Local measurements in turbulent flows through cross correlation of optical signals
Device to measure turbulent flows by cross correlation of optical signals
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Device to measure turbulent flows by cross correlation of optical signals
A refined Taylor instability model is developed to describe the surface morphology of rhyolite lava flows. The effect of the downslope flow of the lava on the structures resulting from the Taylor instability mechanism is considered. Squire's (1933) transformation is developed for this flow in order to extend the results to three-dimensional modes. This permits assessing why ridges thought to arise from the Taylor instability mechanism are preferentially oriented transverse to the direction of lava flow. Measured diapir and ridge spacings for the Little and Big Glass Mountain rhyolite flows in northern California are used in conjunction with the model in order to explore the implications of the Taylor instability for flow emplacement. The model suggests additional lava flow features that can be measured in order to test whether the Taylor instability mechanism has influenced the flows surface morphology.
Here, the shear strength and hydraulic permeability of the interface between well cement and casing was investigated using a triaxial direct shear apparatus. For the first time, these experiments provide measurements under controlled stress conditions with fluid flow measurements along the interface. The low cohesion (1.1 ± 1.1 MPa) and the high friction angle (43.4 ± 2.0°) indicates that the shear strength of the interface is provided by friction. This implies that the state of stress of the cement is critical to well integrity. The hydraulic aperture of the undamaged cement-steel samples was 6.8 ± 1.0 microns. Shear damage to the interface caused a decrease (-20 %) in hydraulic aperture for samples aged up to 1 month, and an increase (+300 %) for samples cured for two years. We performed numerical simulations to estimate the leakage potential from a carbon storage operation. This model predicts negligible leakage amounts (47 tonnes) in a shear-damaged well for the modeled injection of ~1.26 million tonnes of CO 2 . Thus, our measurements indicate that the cement-casing interface is not a significant leakage pathway in its intact or damaged state, and that shear-driven failure scenarios for this interface are not a significant risk to CO 2 storage security.
The Mass Flowmeter is a device used to measure flow of oxygen in spacecraft's life support system. Tylan Corporation's Mass Flow Controller's major application is accurate control of reactive gases-- such as hydrogen, phosphine and silane as they are diffused at extremely high temperatures into silicon wafers. Wafers are ultimately cut up into integrated circuits or "chips" for electronic products. Precise process control afforded by the Mass Flow Controller makes it possible to produce circuit chips of greater performance at lower cost.
An investigation was conducted to see if additive manufacturing could be used to fabricate more efficient manifold designs for improved flow, reduced stresses, and decreased number of joints to be sealed for a solid oxide electrolyzer used to convert carbon dioxide to oxygen. Computational flow and mechanical modeling were conducted on a NASA Glenn Research Center patented cell and stack design with the potential to achieve a 3-4 times mass reduction. Various manifold designs were modeled, and two were downselected to be fabricated and tested. Some benefit was seen in a baffled manifold design, which directed incoming flow more effectively into the flow channels, compared to the original design, where the flow spent more time within the manifold itself. Flow measurements indicated some non-uniformity of flow across the channels at higher flow rates, which were not predicted by the model. Some possible explanations for the differences are discussed.
Time accurate numerical simulations were performed using the Reynolds-averaged Navier-Stokes (RANS) flow solver OVERFLOW for a heavy lift, slowed-rotor, compound helicopter configuration, tested at the NASA Langley 14- by 22-Foot Subsonic Tunnel. The primary purpose of these simulations is to provide support for the development of a large field of view Particle Imaging Velocimetry (PIV) flow measurement technique supported by the Subsonic Rotary Wing (SRW) project under the NASA Fundamental Aeronautics program. These simulations provide a better understanding of the rotor and body wake flows and helped to define PIV measurement locations as well as requirements for validation of flow solver codes. The large field PIV system can measure the three-dimensional velocity flow field in a 0.914m by 1.83m plane. PIV measurements were performed upstream and downstream of the vertical tail section and are compared to simulation results. The simulations are also used to better understand the tunnel wall and body/rotor support effects by comparing simulations with and without tunnel floor/ceiling walls and supports. Comparisons are also made to the experimental force and moment data for the body and rotor.
Heat flow measurements of 25-Ah lithium thionyl chloride cells provided a method to calculate an effective thermal potential, E(TP) of 3.907 V. The calculation is useful to determine specific heat generation of this cell chemistry and design. The E(TP) value includes heat generation by electrochemical cell reactions, competitive chemical reactions, and resistance heating at the tabs, connectors, and leads. Heat flow was measured while applying electrical loads to the cell in an isothermal calorimeter set at 0, 20, and 60 C.
Line-of-sight measurements of velocity, temperature, pressure, density, and mass flux were performed in a transient shock tube flow using three laser absorption schemes. All methods employed an intracavity-doubled ring dye laser tuned to an OH transition at 306 nm. In the first scheme, the gas was labeled by 193.3-nm excimer photolysis of H2O, and the passage of the generated OH was detected downstream. In the second method, the laser was tuned at a rate of 3 kHz over the R1(7) and R1(11) line pair, and absorption was simultaneously monitored at 90 and 60 deg with respect to the flow. Velocity was determined from the Doppler shift of the profiles and the temperature from the intensity ratio of the lines. Pressure was determined from both the magnitude of absorption and the collisional broadening. In the third method, the laser wavelength was fixed at a single frequency, and a continuous measurement of velocity and pressure was obtained using the signals from the two beam paths. All methods gave results which compare favorably to calculated values.
Low-speed wind-tunnel tests were conducted to determine the effects of free-stream velocity and incidence angle on the aerodynamic and acoustic performance of a translating centerbody choked-flow inlet. The inlet was sized to fit a 13.97 cm diameter fan with a design weight flow of 2.49 kg/sec. Performance was determined at free-stream velocities to 45 meters per second and incidence angles of 0 deg to 50 deg. The inlet was operated in both the choked and unchoked modes over a range of weight flows. Measurements were made of inlet total pressure recovery, flow distortion, surface static pressure distribution, and fan noise suppression. In the choked mode, increasing incidence angle tended to reduce the amount of inlet noise suppression for a given amount of inlet suction. This tendency was overcome by applying sufficient inlet suction to increase the flow Mach number. At 45 meters per second free-stream velocity, at least 22 decibels of suppression were measured at 35 deg incidence angle with a total pressure recovery of 0.985.
X-ray attenuation technique has been widely used in two-phase flow measurement. In general, an x-ray system measures the overall attenuation of the two-phase mixture existing between an x-ray source and a detector. One can obtain the void fraction from the intensity of the attenuated x-ray beam and known attenuation coefficients of each phase. Fig. 1 shows a schematic of the line detector system developed at Virginia Tech, and the reconstructed image of a sample slug bubble. The system is capable of obtaining high-resolution (100 {mu}m or less) x-ray images of two-phase flow at a frame rate exceeding 1000 Hz. Note that the intensity of the image can be converted into the line-averaged void fraction data measured by each detector pixel. Typical x-ray systems do not resolve the energy spectrum. Instead, they only measure the total energy deposited in the detector during the exposure period. However, the x-ray source generated from x-ray tubes present polychromatic characteristics. The attenuation coefficient and detector efficiency strongly depend on the energy of x-ray photons. In relation to this, this paper presents the spectral characteristics of a typical x-ray system used for void fraction measurement in two-phase flows. The photon-energy-dependent efficiency of the detector is determined by a calibration test. (authors)
The ability to design, build, and test miniaturized acoustic treatment panels on scale-model fan rigs representative of the full-scale engine provides not only a cost-savings, but an opportunity to optimize the treatment by allowing tests of different designs. To be able to use scale model treatment as a full-scale design tool, it is necessary that the designer be able to reliably translate the scale model design and performance to an equivalent full-scale design. The primary objective of the study presented in this volume of the final report was to conduct laboratory tests to evaluate liner acoustic properties and validate advanced treatment impedance models. These laboratory tests include DC flow resistance measurements, normal incidence impedance measurements, DC flow and impedance measurements in the presence of grazing flow, and in-duct liner attenuation as well as modal measurements. Test panels were fabricated at three different scale factors (i.e., full-scale, half-scale, and one-fifth scale) to support laboratory acoustic testing. The panel configurations include single-degree-of-freedom (SDOF) perforated sandwich panels, SDOF linear (wire mesh) liners, and double-degree-of-freedom (DDOF) linear acoustic panels.
A large scale (2 in.-wide test vanes at 50-in. inlet diameter), low speed (100-200 ft/sec) steady flow radial cascade wind tunnel for diffuser studies was designed, built and tested. The apparatus was shown to provide flow angles (from radial) in the range of 58-72 deg with suitable spanwise profiles. The novel flow angle control mechanism was shown to work, but measured flow angles were somewhat smaller than expected. The mechanism for controlling case-wall boundary layer profile did not behave as predicted. Attempts to predict the generated flow both analytically and with computational codes are compared with initial measurements. The low speed apparatus will be used to obtain detailed data for diffuser design and analysis code verification, and to provide experience toward the design of a high speed device.
Here, elliptic flow measurements from two-, four- and six-particle correlations are used to investigate flow fluctuations in collisions of U+U at $\sqrt{s_{NN}}$ = 193 GeV, Cu+Au at $\sqrt{s_{NN}}$ = 200 GeV and Au+Au spanning the range $\sqrt{s_{NN}}$ = 11.5 - 200 GeV. The measurements show a strong dependence of the flow fluctuations on collision centrality, a modest dependence on system size, and very little if any, dependence on particle species and beam energy. The results, when compared to similar LHC measurements, viscous hydrodynamic calculations, and Glauber model eccentricities, indicate that initial-state-driven fluctuations predominate the flow fluctuations generated in the collisions studied.
In-like transducers system measures flow rate of chemically active propellant fluids. The system uses one low-flow transducer and one high-flow transducer. Each consists of separate heater and temperature-sensing elements.
A new velocity measurement technique is described that provides the simultaneous visualization of a two-dimensional streamline pattern and the quantification of the velocity field. The main advantage of this technique is that the velocity field can be measured with sufficient accuracy and spatial resolution so that the vorticity field can be readily obtained. This technique is ideally suited for the study of unsteady vortical flows, which occur in rotorcraft and in high-angle-of-attack aerodynamics. The technique, some of the important parameters that affect its use, and some recent examples are described.
The Prototype Material Plasma Exposure eXperiment (Proto-MPEX) at Oak Ridge National Laboratory is developing a helicon radio frequency (RF) source for plasma production along with microwave electron heating and RF ion heating. Proto-MPEX has several magnetic mirrors that affect plasma transport. The magnetic field near the helicon source is ~ 0.05 T, and the peak magnetic field in Proto-MPEX is ~ 1.8 T, which results in a large magnetic well for particles sourced at the helicon transporting toward the target region. Keeping the helicon source field and the target field constant, experiments have been conducted by methodically changing the magnetic field, at a local axial location, within the source and the target. Plasma flow measurements using Mach probes have shown a decrease in the flow as a function of the magnetic mirror ratio. Plasma flows were further investigated with ion cyclotron resonant heating (ICH). Results with the addition of ICH measured upstream of the antenna have shown a decrease in Mach number as a function of mirror ratio when compared to helicon discharges. Such flow behavior demonstrated slowing down of the plasma due to the increased reverse plasma flow toward the helicon plasma source. However, in high magnetic fields, when the resonant magnetic field moved away from the ICH antenna, no effects on the plasma flow due to ICH were observed.
The two-phase Taylor flow pattern has been studied extensively. However, limited information is available for flows in intermediate diameter channels (5 ≲ Bo ≲ 40, or 6mm ≲ D ≲ 27mm for ambient gas–water flows), as found in air-lift and bubble pumps. Previous investigations have primarily evaluated Taylor flow models in terms of overall pressure drop, which incorporates hydrostatic and multiple hydrodynamic components. Thus, individual sub-models and sources of error could not be directly assessed. Here in this investigation, volume-of-fluid (VOF) based Taylor flow simulations are performed over a wide range of laminar and turbulent conditions in the intermediate Bond number regime (5 < Bo < 20, 250 < N f < 1000, and 20 < Re j < 8100). Results are applied to individually evaluate hydrodynamic sub-models for bubble-region frictional pressure drop gradient (∇p f,b ), slug frictional pressure drop gradient (∇p f,s ), and flow transition pressure loss (Δp trans ). Based on these results, recommendations are provided for selection of hydrodynamic sub-models. These hydrodynamic closure models are integrated with kinematic flow models to yield a complete intermediate Bond number Taylor flow formulation for which all submodels were independently validated. The resulting model achieves improved accuracy for predicting experimental liquid flow rates compared with previous Taylor flow models (81% of cases within 50% of measured flows rates).
Reliable estimations of the relative permeability of gas and water in hydrate-bearing sediments (HBS) and the dependency of the relative permeability on hydrate saturation are critical to predict the productivity of a hydrate reservoir. Yet, this remains poorly estimated owing to lack of experimental data associated with difficulties in conducting multiphase flow experiments in HBS. Recognizing the experimental challenges, this study intends to develop and validate a new experimental system and procedure of unsteady-state relative permeability test that can generate reliable and reproducible flow measurements in HBS. Furthermore, gas hydrate is considered as a part of solid matrix in the sediment, so one of the challenges is to maintain a constant hydrate saturation, which is achieved in this experimental study using tight pressure-temperature (P-T) control near the hydrate stability boundary. The measured differential pressure across the specimen, methane injection flow rate, and volume of displaced brine are used to calculate the relative permeability by adopting a conventional Buckley-Leverett theory-based interpretation method. Residual brine saturation calculated for the hydrate-bearing specimen is higher than that of hydrate-free specimen, presumably due to decrease in pore size, increase in heterogeneity of solid matrix, and increase in size distribution of solid matrix and pore in the presence of hydrates. Further studies are necessary to represent the results of the unsteady-state flow experiment in HBS with a gas hydrate-dependent relative permeability model.