Search NASA⌕ Search

SEARCH · Search NASA

Results for “Flow meter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Key Observations and Discoveries from the Vector Electric Field Investigation on the C/NOFS Satellite

Launched in 2008 and operating for 7.5 years, the Air Force Communication /Navigation Outage Forecasting System (C/NOFS) satellite included the Vector Electric Field Investigation (VEFI) designed and built at NASA’s Goddard Space Flight Center. VEFI successfully met its objectives: 1) investigate the role of ambient electric fields in initiating nighttime density depletions and turbulence; 2) determine the quasi-DC electric fields associated with abrupt density depletions, and 3) quantify the spectrum of the irregularities associated with density depletions, providing many key observations and discoveries including: -- Global (low latitude) vector DC electric fields at 16 s/sec revealing variations with local time, longitude, and season between extremely low and moderate solar activity-- Reversed zonal E x B drifts below the F-region ledge at sunset and simultaneous observations of large scale Kelvin-Helmholtz instabilities as seeds of spread-F -- Large expanses of quasi-coherent kilometer-scale vector wave observations (electric field and density) below 450 km and their discovery as a source of scintillations using the C/NOFS GPS -- Reversed zonal DC electric fields and simultaneous observations of afternoon counter electrojet-- Enhanced zonal DC electric fields at sunrise and full vector plasma flow continuity at the terminator-- Vector electric field and density irregularities extending to meter-scales within equatorial plasma depletions -- Intense electric field structure within the equatorial ionosphere at night in the absence of density depletions -- First observations of the westward equatorial electrojet in post-midnight ionosphere and possible association with downward meridional drifts-- Spaceborne Dst observations and implications for ring current asymmetries-- Vector electric and magnetic field Poynting flux within depletions and TIDs-- Measurements of ionospheric reflectance and Alfvenic waves associated with TIDs-- Observations of Alfven resonators -- ULF magnetic field structure within the nightime equatorial ionosphere-- Discovery of Schumman resonances in space and implications of ELF radiowave propagation-- Vector observations of 50-60 Hz powerline radiation without harmonics-- Ion cyclotron resonance absorption lines associated with ELF hiss and the identification of ambient ions-- Parallel electric fields associated with lower hybrid waves driven by thunderstorm lightning-related sferics-- Discovery of Z-mode radiation in the equatorial ionosphere including its associated with density depletions-- Optical lightning detector waveforms and electric field sferics observed up to altitudes of 800 km

Robert F Pfaff↗

An Experimental Flow-Through Assessment of Acidic Fe/Mg Smectite Formation on Early Mars

Orbital observations have detected the phyllosilicate smectite in layered material hundreds of meters thick, intracrater depositional fans, and plains sediments on Mars; however, the detection of carbonate deposits is limited. Instead of neutral/alkaline conditions during the Noachian, early Mars may have experienced mildly acidic conditions derived from volcanic acid-sulfate solutions that allowed Fe/Mg smectite formation but prevented widespread carbonate formation. The detection of acid sulfates (e.g., jarosite) associated with smectite in Mawrth Vallis supports this hypothesis. Previous work demonstrated smectite (saponite) formation in closed hydrologic systems (batch reactor) from basaltic glass at pH 4 and 200°C (Peretyazhko et al., 2016 GCA). This work presents results from alteration of basaltic glass from alkaline to acidic conditions in open hydrologic systems (flow-through reactor). Preliminary experiments exposed basaltic glass to deionized water at 190°C at 0.25 ml/min where solution pH equilibrated to 9.5. These initial high pH experiments were conducted to evaluate the flow-through reactor system before working with lower pHs. Smectite at this pH was not produced and instead X-ray diffraction results consistent with serpentine was detected. Experiments are in progress exposing basaltic glass from pH 8 down to pH 3 to determine what range of pHs could allow for smectite formation in this experimental opensystem. The production of smectite under an experimental open-system at low pHs if successful, would support a significant paradigm shift regarding the geochemical evolution of early Mars: Early Mars geochemical solutions were mildly acidic, not neutral/alkaline. This could have profound implications regarding early martain microbiology where acid conditions instead of neutral/alkaline conditions will require further research in terrestrial analogs to address the potential for biosignature preservation on Mars.

Sutter, Brad↗

Machine Learning Based Network Parameter Estimation Using AMI Data

The expansion of distribution power system and the growing penetration of distributed energy resources present new challenges for situational awareness. Calibrating the extended system model with sensor measurements and maintaining the usability is critical for utilities. This paper presents a distribution network parameter estimation (DNPE) approach using machine learning (ML) and metering data that improve the quality of extended distribution power system modeling. The reliability model can improve the ability of endpoint data to be translated into network-level situational awareness in real time and help distribution system operators (DSOs) solve branch flow and voltage problems. In addition, a data analytic and automate processing scheme is proposed to improve the sensor data quality and prevent misleading information. The effectiveness of the proposed method is verified with actual advanced metering infrastructure (AMI) data on a real utility feeder model, while considering the higher penetration of photovoltaic power generation. The test of DNPE and study results are demonstrated in this paper.

Parameter estimation, machine learning, power dist↗

Measuring water velocity using DIDSON and image cross-correlation techniques

To design or operate hydroelectric facilities for maximum power generation and minimum ecological impact, it is critical to understand the biological responses of fish to different flow structures. However, information is still lacking on the relationship between fish behavior and flow structures despite many years of research. Existing field characterization approaches conduct fish behavior studies and flow measurements separately and coupled later using statistical analysis. These types of studies, however, lack a way to determine the specific hydraulic conditions or the specific causes of the biological response. The Dual-Frequency Identification Sonar (DIDSON) has been in wide use for fish behavior studies since 1999. The DIDSON can detect acoustic targets at long ranges in dark or turbid dark water. PIV is a state-of-the-art, non-intrusive, whole-flow-field technique, providing instantaneous velocity vector measurements in a whole plane using image cross-correlating techniques. There has been considerable research in the development of image processing techniques associated with PIV. This existing body of knowledge is applicable and can be used to process the images taken by the DIDSON. This study was conducted in a water flume which is 9 m long, 1.2 m wide, and 1.2 m deep when filled with water. A lab jet flow was setup as the benchmark flow to calibrate DIDSON images. The jet nozzle was 6.35 cm in diameter and core jet velocity was 1.52 m/s. Different particles were used to seed the flow. The flow was characterized based on the results using Laser Doppler Velocimetry (LDV). A DIDSON was mounted about 5 meters away from the jet nozzle. Consecutive DIDSON images with known time delay were divided into small interrogation spots after background was subtracted. Across-correlation was then performed to estimate the velocity vector for each interrogation spot. The estimated average velocity in the core zone was comparable to that obtained using a LDV. This proof-of-principle project demonstrated the feasibility of extracting water flow velocity information from underwater DIDSON images using image cross-correlation techniques.

13 HYDRO ENERGY↗

Modeling Gas Transport in the Shallow Subsurface During the ZERT CO2 Release Test

We used the multiphase and multicomponent TOUGH2/EOS7CA model to carry out predictive simulations of CO{sub 2} injection into the shallow subsurface of an agricultural field in Bozeman, Montana. The purpose of the simulations was to inform the choice of CO{sub 2} injection rate and design of monitoring and detection activities for a CO{sub 2} release experiment. The release experiment configuration consists of a long horizontal well (70 m) installed at a depth of approximately 2.5 m into which CO{sub 2} is injected to mimic leakage from a geologic carbon sequestration site through a linear feature such as a fault. We estimated the permeability of the soil and cobble layers present at the site by manual inversion of measurements of soil CO{sub 2} flux from a vertical-well CO{sub 2} release. Based on these estimated permeability values, predictive simulations for the horizontal well showed that CO{sub 2} injection just below the water table creates an effective gas-flow pathway through the saturated zone up to the unsaturated zone. Once in the unsaturated zone, CO{sub 2} spreads out laterally within the cobble layer, where liquid saturation is relatively low. CO{sub 2} also migrates upward into the soil layer through the capillary barrier and seeps out at the ground surface. The simulations predicted a breakthrough time of approximately two days for the 100kg d{sup -1} injection rate, which also produced a flux within the range desired for testing detection and monitoring approaches. The seepage area produced by the model was approximately five meters wide above the horizontal well, compatible with the detection and monitoring methods tested. For a given flow rate, gas-phase diffusion of CO{sub 2} tends to dominate over advection near the ground surface, where the CO{sub 2} concentration gradient is large, while advection dominates deeper in the system.

54 ENVIRONMENTAL SCIENCES↗

The Study of Electromagnetic Field Response Using Very Low Frequency Methods in Geothermal Area, Sabang

Electromagnetic field measurements have been performed using the method of Very Low Frequency tilt angle pattern in Jaboi, Sabang. A site survey was conducted and carried out to identify the anomalies of location, depth and geometry of hydrothermal based on tilt angle measurement and ellipse. Objective of this study is to see the response of the magnetic and electric field in relation to location, depth and hydrothermal geometry. The devices of T-VLF-R IRIS was used in this study, while the (NWC) station was selected as main station and (JJF4) station was selected as comparison station. The electromagnetic field survey was recorded for a line spanned as long as 900 meters at the interval of 10 meter depth. The results of this study show the greatest anomaly occurred at line interval between 400-600 meters with a depth of 10-140 meters. Anomaly pattern of each depth shows that the propagation pattern of hydrothermal is in the form of vertical pipe flow.

58 GEOSCIENCES↗

Learning Distribution Grid Topologies: A Tutorial

Unveiling feeder topologies from data is of paramount importance to advance situational awareness and proper utilization of smart resources in power distribution grids. This tutorial summarizes, contrasts, and establishes useful links between recent works on topology identification and detection schemes that have been proposed for power distribution grids. The primary focus is to highlight methods that overcome the limited availability of measurement devices in distribution grids, while enhancing topology estimates using conservation laws of power-flow physics and structural properties of feeders. Grid data from phasor measurement units or smart meters can be collected either passively in the traditional way, or actively, upon actuating grid resources and measuring the feeder's voltage response. Analytical claims on feeder identifiability and detectability are reviewed under disparate meter placement scenarios. Such topology learning claims can be attained exactly or approximately so via algorithmic solutions with various levels of computational complexity, ranging from least-squares fits to convex optimization problems, and from polynomial-time searches over graphs to mixed-integer programs. Although the emphasis is on radial single-phase feeders, extensions to meshed and/or multiphase circuits are sometimes possible and discussed. Here this tutorial aspires to provide researchers and engineers with knowledge of the current state-of-the-art in tractable distribution grid learning and insights into future directions of work.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Performance tests of a gas blending system based on mass-flow controllers

The system provides many of the gas mixtures required for calibrating analytical instruments used in engine exhaust gas analysis and is capable of blending from one to four additive gases with either of two carrier gases in concentrations from 20 ppm to 50%. Two mixtures can be flowing simultaneously. Performance tests were made to determine the stability accuracy of the system while it was in limited use for a period of 2 years. The accuracy of the blender was measured by comparing binary mixtures from the blender with National Bureau of Standards standard reference materials. Analytical instruments were used to make these comparisons. The expected accuracy of 2% was obtained in some of the tests, by the majority showed a systematic biAs of -5%. Although these tests revealed subtle instabilities in the flow controllers that contributed to the random scatter of data, the accuracy of wet test meters and bubble flowmeters used for calibration is marginal for this purpose. A simple procedure is recommended that should enable the full potential of the system to be realized.

Evans, A., Jr.↗

Along-strike magma mixing beneath mid-ocean ridges - Effects on isotopic ratios

The effects of mixing processes on the isotopic variability of midocean ridge basalts are studied. The processes considered are porous flow dispersion and convective mixing in magma chambers. Porous flow dispersion is capable of mixing magmas over distances of only a few tens of meters. Convective mixing, on the other hand, is found to produce continuous magma chambers, where mixing is limited by convective processes, and for discontinuous chambers, where mixing is limited by chamber size. Preliminary comparison of the calculations with observations along the midocean ridges shows that the calculations are consistent with the existence of a correlation between bathymetry and isotopic ratio at long, but not at short, wavelengths. They are also capable of explaining a decrease in isotopic variability with increasing spreading rate.

Kenyon, P. M.↗

Subsurface energy storage and transport for solar-powered geysers on Triton

The location of active geyser-like eruptions and related features close to the current subsolar latitude on Triton suggests a solar energy source for these phenomena. Solid-state greenhouse calculations have shown that sunlight can generate substantially elevated subsurface temperatures. A variety of models for the storage of solar energy in a subgreenhouse layer and for the supply of gas and energy to a geyser are examined. 'Leaky greenhouse' models with only vertical gas transport are inconsistent with the observed upper limit on geyser radius of about 1.5 km. However, lateral transport of energy by gas flow in a porous N2 layer with a block size on the order of a meter can supply the required amount of gas to a source region about 1 km in radius. The decline of gas output to steady state may occur over a period comparable with the inferred active geyser lifetime of 5 earth years. The required subsurface permeability may be maintained by thermal fracturing of the residual N2 polar cap. A lower limit on geyser source radius of about 50 to 100 m predicted by a theory of negatively buoyant jets is not readily attained.

Kirk, Randolph L.↗

Experimental study of a vortex-shedding flowmeter

A prototype of a vortex-shedding flowmeter with no moving parts is investigated for the loading of hypergolic fuels into the Space Shuttle Orbiter. Eliminating moving parts is intended to reduce the need for servicing the meter, and the vortex shedder is compared to the turbine flowmeter presently in use. A flow test loop is designed and employed to conduct experimental investigations in which the output characteristics are examined. The relationship between vortex frequency and flow rate is almost linear, as is the relationship between vortex shedding frequency and the Reynolds and Strouhal numbers. The results are consistent with calculations and suggest that the flowmeter is a possible replacement for measuring the loading of hypergols into the Space Shuttle Orbiter.

Thinh, Ngo D.↗

Performance of the Bowen ratio systems on a 22 deg slope

The Bowen ratio energy balance technique was used to assess the energy fluxes on inclined surfaces during the First ISLSCP Field Experiment (FIFE). Since air flow over sloping surface may differ from that over flat terrain, it is important to examine whether Bowen ratio measurements taken on sloping surfaces are valid. In this study, the suitability of using the Bowen ratio technique on sloping surfaces was tested by examining the assumptions that the technique requires for valid measurements. This was accomplished by studying the variation of Bowen ratio measurements along a selected slope at the FIFE site. In September 1988, four Bowen ratio systems were set up in a line along the 22 degree north-facing slope with northerly air flow (wind went up the slope). In July of 1989, six Bowen ratio systems were similarly installed with southerly air flow (the wind went down slope). Results indicated that, at distances between 10 to 40 meters from the top of the slope, no temperature or vapor pressure gradient parallel to the slope was detected. Uniform Bowen ratio values were obtained on the slope, and thus the sensible or latent heat flux should be similar along the slope. This indicates that the assumptions for valid flux measurements are reasonably met at the slope. The Bowen ratio technique should give the best estimates of the energy fluxes on slopes similar to that in this study.

Nie, D.↗

Planar Doppler Velocimetry for Large-Scale Wind Tunnel Applications

Planar Doppler Velocimetry (PDV) concepts using a pulsed laser are described and the obtainable minimum resolved velocities in large-scale wind tunnels are evaluated. Velocity-field measurements are shown to be possible at ranges of tens of meters and with single pulse resolutions as low as 2 m/s. Velocity measurements in the flow of a low-speed, turbulent jet are reported that demonstrate the ability of PDV to acquire both average velocity fields and their fluctuation amplitudes, using procedures that are compatible with large-scale facility operations. The advantages of PDV over current Laser Doppler Anemometry and Particle Image Velocimetry techniques appear to be significant for applications to large facilities.

McKenzie, Robert L.↗

NextGen Operational Improvements: Will they Improve Human Performance

Modernization of the National Airspace System depends critically on the development of advanced technology, including cutting-edge automation, controller decision-support tools and integrated on-demand information. The Next Generation Air Transportation System national plan envisions air traffic control tower automation that proposes solutions for seven problems: 1) departure metering, 2) taxi routing, 3) taxi and runway scheduling, 4) departure runway assignments, 5) departure flow management, 6) integrated arrival and departure scheduling and 7) runway configuration management. Government, academia and industry are simultaneously pursuing the development of these tools. For each tool, the development process typically begins by assessing its potential benefits, and then progresses to designing preliminary versions of the tool, followed by testing the tool's strengths and weaknesses using computational modeling, human-in-the-loop simulation and/or field tests. We compiled the literature, evaluated the methodological rigor of the studies and served as referee for partisan conclusions that were sometimes overly optimistic. Here we provide the results of this review.

Beard, Bettina L.↗

Standoff trace explosives vapor detection at meter distances

Vapor detection is a noncontact sampling method, which is a less invasive means of explosives screening than physical swiping. Explosive vapor detection is a challenge due to the low levels of vapors available for detection. This study demonstrates that the parts-per-quadrillion sensitivity of atmospheric flow tube-mass spectrometry (AFT-MS) combined with a high-volume air sampler enables standoff detection of trace explosives vapor at distances of centimeters to meters. Standoff detection of explosives vapor was possible both upstream and downstream of the vapor source relative to room air currents. RDX vapor from a saturated source was detected at up to 2.5 m. Vapors from RDX residue and nitroglycerin residue were detected at distances up to 0.5 m. The sampling can be optimized by accounting for air movement in the room or environment, which could further extend standoff detection distances. In conclusion, using AFT-MS with a high-volume sampler could also be effective for standoff vapor detection of drugs and additional chemical threats and could be useful for security screening applications such as at mail facilities, border crossings, and security checkpoints.

47 OTHER INSTRUMENTATION↗

Experimental study of a free turbulent shear flow at Mach 19 with electron-beam and conventional probes

An experimental study of the initial development region of a hypersonic turbulent free mixing layer was made. Data were obtained at three stations downstream of a M = 19 nozzle over a Reynolds range of 1.3 million to 3.3 million per meter and at a total temperature of about 1670 K. In general, good agreement was obtained between electron-beam and conventional probe measurements of local mean flow parameters. Measurements of fluctuating density indicated that peak root-mean-square (rms) levels are higher in the turbulent free mixing layer than in boundary layers for Mach numbers less than 9. The intensity of rms density fluctuations in the free stream is similar in magnitude to pressure fluctuations in high Mach number flows. Spectrum analyses of the measured fluctuating density through the shear layer indicate significant fluctuation energy at the lower frequencies (0.2 to 5 kHZ) which correspond to large-scale disturbances in the high-velocity region of the shear layer.

Harvey, W. P.↗

Dynamic Arrival Routes: A Trajectory-Based Weather Avoidance System for Merging Arrivals and Metering

Convective weather can cause arrival traffic to fly less efficient weather avoidance routes and is the primary cause for time-based metering to be discontinued. Dynamic Arrival Routes (DAR) is a trajectory-based weather avoidance system that is designed to help improve arrival traffic flow when weather is present. The DAR system continuously analyzes airborne arrival flights for opportunities to reroute them to more efficient arrival routes or around weather that is predicted to be on their current flight plan early enough to allow the arrival time-based metering system to adjust its times of arrival for the presence of weather. Analysis of 93 hours of actual traffic over 12 different days from Fort Worth Center showed DAR proposed more efficient arrival reroutes for 352 arrival flights for an average time savings of 12.3 minutes per flight at a look-ahead time of 60 minutes from the meter fix. DAR also identified 642 arrival flights with a need to deviate around weather and proposed weather avoidance routes that were analytically shown to remain weather-free 83 percent of the time for a look-ahead time of 30 minutes from the meter fix.

Arrivals↗

West Flank Coso FORGE: 3D Temperature Model

x,y,z data of the 3D temperature model for the West Flank Coso FORGE site. Model grid spacing is 250m. The temperature model for the Coso geothermal field used over 100 geothermal production sized wells and intermediate-depth temperature holes. At the near surface of this model, two boundary temperatures were assumed: (1) areas with surface manifestations, including fumaroles along the northeast striking normal faults and northwest striking dextral faults with the hydrothermal field, a temperature of ~104 deg C was applied to datum at +1066 meters above sea level elevation, and (2) a near-surface temperature at about 10 meters depth, of 20 deg C was applied below the diurnal and annual conductive temperature perturbations. These assumptions were based on heat flow studies conducted at the CVF and for the Mojave Desert. On the edges of the hydrothermal system, a 73 deg C/km temperature gradient contour was established using conductive gradient data from shallow and intermediate-depth temperature holes. This contour was continued to all elevation datums between the 20 deg C surface and -1520 meters below mean sea level. Because the West Flank is outside of the geothermal field footprint, during Phase 1, the three wells inside the FORGE site were incorporated into the preexisting temperature model. To ensure a complete model was built based on all the available data sets, measured bottom-hole temperature gradients in certain wells were downward extrapolated to the next deepest elevation datum (or a maximum of about 25% of the well depth where conductive gradients are evident in the lower portions of the wells). After assuring that the margins of the geothermal field were going to be adequately modelled, the data was contoured using the Kriging method algorithm. Although the extrapolated temperatures and boundary conditions are not rigorous, the calculated temperatures are anticipated to be within ~6 deg C (20 deg F), or one contour interval, of the observed data within the Coso geothermal field. Based on a lack of temperature data west of 74-2TCH, the edges of this model still seem to have an effect on West Flank modeled temperatures.

15 GEOTHERMAL ENERGY↗