Search NASA⌕ Search

SEARCH · Search NASA

Results for “quantitative imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Quantitative microstructural investigation of 3D-printed and cast cement pastes using micro-computed tomography and image analysis

Highlights: • Processing alters the microstructure in 3D-printed lamellar cubic element. • A unique patterned and connected pore microstructure network exists. • Micro-channels are connected through micro-pores present at interfaces regions. • Three distinct pore volume domains exists in hardened microstructure. • Volume and frequency of pore, hydrated, and unhydrated clusters are dissimilar. Microstructural phases and mechanical properties of lamellar 3D-printed and cast hardened cement paste (hcp) elements were investigated using a lab-based X-ray microscope at two levels of magnification (0.4× and 4×). K-means clustering was used for quantitative image analysis. The entire volume of intact 3-days-old 3D-printed and cast hcp elements was characterized at 0.4× magnification. Three microstructural features (macro-pores, micro-channels, and interfacial micro-pores) were found to reside in three distinct pore size domains. The largest pores of the 3D-printed element were larger than the largest pores of the reference cast hcp element. Moreover, the smallest pore sizes of the 3D-printed element were found to be smaller than those present in the cast counterparts. Micro-channels were found to be connected to one another through the micro-pores present at interfacial regions, indicating the presence of a uniquely patterned and interconnected pore network. The role of locally weak and porous interfaces on mechanical response and fracture properties is discussed.

36 MATERIALS SCIENCE↗

Simultaneous imaging of the ferromagnetic and ferroelectric structure in multiferroic heterostructures

By measuring the spin polarization of secondary electrons and the intensity of backscattered electrons generated in a scanning electron microscope, we are able to simultaneously image the ferromagnetic domain structure of a ferromagnetic thin film and the ferroelectric domain structure of the underlying ferroelectric substrate upon which it is grown. Simultaneous imaging allows straightforward, quantitative measurements of the correlations in these complex multiferroic systems. We have successfully imaged domains in CoFe/BFO and Fe/BTO, two systems with very different ferromagnet/ferroelectric coupling mechanisms, demonstrating how this technique provides a new local probe of magneto electric/strictive effects in multiferroic heterostructures.

36 MATERIALS SCIENCE↗

A database system to support image algorithm evaluation

The design is given of an interactive image database system IMDB, which allows the user to create, retrieve, store, display, and manipulate images through the facility of a high-level, interactive image query (IQ) language. The query language IQ permits the user to define false color functions, pixel value transformations, overlay functions, zoom functions, and windows. The user manipulates the images through generic functions. The user can direct images to display devices for visual and qualitative analysis. Image histograms and pixel value distributions can also be computed to obtain a quantitative analysis of images.

Lien, Y. E.↗

What do you gain from deconvolution? - Observing faint galaxies with the Hubble Space Telescope Wide Field Camera

We describe experiments with deconvolutions of simulations of deep HST Wide Field Camera images containing faint, compact galaxies to determine under what circumstances there is a quantitative advantage to image deconvolution, and explore whether it is (1) helpful for distinguishing between stars and compact galaxies, or between spiral and elliptical galaxies, and whether it (2) improves the accuracy with which characteristic radii and integrated magnitudes may be determined. The Maximum Entropy and Richardson-Lucy deconvolution algorithms give the same results. For medium and low S/N images, deconvolution does not significantly improve our ability to distinguish between faint stars and compact galaxies, nor between spiral and elliptical galaxies. Measurements from both raw and deconvolved images are biased and must be corrected; it is easier to quantify and remove the biases for cases that have not been deconvolved. We find no benefit from deconvolution for measuring luminosity profiles, but these results are limited to low S/N images of very compact (often undersampled) galaxies.

Schade, David J.↗

Deep Learning Analysis of Polaritonic Wave Images

Deep learning (DL) is an emerging analysis tool across the sciences and engineering. Encouraged by the successes of DL in revealing quantitative trends in massive imaging data, we applied this approach to nanoscale deeply subdiffractional images of propagating polaritonic waves in complex materials. Utilizing the convolutional neural network (CNN), we developed a practical protocol for the rapid regression of images that quantifies the wavelength and the quality factor of polaritonic waves. Using simulated near-field images as training data, the CNN can be made to simultaneously extract polaritonic characteristics and material parameters in a time scale that is at least 3 orders of magnitude faster than common fitting/processing procedures. The CNN-based analysis was validated by examining the experimental near-field images of charge-transfer plasmon polaritons at graphene/α-RuCl3 interfaces. Our work provides a general framework for extracting quantitative information from images generated with a variety of scanning probe methods.

97 MATHEMATICS AND COMPUTING↗

Multi-System Verification of Registrations for Image-Guided Radiotherapy in Clinical Trials

Purpose: To provide quantitative information on the image registration differences from multiple systems for image-guided radiotherapy (IGRT) credentialing and margin reduction in clinical trials. Methods and Materials: Images and IGRT shift results from three different treatment systems (Tomotherapy Hi-Art, Elekta Synergy, Varian Trilogy) have been sent from various institutions to the Image-Guided Therapy QA Center (ITC) for evaluation for the Radiation Therapy Oncology Group (RTOG) trials. Nine patient datasets (five head-and-neck and four prostate) were included in the comparison, with each patient having 1-4 daily individual IGRT studies. In all cases, daily shifts were re-calculated by re-registration of the planning CT with the daily IGRT data using three independent software systems (MIMvista, FocalSim, VelocityAI). Automatic fusion was used in all calculations. The results were compared with those submitted from institutions. Similar regions of interest (ROIs) and same initial positions were used in registrations for inter-system comparison. Different slice spacings for CBCT sampling and different ROIs for registration were used in some cases to observe the variation of registration due to these factors. Results: For the 54 comparisons with head-and-neck datasets, the absolute values of differences of the registration results between different systems were 2.6 {+-} 2.1 mm (mean {+-} SD; range 0.1-8.6 mm, left-right [LR]), 1.7 {+-} 1.3 mm (0.0-4.9 mm, superior-inferior [SI]), and 1.8 {+-} 1.1 mm (0.1-4.0 mm, anterior-posterior [AP]). For the 66 comparisons in prostate cases, the differences were 1.1 {+-} 1.0 mm (0.0-4.6 mm, LR), 2.1 {+-} 1.7 mm (0.0-6.6 mm, SI), and 2.0 {+-} 1.8 mm (0.1-6.9 mm, AP). The differences caused by the slice spacing variation were relatively small, and the different ROI selections in FocalSim and MIMvista also had limited impact. Conclusion: The extent of differences was reported when different systems were used for image registration. Careful examination and quality assurance of the image registration process are crucial before considering margin reduction using IGRT in clinical trials.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-84: Quantitative Dosimetry Assessment of the Impact of Image Artifacts of Metal Implants in Spinal SABR Treatment

Purpose: Metal rods are frequently used to stabilize the spine in patients with metastatic disease. The high Z material causes imaging artifacts in the surrounding tissue in CT scans, which introduces dosimetric uncertainty when inhomogeneity correction is enabled for radiation treatment planning. The purpose of this study is to quantify the dosimetric deviations caused by the imaging artifacts and to evaluate the effectiveness of using Hounsfield units (HU) overwriting to reduce dosimetric uncertainties. Methods: We retrospectively reviewed treatment plans for 4 patients with metal implants who received stereotactic ablative radiation therapy (SABR) for metastatic disease to the spine on Tomotherapy HiArt. For all four patients, the region of imaging artifact surrounding the metal implants was contoured and the pixel HU’s were overwritten to be water equivalent. We then generated adaptive treatment plans for these patients using the MVCT pretreatment set up images and batched beamlets in the original treatment plans. The dosimetry deviation between the adaptive and original plans were compared and quantitatively analyzed. Results: For three out of four patient, the major OAR (spinal cord) dose (0.35cc or 10% according to protocols and fractionation) increased (2.7%, 5.5%, 0%, 3.9%, mean=3.0±2.3%, p=0.04), and the PTV dose (D90 or D95 as per prescription) increased for all four patients ( 2%, 5%, 0.7%, 3.6%, mean=2.8±1.9%, p=0.03) in the adaptive plan with HU overwriting. The average point dose deviation of the Tomotherapy DQA for the same patients was −1.0±1.0%. For plans without HU overwriting, the dose deviation from the treatment plan will increase. Conclusion: The metal implant and the imaging artifacts may cause a significant dosimetric impact on radiation treatment plans for spinal disease. The dose to the PTV and the spinal cord was under-calculated in treatment plans without considering the imaging artifacts. HU overwriting can reduce the dosimetry un-certainty.

60 APPLIED LIFE SCIENCES↗

Three-dimensional coherent X-ray diffractive imaging of whole frozen-hydrated cells

Here, a structural understanding of whole cells in three dimensions at high spatial resolution remains a significant challenge and, in the case of X-rays, has been limited by radiation damage. By alleviating this limitation, cryogenic coherent diffractive imaging (cryo-CDI) can in principle be used to bridge the important resolution gap between optical and electron microscopy in bio-imaging. Here, the first experimental demonstration of cryo-CDI for quantitative three-dimensional imaging of whole frozen-hydrated cells using 8 Kev X-rays is reported. As a proof of principle, a tilt series of 72 diffraction patterns was collected from a frozen-hydrated Neospora caninum cell and the three-dimensional mass density of the cell was reconstructed and quantified based on its natural contrast. This three-dimensional reconstruction reveals the surface and internal morphology of the cell, including its complex polarized sub-cellular structure. Finally, it is believed that this work represents an experimental milestone towards routine quantitative three-dimensional imaging of whole cells in their natural state with spatial resolutions in the tens of nanometres.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A DESCRIPTION OF QUASAR VARIABILITY MEASURED USING REPEATED SDSS AND POSS IMAGING

We provide a quantitative description and statistical interpretation of the optical continuum variability of quasars. The Sloan Digital Sky Survey (SDSS) has obtained repeated imaging in five UV-to-IR photometric bands for 33,881 spectroscopically confirmed quasars. About 10,000 quasars have an average of 60 observations in each band obtained over a decade along Stripe 82 (S82), whereas the remaining {approx}25,000 have 2-3 observations due to scan overlaps. The observed time lags span the range from a day to almost 10 years, and constrain quasar variability at rest-frame time lags of up to 4 years, and at rest-frame wavelengths from 1000 A to 6000 A. We publicly release a user-friendly catalog of quasars from the SDSS Data Release 7 that have been observed at least twice in SDSS or once in both SDSS and the Palomar Observatory Sky Survey, and we use it to analyze the ensemble properties of quasar variability. Based on a damped random walk (DRW) model defined by a characteristic timescale and an asymptotic variability amplitude that scale with the luminosity, black hole mass, and rest wavelength for individual quasars calibrated in S82, we can fully explain the ensemble variability statistics of the non-S82 quasars such as the exponential distribution of large magnitude changes. All available data are consistent with the DRW model as a viable description of the optical continuum variability of quasars on timescales of {approx}5-2000 days in the rest frame. We use these models to predict the incidence of quasar contamination in transient surveys such as those from the Palomar Transient Factory and Large Synoptic Survey Telescope.

79 ASTRONOMY AND ASTROPHYSICS↗

State-of-the-art γ-ray assay of 86 Y for medical imaging

An emerging direction in nuclear medicine is the coupling of a therapeutic isotope with an imaging isotope to form a so-called theranostic pair, which allows one to quantitatively track and image the delivery of the therapeutic isotope. 90 Y is used in several therapy applications and a convenient candidate imaging partner is the positron emitter 86 Y. A 27.6 MBq source of 86 Y was produced at the University of Wisconsin and assayed with the Gammasphere array at Argonne National Laboratory. Over 200 γ-ray transitions were identified, more than double that which was previously known. In conclusion, the positron emission probability inferred from the present level scheme leads to 27.9(12)%, an important (≈14%) reduction with respect to the previously recommended value.

59 ≤ A ≤ 89↗

A sensitive infrared imaging up converter and spatial coherence of atmospheric propagation

An infrared imaging technique based on the nonlinear interaction known as upconversion was used to obtain images of several astronomical objects in the 10 micrometer spectral region, and to demonstrate quantitatively the sharper images allowed for wavelengths beyond the visible region. The deleterious effects of atmospheric inhomogeneities on telescope resolution were studied in the infrared region using the technique developed. The low quantum efficiency of the device employed severely limited its usefulness as an astronomical detector.

Boyd, R. W.↗

Three-dimensional imaging of hidden objects using positron emission backscatter

Positron emission backscatter imaging is a technique for interrogation and three-dimensional (3-D) reconstruction of hidden objects when we only have access to the objects from one side. Using time-of-flight differences in detected direct and backscattered positron-emitted photons, we construct 3-D images of target objects. Recently at Los Alamos National Laboratory, a fully three-dimensional imaging system has been built and the experimental results are discussed in this paper. Quantitative analysis of images reconstructed in both two- and three-dimensions are also presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantitative phase retrieval with arbitrary pupil and illumination

We present a general algorithm for combining measurements taken under various illumination and imaging conditions to quantitatively extract the amplitude and phase of an object wave. The algorithm uses the weak object transfer function, which incorporates arbitrary pupil functions and partially coherent illumination. The approach is extended beyond the weak object regime using an iterative algorithm. Finally, we demonstrate the method on measurements of Extreme Ultraviolet Lithography (EUV) multilayer mask defects taken in an EUV zone plate microscope with both a standard zone plate lens and a zone plate implementing Zernike phase contrast.

97 MATHEMATICS AND COMPUTING↗

Mapping Electrical Crosstalk in Pixelated Sensor Arrays

Electronic coupling effects such as Inter-Pixel Capacitance (IPC) affect the quantitative interpretation of image data from CMOS, hybrid visible and infrared imagers alike. Existing methods of characterizing IPC do not provide a map of the spatial variation of IPC over all pixels. We demonstrate a deterministic method that provides a direct quantitative map of the crosstalk across an imager. The approach requires only the ability to reset single pixels to an arbitrary voltage, different from the rest of the imager. No illumination source is required. Mapping IPC independently for each pixel is also made practical by the greater S/N ratio achievable for an electrical stimulus than for an optical stimulus, which is subject to both Poisson statistics and diffusion effects of photo-generated charge. The data we present illustrates a more complex picture of IPC in Teledyne HgCdTe and HyViSi focal plane arrays than is presently understood, including the presence of a newly discovered, long range IPC in the HyViSi FPA that extends tens of pixels in distance, likely stemming from extended field effects in the fully depleted substrate. The sensitivity of the measurement approach has been shown to be good enough to distinguish spatial structure in IPC of the order of 0.1%.

focal plane array↗

SU-E-J-230: Evaluation of ViewRay 0.35 T MRI Normal Structure Segmentation

Purpose: In order to take advantage of the high resolution soft tissue imaging available in MR images, we investigated 3D images obtained with the low field 0.35 T MR in ViewRay to serve as an alternative to CT scans for radiotherapy treatment planning. In these images, normal and target structure delineation can be visualized. Assessment is based upon comparison with the CT images and the ability to produce comparable contours. Methods: Routine radiation oncology CT scans were acquired on five patients. Contours of brain, brainstem, esophagus, heart, lungs, spinal cord, and the external body were drawn. The same five patients were then scanned on the ViewRay TrueFISP-based imaging pulse sequence. The same organs were selected on the MR images and compared to those from the CT scan. Physical volume and the Dice Similarity Coefficient (DSC) were used to assess the contours from the two systems. Image quality stability was quantitatively ensured throughout the study following the recommendations of the ACR MR accreditation procedure. Results: The highest DSC of 0.985, 0.863, and 0.843 were observed for brain, lungs, and heart respectively. On the other hand, the brainstem, spinal cord, and esophagus had the lowest DSC. Volume agreement was most satisfied for the heart (within 5%) and the brain (within 2%). Contour volume for the brainstem and lung (a widely dynamic organ) varied the most (27% and 19%). Conclusion: The DSC and volume measurements suggest that the results obtained from ViewRay images are quantitatively consistent and comparable to those obtained from CT scans for the brain, heart, and lungs. MR images from ViewRay are well-suited for treatment planning and for adaptive MRI-guided radiotherapy. The physical data from 0.35 T MR imaging is consistent with our geometrical understanding of normal structures.

60 APPLIED LIFE SCIENCES↗

The SCIFLI Airborne Observation of Artemis 1 Ascent

SCIFLI, The Scientifically Calibrated In-Flight Imagery (https://scifli.larc.nasa.gov/), team at NASA Langley Research Center specializes in the collection of multispectral data for space vehicles during Ascent and Entry, Descent, and Landing (EDL) observations. Multispectral datasets are invaluable across the NASA Agency and to commercial stakeholders for evaluating the performance of launch and re-entry space vehicles and ensuring the safety of the scientific research community. The launch of Artemis 1 marked the initiation of NASA returning to lunar exploration. SCIFLI’s Airborne Multispectral Imager (SAMI) was deployed by the SCIFLI team to scientifically document the historic event and provide the NASA research community with aerial footage of the event in wavelength channels ranging from the ultraviolet (UV) to the visible (VIS) to mid-wave infrared (MWIR). SAMI was designed to spectrally image unique aerothermal phenomena during the Artemis 1 launch. The use of these datasets captured in-flight during the launch will provide insight to research organizations across the Agency; aiding in validation efforts for simulations and modeling that contributed to the kickoff of the Agency’s resurgence to lunar exploration. This presentation will focus on the imagery captured on SAMI by the WB-57 team on November 16th, 2022, during the observation. Imaging objectives were identified and considered beforehand to determine the configuration of the SAMI instrument for the imaging mission. SCIFLI and Opto-Knowledge Systems, Inc. (OKSI) performed a thorough review of the datasets collected to identify and characterize aerothermal phenomena occurring during the observation. Additional post-processing was completed to provide quantitatively calibrated temperature images of the rocket during the observation. Some of the candidates were not optimal for quantitative temperature extraction due to common degradation factors, but after various image enhancements they proved useful for qualitatively characterizing different phenomena during the observation.

Artemis1↗

Avoiding full corrections in dynamic SPECT images impacts the performance of SPECT myocardial blood flow quantitation

Introduction: This study investigated the performance of SPECT myocardial blood flow (MBF) quantitation lacking full physical corrections (All Corr) in dynamic SPECT (DySPECT) images. Methods: Eleven healthy normal volunteers (HVT) and twenty-four patients with angiography-documented CAD were assessed. All Corr in {sup 99m}Tc-sestamibi DySPECT encompassed noise reduction (NR), resolution recovery (RR), and corrections for scatter (SC) and attenuation (AC), otherwise no correction (NC) or only partial corrections. The performance was evaluated by quality index (R{sup 2}) and blood-pool spillover index (FBV) in kinetic modeling, and by rest flow (RMBF) and stress flow (SMBF) compared with those of All Corr. Results: In HVT group, NC diminished 2-fold flow uniformity with the most degraded quality (15%-18% reduced R{sup 2}) and elevated spillover effect (45%-50% increased FBV). Consistently higher RMBF and SMBF were discovered in both groups (HVT 1.54/2.31 higher; CAD 1.60/1.72; all P < .0001). Bland-Altman analysis revealed positive flow bias (HVT 0.9-2.6 mL/min/g; CAD 0.7-1.3) with wide ranges of 95% CI of agreement (HVT NC −1.9-7.1; NR −0.4-4.4; NR + SC −1.1-4.3; NR + SC + RR −0.7-2.5) (CAD NC −1.2-3.8; NR −1.0-2.8; NR + SC −1.0-2.5; NR + SC + RR −1.1-2.6). Conclusions: Uncorrected physical interference in DySPECT images can extensively impact the performance of MBF quantitation. Full physical corrections should be considered to warrant this tool for clinical utilization.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantitative Assessment of Heterogeneity in Tumor Metabolism Using FDG-PET

Purpose: [{sup 18}F]-fluorodeoxyglucose-positron emission tomography (FDG-PET) images are usually quantitatively analyzed in 'whole-tumor' volumes of interest. Also parameters determined with dynamic PET acquisitions, such as the Patlak glucose metabolic rate (MR{sub glc}) and pharmacokinetic rate constants of two-tissue compartment modeling, are most often derived per lesion. We propose segmentation of tumors to determine tumor heterogeneity, potentially useful for dose-painting in radiotherapy and elucidating mechanisms of FDG uptake. Methods and Materials: In 41 patients with 104 lesions, dynamic FDG-PET was performed. On MR{sub glc} images, tumors were segmented in quartiles of background subtracted maximum MR{sub glc} (0%-25%, 25%-50%, 50%-75%, and 75%-100%). Pharmacokinetic analysis was performed using an irreversible two-tissue compartment model in the three segments with highest MR{sub glc} to determine the rate constants of FDG metabolism. Results: From the highest to the lowest quartile, significant decreases of uptake (K{sub 1}), washout (k{sub 2}), and phosphorylation (k{sub 3}) rate constants were seen with significant increases in tissue blood volume fraction (V{sub b}). Conclusions: Tumor regions with highest MR{sub glc} are characterized by high cellular uptake and phosphorylation rate constants with relatively low blood volume fractions. In regions with less metabolic activity, the blood volume fraction increases and cellular uptake, washout, and phosphorylation rate constants decrease. These results support the hypothesis that regional tumor glucose phosphorylation rate is not dependent on the transport of nutrients (i.e., FDG) to the tumor.

62 RADIOLOGY AND NUCLEAR MEDICINE↗