Search NASA⌕ Search

SEARCH · Search NASA

Results for “Tabulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

TU-D-201-06: HDR Plan Prechecks Using Eclipse Scripting API

Purpose: Automate brachytherapy treatment plan quality check using Eclipse v13.6 scripting API based on pre-configured rules to minimize human error and maximize efficiency. Methods: The HDR Precheck system is developed based on a rules-driven approach using Eclipse scripting API. This system checks for critical plan parameters like channel length, first source position, source step size and channel mapping. The planned treatment time is verified independently based on analytical methods. For interstitial or SAVI APBI treatment plans, a Patterson-Parker system calculation is performed to verify the planned treatment time. For endobronchial treatments, an analytical formula from TG-59 is used. Acceptable tolerances were defined based on clinical experiences in our department. The system was designed to show PASS/FAIL status levels. Additional information, if necessary, is indicated appropriately in a separate comments field in the user interface. Results: The HDR Precheck system has been developed and tested to verify the treatment plan parameters that are routinely checked by the clinical physicist. The report also serves as a reminder or checklist for the planner to perform any additional critical checks such as applicator digitization or scenarios where the channel mapping was intentionally changed. It is expected to reduce the current manual plan check time from 15 minutes to <1 minute. Conclusion: Automating brachytherapy plan prechecks significantly reduces treatment plan precheck time and reduces human errors. When fully developed, this system will be able to perform TG-43 based second check of the treatment planning system’s dose calculation using random points in the target and critical structures. A histogram will be generated along with tabulated mean and standard deviation values for each structure. A knowledge database will also be developed for Brachyvision plans which will then be used for knowledge-based plan quality checks to further reduce treatment planning errors and increase confidence in the planned treatment.

61 RADIATION PROTECTION AND DOSIMETRY↗

WE-AB-207B-12: Prospective Study of the Relationship Between Dose-Volume Clinical Toxicity and Patient Reported Outcomes in Lung Cancer Patients Treated with SBRT

Purpose: To determine in a prospective study, the correlation between radiation dose/volume, clinical toxicities and patient-reported, quality of life (QOL) resulting from lung SBRT. Methods: For 106 non-small cell lung cancer (NSCLC) patients receiving SBRT (12 Gy × 4), symptoms including cough, dyspnea, fatigue and pneumonitis were measured at baseline (before treatment), after treatment and 3, 6, and 12 months post-treatment. Toxicity was graded from zero to five. Dosimetric parameters such as the MLD, D10%, D20%, and lung subvolumes (V10 and V20) were obtained from the treatment plan. Dosimetric parameters and number of patients demonstrating toxicity ≥ grade 2 were tabulated. Linear regression analysis was used to calculate correlations between MLD and D10, D20, V10 and V20. Results: The percentages of patients with > grade 2 pneumonitis, fatigue, cough, and dyspnea over 3 to 12 months increased from 0.0% to 3.5%, 3.2% to 10.5%, 4.3% to 8.3%, and 10.8% to 18.8%, respectively. Computed dose indices D10%, D20% were 7.9±4.8 Gy and 3.0±2.3 Gy, respectively. MLD ranged from 0.34 Gy up to 9.9 Gy with overall average 3.0±1.7 Gy. The averages of the subvolumes V10 and V20 were respectively 8.9±5.3% and 3.0±2.4%. The linear regression analysis showed that V10 and D10 demonstrated the strongest correlation to MLD; R2= 0.92 and 0.87, respectively. V20, and D20 were also strongly correlated with MLD; R2 = 0.81 and 0.84 respectively. A correlation was also found to exist between MLD > 2 Gy and ≥ grade 2 cough and dyspnea. Subvolume values for 2Gy MLD were 5.3% for V10 and 2% for V20. Conclusion: Dosimetric indices: MLD ≥ 2Gy, D10 ≥ 5Gy and V10 ≥ 5% of the total lung volume were predictive of > grade 2 cough and dyspnea QOL data. The QOL results are a novel component of this work. acknowledgement of the Varian grant support.

60 APPLIED LIFE SCIENCES↗

Poster - 15: Air kerma rate measurements using a cylindrical free-air ionization chamber on the 05B1-1 beamline at the Canadian Light Source

Purpose: The BioMedical Imaging and Therapy (BMIT) beamlines at the Canadian Light Source offer the opportunity for investigating novel imaging and therapy applications of synchrotron radiation. A necessary component in advancing this research, and in progressing toward clinical applications, is the availability of accurate dosimetry that is traceable to a standards institution. However, dosimetry in this setting is challenging. These beams are typically small, non-uniform, and highly intense. This work describes air kerma rate measurements on a BMIT beamline using a free-air ionization chamber (FAC). Methods: The measurements were taken at the 05B1-1 beamline (∼8 – 100 keV) for several beam qualities with mean energies between 20.0 and 84.0 keV. The Victoreen Model 480 cylindrical FAC, with a specially fabricated 0.52 mm diameter aperture, was used to measure air kerma rates. The required correction factors were determined using a variety of methods: tabulated data, measurements, theoretical calculations and Monte Carlo simulations (EGSnrc user code egs-fac). Results: The experimental air kerma rates measured between 0.270 ± 13.6% and 312 ± 2.7% Gy/min. At lower energies (low filtration), the most impactful correction factors were those for ion recombination and for x-ray attenuation. Conclusions: These measurements marked the first absolute dosimetry performed at the BMIT beamlines. The experimental and Monte Carlo methods developed will allow air kerma rates to be measured under other experimental conditions, provide a benchmark to which other dosimeters will be compared, and provide a reference for imaging and therapy research programs on this beamline.

60 APPLIED LIFE SCIENCES↗

Spectra for the reemission of attosecond and shorter electromagnetic pulses by multielectron atoms

Based on the analytical solution of the Schrödinger equation, we have considered the reemission of attosecond and shorter electromagnetic pulses by multielectron atoms in the sudden perturbation approximation. We have developed a technique of calculating the spectra for the reemission of attosecond and shorter electromagnetic pulses by neutral multielectron atoms with nuclear charges from 1 to 92. The results are presented in the form of analytical formulas dependent on several coefficients and screening parameters tabulated for all of the atoms whose electron densities are described by the well-known Dirac–Hartree–Fock–Slater model. As examples we have calculated the spectra for the reemission by lithium, carbon, calcium, and iron atoms for two types of incident pulse: Gaussian and “sombrero.”.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dispersion of Lifetimes of Excited States of Single Molecules in Organic Matrices at Ultralow Temperatures

Fluorescence excitation spectra of single terrylene molecules in transparent naphthalene and polyethylene matrices at ultralow (30–100 mK) temperatures have been studied under the conditions where the widths of zero-phonon spectral lines are determined only by the lifetime T{sub 1} of the excited electronic state. The experimentally observed dispersion of T{sub 1} values for identical molecules is attributed to local field effects, which are responsible for the dependence of T{sub 1} on the effective value of refractive index n of the matrix, which is characteristic of the localization region of each molecule. It has been shown that the dependence T{sub 1}(n) for ensembles of point emitters in organic matrices is satisfactorily explained within the model of a “virtual cavity” around the emitter inside a continuous medium, as well as within the developed quantum kinetic approach including various contributions of the local environment to the lifetime T{sub 1}. The recalculation of average T{sub 1} values to the corresponding n values with the use of the expressions obtained for T{sub 1}(n) has shown that the difference of the calculated refractive indices of naphthalene and polyethylene from the well-known tabulated n values is less than 1%.

74 ATOMIC AND MOLECULAR PHYSICS↗

Energy weighting for the upgrade of the CMS HCAL

In these simulation studies an energy weighting method is applied to the signals of the CMS hadronic calorimeter readout with a longitudinal segmentation for a possible future upgrade. Tabulated weighting factors are used to compensate for the different response of hadronic and electromagnetic energy depositions of simulated pion showers in the hadronic calorimeter. The weighting improves the relative energy resolution: ( Greek-Small-Letter-Sigma {sub E}/E){sup 2} = [((92.2 {+-} 0.6)%/{radical}E){sup 2} + ((6.5 {+-} 01)%{sup 2}] (before weighting), (( Greek-Small-Letter-Sigma {sub E,weight}/E){sup 2} = [((85.4 {+-} 0.5)%/{radical}E){sup 2} + ((4.4 {+-} 0.1)%{sup 2}] (after weighting), where E in the square root has units of GeV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of the production cross section for charmed baryons in proton–nucleus interactions at 70 GeV

The results of an analysis of data from the SERP-E-184 experiment devoted to studying mechanisms of the production of charmed particles in proton–nucleus interactions at 70 GeV and their decays are presented. The data in question were obtained upon irradiating the SVD-2 active target consisting of carbon, silicon, and lead plates with a beam of 70-GeV protons. A detailed simulation on the basis of the FRITIOF7.02 and GEANT3.21 code packages made it possible to optimize event-selection criteria and to calculate the detection efficiency for Λ{sub c}{sup +} baryons. After selecting a signal from the threebody decay of a Λ{sub c}{sup +} baryon, the inclusive cross section for its production at near-threshold energies, its lifetime, and the parameter of the A dependence of the cross section were found. The Λ{sub c}{sup +} -baryon yields are tabulated along with data from other experiments and theoretical predictions.

74 ATOMIC AND MOLECULAR PHYSICS↗

Recirculating Electron Accelerators with Noncircular Electron Orbits as Radiation Sources for Applications (a Review)

State-of-the-art compact recirculating electron accelerators operating at intermediate energies (tens of MeV) are reviewed. The acceleration schemes implemented in the rhodotron, ridgetron, fantron, and cylindertron machines are discussed. Major accelerator components such as the electron guns, accelerating cavities, and bending magnets are described. The parameters of currently operating recirculating accelerators are tabulated, and applications of these accelerators in different processes of irradiation are exemplified.

43 PARTICLE ACCELERATORS↗

A Fast Butterfly-Compressed Hadamard–Babich Integrator for High-Frequency Helmholtz Equations in Inhomogeneous Media with Arbitrary Sources

Here we present a butterfly-compressed representation of the Hadamard-Babich (HB) ansatz for the Green's function of the high-frequency Helmholtz equation in smooth inhomogeneous media. For a computational domain discretized with Nv discretization cells, the proposed algorithm first solves and tabulates the phase and HB coefficients via eikonal and transport equations with observation points and point sources located at the Chebyshev nodes using a set of much coarser computation grids, and then butterfly compresses the resulting HB interactions from all Nv cell centers to each other. The overall CPU time and memory requirement scale as O(Nv log2 Nv) for any bounded two-dimensional (2D) domains with arbitrary excitation sources. A direct extension of this scheme to bounded 3D domains yields an O(Nv4/3) CPU complexity, which can be further reduced to quasi-linear complexities with proposed remedies. The scheme can also efficiently handle scattering problems involving inclusions in inhomogeneous media. Although the current construction of our HB integrator does not accommodate caustics, the resulting HB integrator itself can be applied to certain sources, such as concave-shaped sources, to produce caustic effects. Compared to finite-difference frequency domain methods, the proposed HB integrator is free of numerical dispersion and requires fewer discretization points per wavelength. As a result, it can solve wave propagation problems well beyond the capability of existing solvers. Remarkably, the proposed scheme can accurately model wave propagation in 2D domains with 640 wavelengths per direction and in 3D domains with 54 wavelengths per direction on a state-of-the-art supercomputer at Lawrence Berkeley National Laboratory.

Hadamard--Babich ansatz↗

Meson Photo-Production in GEANT4 for $E_\gamma = 0.225$ E γ = 0 . 225 -3.0 GeV using the $\gamma + p \rightarrow p + \pi^{0}$ reaction

The study of nuclear resonances in the intermediate energy regime requires accurate modeling of the experimental physics background. The cross sections in the GEANT4 toolkit do not adequately treat meson photo-production. The purpose of this study is to compare experimental data and theoretical models implemented in version 9.6.p02 of the GEANT4 Monte Carlo simulation toolkit for the exclusive and differential cross sections of $\pi^0$ photo-production. Two models were studied: the Chiral Invariant Phase Space (CHIPS) and Bertini Cascade (BERT). The cross section data from the models were compared to the experimental data from the CEBAF Large Acceptance Spectrometer (CLAS) of Jefferson Lab and the phenomenological Scattering Analysis Interactive Dial-in (SAID) model. Relativistic Breit-Wigner fits were used to compare the $\Delta(1232)$, N*(1520), N*(1650) and N*(1875) resonances from SAID, CLAS and CHIPS, giving agreements to within 3% for the mass of each resonance. The limited tabulated data set of BERT does not allow for an accurate description of the energy distribution, even following its improvement in version 10p02. The angular distributions of the cross sections show significant differences between CHIPS and both CLAS and SAID data, the latter being the most accurate model to describe the $\gamma p\rightarrow p\pi ^0$ exclusive cross section. Finally, the physics in CHIPS appears to be correct but it needs further development for the individual resonances contributions that could be useful since it is also the only model able to treat electromagnetically induced meson production for $A>1$.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Particle spectra and HBT radii for simulated central nuclear collisions of C + C, Al + Al, Cu + Cu, Au + Au, and Pb + Pb from $\sqrt{s}$ = 62.4-2760 GeV

Here, we study the temperature profile, pion spectra, and HBT radii in central, symmetric, and boost-invariant nuclear collisions, using a super hybrid model for heavy-ion collisions (SONIC), combining pre-equilibrium flow with viscous hydrodynamics and late-stage hadronic rescatterings. In particular, we simulate Pb + Pb collisions at $\sqrt{s}$ = 2.76 TeV, Au + Au, Cu + Cu, Al + Al, and C + C collisions at $\sqrt{s}$ = 200 GeV, and Au + Au and Cu + Cu collisions at $\sqrt{s}$ = 62.4 GeV. We find that SONIC provides a good match to the pion spectra and HBT radii for all collision systems and energies, confirming earlier work that a combination of pre-equilibrium flow, viscosity, and QCD equation of state can resolve the so-called HBT puzzle. For reference, we also show p + p collisions at $\sqrt{s}$ = 7 TeV. We make tabulated data for the 2 + 1 dimensional temperature evolution of all systems publicly available for the use in future jet energy loss or similar studies.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Free energies for acid attack reactions of lithium cobaltate.

The attack of lithium-ion battery cathodes by stray aqueous HF, with resultant dissolution, protonation, and possibly other unintended reactions, can be a significant source of capacity fade. We explore the calculation of reaction free energies of lithium cobaltate in acid by a 'hybrid' method, in which solid-phase free energies are calculated from first principles at the generalized gradient approximation + intrasite coulomb interaction (GGA+U) level and tabulated values of ionization potentials and hydration energies are employed for the aqueous species. Analysis of the dissolution of the binary oxides Li{sub 2}O and CoO suggests that the atomic energies for Co and Li should be shifted from values calculated by first principles to yield accurate reaction free energies within the hybrid method. With the shifted atomic energies, the hybrid method was applied to analyze proton-promoted dissolution and protonation reactions of LiCoO{sub 2} in aqueous acid. Reaction free energies for the dissolution reaction, the reaction to form Co{sub 3}O{sub 4} spinel, and the proton-for-lithium exchange reaction are obtained and compared to empirical values. An extension of the present treatment to consider partial reactions is proposed, with a view to investigating interfacial and environmental effects on the dissolution reaction.

25 ENERGY STORAGE↗

Typical values of Rietveld instrument profile coefficients

GSAS instrument parameters are tabulated for a variety of laboratory and synchrotron diffractometers to give users an idea of the typical ranges of profile parameters when they generate their own instrument parameter files. For modern high-resolution laboratory diffractometers, the parameters fall in the ranges 0 < U < 3, V = 0, 0 < W < 4, 1 < X < 3, 0 < Y < 3, 1 < asym < 3, and 0 < S/L < 0.03. For synchrotron diffractometers, the parameters fall in the ranges 0 < U < 1.2, -1 < V < 0, 0 < W < 1, 0 < X < 1, 0 < Y < 1, 0 < asym < 0.5, 0 < S/L < 0.001, and 0 < H/L < 0.007. FULLPROF equivalents are also reported. The factors which are convoluted together to generate the instrument profile are described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Doping of TiO 2 Polymorphs for Altered Optical and Photocatalytic Properties

This paper reviews recent investigations of the influence of dopants on the optical properties of TiO 2 polymorphs. The common undoped polymorphs of TiO 2 are discussed and compared. The results of recent doping efforts are tabulated, and discussed in the context of doping by elements of the same chemical group. Dopant effects on the band gap and photocatalytic activity are interpreted with reference to a simple qualitative picture of the TiO 2 electronic structure, which is supported with first‐principles calculations.

Nie, Xiliang↗

Stride Search v. 1.0

Stride Search provides a flexible tool for detecting storms or other extreme climate events in high-resolution climate data sets saved on uniform latitude-longitude grids in standard NetCDF format. Users provide the software a quantitative description of a meteorological event they are interested in; the software searches a data set for locations in space and time that meet the user’s description. In its first stage, Stride Search performs a spatial search of the data set at each timestep by dividing a search domain into circular sectors of constant geodesic radius. Data from a netCDF file is read into memory for each circular search sector. If the data meet or exceed a set of storm identification criteria (defined by the user), a storm is recorded to a linked list. Finally, the linked list is examined and duplicate detections of the same storm are removed and the results are written to an output file. The first stage’s output file is read by a second program that builds storm. Additional identification criteria may be applied at this stage to further classify storms. Storm tracks are the software’s ultimate output and routines are provided for formatting that output for various external software libraries for plotting and tabulating data.

Bosler, Peter↗

Becquerel (Bq) v0.1

Becquerel is a Python package for analyzing nuclear spectroscopic measurements. The core functionalities are reading and writing different spectrum file types, fitting spectral features, performing detector calibrations, and interpreting measurement results. It will include tools for plotting radiation spectra and fits of different spectral features, as well as convenient access to tabulated nuclear data. It relies heavily on the standard scientific Python stack of numpy, scipy, matplotlib, and pandas. It is intended to be general-purpose enough that it can be useful to anyone from an undergraduate taking a laboratory course to the advanced researcher.

Plimley, BrianC↗

lanl/nubhlight

nubhlight is a code for simulating disks of materials around black holes formed after the in-spiral and merger of two-black holes. It is based on the open-source code bhlight. nubhlight models all relevant physics required to solve the post-merger disk problem. This includes: general relativity in a static spacetime, neutrino and weak physics, relativistic magnetohydrodynamics, and the ability to use open-sourced tabulated equations of state provided by stellarcollapse.org.

Miller, Jonah↗