PETN with near diffraction-limited performance. The custom microscope apparatus includes an external cavity quantum cascade laser illuminator scanned over its tuning range of 9.13-10.53 µm in four seconds, coupled with a microbolometer focal plane array to record infrared transmission images. We use the hyperspectral microscopy technique to study the infrared absorption spectra of individual explosives particles, and demonstrate sub-nanogram detection limits.

(110.4234) Multispectral & Hyperspectral Imaging↗

Determination of He and D permeability of neutron-irradiated SiC tubes to examine the potential for release due to micro-cracking

Driven by the need to enlarge the safety margins of light water reactors in both design-basis and beyond-design-basis accident scenarios, the research and development of accident-tolerant fuel (ATF) has become an importance topic in the nuclear engineering and materials community. Continuous SiC fiber-reinforced SiC matrix ceramic composites are under consideration as a replacement for traditional zirconium alloy cladding owing to their high-temperature stability, chemical inertness, and exceptional irradiation resistance. Among the key technical feasibility issues, potential failure of the fission product containment due to probabilistic penetrating cracking has been identified as one of the two most critical feasibility issues, together with the radiolysisassisted hydrothermal corrosion of SiC. The experimental capability to evaluate the hermeticity of SiC-based claddings is an urgent need. In this report, we present the development of a comprehensive permeation testing station established in the Low Activation Materials Development and Analysis laboratory at Oak Ridge National Laboratory. Preliminary results for the hermeticity evaluation of un-irradiated monolithic SiC tubes, uncoated and coated SiC/SiC composite tubes, and neutron-irradiated monolithic SiC tubes at room temperature are exhibited. The results indicate that this new permeation testing station is capable of evaluating the hermeticity of SiC-based tubes by determining the helium and deuterium permeation flux as a function of gas pressure at a high resolution of 8.07 x 10 -12 atm-cc/s for helium and 2.83 x 10 -12 atm-cc/s for deuterium, respectively. The detection limit of this system is sufficient to evaluate the maximum allowable helium leakage rate of lab-scale tubular samples, which is linearly extrapolated from the evaluation standard used for a commercial as-manufactured light water reactor fuel rod at room temperature. The un-irradiated monolithic SiC tube is hermetic, as is manifested by the un-detectable deuterium permeation flux at various feeding gas pressures. A large helium leakage rate was detected for the uncoated SiC/SiC composite tube exposed to atmosphere, indicating it is inherently not hermetic. The hermeticity of coated SiC/SiC composite tubes is strongly dependent on the coating materials and the preparation of the substrate SiC/SiC composite samples. To simulate the practical application environment, monolithic CVD SiC tubes were exposed to neutron irradiation at the High Flux Isotope Reactor under high heat flux from the internal surface to the external surface. Although finite element analysis and resonant ultrasound spectroscopy measurement indicated that the combined neutron irradiation and high heat flux gave rise to a high probability of cracking within the sample, the hermeticity evaluation of the tested sample still exhibited gas tightness, emphasizing that SiC cracking is inherently a statistical phenomenon. The developed permeation testing station is capable of measuring the gas permeation flux in the range of interest with full confidence based on the presented results. It is considered a critical pre- /post-irradiation examination technique to characterize SiC-based cladding materials in asreceived and irradiated states to aid the research and development of ATF.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Measurement of tropospheric OH by laser long-path absorption spectroscopy

OH-radicals are measured by laser long-path absorption spectroscopy. A tunable Nd:YAG/dye laser system provides broadbanded light at 308 nm. The beam is expanded to 0.3 m and pointed to an array of retroreflectors placed at a distance of 2800 m. The returning beam is separated from the outgoing beam and focused into a spectrometer of 0.3 pm resolution. A 1024 element diode array is used as a detector. The signal is digitized by a 14 bit analog to digital converter. The ultimate aim is a detection limit of 10(exp 5) molecules cm(exp -3) of OH. However the measurements in 1991 allowed only the recognition of OH absorptions corresponding to 3 x 10(exp 6) OH cm(exp -3) with a signal to noise ratio of two. Improvements of the instrument are under way. The advantages of the DOAS method are: the accuracy of detection is guaranteed because loss of OH radicals within the device is avoided, the rate of OH production by the device is negligible, and absorptions of other trace gases could be corrected for; and the calibration procedure for the device is fast and easy. The disadvantages of the system are: time resolution is about minutes because about ten spectra had to be added to keep the noise level down, the OH concentration is averaged along the whole light path, weight (500 kg) and size (4x4 m) of the device; and approximately 10 l/min of coolant and supply of 8 kW electrical power are necessary.

Kraft, Michael↗

A new method for quantifying 64 Cu in nuclear debris samples

Quantifying 64 Cu in post-detonation nuclear debris samples can provide important diagnostic information regarding the structural materials used within a nuclear device. However, this task is challenging due to the weak gamma emissions associated with the decay of 64 Cu, its short half-life (12.701 h), and the presence of interfering fission product radioisotopes. Large quantities of debris sample are generally needed to accurately quantify 64 Cu, which can be problematic in sample-limited scenarios where other radiometric analyses are required. Herein, we present a new method for the separation of 64 Cu from solutions of mixed fission products and demonstrate the quantification of its activity through use of gas-flow proportional beta counting. Here, the new method was validated through a series of rigorous tests and was shown to improve the detection limit of 64 Cu by over two orders of magnitude, from 2.5 × 10 6 to 1.3 × 10 4 atoms/sample for 100 min measurements.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Sensitivity analysis towards trace-uranium detection with γ-γ coincidence NAA

An improved approach for detection of trace amounts of 238 U by means of neutron activation analysis (NAA) is presented. The analysis enhancement is obtained by utilizing γ-γ coincidence counting. An empirical method for evaluating the sensitivity gain in the presence of a large source-related background is presented. A comparison of detection limits is made between two counting schemes; namely, counting single gammas using one HPGe detector versus counting coincident gammas using two HPGe detectors placed face-to-face. Furthermore, a data-validated radiation transport model, created in GEANT4 for a single HPGe detector, is extended to handle the two detector setup. In this counting scheme, a 238 U-detection sensitivity enhancement of about a factor of 8 is predicted for a sample of Saint-Gobain G3 Sapphire when compared to the simpler singles counting approach.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Preconcentrating Minicolumn Sensors for Trace Environmental Monitoring

Preconcentrating minicolumn sensors represent an effective approach to achieve a substantial preconcentration factor within a sensing device, enabling very low detection limits as is required for environmental sensing. A selectively sorbent phase collects and concentrates analyte molecules as sample liquid is pumped through the column, ultimately equilibrating the entire sorbent phase with the analyte concentration in the sample. At equilibration, the amount on the column will be proportional to the analyte concentration when working at trace concentrations. We have demonstrated radiometric detection for the detection of radionuclides with this sensor, incorporating scintillating material in the column with the sorbent phase. The pertechnetate form of 99-technetium can be sensed using a mixed column bed containing anion exchange resin and scintillating plastic beads, collecting scintillation light with a pair of photomultiplier (PMT) tubes external to the transparent column body. For hexavalent chromium, we can also collect anions with anion exchange resin. In this case, optical fibers are coupled to the column body to measure the optical absorbance as a function of the amount of hexavalent chromium captured by the column. Both sensors can detect their respective analytes to levels below water standards.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of a colloidal gold immunochromatographic assay strip using monoclonal antibody for rapid detection of porcine deltacoronavirus

Porcine deltacoronavirus (PDCoV) cause diarrhea and dehydration in newborn piglets and has the potential for cross-species transmission. Rapid and early diagnosis is important for preventing and controlling infectious disease. In this study, two monoclonal antibodies (mAbs) were generated, which could specifically recognize recombinant PDCoV nucleocapsid (rPDCoV-N) protein. A colloidal gold immunochromatographic assay (GICA) strip using these mAbs was developed to detect PDCoV antigens within 15 min. Results showed that the detection limit of the GICA strip developed in this study was 10 3 TCID 50 /ml for the suspension of virus-infected cell culture and 0.125 μg/ml for rPDCoV-N protein, respectively. Besides, the GICA strip showed high specificity with no cross-reactivity with other porcine pathogenic viruses. Three hundred and twenty-five fecal samples were detected for PDCoV using the GICA strip and reverse transcription-quantitative real-time PCR (RT-qPCR). The coincidence rate of the GICA strip and RT-qPCR was 96.9%. The GICA strip had a diagnostic sensitivity of 88.9% and diagnostic specificity of 98.5%. The specific and efficient detection by the strip provides a convenient, rapid, easy to use and valuable diagnostic tool for PDCoV under laboratory and field conditions.

Wang, Wei↗

Emerging investigator series: quantification of multiwall carbon nanotubes in plant tissues with spectroscopic analysis

If agricultural plants are exposed to carbon nanotubes (CNTs), they can potentially take up the CNTs from growth media and translocate them to their different tissues. In addition, agricultural application of CNTs recently attracted increasing attention, as they could promote germination, enhance crop yield, and exhibit other benefits. For evaluating the environmental effects of CNTs and optimizing their agricultural application, it is essential to quantify CNTs in plant tissues. In this study, pristine (p-) and carboxyl-functionalized (c-) multiwall CNTs (MWCNTs) were extracted from plant tissues by a sequential digestion with nitric acid (HNO 3 ) and sulfuric acid (H 2 SO 4 ). The extracted MWCNTs were stabilized with nonionic surfactant Triton X-100 and analyzed with ultraviolet-visible (UV-vis) spectroscopic analysis to measure the concentration of the MWCNTs in plant (lettuce) tissues. The MWCNT concentration was linearly correlated with the absorbance at 800 nm. The detection limit for p- and c-MWCNTs was achieved at 0.10–0.12, 0.070–0.081, 0.019–0.18 μg mg -1 for leaf, stem, and root tissues, respectively. The developed method was applied for lettuce (Lactuca sativa, cv. black seeded Simpson) hydroponically grown with 5, 10, 20 mg L -1 of p-MWCNTs and c-MWCNTs in the culture solution. We detected 0.21 ± 0.05–4.57 ± 0.39 μg mg -1 p-MWCNTs and 0.20 ± 0.17–0.75 ± 0.25 μg mg -1 c-MWCNTs in the lettuce roots, positively correlated with the dose of CNTs in solution. We have come up with a method for rapid quantification of CNTs in plant tissues using a widely-accessible technique, which can enable reliable analysis of CNTs in plant tissues and provide critical information for evaluating the environmental implications and managing agricultural application of CNTs.

54 ENVIRONMENTAL SCIENCES↗