Search NASA⌕ Search

SEARCH · Search NASA

Results for “Neutron analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Inspection of Dry Storage Casks Using PGAA and NAA Techniques

In this effort, an assessment of a chloride detection method is performed for inspecting the surfaces of dry cask storage system (DCSS) canisters, with focus on the implementation of a non-destructive nuclear analysis and methodology. Some DCSS canisters (especially those located in coastal environments) will be exposed to marine environments, which can cause atmospheric stress corrosion cracking (SCC). Chloride deposits on canister surfaces provide the corrosive environment necessary for atmospheric SCC with the residual stresses and materials properties conditions. The most susceptible regions on the canister surface are the weld areas, or where cold work has been performed, and may provide the necessary driving force for crack growth. The heat-affected zones (HAZs) near welds are also potentially susceptible to atmospheric SCC due to sensitization of the material caused by chromium depletion during the welding process. Information collected from the field and from laboratory studies has not been able to rule out the possibility of atmospheric chloride induced stress corrosion cracking (CISCC), although no occurrences of atmospheric SCC in DCSS canisters have been detected to-date. A number of researchers have demonstrated that localized corrosion can take place under such situations on materials commonly used for interim storage containers, including 304SS (Cook et al. 2010; Shirai et al. 2011) and 316SS (Tani et al. 2009). In this summary, the preliminary results of a neutron activation analysis (NAA) and prompt gamma activation analysis (PGAA) are performed using MCNP6, a highly sophisticated, multi-particle Monte Carlo simulation code (with the employment of the high performance computing system at the Idaho National Laboratory), and confirm the feasibility of using PGAA and NAA as an environmental inspection methodology for detection and monitoring of small quantities of chlorine on canister surfaces. The specific signature of gamma rays due reactions of sea salt constituents are documented and summarized in this paper. The environmental constituent for passive oxide film breaching is chlorine, which can cause pitting initiation and incubation time that may lead to cracking in stainless steel. Therefore, an assessment of chloride presence at a canister surface is essential before moving to other nondestructive analysis (NDA) methods for detection of pitting and cracking. Two nonlinear acoustic techniques will also be used in our integrated research project (IRP) research study that proves to be useful in the detection of SCC: nonlinear resonant ultrasound spectroscopy (NRUS), and time revisited elastic nonlinear diagnostic (TREND). These two techniques are complementary to marine atmospheric detection techniques. In this presentation only PGAA and NAA are described in detail. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

New capability for neutron transmission measurements at LANSCE: The DICER instrument

A new capability for neutron transmission measurements has been developed at the Los Alamos Neutron Science Center (LANSCE). The DICER (Device for Indirect Capture Experiments on Radionuclides) instrument is designed to tightly constrain neutron-capture cross sections for short-lived radionuclides that are beyond the reach of direct techniques, via measurement and analysis of neutron transmission resonances on these same radionuclides. The innovative DICER apparatus enables simultaneous sample-in and sample-out measurements, thus minimizing the amount of sample material needed and reducing the measurements time by half. A description of the current status of the new transmission station, along with a performance overview and results from known reactions, will be presented here.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Assessment of the associated particle technique with high-resolution gamma-ray spectroscopy for in-field identification of chemical warfare agents and explosives

In this work, high-resolution prompt γ-ray neutron activation analysis (PGNAA) is performed using the associated particle (AP) technique with a deuterium-tritium neutron generator and high-purity germanium detector. Although the time resolution is inferior compared to similar systems employing fast scintillation γ-ray detectors, the strong background suppression combined with the high γ-ray energy resolution provides an important boost in sensitivity to certain key elements, especially relevant to field measurements of complex chemicals encased within thick layers of metal, such as in the case of recovered chemical warfare (CW) munitions. Results for various CW and explosive simulants contained within mock munitions are presented and compared with results obtained from traditional PGNAA measurements without the aid of the AP technique. Significant improvements in identification and discrimination between certain chemicals are achieved with the high energy resolution AP technique.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Unattended Multiplicity Shift Register (UMSR)

The Unattended Multiplicity Shift Register (UMSR) is the next generation high speed attended and unattended neutron coincidence analysis data acquisition instrument. The UMSR is a specialized pulse counter used primarily to count neutron events originating in neutron detection instruments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New approach for calibration the efficiency of HpGe detectors

This work evaluates the efficiency calibrating of HpGe detector coupled with Canberra GC3018 with Genie 2000 software and Ortec GEM25-76-XLB-C with Gamma Vision software; available at Neutron activation analysis laboratory in Malaysian Nuclear Agency (NM). The efficiency calibration curve was constructed from measurement of an IAEA, standard gamma–point sources set composed by {sup 214}Am, {sup 57}Co, {sup 133}Ba, {sup 152}Eu, {sup 137}Cs and {sup 60}Co. The efficiency calibrations were performed for three different geometries: 5, 10 and 15 cm distances from the end cap detector. The polynomial parameters functions were simulated through a computer program, MATLAB in order to find an accurate fit to the experimental data points. The efficiency equation was established from the known fitted parameters which allow for the efficiency evaluation at particular energy of interest. The study shows that significant deviations in the efficiency, depending on the source-detector distance and photon energy.

42 ENGINEERING↗

New approach to calculate the true-coincidence effect of HpGe detector

The corrections for true-coincidence effects in HpGe detector are important, especially at low source-to-detector distances. This work established an approach to calculate the true-coincidence effects experimentally for HpGe detectors of type Canberra GC3018 and Ortec GEM25-76-XLB-C, which are in operation at neutron activation analysis lab in Malaysian Nuclear Agency (NM). The correction for true-coincidence effects was performed close to detector at distances 2 and 5 cm using {sup 57}Co, {sup 60}Co, {sup 133}Ba and {sup 137}Cs as standard point sources. The correction factors were ranged between 0.93-1.10 at 2 cm and 0.97-1.00 at 5 cm for Canberra HpGe detector; whereas for Ortec HpGe detector ranged between 0.92-1.13 and 0.95-100 at 2 and 5 cm respectively. The change in efficiency calibration curve of the detector at 2 and 5 cm after correction was found to be less than 1%. Moreover, the polynomial parameters functions were simulated through a computer program, MATLAB in order to find an accurate fit to the experimental data points.

07 ISOTOPE AND RADIATION SOURCES↗

Technologies for pre-screening IAEA swipe samples

During the course of International Atomic Energy Agency (IAEA) inspections, many samples are taken for the purpose of verifying the declared facility activities and identifying any possible undeclared activities. One of these sampling techniques is the environmental swipe sample. Due to the large number of samples collected, and the amount of time that is required to analyze them, prioritizing these swipes in the field or upon receipt at the Network of Analytical Laboratories (NWAL) will allow sensitive or mission-critical analyses to be performed sooner. As a result of this study, technologies were placed into one of three categories: recommended, promising, or not recommended. Both neutron activation analysis (NAA) and X-ray fluorescence (XRF) are recommended for further study and possible field deployment. These techniques performed the best in initial trials for pre-screening and prioritizing IAEA swipes. We learned that for NAA more characterization of cold elements (such as calcium and magnesium) would need to be emphasized, and for XRF it may be appropriate to move towards a benchtop XRF versus a handheld XRF due to the increased range of elements available on benchtop equipment. Promising techniques that will require additional research and development include confocal Raman microscopy, fluorescence microscopy, and infrared (IR) microscopy. These techniques showed substantive responses to uranium compounds, but expensive instrumentation upgrades (confocal Raman) or university engagement (fluorescence microscopy) may be necessary to investigate the utility of the techniques completely. Point-and-shoot (handheld) Raman and attenuated total reflectance–infrared (ATR-IR) measurements are not recommended, as they have not shown enough promise to continue investigations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Thorium, uranium and rare earth elements content in lanthanide concentrate (LC) and water leach purification (WLP) residue of Lynas advanced materials plant (LAMP)

Lynas Advanced Materials Plant (LAMP) has been licensed to produce the rare earths elements since early 2013 in Malaysia. LAMP processes lanthanide concentrate (LC) to extract rare earth elements and subsequently produce large volumes of water leach purification (WLP) residue containing naturally occurring radioactive material (NORM). This residue has been rising up the environmental issue because it was suspected to accumulate thorium with significant activity concentration and has been classified as radioactive residue. The aim of this study is to determine Th-232, U-238 and rare earth elements in lanthanide concentrate (LC) and water leach purification (WLP) residue collected from LAMP and to evaluate the potential radiological impacts of the WLP residue on the environment. Instrumental Neutron Activation Analysis and γ-spectrometry were used for determination of Th, U and rare earth elements concentrations. The results of this study found that the concentration of Th in LC was 1289.7 ± 129 ppm (5274.9 ± 527.6Bq/kg) whereas the Th and U concentrations in WLP were determined to be 1952.9±17.6 ppm (7987.4 ± 71.9 Bq/kg) and 17.2 ± 2.4 ppm respectively. The concentrations of Th and U in LC and WLP samples determined by γ- spectrometry were 1156 ppm (4728 ± 22 Bq/kg) and 18.8 ppm and 1763.2 ppm (7211.4 Bq/kg) and 29.97 ppm respectively. This study showed that thorium concentrations were higher in WLP compare to LC. This study also indicate that WLP residue has high radioactivity of {sup 232}Th compared to Malaysian soil natural background (63 - 110 Bq/kg) and come under preview of Act 304 and regulations. In LC, the Ce and Nd concentrations determined by INAA were 13.2 ± 0.6% and 4.7 ± 0.1% respectively whereas the concentrations of La, Ce, Nd and Sm in WLP were 0.36 ± 0.04%, 1.6%, 0.22% and 0.06% respectively. This result showed that some amount of rare earth had not been extracted and remained in the WLP and may be considered to be reextracted.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Elemental profiling and genome-wide association studies reveal genomic variants modulating ionomic composition in Populus trichocarpa leaves

The ionome represents elemental composition in plant tissues and can be an indicator of nutrient status as well as overall plant performance. Thus, identifying genetic determinants governing elemental uptake and storage is an important goal for breeding and engineering biomass feedstocks with improved performance. In this study, we coupled high-throughput ionome characterization of leaf tissues with high-resolution genome-wide association studies (GWAS) to uncover genetic loci that modulate ionomic composition in leaves of poplar ( Populus trichocarpa ). Significant agreement was observed across the three ionomic profiling platforms tested: inductively coupled plasma-mass spectrometry (ICP-MS), neutron activation analysis (NAA) and laser-induced breakdown spectroscopy (LIBS). Relative quantification of 20 elements using ICP-MS across a population of 584 genotypes, revealed larger variation in micro-nutrients and trace elements content than for macro-nutrients across genotypes. The GWAS performed using a set of high-density (>8.2 million) single nucleotide polymorphisms, identified over 600 loci significantly associated with variations in these mineral elements, pointing to numerous uncharacterized candidate genes. A significant enrichment for genes related to ion homeostasis and transport was observed, including several members of the cation-proton antiporters (CPA) family and MATE efflux transporters, previously reported to be critical for plant growth and fitness in other species. Our results also included a polymorphic copy of the high-affinity molybdenum transporter MOT1 found directly associated to molybdenum content. For the first time in a perennial plant, our results provide evidence of genetic control of mineral content in a model tree species.

59 BASIC BIOLOGICAL SCIENCES↗

Distribution of toenail selenium levels in young adult Caucasians and African Americans in the United States: The CARDIA Trace Element Study

Background: Data on selenium (Se) levels in American young adults, especially in African Americans, are lacking. Objective: This study presented toenail Se distributions in American young adults of both genders, including both Caucasians and African Americans; and explored potential predictors of toenail Se levels. Data and methods: Data from the Coronary Artery Risk Development in Young Adults study among 4252 American young adults, aged 20-32 in 1987 was used to examine toenail Se levels by instrumental neutron-activation analysis. The distribution of Se levels was described and multivariable linear regression was used to examine potential modifiers of toenail Se concentration within ethnicity-gender subgroups. Results: The geometric mean of toenail Se in this cohort was 0.844 {mu}g/g (95% CI, 0.840-0.849 {mu}g/g) and the median was 0.837 {mu}g/g (95% CI, 0.833-0.844 {mu}g/g). Median levels from lowest to highest quintile were 0.691, 0.774, 0.838, 0.913 and 1.037 {mu}g/g. Se levels varied geographically, and were generally in accordance with its concentrations in local soil. Males, African Americans, current smokers, heavy drinkers and less educated participants were more likely to have low Se levels. Conclusion: This study suggests that toenail Se levels vary geographically depending on soil Se concentrations. In addition to gender, ethnicity and education level, smoking status and alcohol consumption are two important indicators of Se status since they are modifiable lifestyle factors. Findings from this study might aid public health professionals in identifying people at relatively high or low Se levels, so that chronic disease prevention efforts can be directed toward these subgroups. - Research highlights: {yields} Average of toenail Se levels in this cohort was 0.844 {mu}g/g (95% CI, 0.840-0.849 {mu}g/g). {yields} Toenail Se levels vary geographically depending on soil Se concentrations. {yields} Males, African Americans and less educated participants have low Se levels. {yields} Smoking status and alcohol consumption are two important indicators of Se status.

54 ENVIRONMENTAL SCIENCES↗

Nitrate Conversion of HB-Line Reillex™ HPQ Resin

Reillex™ HPQ ion exchange resin is used by HB Line to remove plutonium from aqueous streams. Reillex™ HPQ resin currently available from Vertellus Specialties LLC is a chloride ionic form, which can cause stress corrosion cracking in stainless steels. Therefore, HB Line Engineering requested that Savannah River National Laboratory (SRNL) convert resin from chloride form to nitrate form in the Engineering Development Laboratory (EDL). To perform this task, SRNL treated two batches of resin in 2012. The first batch of resin from Reilly Industries Batch 80302MA was initially treated at SRNL in 2001 to remove chloride. This batch of resin, nominally 30 liters, has been stored wet in carboys since that time until being retreated in 2012. The second batch of resin from Batch 23408 consisted of 50 kg of new resin purchased from Vertellus Specialties in 2012. Both batches were treated in a column designed to convert resin using downflow of 1.0 M sodium nitrate solution through the resin bed followed by rinsing with deionized water. Both batches were analyzed for chloride concentration, before and after treatment, using Neutron Activation Analysis (NAA). The resin specification [Werling, 2003] states the total chlorine and chloride concentration shall be less than 250 ppm. The resin condition for measuring this concentration is not specified; however, in service the resin would always be fully wet. Measurements in SRNL showed that changing from oven dry resin to fully wet resin, with liquid in the particle interstices but no supernatant, increases the total weight by a factor of at least three. Therefore, concentration of chlorine or chloride expressed as parts per million (ppm) decreases by a factor of three. Therefore, SRNL recommends measuring chlorine concentration on an oven dry basis, then dividing by three to estimate chloride concentration in the fully wet condition. Chloride concentration in the first batch (No.80302MA) was nearly the same before the current treatment (759 ppm dry) and after treatment (745 ppm dry or ~248 ppm wet). Treatment of the second batch of resin (No.23408) was very successful. Chloride concentration decreased from 120,000 ppm dry to an average of 44 ppm dry or ~15ppm wet, which easily passes the 250 ppm wet criterion. Per guidance from HB Line Engineering, SRNL blended Batch 80302 resin with Batch P9059 resin which had been treated previously by ResinTech to remove chloride. The chloride concentrations for the two drums of Batch P9059 were 248 ppm dry (~83 ppm wet) ±22.8% and 583 ppm dry (~194 ppm wet) ± 11.8%. The blended resin was packaged in five gallon buckets.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Assessment of metabolic bone diseases by quantitative computed tomography

Advances in the radiologic sciences have permitted the development of numerous noninvasive techniques for measuring the mineral content of bone, with varying degrees of precision, accuracy, and sensitivity. The techniques of standard radiography, radiogrammetry, photodensitometry, Compton scattering, neutron activation analysis, single and dual photon absorptiometry, and quantitative computed tomography (QCT) are described and reviewed in depth. Results from previous cross-sectional and longitudinal QCT investigations are given. They then describe a current investigation in which they studied 269 subjects, including 173 normal women, 34 patients with hyperparathyroidism, 24 patients with steroid-induced osteoporosis, and 38 men with idiopathic osteoporosis. Spinal quantitative computed tomography, radiogrammetry, and single photon absorptiometry were performed, and a spinal fracture index was calculated on all patients. The authors found a disproportionate loss of spinal trabecular mineral compared to appendicular mineral in the men with idiopathic osteoporosis and the patients with steroid-induced osteoporosis. They observed roughly equivalent mineral loss in both the appendicular and axial regions in the hyperparathyroid patients. The appendicular cortical measurements correlated moderately well with each other but less well with spinal trabecular QCT. The spinal fracture index correlated well with QCT and less well with the appendicular measurements. Knowledge of appendicular cortical mineral status is important in its own right but is not a valid predictor of axial trabecular mineral status, which may be disproportionately decreased in certain diseases. Quantitative CT provides a reliable means of assessing the latter region of the skeleton, correlates well with the spinal fracture index (a semiquantitative measurement of end-organ failure), and offers the clinician a sensitive means of following the effects of therapy.

Minerals/analysis↗

Ecological risk assessment of elemental pollution in sediment from Tunku Abdul Rahman National Park, Sabah

Eleven (11) surface sediment samples were collected from Tunku Abdul Rahman National Park, Sabah. The neutron activation analysis (NAA) and inductively coupled plasma-mass spectrometry (ICP-MS) techniques were applied for the determinations metal contents and their distributions in sediment samples. The results shown that Arsenic (As) concentrations are enriched at all sampling stations except for station TAR 09, with enrichment factor (EF) values ranged from 1.1 to 7.2. The elements such as Cd, Cr, Sb and U showed enrichment at a few stations and other elements (Cr, Cu, Pb, Th, Zn) shown as background levels in all stations. Degrees of contamination in this study were calculated base on concentrations of six elements (As, Cd, Cr, Cu, Pb, and Zn). TAR 11 station can be categorized as very high degree of contamination with degree of contamination value of 43.2. TAR 07 station can be categorized as a considerable degree of contamination (contamination value of 16.9). Six stations (TAR 01, 03, 04, 05, 06, 08, 10) showed moderate degree of contamination, with contamination values ranging from 8.0 to 16.0. TAR 02 and TAR 09 stations showed low degree of contaminations (< 8.0). TAR 11 showed very high ecological risk index (R{sub I}) with RI value is 916. TAR 07 and TAR 10 showed moderate ecological risk index with R{sub I} value 263 and 213, respectively. Other stations showed low ecological risk with RI values ranging from 42.3 to 117 (< 150). Very high ecological risk index could give an adverse effect to the benthic organism. The data obtained from the enrichment factor, degree of contamination and ecological risk index provided vital information, which can be used for future comparison. Information from the present study will be useful to the relevant government agencies and authorities in preparing preventive action to control direct discharge of heavy metals from industries, agro-base activities and domestic waste to the rivers and the sea.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

New machine protection system at the Spallation Neutron Source – design process and performance analysis

A New Machine Protection System (MPS) at the Spallation Neutron Source (SNS) was developed and implemented on µTCA-based hardware platforms. The system monitors more than 2500 field inputs and shuts off the beam within 10 µs if adverse events occur. We will present system level design process of various firmware and software components as well as the system integration into EPICS environment. The performance analysis of the MPS after two SNS run cycles will also be presented.

Bobrek, Miljko [ORNL] (ORCID:0000000332763451)↗

Real-time neutron multiplicity and source localization for criticality safety during fuel debris removal

Advancing neutron detection and analysis techniques for complex radiation environments is an ongoing focus in nuclear instrumentation and monitoring. This proposal presents research and development of a generalized real-time neutron monitoring and analysis system, applicable to any detector capable of producing time-tagged neutron count data. While the work is demonstrated using the Neutron Multiplication Analysis Detector (NoMAD), a modular 15-tube helium-3 (He-3) array, due to its availability, spatial resolution, and flexible deployment, the methods developed are extensible to other systems, including organic scintillators and fast digital detectors. This research investigates two complementary analytical techniques for real-time characterization of neutron emitting sources: neutron multiplicity estimation based on the Hage-Cifarelli formalism and spatial localization using supervised machine learning applied to spatial count rate patterns. These methods are designed to operate under dynamic, evolving conditions such as fuel debris retrieval or reactor startup, where neutron-emitting material geometries may be partially unknown or changing over time. By integrating statistical neutron emission data with spatial localization, this research aims to develop and evaluate methods for real time neutron monitoring, source characterization, and material verification. Key contributions include implementation of a low-latency data pipeline for continuous neutron multiplicity analysis, development and validation of machine learning models for spatial inference, and experimental evaluation of system performance under variable measurement conditions. The outcomes are intended to support applications in nuclear safeguards, verification, emergency response, and reactor startup.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Information Content of a New Observable: The Case of the Nuclear Neutron Skin

The radius of the neutron distribution of a heavy nucleus is related to the equation of state for neutron matter that determines properties of nuclei and neutron stars. By systematically varying coupling constants characterizing the nuclear energy density functional and studying the resulting confidence ellipsoid, we quantify the relationships between the neutron skin and various properties of finite nuclei and infinite nuclear matter. According to the covariance analysis, the neutron skin is strongly correlated with the dipole polarizability and symmetry energy, and is very weakly correlated with the low-energy electric dipole strength. By adding the information on the neutron radius to the pool of observables determining the energy functional, we show how precise experimental determination of the neutron radius in ^{208}Pb would reduce theoretical uncertainties on the neutron matter equation of state.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Analysis of hafnium configuration of FLUOLE-2 program - 25409

The purpose of this paper is to present an analysis of the hafnium configuration of FLUOLE-2 program. FLUOLE-2 is a set of benchmark-type experiments dedicated to neutron attenuation analysis with the aim of improving the TRIPOLI-4{sup R} Monte Carlo code validation and industrial neutron physics scheme. The CEA developed this program, with the support of EDF, in order to be representative of 900 and 1450 MWe Pressurized Water Reactors operated in France. For that purpose, different stainless steel structures have been designed and appropriately positioned inside the EOLE facility located at Cadarache CEA center. EOLE is a pool type zero power reactor, composed of a cylindrical aluminum vessel with an over-structure of stainless steel, that is able to contain various types of core and related structures. The FLUOLE-2 core has been designed as a 29 x 29 pins square lattice of fuel rods. Different kind of dosimeters (cobalt, gold, tin, rhodium, indium, iron, nickel, titanium, aluminum, and vanadium) were irradiated inside and outside the core. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗