Search NASA⌕ Search

SEARCH · Search NASA

Results for “LOCATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Assessment of the LV-S2 & LV-S3 Stack Sampling Probe Locations for Compliance with ANSI/HPS N13.1-1999

This document reports on a series of tests conducted to assess the proposed air sampling locations for the Hanford Tank Waste Treatment and Immobilization Plant (WTP) Group 1-2A exhaust stacks with respect to the applicable criteria regarding the placement of an air sampling probe. The LV-C2, LV-S2, and LV-S3 exhaust stacks were tested together as a group (Test Group 1-2A). This report only covers the results of LV-S2 and LV-S3; LV-C2 will be reported on separately. Federal regulations1 require that a sampling probe be located in the exhaust stack according to the criteria established by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999, Sampling and Monitoring Releases of Airborne Radioactive Substances from the Stack and Ducts of Nuclear Facilities. 2 These criteria address the capability of the sampling probe to extract a sample that represents the effluent stream.

Glissmeyer, John A.↗

A Triangulation Method for Identifying Hydrostratigraphic Locations of Well Screens

A method to identify the hydrostratigraphic location of well screens was developed using triangulation with known locations. This method was applied to all of the monitor wells being used to develop the new GSA groundwater model. Results from this method are closely aligned with those from an alternate method which uses a mesh surface.

58 GEOSCIENCES↗

Assessment of Leakage Risk from Known Well Locations for the Central Appalachian Basin CarbonSAFE project, Site A and Site B

This reports summaries the probability of CO 2 and brine leakage from known well locations at screening Sites A and B as part of the Phase 1 Central Appalachian Basin CarbonSAFE project using the NRAP-IAMCS. Sites A and B evaluate leakage risk of 50 million tons of CO 2 in two wells into stacked storage reservoirs. There are about 5000 oil and gas wells around each location, drilled between early 1900s to present. In this analysis, we consider only those wells that fall within the area of review and are likely to penetrate the CO 2 storage reservoir.

54 ENVIRONMENTAL SCIENCES↗

Analysis of Microgrid Locations Benefitting Community Resilience for Puerto Rico

An analysis of microgrids to increase resilience was conducted for the island of Puerto Rico. Critical infrastructure throughout the island was mapped to the key services provided by those sectors to help inform primary and secondary service sources during a major disruption to the electrical grid. Additionally, a resilience metric of burden was developed to quantify community resilience, and a related baseline resilience figure was calculated for the area. To improve resilience, Sandia performed an analysis of where clusters of critical infrastructure are located and used these suggested resilience node locations to create a portfolio of 159 microgrid options throughout Puerto Rico. The team then calculated the impact of these microgrids on the region's ability to provide critical services during an outage, and compared this impact to high-level estimates of cost for each microgrid to generate a set of efficient microgrid portfolios costing in the range of $\$218$-$\$917$M. This analysis is a refinement of the analysis delivered on June 01, 2018.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Passively-Powered Adaptively-Located Flexible Hybrid Sensors Final Report

PARC, a Xerox Company, is developing a low-cost system of peel-and-stick wireless sensors that will enable widespread building environment sensor deployment with the potential to deliver up to 30% energy savings. The system is embodied by a set of RF hubs that provide power to the automatically located sensor nodes, and relays data wirelessly to the building management system (BMS). The sensor nodes are flexible electronic labels powered by rectified RF energy transmitted by a RF hub and can contain multiple printed and conventional sensors. The system design overcomes limitations in wireless sensors related to power delivery, lifetime, and cost by eliminating batteries and photovoltaic devices. The sensor label can be equipped with a variety of printed and conventional sensors for building energy optimization, including lighting, occupancy, temperature, humidity, motion, and air quality. A key advantage of this system is its ability to automatically locate multiple sensor nodes to within 0.5 m (at a 5-m read distance) for simplified commissioning, as well as its interoperability with a wide range of existing BMS hardware and software. This enables automatic sensor reconfiguration and recommissioning, which is an important cost reduction driver. Moreover, the sensors are compatible with low-cost-, high-throughput roll-to-roll manufacturing, further reducing system costs. Upon successfully developing, manufacturing and deploying the system with optimized control, it can lead to annual primary energy savings >280 TBtu in offices, and up to ~1850 TBtu in combined offices and residences. The technology is based on PARC innovations in small antenna design, efficient RF energy capture, and flexible electronics. PARC is a leader in flexible hybrid integration similar to what is used in current RFID tags, which will provide a low-cost system in a flexible form factor. Our team member, Energy ETC, is a leader in supplier-agnostic BMS deployments, and will design the commissioning and deployment procedures to maximize system interoperability. The project will result in a demonstrator that will provide temperature and humidity data and will be wirelessly integrated into PARC’s BMS.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

User Location-Specific Data for Smarter Smart Grids

This project focused on modifying and evaluating the Readings at Desk (RAD) controller, a lighting control system developed and patented by Erik Page & Associates, Inc. (EP&A) that: 1) Measures the amount of light present in the workstation; 2) Allows occupants to define desired light levels at the workstation; 3) Communicates to wirelessly-controllable overhead lighting systems. In measuring conditions at the desk, the RAD controller differs from typical lighting control systems that rely on daylight sensors located at the ceiling. There are inherent advantages associated with using sensors that are located at the occupant’s workstation in that they more accurately represent what the occupant is experiencing, theoretically providing a much better closed-loop control point. The technical objectives of this Phase I project were: 1) Objective 1: Modify the RAD controller such that it can report energy use of connected devices and receive status updates and/or commands from external sources, such as grid or demand response signals. 2) Objective 2: Modify the RAD controller to measure the temperature at a workstation, accept temperature preferences from users, and communicate controls information to a building’s HVAC systems. 3) Objective 3: Carry out a comprehensive performance test of the modified RAD controller in controlling lighting and HVAC systems. All three technical objectives were met in the Phase I project execution, as well as an additional “bonus” technical achievement not described in the original proposal: the development of a computer monitor-mounted occupancy and lighting sensor board.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Considerations for the Design of a Gas Transport System for Co-location of Microalgae Cultivation with CO 2 Sources

Co-locating microalgae cultivation facilities with sources of waste CO 2 may present opportunities for cost savings that could benefit the algal biomass industry and industries or utilities that have incentives to manage carbon emissions. However, the cost savings have not been quantified. We compare the cost of utilizing CO 2 from flue gas transported to 405-ha, base-case, open-pond microalgae facilities to the commercial purchase price of CO 2 . Sources of CO 2 include coal- and natural gas-fired power plants and ethanol, ammonia, and cement production plants in the United States. The transport of CO 2 -containing gases to the microalgae cultivation facility requires infrastructure and electricity. This engineering analysis explores the parameters that affect the infrastructure and transport distance over which emitted flue gases can be cost-effectively transported to microalgae cultivation facilities, compared to the cost of commercially purchased CO 2 (i.e., the break-even distance). Parameters that are varied include size of facility pond area, productivity, and daily duration of waste CO 2 emissions that are transported to algae. Under our assumptions and under all cases in this study, cost savings can be achieved by co-locating microalgae facilities near waste CO 2 sources. The break-even distance, which is estimated here to range from under 2 to 80 km, depends primarily on the concentration of CO 2 in flue gas, algae productivity, facility size, and pipeline system design considerations. Greater break-even distances are simulated if electricity cost is minimized, rather than if capital cost is minimized.

09 BIOMASS FUELS↗

Analysis of Microgrid Locations Benefitting Community Resilience for Puerto Rico

An analysis of microgrids to increase resilience was conducted for the island of Puerto Rico. Critical infrastructure throughout the island was mapped to the key services provided by those sectors to help inform primary and secondary service sources during a major disruption to the electrical grid. Additionally, a resilience metric of burden was developed to quantify community resilience, and a related baseline resilience figure was calculated for the area. To improve resilience, Sandia performed an analysis of where clusters of critical infrastructure are located and used these suggested resilience node locations to create a portfolio of 159 microgrid options throughout Puerto Rico. The team then calculated the impact of these microgrids on the region's ability to provide critical services during an outage, and compared this impact to high-level estimates of cost for each microgrid to generate a set of efficient microgrid portfolios costing in the range of 218-917M dollars. This analysis is a refinement of the analysis delivered on June 01, 2018.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High-Precision Measurements of Locations of Nearby Brown Dwarfs

As substellar objects that lack sufficient mass to produce energy by fusion, brown dwarfs are extremely faint celestial objects. Detection of nearby brown dwarfs, however, is possible in the infrared range of wavelengths. In this study, we calculate the locations of nearby brown dwarfs in infrared images. We achieve this goal by processing images collected with the aid of adaptive optics. We describe a pipeline that locates the centers of all objects detected in infrared images of fields containing nearby brown dwarfs. The identified object centers, traced over multiple epochs between 2014 and 2017, can inform us about parallax distances between Earth and the brown dwarfs that interest us.

79 ASTRONOMY AND ASTROPHYSICS↗

Location-Dependent Mechanical Property Evaluation on Additively Manufacture Materials

This report summarizes research activities conducted at Argonne National Laboratory in support of the development, qualification and certification of additively manufactured (AM) metallic components to allow for innovative reactor design and licensing for the Transformational Challenge Reactor (TCR). Focus is on the evaluation of high temperature mechanical properties including creep and fatigue of 316L stainless steel manufactured by the laser powder bed fusion process. Creep behavior of AM 316L stainless steel was evaluated for rods printed by either or a combination of both lasers of the dual-laser system of a Concept Laser-M2 printer to examine the consistency across the build plate. Creep tests were conducted at temperatures of 550, 575, 600, and 650°C and stresses between 175 and 300 MPa using ASTM standard-sized specimens. The effect of heat treatments at different temperatures on creep properties of AM 316L SS was examined to understand the processing-microstructure-property relationship. Fatigue properties of AM 316L SS were investigated for two print geometries (rod and plate) and in two build orientations of printed plates. Locations of specimens in the build were carefully tracked such that the testing data can be directly related to location-specific in situ data to establish links between printing process, post-printing treatment, microstructure and mechanical properties. The work is to support the development of a digital platform informed approach to AM component qualification and certification for nuclear applications.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Assessment of the 3430 Building Filtered Exhaust Stack Sampling Probe Location: Stack Verification Following Fan and Air Blender Additions

The velocity uniformity and flow angle results from the 3430 stack verification tests, performed in April 2023, demonstrated that the CFD model results may be used to support the qualification of the stack sampling location. The measured velocity uniformity verification test result was 2.1 %COV. This value is well within the uniformity criterion, which is that the velocity uniformity be =20 %COV. Additionally, this value is well within the criterion that the actual stack measurement must be within 5% of the surrogate stack (i.e., CFD modeled stack); in this case the CFD modeled average result of 2.85 %COV for the nominal operating range of 22,800 cfm to 62,400 cfm. Additionally, the measured average flow angle at the 3430 stack monitor location was 5.6 degrees. The result is =20 degrees, so the criterion is met.

3430 Building↗

Deploying a Publicly Available and Living National Oil and Gas Well Geodatabase: CO2-Locate: A Dynamic Database & Tool

Emission mitigation and safe geologic carbon storage require an understanding of local wellbore infrastructure, yet well data are siloed across many entities. Addressing this challenge, the National Energy Technology Laboratory published CO2-Locate, an integrated and dynamic national wellbore geodatabase. CO2-Locate offers up to date well data spanning more than 40 federal, state, and tribal entities, as well as spatially summarized insights designed to support commercial, regulatory, and research communities as they strive to curb climate change through a national energy transition.

Pfander, Isabelle↗

Topical Analyses Related to Co-located Industrial Facilities at Nuclear Power Plants

This report investigates topics of interest with regard to Nuclear Power Plants (NPPs) utilizing flexible plant operations and generation (FPOG). Previous reports have identified the risk associated with co-located hydrogen generation facilities. This report evaluates special topics with regard to co-location of both hydrogen and syngas production facilities. A literature review was conducted to evaluate overpressure mitigation techniques that may be available to the NPP to reduce the consequence of an overpressure event. Also, the overpressure consequence of a catastrophic hydrogen storage tank failure event was analyzed. A comparison of the similarities and differences between the methodology utilized in HyRAM+ and Regulatory Guide 1.91 (R.G. 1.91) was performed for overpressure analysis. Also, the trinitrotoluene (TNT) equivalency methodology was utilized to evaluate an overpressure event at a Syngas production facility.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

CO2-Locate: A Living National Well Database

This is a presentation on NETL's CO2-Locate Database, an integrated resource of standardized public well records focusing on oil and gas well data acquired from federal, state, and tribal entities. This presentation covers updates on the resource, the integration method, and how CO2-Locate is being used as a baseline to support cross-cutting infrastructure projects.

Romeo, Lucy↗

Location-Specific Microstructures and Properties of Haynes 282 Alloy with Laser-Wire DED Processing

In this work, the location-specific microstructures in terms of grain morphology, texture, γ′ precipitates, carbides, and residual strains were investigated in a series of laser-wire direct energy deposition (LW-DED) Haynes 282 alloys with varied processing parameters. A bimodal grain distribution was found in these as-printed and heat-treated alloys with columnar grains within the layers and fine equiaxed grains at the interlayer regions. Dominant <001> texture along the build direction with more obvious <111> orientation preference exists at the bottom layers, compared to the top layers. The gradient γ′-precipitates size distribution contributes predominantly to the observed gradient hardness distribution in the as-printed samples. The heat-treated 282 exhibit comparable yield strengths to those conventionally-processed counterparts, while the observed small deviation in their yield strengths is attributed to the Hall-Petch effect. This work establishes the correlation between location-specific microstructures and mechanical properties, providing valuable insights into future printing parameters and heat-treatment optimization.

Haynes 282↗

Considerations for a Co-Located Aquaculture and Wave Energy Deployment: Quantifying Demand and Assessing Integration

The co-location of marine energy and aquaculture is a concept of increasing value and interest in the United States, as the desire for sustainably produced seafood and renewable energy continues to grow. With both industries being fairly nascent in their national development and facing challenges, the deployment of a wave-powered aquaculture farm requires numerous considerations. This report analyzes the energy demands of an integrated multi-trophic aquaculture system at various farm scales and discusses the preliminary technical, regulatory, and logistical considerations required for a co-located deployment. A pilot-scale deployment is outlined with potentially ideal characteristics, and an optimized planning and permitting approach is introduced.

16 TIDAL AND WAVE POWER↗

Co-Located Wave Energy Converter (WEC) and Aquaculture System Annotated Bibliography

This annotated bibliography includes references that could aid in the design of a co-located WEC and aquaculture system off the coast of Guam. The breadth of this work covers multiple co-location archetypes such as: 1. WEC seawater desalination system a) Nearshore and deepwater WEC deployment b) Onshore and offshore aquaculture 2. WEC powering an offshore aquaculture platform a) Nearshore or deepwater WEC deployment 3. WEC powering an onshore aquaculture system a) Nearshore WEC deployment 4. Wave powered seawater pump a) Nearshore WEC deployment b) Onshore aquaculture There are two archetypes that may be of immediate interest to the community in Guam are to service the existing Fadian Hatchery (Mangilao) and to support freshwater aquaculture activities. First, the seawater pump at the hatchery that fills the facility’s seawater storage unit is broken. A nearshore seawater pumping WEC could be a solution to this issue. In addition, due to the high frequency of typhoons/extreme conditions and the island’s bathymetry, the likelihood of community support for an offshore aquaculture platform or WEC deployed in deepwater is low. Proactive and resilient solutions not just for power, but for freshwater are of interest as well to support any freshwater aquaculture activities. Therefore, a nearshore WEC desalination system is another archetype to consider.

16 TIDAL AND WAVE POWER↗