Inter-Calibrating the CERES SW Instrument Fluxes Using Deep Convective Clouds(DCC) Within the Same Sun-Synchronous Orbit

The NASA CERES EBAF product provides the scientific community observed TOA fluxes to monitor the Earth’s energy imbalance and to validate climate models. To provide a seamless EBAF 24-year record, the CERES instrument calibration must be stable and consistent across satellite records. Once the Terra and Aqua spacecraft are decommissioned at the end of 2025, the CERES project will rely on CERES instrument observations on the SNPP and NOAA-20 1:30 PM sun-synchronous orbits. The SNPP and NOAA-20 satellite orbit placement will prevent any time matched observations for inter-calibration efforts. The future Libera instrument, which will continue the CERES record and scheduled for launch in 2028 onboard the NOAA-22 satellite, will also need to be inter-calibrated without the aid of time-matched observations. Deep convective clouds (DCC) are the most Lambertian, brightest, tropical Earth invariant targets located at the tropopause making them ideal to radiometrically scale the CERES SW observed radiance to a common reference. The SNPP, NOAA-20 and future NOAA-22 satellites are in the same 16-day repeatable orbits, allowing the DCC targets to be observed with the same angular configuration. The empirically derived SNPP CERES SW channel Bidirectional Reflectance Distribution Function (BRDF) can be easily be applied to the NOAA-20 CERES SW channel radiances since they observe the nearly the same DCC systems. The DCC BRDF corrected radiances are analyzed collectively into radiance probability distribution functions (PDF). By comparing the PDF statistics, the SNPP and NOAA-20 CERES SW channel can be inter-calibrated. The inter-calibration coefficients are validated with the CERES instrument calibration team coefficients to optimize the methodology.

David Doelling↗

Planned Steady State Irradiation of Characterized Instruments for Nuclear Thermal Rockets Using In-Pile Experiment Apparatus

The development of nuclear rocket technology is critical for the further exploration of extraterrestrial bodies. Nuclear rockets are capable of providing various advantages over current chemical rockets. However, the harsh environment provides a number of challenges regarding instrument performance. Temperature extremes, radiation (reactor and space), and the inability to conduct traditional maintenance activities can lead to a severe degradation in instrument performance. To better understand the effects of radiation on instrumentation, an irradiation campaign has been designed to test a set of instruments provided by a collaborator in the aerospace industry. Details concerning pre-irradiation performance are provided for a future comparison to the irradiated performance. Additionally, the design of the irradiation test is described in detail.

Floyd, Dan↗

Radiation hardened beam instrumentations for multi-Mega-Watt beam facilities

The radiation hardened beam instrumentations workshop was held on February 3rd and 4th, 2022 to identify the technological challenges on the beam instrumentation for multi-Mega-Watt (MW) beam facilities. We invited a speaker from a high energy neutrino beam facility (CERN, Fermilab and J-PARC), a collider detector group (CERN and Fermilab), a neutron spallation source facility (ESS, J-PARC and SNS), and a rare-isotope beam facility (FRIB). Although, the operational beam parameter for each institution is unique due to their different physics goals, we realize that there is a common issue on the beam instrumentation. Therefore, it will be tackled by a collaborative R&D effort among facilities. We summarize an output from the workshop in the paper, and propose a possible R&D for the future radiation hardened beam instrumentations with a global effort.

43 PARTICLE ACCELERATORS↗

Using an onion like neutron scattering instrument model to quickly optimize design parameters

When designing a neutron scattering instrument, one of the major challenges is the many parameters, generally interdependent, within the optimization. In this work we describe an approach using McStas 1-3 to quickly get a good overview of how changes in instrument parameters will impact neutron scattering instrument performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Instrument for in situ hard x-ray nanobeam characterization during epitaxial crystallization and materials transformations

Solid-phase epitaxy (SPE) and other three-dimensional epitaxial crystallization processes pose challenging structural and chemical characterization problems. The concentration of defects, the spatial distribution of elastic strain, and the chemical state of ions each vary with nanoscale characteristic length scales and depend sensitively on the gas environment and elastic boundary conditions during growth. The lateral or three-dimensional propagation of crystalline interfaces in SPE has nanoscale or submicrometer characteristic distances during typical crystallization times. Here, an in situ synchrotron hard x-ray instrument allows these features to be studied during deposition and crystallization using diffraction, resonant scattering, nanobeam and coherent diffraction imaging, and reflectivity. The instrument incorporates a compact deposition system allowing the use of short-working-distance x-ray focusing optics. Layers are deposited using radio-frequency magnetron sputtering and evaporation sources. The deposition system provides control of the gas atmosphere and sample temperature. The sample is positioned using a stable mechanical design to minimize vibration and drift and employs precise translation stages to enable nanobeam experiments. Results of in situ x-ray characterization of the amorphous thin film deposition process for a SrTiO 3 /BaTiO 3 multilayer illustrate implementation of this instrument.

47 OTHER INSTRUMENTATION↗

Innovative sensing technologies for nuclear instrumentation

The Idaho National Laboratory (INL) is engaged in research and development activities for the development of nuclear instrumentation that contribute to advances in measurement methodologies, measurement systems, instrumentation, and sensors in the area of nuclear engineering. The activities described in this paper are centered on the INL Measurement Science Department, which was formed in 2018. Their mission is to develop instrumentation that provides real time, accurate, spatially resolved information regarding test conditions and the performance of fuels and materials during irradiation. This paper describes the integration of innovative optical fiber, acoustic and electrical impedance sensing technologies and measurement techniques as part of the activities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

FY19 Report for Instrumentation Development for the Transient Testing Program

This report details the technical activities and accomplishment carried out under funding from the Department of Energy (DOE) Nuclear Technology Research and Development (NTRD) program for in-pile instrumentation supporting the transient testing program in FY19. These activities were performed in support of cross-cutting transient testing experiment objectives. The purpose of this report is to provide a summary of key technical work, of particular interest to nuclear irradiation test experimenters and in-pile instrumentation engineers. During FY19, development activities are focused on deployment of devices to perform online measurement of neutron flux, temperature, and mechanical behaviors in nuclear fuels experiments. Specifically, these R&D activities include in-pile investigations at the Transient Reactor Test (TREAT) facility throughout the year. Other in-pile instrumentation R&D activities are being carried out under other DOE programs, which may be recognized but not the focus of this document. A brief summary of activities and accomplishments is first provided for each major activity. More detailed summaries are presented in appendices.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Simultaneous Momentum and Position Measurement and the Instrumental Weyl-Heisenberg Group

The canonical commutation relation, [Q,P]=iℏ, stands at the foundation of quantum theory and the original Hilbert space. The interpretation of P and Q as observables has always relied on the analogies that exist between the unitary transformations of Hilbert space and the canonical (also known as contact) transformations of classical phase space. Now that the theory of quantum measurement is essentially complete (this took a while), it is possible to revisit the canonical commutation relation in a way that sets the foundation of quantum theory not on unitary transformations but on positive transformations. This paper shows how the concept of simultaneous measurement leads to a fundamental differential geometric problem whose solution shows us the following. The simultaneous P and Q measurement (SPQM) defines a universal measuring instrument, which takes the shape of a seven-dimensional manifold, a universal covering group we call the instrumental Weyl-Heisenberg (IWH) group. The group IWH connects the identity to classical phase space in unexpected ways that are significant enough that the positive-operator-valued measure (POVM) offers a complete alternative to energy quantization. Five of the dimensions define processes that can be easily recognized and understood. The other two dimensions, the normalization and phase in the center of the IWH group, are less familiar. The normalization, in particular, requires special handling in order to describe and understand the SPQM instrument.

47 OTHER INSTRUMENTATION↗

The Mars Exploration Rover Instrument Positioning System

During Mars Exploration Rover (MER) surface operations, the scientific data gathered by the in situ instrument suite has been invaluable with respect to the discovery of a significant water history at Meridiani Planum and the hint of water processes at work in Gusev Crater. Specifically, the ability to perform precision manipulation from a mobile platform (i.e., mobile manipulation) has been a critical part of the successful operation of Spirit and Opportunity rovers. As such, this paper describes the MER Instrument Positioning System that allows the in situ instruments to operate and collect their important science data using a robust, dexterous robotic arm combined with visual target selection and autonomous software functions.

in situ instruments↗

Self-Supplied Liquid Injection Field Desorption/Ionization Ion Source for an Orthogonal Time-of-Flight Instrument

A new implementation of a dedicated ion source for field ionization (FI), field desorption (FD), and liquid injection field desorption/ionization (LIFDI) for the JEOL AccuTOF GC series of orthogonal-acceleration time-of-flight instruments is presented. In contrast to existing implementations, this third-party LIFDI probe and source combination does not require the exchange of the entire ion source comprising ion source block and lens stack to switch from electron ionization (EI) to LIFDI. Rather, the methods may be swapped conveniently by only exchanging the ion source block for a mechanical probe guide and inserting the LIFDI probe in place of the standard direct insertion probe (DIP) via the vacuum lock. Further, this LIFDI setup does not require any changes of the electronics or software of the AccuTOF mass spectrometer because it is self-supplied in terms of power supply, observation optics, and computer control. The setup offers advanced FI/FD/LIFDI control features such as emission-controlled emitter heating current and emitter flash baking during elongated runs as required for gas chromatography-FI-mass spectrometry (MS). The LIFDI source and probe and its operation are reported in detail. FI spectra of the volatile analytes toluene, heptane, and pentafluoroiodobenzene are presented. LIFDI operation is demonstrated for the analysis of the saturated hydrocarbon dotriacontane and the low-mass hydrocarbon polymers polystyrene 484 and polystyrene 1050. Further, the air-sensitive 2nd-generation Hoveyda–Grubbs catalyst is analyzed by LIFDI-MS. For comparison with long-established LIFDI instrumentation, some of the spectra obtained with the new setup are also compared with those from a double-focusing magnetic sector instrument. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hedonic Price Estimates of Lake Water Quality: Valued Attribute, Instrumental Variables, and Ecological-Economic Benefits

We estimate the effect of lake water quality on residential housing prices using cross-sectional data on water clarity from 113 lakes across the United States. An instrumental-variables approach is developed to address potential endogeneity bias in the water-clarity variable. Three lake-based physical variables serve as instrumental variables: total nitrogen concentration in lake water, total phosphorus concentration in lake water, and water temperature near the lake surface. The econometric results include three methodological findings: the instruments are valid and strong; the ordinary-least-squares estimate of the coefficient on the water-clarity variable is unbiased; and water clarity is the attribute of water quality valued in the housing market. The estimated water-clarity effect shows that a one-tenth of a meter change in water clarity leads to a one-percent change in housing price, or an elasticity of 0.20 at mean clarity. Coupling this effect with estimates of an ecological production function, a lake-specific benefit index is developed that shows the effect on housing values of bringing lakes into compliance with the US Environmental Protection Agency's regional recommendations for phosphorous concentration in lake waters.

54 ENVIRONMENTAL SCIENCES↗

Angular scattering of protons through ultrathin graphene foils: Application for time-of-flight instrumentation

Space plasma instruments often rely on ultrathin carbon foils for incident ion detection, time-of-flight (TOF) mass spectrometry, and ionization of energetic neutral atoms. Angular scattering and energy loss of ions or neutral atoms in the foil can degrade instrument performance, including sensitivity and mass resolution; thus, there is an ongoing effort to manufacture thinner foils. Using new 3-layer graphene foils manufactured at the Los Alamos National Laboratory, we demonstrate that these are the thinnest foils reported to date and discuss future testing required for application in space instrumentation. We characterize the angular scattering distribution for 3–30 keV protons through the foils, which is used as a proxy for the foil thickness. We show that these foils are ~2.5–4.5 times thinner than the state-of-the-art carbon foils and ~1.6 times thinner than other graphene foils described in the literature. We find that the inverse relationship between angular scattering and energy no longer holds, reaffirming that this may indicate a new domain of beam–foil interactions for ultrathin (few-layer) graphene foils.

47 OTHER INSTRUMENTATION↗

First results from a multiplexed and massive instrument with sub-electron noise Skipper-CCDs

Here, we present a new instrument composed of a large number of sub-electron noise Skipper-CCDs operated with a two stage analog multiplexed readout scheme suitable for scaling to thousands of channels. New, thick, 1.35 Mpix sensors, from a new foundry, are glued into a Multi-Chip Module (MCM) printed circuit board on a ceramic substrate which has 16 sensors each. The instrument, that can hold up-to 16 MCMs, a total of 256 Skipper-CCD sensors (called a Super-Module with ≈ 130 grams of active mass and 346 Mpix), is part of the R&D effort of the OSCURA experiment which will have ≈ 94 super-modules. Experimental results with 10 MCMs and 160 Skipper-CCDs sensors are presented in this paper. This is already the largest ever built instrument with single electron sensitivity CCDs using nondestructive readout, both, in terms of active mass and number of channels.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Macromolecular Femtosecond Crystallography Instrument at the Linac Coherent Light Source

The Macromolecular Femtosecond Crystallography (MFX) instrument at the Linac Coherent Light Source (LCLS) is the seventh and newest instrument at the world's first hard X-ray free-electron laser. It was designed with a primary focus on structural biology, employing the ultrafast pulses of X-rays from LCLS at atmospheric conditions to overcome radiation damage limitations in biological measurements. It is also capable of performing various time-resolved measurements. The MFX design consists of a versatile base system capable of supporting multiple methods, techniques and experimental endstations. The primary techniques supported are forward scattering and crystallography, with capabilities for various spectroscopic methods and time-resolved measurements. The location of the MFX instrument allows for utilization of multiplexing methods, increasing user access to LCLS by running multiple experiments simultaneously.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

IRIXS: a resonant inelastic X-ray scattering instrument dedicated to X-rays in the intermediate energy range

A new resonant inelastic X-ray scattering (RIXS) instrument has been constructed at beamline P01 of the PETRA III synchrotron. This instrument has been named IRIXS (intermediate X-ray energy RIXS) and is dedicated to X-rays in the tender-energy regime (2.5–3.5 keV). The range covers the L 2,3 absorption edges of many of the 4delements (Mo, Tc, Ru, Rh, Pd and Ag), offering a unique opportunity to study their low-energy magnetic and charge excitations. The IRIXS instrument is currently operating at the Ru L 3 -edge (2840 eV) but can be extended to the other 4d elements using the existing concept. The incoming photons are monochromated with a four-bounce Si(111) monochromator, while the energy analysis of the outgoing photons is performed by a diced spherical crystal analyzer featuring (10$\bar{2}$ lattice planes of quartz (SiO 2 ). A total resolution of 100 meV (full width at half-maximum) has been achieved at the Ru L 3 -edge, a number that is in excellent agreement with ray-tracing simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Identifying Suspect Instrument Intervals Using Midnight Noise Time Histories

With an intense work ethic, and high levels of devotion to their craft, seismologists continue to battle the elements and wrestle with complex logistics in their efforts to field instrumentation over the entire globe. We are fortunate to see data volumes accelerating in size, and quality continuing to improve; for example, universal timing issues can now be considered rare. However, instrument response issues are still common, and can hinder research that seeks to understand amplitudes of seismic wavefields. We are interested in using the accumulations of seismic data to develop models that will predict high frequency (0.2-20 Hz, and higher) signal amplitudes for explosion monitoring purposes over broad areas, which requires large data sets and extensive quality control. To identify response and station health issues, we have collected noise time histories for global seismic data, focusing on measurements near (but not restricted to) midnight to eliminate diurnal variations, and have manually determined time intervals that appear inconsistent with background behavior. We assign descriptive labels, but do not attempt to diagnose causes. We use these intervals to discard data. To date, we have examined 39,260 channels from 11,105 stations, heavily weighted toward IRIS holdings, dates through 2017 (depending on station, roughly the date we started our manual review), bands between 1 and 8 Hz, finding 24,733 anomalous time intervals. The great majority (90%) of these intervals appear to be shifts of constant offset, often bounded by times of known instrument changes, likely the result of poor documentation of response parameters at one of many stages between the field and the plotter. We hope these results can be of use to our colleagues, and would encourage community efforts to diagnose anomalous behavior, and fix poor responses. We also hope these results will support automation efforts, including application of supervised learning techniques.

47 OTHER INSTRUMENTATION↗

Qualification and Re-Qualification of NDA Instruments

Non-Destructive Assay (NDA) instruments are a large component of nuclear material (NM) measurement at LANL. Nuclear Material Control and Accountability Group (SAFE-NMCA) personnel in the Safeguards Division are responsible for oversight of the instruments used for material accountability measurements. It is the responsibility of SAFE-NMCA to ensure that all instruments are operating as expected and can produce quality measurements to provide assurance that requirements of the DOE approved NMCA Plan are being met.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Analysis and Support for LANL Technology Testbed: High Altitude Balloon Gondola and Orion Eagle Gamma Ray Detection Instrument

The Analysis and Support for LANL Technology Testbed: High Altitude Balloon Gondola and Orion Eagle Gamma-Ray Detection Instrument is a project where Los Alamos National Laboratory (LANL), in conjunction with the University of Michigan, are looking into gamma-ray detection in a space-like environment. The purpose of the detection is to work on instruments that can assist with planetary exploration and nuclear deterrents using a High-Altitude Balloon (HAB). For this paper, the main focus is on the mechanical aspects related to the structural analysis of the gondola. It is vital to understand the structural analysis because it helps determine if the gondola can survive the changes in the environment and the different forces or shocks that it will experience when the parachute is deployed and at landing. Additionally, NASA's Balloon Program Office (BPO) has specific requirements to meet to achieve flight certifications. Part of those certifications requires the gondola to simulate different scenarios at specific conditions with various forces applied and orientations. Therefore, it is necessary to adjust the calculations of each method and the force applied to get the right results. Once that is done, the information is inputted into the structural analysis modeling system. The system will aid the mechanical team in assessing the conditions of the gondola at each scenario and determine its margin of safety. After the gondola and instrument are certified, the payload will be able to fly. The HAB and payload are launched from NASA's Columbia Scientific Balloon Facility (CSBF) at Fort Sumner, NM. The official flight was on September 26th, 2021.

42 ENGINEERING↗