A poloidal high- k scattering system for NSTX-U

A previous 5-channel tangential high-k scattering system is being replaced by an 8-channel, poloidal high-k scattering system on the National Spherical Torus eXperiment Upgrade (NSTX-U) device located in Princeton, NJ, USA. The 693 GHz poloidal scattering system replaces a 280 GHz tangential scattering system to study high-k electron density fluctuations on NSTX-U, thereby considerably enhancing planned turbulence physics studies by providing a measurement of the k θ -spectrum of both electron temperature gradient (ETG) and ion temperature gradient (ITG) modes. Two approaches to generating the 693 GHz probe beam are under development: an optically-pumped far-infrared (FIR) laser that generates ~50 mW, and a compact gyrotron that can potentially generate in excess of 5 W. Large aperture optics collect radiation scattered from density fluctuations in the plasma core at 8 simultaneous scattering angles ranging from 2 to 15° corresponding to poloidal wavenumbers that extend to >40 cm -1 . Finally, steerable launch optics coupled with receiver optics mounted on a 5-axis receiver carriage allow the scattering volume to be placed radially from r/a = 0.3 out to the pedestal region (r/a ~ 0.99) and translated horizontally as needed to satisfy wavenumber matching.

47 OTHER INSTRUMENTATION↗

Matter-wave interference of a native polypeptide

The de Broglie wave nature of matter is a paradigmatic example of quantum physics and it has been exploited in precision measurements of forces and fundamental constants. However, matter-wave interferometry has remained an outstanding challenge for natural polypeptides, building blocks of life, which are fragile and difficult to handle. Here, we demonstrate the wave nature of gramicidin, a natural antibiotic composed of 15 amino acids. Its center of mass is delocalized over more than 20 times the molecular size in our timedomain Talbot-Lau interferometer. We compare the observed interference fringes with a model that includes both a rigorous treatment of the peptide’s quantum wave nature as well as a quantum chemical assessment of its optical properties to distinguish our result from classical predictions. The realization of quantum optics with this prototypical biomolecule paves the way for quantum-assisted measurements on a large class of biologically relevant molecules.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Stochastic frequency fluctuation super-resolution imaging

The inherent non-linearity of intensity correlation functions can be used to spatially distinguish identical emitters beyond the diffraction limit, as achieved, for example, in super-resolution optical fluctuation imaging (SOFI). Here, we propose a complementary concept based on spectral correlation functions, termed spectral fluctuation super-resolution (SFSR) imaging. Through theoretical and computational analysis, we show that spatially resolving time-frequency correlation functions in the image plane can improve the imaging resolution by a factor of $\sqrt2$ in most cases and up to twofold for strictly two emitters. This improvement is achieved by quantifying the degree of correlation in spectral fluctuations across the spatial domain. Experimentally, SFSR can be implemented using a combination of interferometry and photon-correlation measurements. The method works for non-blinking emitters and stochastic spectral fluctuations with arbitrary temporal statistics. This suggests its utility in super-resolution microscopy of quantum emitters at low temperatures, where spectral diffusion is often more pronounced than emitter blinking.

47 OTHER INSTRUMENTATION↗

Advanced Photon Acceleration Schemes for Tunable XUV/Soft X-Ray Sources

We report on the advances made under the purview of DOE award number DE-SC0019135 that was active during the period: 09/01/2018–08/31/2021. The grant investigated the application of a “flying focus” to the problem of photon acceleration—in which a dynamic refractive index gradient is used to continuously upshift a probe beam’s frequency. Codes were written to describe the creation of ionization waves of arbitrary velocity (IWAVs) for use as a photon-accelerating medium, as well as the behavior of a witness pulse residing in said medium. Experiments first verified the spatiotemporal control over laser intensity provided by a chromatic flying focus, then used that ability to produce small-diameter IWAVs in the far-field with the expected dynamics, and finally demonstrated even further flexibility by producing large-diameter IWAVs in the laser quasi-far-field that maintained the beneficial dynamics. Multiple innovative diagnostics—spectrally resolved Schlieren and spectrally resolved interferometry—were pioneered in order to diagnose the IWAVs. For IWAV production in the laboratory, however, beam quality was identified as a key limitation in the quasi-far-field. Since the original chromatic flying focus was found to result in relatively long (ps duration) intensity peaks, which could limit some applications including photon acceleration, additional techniques were invented to provide similar spatiotemporal control while also retaining ultrashort intensity peaks. While simulations have identified several interesting regimes for photon acceleration—first predicting the upshift of a counterpropagating witness pulse from the optical to the extreme ultraviolet in less than 1 cm, and later obtaining similar shifts in less than 100 μm in a simpler self-seeded configuration—experimental demonstration is left for future work.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

EVN observations of HESS J1943+213: evidence for an extreme TeV BL Lac object

We report on the 1.6 GHz (18 cm) very long baseline interferometry (VLBI) observations of the unresolved, steady TeV source HESS J1943+213 located in the Galactic plane, performed with the European VLBI Network (EVN) in 2014. Our new observations with a nearly full EVN array provide the deepest image of HESS J1943+213 at the highest resolution ever achieved, enabling us to resolve the long-standing issues of the source identification. The milliarcsecond-scale structure of HESS J1943+213 has a clear asymmetric morphology consisting of a compact core and a diffuse jet-like tail. This is broadly consistent with the previous e-EVN observations of the source performed in 2011 and re-analyzed in this work. The core component is characterized by the brightness temperature of ≳1.8×10{sup 9} K, which is typical for low-luminosity blazars in general. Overall, the radio properties of HESS J1943+213 are consistent with the source classification as an “extreme high-frequency-peaked BL Lac object.” Remarkably, we note that because HESS J1943+213 does not reveal any optical or infrared signatures of the active galactic nucleus activity, it would never be recognized and identified as a BL Lac object if not for its location close to the Galactic plane where the High Energy Stereoscopic System surveyed for and the follow-up dedicated X-ray and radio studies triggered by the source detection in the TeV range. Our results suggest, therefore, a presence of an unrecognized, possibly very numerous population of particularly extreme HBLs and simultaneously demonstrate that the low-frequency VLBI observations with high angular resolution are indispensable for a proper identification of such objects.

79 ASTRONOMY AND ASTROPHYSICS↗

Photon self-induced spin-to-orbital conversion in a terbium-gallium-garnet crystal at high laser power

In this paper, we present experimental evidence of a third-order nonlinear optical process, self-induced spin-to-orbital conversion (SISTOC) of the photon angular momentum. This effect is the physical mechanism at the origin of the depolarization of very intense laser beams propagating in isotropic materials. The SISTOC process, like self-focusing, is triggered by laser heating leading to a radial temperature gradient in the medium. In this work we tested the occurrence of SISTOC in a terbium-gallium-garnet rod for an impinging laser power of about 100 W. To study the SISTOC process we used different techniques: polarization analysis, interferometry, and tomography of the photon orbital angular momentum. Our results confirm, in particular, that the apparent depolarization of the beam is due to the occurrence of maximal entanglement between the spin and orbital angular momentum of the photons undergoing the SISTOC process. This explanation of the true nature of the depolarization mechanism could be of some help in finding novel methods to reduce or to compensate for this usually unwanted depolarization effect in all cases where very high laser power and good beam quality are required.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Time-Resolved Hanbury Brown–Twiss Interferometry of On-Chip Biphoton Frequency Combs Using Vernier Phase Modulation

Biphoton frequency combs (BFCs) are promising quantum sources for large-scale and high-dimensional quantum information and networking systems. In this context, the spectral purity of individual frequency bins will be critical for realizing quantum networking protocols like teleportation and entanglement swapping. Measurement of the temporal autocorrelation function of the unheralded signal or idler photons comprising the BFC is a key tool for characterizing their spectral purity and in turn verifying the utility of the biphoton state for networking protocols. Yet the experimentally obtainable precision for measuring BFC correlation functions is often severely limited by detector jitter. The fine temporal features in the correlation function—not only of practical value in quantum information, but also of fundamental interest in the study of quantum optics—are lost as a result. We propose a scheme to circumvent this challenge through electro-optic phase modulation, experimentally demonstrating time-resolved Hanbury Brown–Twiss characterization of BFCs generated from an integrated 40.5-GHz Si 3 N 4 microring, up to a 3×3-dimensional two-qutrit Hilbert space. Through slight detuning of the electro-optic drive frequency from the comb’s free spectral range, our approach leverages Vernier principles to magnify temporal features, which would otherwise be averaged out by detector jitter. We demonstrate our approach under both continuous-wave and pulsed-pumping regimes, finding excellent agreement with theory. In conclusion, our method reveals not only the collective statistics of the contributing frequency bins but also their temporal shapes—features lost in standard fully integrated autocorrelation measurements.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

HIGH-SENSITIVITY ARRAY OBSERVATIONS OF THE z = 1.87 SUBMILLIMETER GALAXY GOODS 850-3

We present sensitive phase-referenced Very Long Baseline Interferometry (VLBI) results on the radio continuum emission from the z = 1.87 luminous submillimeter galaxy (SMG) GOODS 850-3. The observations were carried out at 1.4 GHz using the High-Sensitivity Array (HSA). Our sensitive tapered VLBI image of GOODS 850-3 at 0.''47 x 0.''34 (3.9 x 2.9 kpc) resolution shows a marginally resolved continuum structure with a peak flux density of 148 {+-} 38 {mu}Jy beam{sup -1}, and a total flux density of 168 {+-} 73 {mu}Jy, consistent with previous Very Large Array and MERLIN measurements. The deconvolved size of the source is 0.''27({+-}0.''12) x <0.''23, or 2.3({+-}1.0) x <1.9 kpc, and the derived intrinsic brightness temperature is >(5 {+-} 2) x 10{sup 3} K. The radio continuum position of this galaxy coincides with a bright and extended near-infrared source that nearly disappears in the deep Hubble Space Telescope optical image, indicating a dusty source of nearly 9 kpc in diameter. No continuum emission is detected at the full VLBI resolution (13.2 x 7.2 mas, 111 x 61 pc), with a 4{sigma} point source upper limit of 26 {mu}Jy beam{sup -1}, or an upper limit to the intrinsic brightness temperature of 4.7 x 10{sup 5} K. The extent of the observed continuum source at 1.4 GHz and the derived brightness temperature limits are consistent with the radio emission (and thus presumably the far-infrared emission) being powered by a major starburst in GOODS 850-3, with a star formation rate of {approx}2500 M {sub sun} yr{sup -1}. Moreover, the absence of any continuum emission at the full resolution of the VLBI observations indicates the lack of a compact radio-loud active galactic nucleus in this z = 1.87 SMG.

79 ASTRONOMY AND ASTROPHYSICS↗

Quantum interferometry and pathway selectivity in the nonlinear response of photosynthetic excitons

We propose a time–frequency resolved spectroscopic technique which employs nonlinear interferometers to study exciton–exciton scattering in molecular aggregates. A higher degree of control over the contributing Liouville pathways is obtained as compared to classical light. We show how the nonlinear response can be isolated from the orders-of-magnitude stronger linear background by either phase matching or polarization filtering. Both arise due to averaging the signal over a large number of noninteracting, randomly oriented molecules. We apply our technique to the Frenkel exciton model which excludes charge separation for the photosystem II reaction center. We show how the sum of the entangled photon frequencies can be used to select two-exciton resonances, while their delay times reveal the single-exciton levels involved in the optical process.

Science & Technology - Other Topics↗

Single-Shot Diagnostics of Microbunched Electrons in Laser-Driven Plasma Accelerators and Free-Electron Lasers

aThe need for single-shot diagnostics of the periodic longitudinal density modulation of relativistic electrons at the resonant wavelength (microbunching) in a free-electron laser (FEL) or at broadband visible wavelengths as in a laser-driven plasma accelerator (LPA) has been reaffirmed. In the self-amplified spontaneous emission (SASE) FEL case, statistical fluctuations in the microbunching occur in the startup- from-noise process. In the LPA, the plasma itself is chaotic and varies shot to shot. Fortunately, we have shown that coherent optical transition radiation (COTR) techniques, can assess beam size, divergence, spectral evolution, and z-dependent gain (100,000) of microbunched electrons in a past SASE FEL experiment at 530 nm*. Recently, the application to LPAs has been demonstrated with single-shot near-field (NF) and far-field (FF) COTR imaging done at the exit of an LPA for the first time**. In this case few-micron beam sizes and extensive fringes due to su b-mrad divergences were measured based on point-spread-function effects and an analytical model for COTR interferometry (COTRI), respectively. A new COTR-based diagnostics application to pre-bunched electron beams formed by co-propagating a laser pulse and the electron pulse in a short undulator (modulator) is also described.

43 PARTICLE ACCELERATORS↗

SUPERNOVA 1986J VERY LONG BASELINE INTERFEROMETRY. II. THE EVOLUTION OF THE SHELL AND THE CENTRAL SOURCE

We present new Very Long Baseline Interferometry (VLBI) images of supernova (SN) 1986J, taken at 5, 8.4, and 22 GHz between t = 22 and 25 yr after the explosion. The shell expands {proportional_to}{proportional_to}t {sup 0.69+}-{sup 0.03}. We estimate the progenitor's mass-loss rate at (4-10) x 10{sup -5} M{sub sun} yr{sup -1} (for v{sub w} = 10 km s{sup -1}). Two bright spots are seen in the images. The first, in the northeast, is now fading. The second, very near the center of the projected shell and unique to SN 1986J, is still brightening relative to the shell, and now dominates the VLBI images. It is marginally resolved at 22 GHz (diameter {approx}0.3 mas; {approx}5 x 10{sup 16} cm at 10 Mpc). The integrated VLA spectrum of SN 1986J shows an inversion point and a high-frequency turnover, both progressing downward in frequency and due to the central bright spot. The optically thin spectral index of the central bright spot is indistinguishable from that of the shell. The small proper motion of 1500 +- 1500 km s{sup -1} of the central bright spot is consistent with our previous interpretation of it as being associated with the expected black-hole or neutron-star remnant. Now, an alternate scenario seems also plausible, where the central bright spot, like the northeast one, results when the shock front impacts on a condensation within the circumstellar medium (CSM). The condensation would have to be so dense as to be opaque at cm wavelengths ({approx}10{sup 3}x denser than the average corresponding CSM) and fortuitously close to the center of the projected shell. We include a movie of the evolution of SN 1986J at 5 GHz from t = 0 to 25 yr.

79 ASTRONOMY AND ASTROPHYSICS↗

Melt dynamics of aluminum irradiated with ultrafast laser radiation at large intensities

Ablation of bulk aluminum has been investigated in situ using ultrafast laser radiation produced by chirped-pulse amplification technique (t{sub p}=80 fs, lambda=800 nm). Melt dynamics and the contribution of the amplified spontaneous emission (ASE) to the ablation have been studied experimentally and numerically for laser fluences well above ablation threshold (F < or approx. 10{sup 3}xF{sub thr}). Using transient quantitative phase microscopy (TQPm), dimensions and volume of ejected vapor, melt droplets, and liquid jets has been investigated. Computational analysis of the optical phase images has been used to determine the total volume of ejected material. A series of time-resolved phase images of vaporized material and/or melt, which are induced by n=1.8 pulses on an aluminum target, are obtained by means of TQPm up to temporal delay tau=1.65 mus after irradiation. Increase in material ejection rate is observed at delays tauapprox =300 ns and tauapprox =1.1 mus after the incident pulse. For large irradiation intensities a considerable contribution of ASE to ablation dynamics has been detected. Ex situ measurements of the ablated material by means of white-light interferometry and scanning electron microscopy provides corresponding factual removed volumes and highlight the pulse-to-pulse morphology changes.

36 MATERIALS SCIENCE↗

Sub-melt nanosecond pulsed-laser induced densification and strain-field relaxation in single-crystal diamond

Dislocations and polishing-induced defect networks in synthetic diamond introduce local strain fields and broaden Raman features, limiting performance in optical, thermal, and electronic applications. Laser annealing is emerging as a promising approach to repair surface and near-surface defects in diamond without entering the melt regime, yet surface densification, defect-state modification, and associated structural changes have not been well quantified. In this work, we show that sub-melt nanosecond pulsed-laser annealing (PLA) induces near-surface densification and defect-mediated strain relaxation in single-crystal Chemical Vapor Deposition (CVD) diamond. Single- and two-pulse PLA were applied, and structural evolution was quantified using co-registered ISO 25,178 white-light interferometry, depth-resolved Raman spectroscopy, and cross-sectional STEM with geometric phase analysis (GPA). Across a 5 × 6 grid (n = 30), responsive regions exhibit large reductions in local slope (Sdq 45–65%), developed area (Sdr 60–90%), height spread (Sp, Sz 30–65%), void volume (Vv 57–60%), and roughness amplitude (Sa, Sq 48–57%), consistent with densification of ∼4–6.5 nm. Raman profiling shows narrowing of the diamond line and improved spectral uniformity to depths of ∼2–3 μm. Given that the Raman probing depth significantly exceeds the densified layer thickness, this response is interpreted as consistent with long-range strain-field redistribution originating from the near-surface region. STEM-GPA strain maps further support this interpretation, showing smoother strain fields, suppressed hotspots, and redistribution of localized strain concentrations following PLA. These results are consistent with defect-mediated strain relaxation and densification-driven modification of the near-surface energy state. The approach provides a scalable pathway for improving near-surface structural quality in diamond relevant to electronic, photonic, and quantum applications.

Areal surface metrology (ISO 25,178)↗

Benchmarking of hydrodynamic plasma waveguides for multi-GeV laser-driven electron acceleration

Hydrodynamic plasma waveguides initiated by optical field ionization have recently become a key component of multi-GeV laser wakefield accelerators. Here, we present the most complete and accurate experimental and simulation-based characterization to date, applicable to current multi-GeV experiments and future 100 GeV-scale laser plasma accelerators. Crucial to the simulations is the correct modeling of intense Bessel beam interaction with meter-scale gas targets, the results of which are used as initial conditions for hydrodynamic simulations. The simulations are in good agreement with our experiments measuring evolving plasma and neutral hydrogen density profiles using two-color short pulse interferometry, enabling realistic determination of the guided mode structure for application to laser-driven plasma accelerator design. Published by the American Physical Society 2024

Physics↗

Extreme temperature robust optical sensor designs and fault-tolerant signal processing

Silicon Carbide (SiC) probe designs for extreme temperature and pressure sensing uses a single crystal SiC optical chip encased in a sintered SiC material probe. The SiC chip may be protected for high temperature only use or exposed for both temperature and pressure sensing. Hybrid signal processing techniques allow fault-tolerant extreme temperature sensing. Wavelength peak-to-peak (or null-to-null) collective spectrum spread measurement to detect wavelength peak/null shift measurement forms a coarse-fine temperature measurement using broadband spectrum monitoring. The SiC probe frontend acts as a stable emissivity Black-body radiator and monitoring the shift in radiation spectrum enables a pyrometer. This application combines all-SiC pyrometry with thick SiC etalon laser interferometry within a free-spectral range to form a coarse-fine temperature measurement sensor. RF notch filtering techniques improve the sensitivity of the temperature measurement where fine spectral shift or spectrum measurements are needed to deduce temperature.

47 OTHER INSTRUMENTATION↗

Piezoelectric and optical setup to measure an electrical field: Application to the longitudinal near-field generated by a tapered coax

We propose a new setup to measure an electrical field in one direction. This setup is made of a piezoelectric sintered lead zinconate titanate film and an optical interferometric probe. We used this setup to investigate how the shape of the extremity of a coaxial cable influences the longitudinal electrical near-field generated by it. For this application, we designed our setup to have a spatial resolution of 100 {mu}m in the direction of the electrical field. Simulations and experiments are presented.

36 MATERIALS SCIENCE↗

Laser-interferometric detectors for gravitational wave backgrounds at 100 MHz: Detector design and sensitivity

Recently, observational searches for gravitational wave background (GWB) have been developed and given direct and indirect constraints on the energy density of GWB in a broad range of frequencies. These constraints have already rejected some theoretical models of large GWB spectra. However, at 100 MHz, there is no strict upper limit from direct observation, though the indirect limit by {sup 2}He abundance due to big-bang nucleosynthesis exists. In this paper, we propose an experiment with laser interferometers searching GWB at 100 MHz. We considered three detector designs and evaluated the GW response functions of a single detector. As a result, we found that, at 100 MHz, the most sensitive detector is the design, a so-called synchronous recycling interferometer, which has better sensitivity than an ordinary Fabry-Perot Michelson interferometer by a factor of 3.3 at 100 MHz. When we select the arm length of 0.75 m and realistic optical parameters, the best sensitivity achievable is h{approx_equal}7.8x10{sup -21} Hz{sup -1/2} at 100 MHz with bandwidth {approx}2 kHz.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗