The Effects of Fuel Characteristics on Stoichiometric Spark-Assisted HCCI

The characteristics of fuel lean HCCI operation using a variety of fuels are well known and have been demonstrated using different engine concepts in the past. In contrast, stoichiometric operation of HCCI is less well documented. Recent studies have highlighted the benefits of operating at a stoichiometric condition in terms of load expansion combined with the applicability of three way catalyst technology to reduce NOx emissions. In this study the characterization of stoichiometric HCCI using gasoline-like fuels was undertaken. The fuels investigated are gasoline, a 50 vol% blend of iso-butanol and gasoline (IB50), and an 85% vol blend of ethanol and gasoline (E85). A single cylinder engine operating with direct injection and spark assist combined with a fully variable hydraulic valve actuation system allowed a wide range of operating parameters to be studied. The resultant fuel properties which differed in terms of octane rating, fuel oxygenation and heat of vaporization show that stoichiometric HCCI is possible using a range of fuels but that these fuel characteristics do have some effect on the combustion characteristics. How these fuel properties can enable an increased engine operating envelope to be achieved, in comparison with both fuel lean HCCI and conventional spark ignited combustion, is then discussed.

02 PETROLEUM↗

Measure Guideline: Selecting Ventilation Systems for Existing Homes

This document addresses adding -or improving - mechanical ventilation systems to existing homes. The purpose of ventilation is to remove contaminants from homes, and this report discusses where, when, and how much ventilation is appropriate in a home, including some discussion of relevant codes and standards. Advantages, disadvantages, and approximate costs of various system types are presented along with general guidelines for implementing the systems in homes. CARB intends for this document to be useful to decision makers and contractors implementing ventilation systems in homes. Choosing the "best" system is not always straightforward; selecting a system involves balancing performance, efficiency, cost, required maintenance, and several other factors. It is the intent of this document to assist contractors in making more informed decisions when selecting systems. Ventilation is an integral part of a high-performance home. With more air-sealed envelopes, a mechanical means of removing contaminants is critical for indoor environmental quality and building durability.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Research & Development Roadmap for Next-Generation Appliances

Appliances present an attractive opportunity for near-term energy savings in existing building, because they are less expensive and replaced more regularly than heating, ventilation, and air-conditioning (HVAC) systems or building envelope components. This roadmap targets high-priority research and development (R&D), demonstration and commercialization activities that could significantly reduce residential appliance energy consumption. The main objective of the roadmap is to seek activities that accelerate the commercialization of high-efficiency appliance technologies while maintaining the competitiveness of American industry. The roadmap identified and evaluated potential technical innovations, defined research needs, created preliminary research and development roadmaps, and obtained stakeholder feedback on the proposed initiatives.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

US-China Clean Energy Research Center on Building Energy Efficiency: Materials that Improve the Cost-Effectiveness of Air Barrier Systems

The US–China Clean Energy Research Center (CERC) was launched in 2009 by US Energy Secretary Steven Chu, Chinese Minister of Science and Technology Wan Gang, and Chinese National Energy Agency Administrator Zhang Guobao. This 5-year collaboration emerged from the fact that the United States and China are the world’s largest energy producers, energy consumers, and greenhouse gas emitters, and that their joint effort could have significant positive repercussions worldwide. CERC’s main goal is to develop and deploy clean energy technologies that will help both countries meet energy and climate challenges. Three consortia were established to address the most pressing energy-related research areas: Advanced Coal Technology, Clean Vehicles, and Building Energy Efficiency (BEE). The project discussed in this report was part of the CERC-BEE consortia; its objective was to lower energy use in buildings by developing and evaluating technologies that improve the cost-effectiveness of air barrier systems for building envelopes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Influence of Microbial Membranes on Biofilm Formation, Scaling Reactions, and Production Chemistry in Engineered Energy Systems (Final Report)

Humans are engineering the deep subsurface for the purposes of energy-capture, energy-storage, and environmental mitigation. Despite the potential for microbial communities to significantly alter the effectiveness of these technologies, we have historically lacked a clear understanding of how microbial cells interact in a fractured shale system. Existing knowledge has been heavily based on genomic information, lacking studies on in situ physiologies, kinetic rates, and attachment mechanisms governing biogeochemical reactions in the system. The overarching goal of this research was to advance understanding of engineered hydrocarbon extraction systems as they evolve from newly developed environments to mature use. Plasma membranes protect microbial cells, mediate many critical functions, and respond to intracellular cues and ecological perturbations through physicochemical modifications. The project objectives were to 1) characterize variables influencing growth and membrane features of shale taxa, 2) characterize the interactions between shale matrices and microorganisms and 3) elucidate engineered and environmental processes driving biogeochemical signatures at the field scale. Objectives were realized through laboratory experiments involving growth of pure cultures and enrichments in continuous culture and biofilms; access to samples from two DOE-NETL funded energy-capture sites: Marcellus Shale Energy and Environmental Laboratory (MSEEL and MSEEL II); and through collaborations with scientists and engineers at the Environmental Molecular Science Laboratory (EMSL) and National Energy Technology Laboratory (NETL). Key findings showed (a) Halanaerobium congolense WG10 makes its membrane more fluid and thicker through increasing its polyunsaturated fatty acid (PUFA) composition under non-optimal salinities (7% and 20%) compared to the optimum (13% NaCl); (b) anionic phospholipids within the plasma membrane are important for high salinity tolerance in H. congolense WG10 while zwitterionic species modulate biofilm physiologies in both isolate and mixed cultures, and (c) tyrosine accumulation with overexpression of Na+/H+ antiporters are essential for osmoprotection in H. congolense WG10 under high salinity while upregulation of aromatic amino acid synthesis and cell envelope maintenance underpin biofilm formation. It is clear from these results that microbial persistence in fractured shale reservoirs under environmental and engineered perturbations requires strategic plasma membrane lipid chemistry adjustments and metabolic restructuring, with implications for improved shale microbiology management and more efficient hydrocarbon extraction approaches targeting microorganisms.

03 NATURAL GAS↗

Large-Scale Mini-Magnetosphere Plasma Propulsion (M2P2) Experiments

Mini-Magnetosphere Plasma Propulsion (M2P2) is an innovative plasma propulsion system that has the potential to propel spacecraft at unprecedented speeds of 50 to 80 km/s, with a low power requirement of approx. 1 kW per 100 kg of payload and -1 kg of neutral gas [fuel] consumption per day of acceleration. Acceleration periods from several days to a few months are envisioned. High specific impulse and efficiency are achieved through coupling of the spacecraft to the 400 km/s. solar wind through an artificial magnetosphere. The mini-magnetosphere or inflated magnetic bubble is produced by the injection of cold dense plasma into a spacecraft-generated magnetic field envelope. Magnetic bubble inflation is driven by electromagnetic processes thereby avoiding the material and deployment problems faced by mechanical solar sail designs. Here, we present the theoretical design of M2P2 as well as initial results from experimental testing of an M2P2 prototype demonstrating: 1) inflation of the dipole magnetic field geometry through the internal injection of cold plasma; and 2) deflection of and artificial solar wind by the prototype M2P2 system. In addition, we present plans for direct laboratory measurement of thrust imparted to a prototype M2P2 by an artificial solar wind during the summer of 2001.

Winglee, R. M.↗

Building America Case Study: Selecting Ventilation Systems for Existing Homes (Fact Sheet)

This document addresses adding -or improving - mechanical ventilation systems to existing homes. The purpose of ventilation is to remove contaminants from homes, and this report discusses where, when, and how much ventilation is appropriate in a home, including some discussion of relevant codes and standards. Advantages, disadvantages, and approximate costs of various system types are presented along with general guidelines for implementing the systems in homes. CARB intends for this document to be useful to decision makers and contractors implementing ventilation systems in homes. Choosing the "best" system is not always straightforward; selecting a system involves balancing performance, efficiency, cost, required maintenance, and several other factors. It is the intent of this document to assist contractors in making more informed decisions when selecting systems. Ventilation is an integral part of a high-performance home. With more air-sealed envelopes, a mechanical means of removing contaminants is critical for indoor environmental quality and building durability.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building Energy Asset Score for Real Estate Managers

The Building Energy Asset Score is a national standardized tool for evaluating the physical and structural energy efficiency of commercial and multifamily residential buildings. The Asset Score generates a simple energy efficiency rating that enables comparison among buildings, and identifies opportunities for users to invest in energy efficiency upgrades. It is web-based and free to use. This fact sheet discusses the value of the score for real estate managers.

Building energy simulation, building envelope, hot↗

Advancing Replicable Solutions for High-Performance Homes in the Southeast

Southface Energy Institute (Southface) partnered with owners and/or builders with various market constraints and ultimate goals for three projects in different climate zones: Savannah, GA (CZ 2), Clemson, SC (CZ 3), and LaFayette, GA (CZ 4). This report documents the design process, computational energy modeling, construction, envelope performance metrics, long-term monitoring results, and successes and failures of the design and execution of these high performance homes. The three bedroom/two bathroom test home in Savannah Gardens on an elevated slab foundation has a semi-conditioned, encapsulated attic. A neighboring home built to EarthCraft specifications was also monitored as a control for exterior foam insulation and a heat pump water heater (HPWH). For the JMC Patrick Square, a single-story project in Clemson, the small-scale production builder wanted to increase their level of energy efficiency beyond their current green building practices, including bringing ducts into conditioned space. Through a combination of upgrade measures the team met this goal and achieved many Zero Energy Ready Home requirements. LaFayette Housing Authority undertook a development of 30 affordable rental housing units in 15 duplexes in LaFayette, GA. Because they would be long-term owners, their priorities were low utility bills for the residents and durable, maintainable buildings. The team employed BEopt to optimize buildling envelope and systems choices, including 2x6 advanced framed walls, insulated slab, and heat pump water heater in a utility closet which was ducted to/from an encapsulated attic.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building America Case Study: Savannah Gardens, Savannah, Georgia

Southface Energy Institute (Southface) partnered with owners and/or builders with various market constraints and ultimate goals for three projects in different climate zones: Savannah, GA (CZ 2), Clemson, SC (CZ 3), and LaFayette, GA (CZ 4). This report documents the design process, computational energy modeling, construction, envelope performance metrics, long-term monitoring results, and successes and failures of the design and execution of these high performance homes. The three bedroom/two bathroom test home in Savannah Gardens on an elevated slab foundation has a semi-conditioned, encapsulated attic. A neighboring home built to EarthCraft specifications was also monitored as a control for exterior foam insulation and a heat pump water heater (HPWH). For the JMC Patrick Square, a single-story project in Clemson, the small-scale production builder wanted to increase their level of energy efficiency beyond their current green building practices, including bringing ducts into conditioned space. Through a combination of upgrade measures the team met this goal and achieved many Zero Energy Ready Home requirements. LaFayette Housing Authority undertook a development of 30 affordable rental housing units in 15 duplexes in LaFayette, GA. Because they would be long-term owners, their priorities were low utility bills for the residents and durable, maintainable buildings. The team employed BEopt to optimize building envelope and systems choices, including 2x6 advanced framed walls, insulated slab, and heat pump water heater in a utility closet which was ducted to/from an encapsulated attic.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building Performance Standards and Energy Code Alignment - Technical Brief

Building energy codes focus on building design, construction and renovation and have significantly increased building efficiency since the first national energy code was published in 1975. Most jurisdictions have energy codes based on ANSI/ASHRAE/IES Standard 90.1 (hereto referred to as Standard 90.1) and the International Energy Conservation Code (IECC). Compliance options available in these model energy codes include a prescriptive path, whole building performance paths – including IECC Total Building Performance (TBP), Standard 90.1 Energy Cost Budget (ECB) method and Performance Rating Method (PRM) – and system performance paths for envelope and heating, ventilation, and air-conditioning systems. Building performance standard (BPS) policies are an emerging policy tool used by jurisdictions to reduce the operational energy use or greenhouse gas (GHG) emissions of the existing commercial building stock. BPS policies vary widely between jurisdictions and are tailored to each location’s climate and energy goals. Intuitively, projects that met a recent edition of the energy code should comply with the BPS targets. However, some new buildings may struggle with meeting the BPS for the following reasons: 1. Energy codes focus on the design of the building and its projected ability to perform efficiently, while BPS compliance is dependent on the actual ongoing performance of the building, considering variables like occupancy, operation, and maintenance. 2. There are significant differences in the methodologies used to determine BPS compliance versus code compliance, including how each handles compliance metrics, handling of building amenities, and renewable energy generation. 3. The prescriptive compliance path in the energy code is based on performance of individual building components, as opposed to the performance compliance path which accounts for holistic building design strategies and interdependent building systems. This can result in a significant variability in post-occupancy performance for buildings built using the prescriptive path. Designs on the lower end of the permitted efficiency range may struggle with meeting the BPS.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Regal Beloit Final Technical Report

The original project proposal submitted from NovaTorque Inc (NovaTorque) in 2016 was to improve the existing motor with 95% efficiency by reducing the losses by 21% to achieve 96%. A few months after the proposal was submitted, NovaTorque lost funding and went out of business. The assets of NovaTorque were then acquired by Regal Beloit Corporation (“Regal Beloit” or “Regal”). When the NovaTorque proposal was selected, the project was transferred to Regal Beloit. Once we had production samples from the new Regal production line, they were tested at the Regal Beloit test lab in Wausau, WI. The original NovaTorque motor had an efficiency of 95%, but when the technology was transferred to Regal Beloit, there were multiple manufacturing improvements made, even though the basic electromagnetic design did not change. The test results in Wausau showed that the motors made at the Regal Beloit plant had an efficiency of 96%. Since the goal of the project was to reduce the losses by 21%, a new efficiency target of 96.8% became the project objective. In the first budget period, motors were tested to get the baseline performance. We then used FEA modeling with ANSYS Maxwell to model the existing motor to get correlation between the FEA simulations and the actual test results. Once the model was validated, we evaluated some changes that could be made to the stator to reduce the losses and improve efficiency without changing the rotor or stator housing, keeping the modifications easy to implement. The changes were primarily in the area of making the stator axially shorter and adding Soft Magnetic Composite (SMC) tooth tips. In the second budget period, we proceeded to design and build the new stator that was identified above and identified additional improvements in the process that included a stator machining modification and the use of rectangular wire. When we actually built the motor, the choice of rectangular wire turned out to be a problem. The wire was made by squishing round wire to get the rectangular shape, which caused work hardening, making the wire too stiff to make the desired coils. We shifted to annealed square wire which was better, but we still could not maintain the proper coil envelope. The result was that we had reduced cross section area for stator laminations. We also had to have a radial offset resulting in a radial misalignment between the stator and rotor because of the oversized coils. After the motor was completed, it was shipped to Texas A&M University for testing. With the loss of flux from these issues, the measured motor efficiency was only 96.3%. The primary focus of this motor was to make sure our FEA simulation model predicted the measured losses and overall efficiency, this we moved on to the FEA simulation. The FEA simulations of the motor “as built” with misalignments had good correlation with the test results, so the next step was to use that model to optimize the design of the motor for a final build. This time we considered changes to the stator and rotor and also minor changes to the housing diameter. In the third budget period, we did the detailed design and construction of the final prototypes. The final prototypes had a slight increase in the stator diameter to fit in a standard Regal Beloit housing. We shortened the stator and use more layers of wire in the coils. We also increased the cone angle of the rotor and stator from the original 110 degrees to 130 degrees to get some additional efficiency and optimized the stator cross section. The predicted efficiency from the FEA simulations was 96.9%. When completed, the motors were tested. We were a little short of reaching our target efficiency goal of 96.8%. We were only able to get to 96.7% efficiency. While it may be possible with additional iterations in designs and future builds to gain that additional 0.1%, we believe that we are close to the best we can achieve from a practical viewpoint, and additional iterations would be more work than the potential gains would be worth. No other motor in this class can even reach the 96% that we started with.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Tail of KdsC: Conformational Changes Control the Activity of a Haloacid Dehalogenase Superfamily Phosphatase

The phosphatase KdsC cleaves 3-deoxy-d-manno-octulosonate 8-phosphate to generate a molecule of inorganic phosphate and Kdo. Kdo is an essential component of the lipopolysaccharide envelope in Gram-negative bacteria. Because lipopolysaccharide is an important determinant of bacterial resistance and toxicity, KdsC is a potential target for novel antibacterial agents. KdsC belongs to the broad haloacid dehalogenase superfamily. In haloacid dehalogenase superfamily enzymes, substrate specificity and catalytic efficiency are generally dictated by a fold feature called the cap domain. It is therefore not clear why KdsC, which lacks a cap domain, is catalytically efficient and highly specific to 3-deoxy-d-manno-octulosonate 8-phosphate. Here, we present a set of seven structures of tetrameric Escherichia coli KdsC (ranging from 1.4 to 3.06 {angstrom} in resolution) that model different intermediate states in its catalytic mechanism. A crystal structure of product-bound E. coli KdsC shows how the interface between adjacent monomers defines the active site pocket. Kdo is engaged in a network of polar and nonpolar interactions with residues at this interface, which explains substrate specificity. Furthermore, this structural and kinetic analysis strongly suggests that the binding of the flexible C-terminal region (tail) to the active site makes KdsC catalytically efficient by facilitating product release.

36 MATERIALS SCIENCE↗

EXPLORING THE EFFECTS OF STELLAR ROTATION AND WIND CLEARING: DEBRIS DISKS AROUND F STARS

We have conducted a study of debris disks around F stars in order to explore correlations between rotation, stellar winds, and circumstellar disks. We obtained new 24 {mu}m photometry from the Multiband Imaging Photometer for Spitzer (MIPS) camera for a sample of 188 relatively nearby F dwarfs with various rotation rates and optical colors, and combined it with archival MIPS data for 66 more F stars, as well as Wide-field Infrared Survey Explorer data for the entire sample, plus 9 more F stars. Based on the objects' K{sub s} - [24] and [3.4] - [22] colors, we identify 22 stars in our sample as having 22 and/or 24 {mu}m excesses above our detection limit, 13 of which are new discoveries. Our overall disk detection rate is 22/263, or 8%, consistent with previous determinations of disk fractions in the solar neighborhood. While fast-rotating stars are expected to have strong winds capable of efficiently removing dust, we find no correlation between rotational velocity and infrared excess. Similarly, we find no significant difference in excess detection rate between late-type F stars, which have convective surfaces, and early-type F stars, which have fully radiative envelopes. However, the essentially unknown range of ages in this sample may be washing out any effects relating rotation, winds, and disks.

79 ASTRONOMY AND ASTROPHYSICS↗

SIMULATIONS OF ACCRETION POWERED SUPERNOVAE IN THE PROGENITORS OF GAMMA-RAY BURSTS

Observational evidence suggests a link between long-duration gamma-ray bursts (LGRBs) and Type Ic supernovae. Here, we propose a potential mechanism for Type Ic supernovae in LGRB progenitors powered solely by accretion energy. We present spherically symmetric hydrodynamic simulations of the long-term accretion of a rotating gamma-ray burst progenitor star, a 'collapsar', onto the central compact object, which we take to be a black hole. The simulations were carried out with the adaptive mesh refinement code FLASH in one spatial dimension and with rotation, an explicit shear viscosity, and convection in the mixing length theory approximation. Once the accretion flow becomes rotationally supported outside of the black hole, an accretion shock forms and traverses the stellar envelope. Energy is carried from the central geometrically thick accretion disk to the stellar envelope by convection. Energy losses through neutrino emission and nuclear photodisintegration are calculated but do not seem important following the rapid early drop of the accretion rate following circularization. We find that the shock velocity, energy, and unbound mass are sensitive to convective efficiency, effective viscosity, and initial stellar angular momentum. Our simulations show that given the appropriate combinations of stellar and physical parameters, explosions with energies {approx}5 Multiplication-Sign 10{sup 50} erg, velocities {approx}3000 km s{sup -1}, and unbound material masses {approx}> 6 M{sub Sun} are possible in a rapidly rotating 16 M{sub Sun} main-sequence progenitor star. Further work is needed to constrain the values of these parameters, to identify the likely outcomes in more plausible and massive LRGB progenitors, and to explore nucleosynthetic implications.

79 ASTRONOMY AND ASTROPHYSICS↗

Two-Level Chebyshev Filter Based Complementary Subspace Method: Pushing the Envelope of Large-Scale Electronic Structure Calculations

We describe here a novel iterative strategy for Kohn–Sham density functional theory calculations aimed at large systems (>1,000 electrons), applicable to metals and insulators alike. In lieu of explicit diagonalization of the Kohn–Sham Hamiltonian on every self-consistent field (SCF) iteration, we employ a two-level Chebyshev polynomial filter based complementary subspace strategy to (1) compute a set of vectors that span the occupied subspace of the Hamiltonian; (2) reduce subspace diagonalization to just partially occupied states; and (3) obtain those states in an efficient, scalable manner via an inner Chebyshev filter iteration. By reducing the necessary computation to just partially occupied states and obtaining these through an inner Chebyshev iteration, our approach reduces the cost of large metallic calculations significantly, while eliminating subspace diagonalization for insulating systems altogether. We describe the implementation of the method within the framework of the discontinuous Galerkin (DG) electronic structure method and show that this results in a computational scheme that can effectively tackle bulk and nano systems containing tens of thousands of electrons, with chemical accuracy, within a few minutes or less of wall clock time per SCF iteration on large-scale computing platforms. We anticipate that our method will be instrumental in pushing the envelope of large-scale ab initio molecular dynamics. As a demonstration of this, we simulate a bulk silicon system containing 8,000 atoms at finite temperature, and obtain an average SCF step wall time of 51 s on 34,560 processors; thus allowing us to carry out 1.0 ps of ab initio molecular dynamics in approximately 28 h (of wall time).

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Building Energy Asset Score for State and Local Governments

The Building Energy Asset Score is a national standardized tool for evaluating the physical and structural energy efficiency of commercial and multifamily residential buildings. The Asset Score generates a simple energy efficiency rating that enables comparison among buildings, and identifies opportunities for users to invest in energy efficiency upgrades. It is web-based and free to use. This fact sheet discusses the value of the score for state and local governments.

Building energy simulation, building envelope, hot↗