Measurement of the longitudinal diffusion of ionization electrons in the MicroBooNE detector

Accurate knowledge of electron transport properties is vital to understanding the information provided by liquid argon time projection chambers (LArTPCs). Ionization electron drift-lifetime, local electric field distortions caused by positive ion accumulation, and electron diffusion can all significantly impact the measured signal waveforms. This paper presents a measurement of the effective longitudinal electron diffusion coefficient, D L , in MicroBooNE at the nominal electric field strength of 273.9 V/cm. Historically, this measurement has been made in LArTPC prototype detectors. This represents the first measurement in a large-scale (85 tonne active volume) LArTPC operating in a neutrino beam. This is the largest dataset ever used for this measurement. Using a sample of ~70,000 through-going cosmic ray muon tracks tagged with MicroBooNE's cosmic ray tagger system, we measure D L = 3.74 +0.28 -0.29 cm 2 /s.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of the scintillation time response of liquid argon detectors for dark matter search

The scintillation time response of liquid argon has a key role in the discrimination of electronic backgrounds in dark matter search experiments. However, its extraordinary rejection power can be affected by various detector effects such as the delayed light emission of TetraPhenyl Butadiene, the most commonly used wavelength shifter, and the electric drift field applied in Time Projection Chambers. Herein, we characterized the TetraPhenyl Butadiene delayed response and the dependence of the pulse shape discrimination on the electric field, exploiting the data acquired with the ARIS, a small-scale single-phase liquid argon detector exposed to monochromatic neutron and gamma sources at the ALTO facility of IJC Lab in Orsay.

47 OTHER INSTRUMENTATION↗

Scintillation light detection in the 6-m drift length ProtoDUNE Dual Phase liquid argon TPC

The Deep Underground Neutrino Experiment (DUNE) is a leading-edge experiment for long-baseline neutrino oscillation studies, neutrino astrophysics and nucleon decay searches. ProtoDUNE-Dual Phase (DP) is a 6 × 6 × 6 m$^{3}$ liquid argon time-projection-chamber (LArTPC) operated at the CERN Neutrino Platform in 2019–2020 as a prototype of the DUNE far detector. In ProtoDUNE-DP, the scintillation and electroluminescence light produced by cosmic muons in the LArTPC is collected by photomultiplier tubes placed up to 7 m away from the ionizing track. In this paper, we present the performance of the ProtoDUNE-DP photon detection system, comparing different wavelength-shifting techniques and the use of xenon-doped LAr as a promising option for future large LArTPCs. The scintillation light production and propagation processes are analyzed and compared to simulations, improving understanding of the liquid argon properties.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Light detection with power and signal transmission over fiber

The Deep Underground Neutrino Experiment is a next generation long baseline (1300 km) neutrino oscillation experiment. The neutrino beam measurements will be performed by a near detector and far detector. The far detector will consist of four modules, installed 1.5 km deep underground, based on Liquid Argon Time Projection Chamber (LArTPC) technology to detect particles. The Vertical Drift (VD) LArTPC is a recent technology proposed by the DUNE collaboration for the second FD module. In VD, light collection will be optimized by embedding photon detectors within the LArTPC cathode, which is biased at −300 kV. As a result, power must arrive to the Photon Detection System and signal must be transmitted via non-conductive material. The proposed solution is to use Power-over-Fiber and Signal-over-Fiber. An intense validation of the system is being performed by the collaboration at the CERN Neutrino Platform. The design of the system and the results of the validation collected over the first half of 2022 are presented here.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Energy resolution of the LZ detector for high-energy electronic recoils

The LUX-ZEPLIN (LZ) detector is a dual-phase liquid xenon time projection chamber (TPC) installed at the Sanford Underground Research Facility (Lead, South Dakota) at a depth of 1478 meters. Although the main objective of LZ is the direct detection of dark matter, its low background environment allows for the search of other rare processes, such as the neutrinoless double beta decay of xenon isotopes 134 Xe and 136 Xe with the respective Q-values of 826 keV and 2458 keV. The sensitivity of the detector to these decays is directly determined by the energy resolution, which, in turn, is degraded by non-uniformities in detector response. In this work, we present a novel method to correct, in the data, the non-uniformity of the light collected by an array of photosensors in a scintillation detector. This method is based on the knowledge of the light response functions of individual photosensors. With these techniques, we report, at a very early phase of the detector operations, a state-of-the-art energy resolution (σ/μ) of (0.67 ± 0.01)% at 2614 keV for the fiducial volume of 5.6 tonnes of liquid xenon.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Production and testing of the large-area photon detector ArCLight

Compact large-area dielectric photon detectors that ensure modular noble liquid detectors can sense scintillation light signals for triggering and reconstruction purposes with minimal impact to the overall target volume. ArCLight is a small-volume, sizeable sensitive-area detector that consists of a light trap covered in a thin layer of TPB that can be placed inside a time projection chamber's electric field. These sensors are used in the Deep Underground Neutrino Experiment Near Detector liquid argon (DUNE ND-LAr). They are constructed and tested at the University of Bern and will be deployed in the prototype experiment ProtoDUNE-ND. The talk discusses the details of assembling ArCLights, the quality control methods, and the test studies done with LEDs to assess their performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Muon energy reconstruction for applications in neutrino astronomy in the DUNE far detector

Abstract DUNE (Deep Underground Neutrino Experiment) is a proposed long-baseline neutrino oscillation experiment located in the United States. The main physics objectives of DUNE are to measure neutrino oscillations and interactions, search for nucleon decay, observe supernova neutrino bursts and beyond Standard Model (BSM) effects. The DUNE far detector will be located 4850 feet underground at the Sanford Underground Research Facility in Lead, South Dakota. It will house the world's largest liquid-argon time projection chambers (TPC). The DUNE far detector can detect high-energy leptons that arise from interactions of cosmogenic neutrinos and search for neutrinos originating from the decay of weakly-interactive massive particles (WIMPs) annihilations occurring inside the Sun. Selecting upward-going muons reduces the background from cosmic-ray muons. The muon energy is estimated from the electromagnetic showers accompanying the muon, a technique that allows energy reconstruction up to a few hundred TeV.

Instruments & Instrumentation↗

Data-driven precision determination of the material budget in ALICE

The knowledge of the material budget with a high precision is fundamental for measurements of direct photon production using the photon conversion method due to its direct impact on the total systematic uncertainty. Moreover, it influences many aspects of the charged-particle reconstruction performance. In this article, two procedures to determine data-driven corrections to the material-budget description in ALICE simulation software are developed. One is based on the precise knowledge of the gas composition in the Time Projection Chamber. The other is based on the robustness of the ratio between the produced number of photons and charged particles, to a large extent due to the approximate isospin symmetry in the number of produced neutral and charged pions. Both methods are applied to ALICE data allowing for a reduction of the overall material budget systematic uncertainty from 4.5% down to 2.5%. Using these methods, a locally correct material budget is also achieved. The two proposed methods are generic and can be applied to any experiment in a similar fashion.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Deep neural network uncertainty quantification for LArTPC reconstruction

We evaluate uncertainty quantification (UQ) methods for deep learning applied to liquid argon time projection chamber (LArTPC) physics analysis tasks. As deep learning applications enter widespread usage among physics data analysis, neural networks with reliable estimates of prediction uncertainty and robust performance against overconfidence and out-of-distribution (OOD) samples are critical for their full deployment in analyzing experimental data. While numerous UQ methods have been tested on simple datasets, performance evaluations for more complex tasks and datasets are scarce. Here we assess the application of selected deep learning UQ methods on the task of particle classification using the PiLArNet monte carlo 3D LArTPC point cloud dataset. We observe that UQ methods not only allow for better rejection of prediction mistakes and OOD detection, but also generally achieve higher overall accuracy across different task settings. We assess the precision of uncertainty quantification using different evaluation metrics, such as distributional separation of prediction entropy across correctly and incorrectly identified samples, receiver operating characteristic curves (ROCs), and expected calibration error from observed empirical accuracy. We conclude that ensembling methods can obtain well calibrated classification probabilities and generally perform better than other existing methods in deep learning UQ literature.

47 OTHER INSTRUMENTATION↗

Why would you put a flashlight in a dark matter detector?

Silicon photomultipliers (SiPMs) are solid-state, single-photon sensitive, pixelated sensors whose usage for scintillation detection has rapidly increased over the past decade. It is known that the avalanche process within the device, which renders a single photon detectable, can also generate secondary photons which may be detected by a separate device. This effect, known as external crosstalk, could potentially degrade the science goals of future xenon dark matter experiments. In this article, we measure the effect of external crosstalk in a dual-phase, liquid xenon time projection chamber fully instrumented with SiPMs. We then consider the implications for a future xenon dark matter experiment utilizing SiPMs and discuss possible solutions.

47 OTHER INSTRUMENTATION↗

Readout electronics for low occupancy High-Pressure Gas TPCs

High-Pressure Gas Time Projection Chambers (HPgTPCs) have benefits such as low energy thresholds, magnetisability, and 4π acceptance, making them ideal for neutrino experiments such as DUNE. We present the design of an FPGA-based solution optimised for Gaseous Argon Near Detector (ND-GAr), which is part of the Phase-II more capable near detector for DUNE. These electronics reduce the cost significantly compared to using collider readout electronics, which are typically designed for much higher occupancy and therefore, for example, need much larger numbers of FPGAs and power per channel. We demonstrate the performance of our electronics with the Teststand for an Overpressurised Argon Detector (TOAD) at Fermilab in the US at a range of pressures and gas mixtures up to 4.5 barA, reading out ∼10 000 channels from a Multi-Wire Proportional Chamber (MWPC). The operation took place between April and July of 2024. We measure the noise characteristics of the system to be sufficiently low, and we identify sources of noise that can be further mitigated in the next iteration. We also note that the cooling scheme used in the test requires improvement before full-scale deployment. Despite these necessary improvements, we show that the system can fulfil the needs of a HPgTPC for a fraction of the price of collider readout electronics.

Data acquisition concepts↗

Characterization of lateral amorphous selenium photodetectors for low-photon and VUV detection at cryogenic temperatures

The performance of amorphous selenium (a-Se) as a cryogenic photodetector material is evaluated through a series of experiments using laterally structured devices operated in a custom optical test stand. These studies investigate the response of a-Se detectors to low-photon fluxes at high electric fields near avalanche conditions, the linearity of the photoconductive response over a wide dynamic range and the direct detection of narrowband 130 nm vacuum ultraviolet (VUV) illumination. At 87 K, matched-filter analysis shows reliable single-shot detection with efficiencies ≥80% and area under the curve (AUC) ≥ 0.85 using as few as ∼ 6800 incident 401 nm photons, corresponding to ∼ 3400 photons within field-active regions after accounting for geometric constraints. Measurements are performed at cryogenic temperatures using calibrated photon fluxes derived from a silicon photomultiplier reference and a characterized optical filter stack. Additional experiments using a tellurium-doped a-Se (a-SeTe) device explore the material's behavior under identical test conditions and demonstrate that avalanche is achievable in a-SeTe at cryogenic temperatures. The results demonstrate reproducible low-noise operation, VUV sensitivity and field-dependent gain behavior in a lateral a-Se architecture, representing the first reported observation of avalanche multiplication in laterally structured a-Se and a-SeTe devices at cryogenic temperatures. These findings support the potential integration of laterally structured a-Se devices into next-generation pixelated liquid-argon time projection chambers (TPCs) requiring scalable, high-field-compatible photon detection systems.

Amorphous selenium↗

Improving ICARUS track reconstruction algorithms

The ICARUS experiment is part of the Short-Baseline Neutrino program at Fermilab. Its primary objective is to explore the possible existence of sterile neutrinos in the O(1 eV) mass range and to clarify the anomalies observed in the Liquid Scintillator Neutrino Detector and MiniBooNE experiments. The ICARUS-T600 detector is a Liquid Argon Time Projection Chamber, capable of producing high-resolution 3D images and precise calorimetric measurements of ionizing particles. This technology allows for a detailed study of neutrino interactions across a broad energy range, from a few keV to several hundred GeV. The track reconstruction is achieved through a software framework that applies a series of pattern recognition algorithms, transforming raw detector signals into fully reconstructed event topologies. This process involves identifying interaction vertices, particle tracks, and electromagnetic showers within the TPC. However, in certain cases, these algorithms may mistakenly break a single particle track into several shorter segments, interpreting each as a distinct particle. Since track length is used to estimate the particle's energy, such fragmentation can result in an energy underestimation of several hundred MeV. Furthermore, when a track is split into multiple segments, the particle identification (which relies on analyzing the energy loss as a function of the residual range) may fail, potentially leading to the loss of the entire event. To mitigate this problem, we have developed a dedicated algorithm designed to identify and reconnect (“stitch”) the tracks that were erroneously divided into multiple segments.

Ricci, Alessandro Maria [Pisa U.; INFN, Pisa] (ORC↗

Characterization of UV optical components for photon detector calibration in liquid argon TPCs

Large liquid argon time projection chambers (LArTPCs)require stable and well-characterized delivery of ultraviolet (UV)light for in situ calibration of photosensors at cryogenictemperatures. This article reports bench-top and cryogenicmeasurements of the optical components used in a UV lightcalibration system, including multi-mode fused-silica fibers,SMA-to-SMA connectors, optical fiber feedthroughs, andlight-diffuser assemblies. Light loss in several fiber types and SMAconnectors was measured across wavelengths from275–970 mm. In addition,light-loss measurements of the tested fibers after severalliquid-nitrogen thermal cycles showed no statistically significantdegradation relative to baseline measurements, and high-rate pulsedexposure (30–90 million pulses from a275 nm LED) likewise showed nomeasurable aging in jacketed fibers. A compact, palm-sized,3D-printed PEEK diffuser housing with stacked UV-grade fused-silicadiffusers yields Lambertian emission and the most uniform angulardistribution. Optical components exhibiting improved UV transmissionwere deployed successfully in multiple DUNE small- and large-scaleprototypes, demonstrating reliable operation of UV light calibrationsystem. These findings inform component selection and calibrationprocedures for achieving reliable, uniform UV light delivery inlarge-scale cryogenic detectors such as DUNE.

Behera, B. [South Dakota Sch. Mines Tech.] (ORCID:↗

Analysis of a Large Sample of Neutrino-Induced Muons with the ArgoNeuT Detector

ArgoNeuT, or Argon Neutrino Test, is a 170 liter liquid argon time projection chamber designed to collect neutrino interactions from the NuMI beam at Fermi National Accelerator Laboratory. ArgoNeuT operated in the NuMI low-energy beam line directly upstream of the MINOS Near Detector from September 2009 to February 2010, during which thousands of neutrino and antineutrino events were collected. The MINOS Near Detector was used to measure muons downstream of ArgoNeuT. Though ArgoNeuT is primarily an R&D project, the data collected provide a unique opportunity to measure neutrino cross sections in the 0.1-10 GeV energy range. Fully reconstructing the muon from these interactions is imperative for these measurements. This paper focuses on the complete kinematic reconstruction of neutrino-induced through-going muons tracks. Analysis of this high statistics sample of minimum ionizing tracks demonstrates the reliability of the geometric and calorimetric reconstruction in the ArgoNeuT detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Measurement of the Absorption of Liquid Argon Scintillation Light by Dissolved Nitrogen at the Part-Per-Million Level

Here we report on a measurement of the absorption length of scintillation light in liquid argon due to dissolved nitrogen at the part-per-million (ppm)level. We inject controlled quantities of nitrogen into a high purity volume of liquid argon and monitor the light yield from an alpha source.The source is placed at different distances from a cryogenic photomultiplier tube assembly. By comparing the light yield from each position we extract the absorption cross section of nitrogen. We find that nitrogen absorbs argon scintillation light with strength of (1.51±0.15) × 10 $-$4 cm $-$1 ppm $-$1 , correspondingto an absorption cross section of (4.99±0.51) × 10 $-$21 cm 2 molecule $-$1 .We obtain the relationship between absorption length and nitrogenconcentration over the 0 to 50 ppm range and discuss the implicationsfor the design and data analysis of future large liquid argon time projection chamber (LArTPC)detectors. Our results indicate that for a current-generation LArTPC, wherea concentration of 2 parts per million of nitrogen is expected, the attenuationlength due to nitrogen will be 30±3 meters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Testing of Cryogenic Photomultiplier Tubes for the MicroBooNE Experiment

The MicroBooNE detector, to be located on axis in the Booster Neutrino Beamline (BNB) at the Fermi National Accelerator Laboratory (Fermilab), consists of two main components: a large liquid argon time projection chamber (LArTPC), and a light collection system. Thirty-two 8-inch diameter Hamamatsu R5912-02mod cryogenic photomultiplier tubes (PMTs) will detect the scintillation light generated in the liquid argon (LAr). This article first describes the MicroBooNE PMT performance test procedures, including how the light collectionsystem functions in the detector, and the design of the PMT base. The design of the cryogenic test stand is then discussed, and finally the results of the cryogenic tests are reported.

Briese, T.↗

DarkSide search for dark matter

The DarkSide staged program utilizes a two-phase time projection chamber (TPC) with liquid argon as the target material for the scattering of dark matter particles. Efficient background reduction is achieved using low radioactivity underground argon as well as several experimental handles such as pulse shape, ratio of ionization over scintillation signal, 3D event reconstruction, and active neutron and muon vetos. The DarkSide-10 prototype detector has proven high scintillation light yield, which is a particularly important parameter as it sets the energy threshold for the pulse shape discrimination technique. The DarkSide-50 detector system, currently in commissioning phase at the Gran Sasso Underground Laboratory, will reach a sensitivity to dark matter spin-independent scattering cross section of 10 -45 cm 2 within 3 years of operation.