Search NASA⌕ Search

SEARCH · Search NASA

Results for “reference cells”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

In Situ Liquid Electron Microscope Cells Strongly Attenuate Electrochemical Behavior

In situ electrochemical Scanning Transmission Electron Microscopy (ec-S/TEM) probes the dynamics of electrochemical processes in real time and at high spatial resolution. This method utilizes microfabricated electrochemical cells, with enclosed dimensions of 800 μm wide, 800 μm long, and 1–2 μm tall, with electron-transparent silicon nitride windows. Working, counter, and reference electrodes in the configuration studied are deposited Pt with a planar surface area of about 1 μm 2 and a height of 50 nm. The cell confines the electrolyte within a 1 μm tall channel, and the microfabricated electrodes have a non-standard geometry, are coplanar, and are not front-facing. As such, standard assumptions of electrochemical experiments do not apply. COMSOL modeling was used to compare and contrast differences in electrochemical behavior between conventional experimental setups and the in situ ec-S/TEM cells. Cell height strongly affected voltammogram measurements: peak magnitudes and shifts correlate directly to cell height. Reactant concentration above the electrode quickly decreases during deposition, leading to a planar diffusion-dominated regime. The concentration gradient prioritizes particle growth along the thin edges of the electrode and not on the planar part of the electrode. Experiments done in the ec-S/TEM ex situ of a TEM verify the model’s accuracy.

Wittman, Reed M. [Oak Ridge National Laboratory (O↗

Comparison of conventional vs. modular hydrogen refueling stations and on-site production vs. delivery.

To meet the needs of public and private stakeholders involved in the development, construction, and operation of hydrogen fueling stations needed to support the widespread roll-out of hydrogen fuel cell electric vehicles, this work presents publicly available station templates and analyses. These ‘Reference Stations’ help reduce the cost and speed the deployment of hydrogen stations by providing a common baseline with which to start a design, enable quick assessment of potential sites for a hydrogen station, identify contributors to poor economics, and suggest areas of research. This work presents layouts, bills of materials, piping and instrumentation diagrams, and detailed analyses of five new station designs. In the near term, delivered hydrogen results in a lower cost of hydrogen compared to on-site production via steam methane reforming or electrolysis, although the on-site production methods have other advantages. Modular station concepts including on-site production can reduce lot sizes from conventional assemble-on-site stations.

08 HYDROGEN↗

Comparison of conventional vs. modular hydrogen refueling stations, and on-site production vs. delivery

To meet the needs of public and private stakeholders involved in the development, construction, and operation of hydrogen fueling stations needed to support the widespread roll-out of hydrogen fuel cell electric vehicles, this work presents publicly available station templates and analyses. These 'Reference Stations' help reduce the cost and speed the deployment of hydrogen stations by providing a common baseline with which to start a design, enable quick assessment of potential sites for a hydrogen station, identify contributors to poor economics, and suggest areas of research. This work presents layouts, bills of materials, piping and instrumentation diagrams, and detailed analyses of five new station designs. In the near term, delivered hydrogen results in a lower cost of hydrogen compared to on-site production via steam methane reforming or electrolysis, although the on-site production methods have other advantages. Modular station concepts including on-site production can reduce lot sizes from conventional assemble-on-site stations.

08 HYDROGEN↗

Minimum silicon wafer thickness for ID wafering

An analytical model, based on fracture mechanics analysis, is proposed for estimating the minimum wafer thickness as a function of the diameter requirement for solar cells. The conditions under which the model can be applied are discussed with reference to the critical flaw size, the applied force, and the width of the side support. It is shown that the equivalent cantilever force applied during ID slicing can be estimated from the wafering mechanical yield data. The width of the wafer side support was found to be a significant factor in controlling the minimum allowable wafer thickness during slicing. Wafer side support width requirements were found to increase with decreasing wafer thickness.

Chen, C. P.↗

Space Shuttle 2 advanced space transportation system, volume 2

To determine the best configuration from all candidate configurations, it was necessary first to calculate minimum system weights and performance. To optimize the design, it is necessary to vary configuration-specific variables such as total system weight, thrust-to-weight ratios, burn durations, total thrust available, and mass fraction for the system. Optimizing each of these variables at the same time is technically unfeasible and not necessarily mathematically possible. However, discrete sets of data can be generated which will eliminate many candidate configurations. From the most promising remaining designs, a final configuration can be selected. Included are the three most important designs considered: one which closely approximates the design criteria set forth in a Marshall Space Flight Center study of the Shuttle 2; the configuration used in the initial proposal; and the final configuration. A listing by cell of the formulas used to generate the aforementioned data is included for reference.

Adinaro, James N.↗

13CO2/12CO2 isotopic ratio measurements using a difference frequency-based sensor operating at 4.35 micrometers

A portable modular gas sensor for measuring the 13C/12C isotopic ratio in CO2 with a precision of 0.8%(+/-1 sigma) was developed for volcanic gas emission studies. This sensor employed a difference frequency generation (DFG)-based spectroscopic source operating at 4.35 micrometers (approximately 2300 cm-1) in combination with a dual-chamber gas absorption cell. Direct absorption spectroscopy using this specially designed cell permitted rapid comparisons of isotopic ratios of a gas sample and a reference standard for appropriately selected CO2 absorption lines. Special attention was given to minimizing undesirable precision degrading effects, in particular temperature and pressure fluctuations.

NASA Discipline Life Sciences Technologies↗

Measuring Thermodynamic Properties of Metals and Alloys With Knudsen Effusion Mass Spectrometry

This report reviews Knudsen effusion mass spectrometry (KEMS) as it relates to thermodynamic measurements of metals and alloys. First, general aspects are reviewed, with emphasis on the Knudsen-cell vapor source and molecular beam formation, and mass spectrometry issues germane to this type of instrument are discussed briefly. The relationship between the vapor pressure inside the effusion cell and the measured ion intensity is the key to KEMS and is derived in detail. Then common methods used to determine thermodynamic quantities with KEMS are discussed. Enthalpies of vaporization, the fundamental measurement, are determined from the variation of relative partial pressure with temperature using the second-law method or by calculating a free energy of formation and subtracting the entropy contribution using the third-law method. For single-cell KEMS instruments, measurements can be used to determine the partial Gibbs free energy if the sensitivity factor remains constant over multiple experiments. The ion-current ratio method and dimer-monomer method are also viable in some systems. For a multiple-cell KEMS instrument, activities are obtained by direct comparison with a suitable component reference state or a secondary standard. Internal checks for correct instrument operation and general procedural guidelines also are discussed. Finally, general comments are made about future directions in measuring alloy thermodynamics with KEMS.

Copland, Evan H.↗

Mass Gauging Demonstrator for Any Gravitational Conditions

The present invention is a mass gauging interferometry system used to determine the volume contained within a tank. By using an optical interferometric technique to determine gas density and/or pressure a much smaller compression volume or higher fidelity measurement is possible. The mass gauging interferometer system is comprised of an optical source, a component that splits the optical source into a plurality of beams, a component that recombines the split beams, an optical cell operatively coupled to a tank, a detector for detecting fringes, and a means for compression. A portion of the beam travels through the optical cell operatively coupled to the tank, while the other beam(s) is a reference.

Korman, Valentin↗

Design and Indoor Validation of 'DUSST': A Novel Low-Maintenance Soiling Station: Preprint

One of the most relevant concerns of photovoltaic (PV) systems today is the accumulation of dust - commonly referred to as 'soiling' - because it reduces the light that reaches the solar cells (1). This soiling has a significant impact on the energy delivered by PV modules, and hence, on the cost of solar electricity. Soiling losses have been investigated around the world and show a noteworthy dependence on site location. The annual soiling losses for the United States are within 0-6%, whereas in dustier regions, such as the Middle East, India, or China, these loses can reach peak values of up to 70%. These power drops cannot be directly translated into annual energy losses, but they can still lead to higher annual energy losses compared to those in the USA or Europe. In this sense, identifying soiling becomes essential for scheduling the most adequate cleaning strategy and maximizing the PV energy production, thus reducing the operating costs.

14 SOLAR ENERGY↗

Oxygen potentials and phase equilibria in the system Ca–Co–O and thermodynamic properties of Ca{sub 3}Co{sub 2}O{sub 6} and Ca{sub 3}Co{sub 4}O{sub 9.163}

Oxygen potentials established by the equilibrium between three condensed phases, CaO{sub ss}+CoO{sub ss}+Ca{sub 3}Co{sub 2}O{sub 6} and CoO{sub ss}+Ca{sub 3}Co{sub 2}O{sub 6}+Ca{sub 3}Co{sub 3.93+α}O{sub 9.36−δ}, are measured as a function of temperature using solid-state electrochemical cells incorporating yttria-stabilized zirconia as the electrolyte and pure oxygen as the reference electrode. Cation non-stoichiometry and oxygen non-stoichiometry in Ca{sub 3}Co{sub 3.93+α}O{sub 9.36−δ} are determined using different techniques under defined conditions. Decomposition temperatures and thermodynamic properties of Ca{sub 3}Co{sub 2}O{sub 6} and Ca{sub 3}Co{sub 4}O{sub 9.163} are calculated from the results. The standard entropy and enthalpy of formation of Ca{sub 3}Co{sub 2}O{sub 6} at 298.15 K are evaluated. Using thermodynamic data from this study and auxiliary information from the literature, phase diagram for the ternary system Ca–Co–O is computed. Isothermal sections at representative temperatures are displayed to demonstrate the evolution of phase relations with temperature. - Graphical abstract: Isothermal section of the phase diagram of the system Ca–Co–O at 1250 K. - Highlights: • Improved definition of cation and oxygen nonstoichiometry of Ca{sub 3}Co{sub 3.93+α}O{sub 9.36−δ}. • Measurement of Δμ{sub O{sub 2}} associated with two 3-phase fields as a function of temperature. • Use of solid-state electrochemical cells for accurate measurement of Δμ{sub O{sub 2}}. • Decomposition temperatures and thermodynamic properties for ternary oxides. • Characterization of ternary phase diagram of the system Ca–Co–O.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Calendar-life versus cycle-life aging of lithium-ion cells with silicon-graphite composite electrodes

The use of blended silicon-graphite (Si-Gr) negative electrodes increases the energy density of lithium-ion cells over those containing only graphite (Gr) electrodes. However, volume changes in the Si particles that occur during cycling causes deterioration of the solid-electrolyte interphase (SEI) layer on the particles resulting in further electrolyte reduction that immobilizes Li+ ions and, therefore, capacity fade. Because the volume changes are not expected to occur during a potentiostatic hold (referred to as calendar-life aging), by comparison of cycle-life and calendar-life aged cells one can expect to assess the role of volume changes in the deterioration of cell performance. To this end, cells with Si-Gr and Gr negative electrodes (and Li 1.03 (Ni 0.5 Co 0.2 Mn 0.3 ) 0.97 O 2 containing positive electrodes) were assembled, tested, and compared using cycle-life and calendar-life aging protocols. As expected, the capacity loss of the cycle-life aged cells was higher than that of the calendar-life aged cells. However, the measurable capacity loss for the calendar-life aged cells indicated continued immobilization of Li + ions. Furthermore, electrolytes extracted from the calendar-life aged cells showed more LiPF 6 hydrolysis products than those extracted from the cycle-life aged cells. In conclusion, we discuss possible mechanistic causes for the observed aging behaviors in this article.

25 ENERGY STORAGE↗

A comprehensive review of metal-induced cellular transformation studies

In vitro transformation assays not only serve practical purposes in screening for potential carcinogenic substances in food, drug, and cosmetic industries, but more importantly, they provide a means of understanding the critical biological processes behind in vivo cancer development. In resemblance to cancer cells in vivo, successfully transformed cells display loss of contact inhibition, gain of anchorage independent growth, resistant to proper cell cycle regulation such as apoptosis, faster proliferation rate, potential for cellular invasion, and ability to form tumors in experimental animals. Cells purposely transformed using metal exposures enable researchers to examine molecular changes, dissect various stages of tumor formation, and ultimately elucidate metal induced cancer mode of action. For practical purposes, this review specifically focuses on studies incorporating As-, Cd-, Cr-, and Ni-induced cell transformation. Through investigating and comparing an extensive list of studies using various methods of metal-induced transformation, this review serves to bridge an information gap and provide a guide for avoiding procedural discrepancies as well as maximizing experimental efficiency. - Highlights: • In vitro transformation studies provide insights for metal-induced carcinogenesis. • Heavily individualized protocols may obscure scientific results and understandings. • This review may be used as reference for avoiding procedural discrepancies.

60 APPLIED LIFE SCIENCES↗

Li/SO2 Cell for Galileo

Some information on the special process controls for lithium sulfur dioxide (Li/SO2) batteries is presented with reference to how those controls affected the Galileo probe program and the instrument test vehicle program. The general considerations that go into any application for basically any type of battery system are discussed. Particular emphasis is given to some of the design tradeoffs which resulted because of the addition of the safety characteristics of the Li/SO2 system.

Blagdon, L. J.↗

Redistribution of annexin in gravistimulated pea plumules

We used immunocytochemistry to investigate the effects of gravistimulation on annexin localization in etiolated pea plumule shoots. In longitudinal sections, an asymmetric annexin immunostaining pattern was observed in a defined group of cells located just basipetal to apical meristems at the main shoot apex and at all of the axillary buds, an area classically referred to as the leaf gap. The pattern was observed using both protein-A-purified anti-annexin and affinity-purified anti-annexin antibodies for the immunostaining. A subset of the cells with the annexin staining also showed an unusually high level of periodic acid Schiff (PAS) staining in their cell walls. Prior to gravistimulation, the highest concentration of annexin was oriented toward the direction of gravity along the apical end of these immunostained cells. In contrast, both at 15 and 30 min after gravistimulation, the annexin immunostain became more evenly distributed all around the cell and more distinctly cell peripheral. The asymmetry along the lower wall of these cells was no longer evident. In accord with current models of annexin action, we interpret the results to indicate that annexin-mediated secretion in the leaf gap area is preferentially toward the apical meristem prior to gravistimulation, and that gravistimulation results in a redirection of this secretion. These data are to our knowledge the first to show a correlation between the vector of gravity and the distribution of annexins in the cells of flowering plants. c 2000 Editions scientifiques et medicales Elsevier SAS.

Non-NASA Center↗

Cellular alignment and fusion: Quantifying the effect of macrophages and fibroblasts on myoblast terminal differentiation

Highlights: • We present a method for cellular alignment calculation during routine cell culture. • Application revealed that macrophages promote myoblast alignment, but delay fusion. • Furthermore, fibroblasts regulate myoblast fusion, but not alignment. • Effect of macrophages on alignment is not altered by co-culture with fibroblasts. Successful skeletal muscle wound repair requires the alignment and fusion of myoblasts to generate multinucleated myofibers. In vitro, the accurate quantification of cellular alignment remains a challenge. Here we present the application of ImageJ and ct-FIRE to quantify muscle cell orientation by means of an alignment index (AI). Our optimised method, which does not require programming skills, allows the alignment of myoblasts in vitro to be determined independently of a predefined reference point. Using this method, we demonstrate that co-culture of myoblasts with macrophages, but not fibroblasts, promotes myoblast alignment in a cell density-dependent manner. Interestingly, myoblast fusion was significantly decreased in response to co-culture with macrophages, while the effect of fibroblasts on fusion was density-dependent. At lower numbers, fibroblasts significantly increased myoblast fusion, whereas at higher numbers a significant decrease was observed. Finally, triple co-culture revealed that the effect of macrophages on myoblast alignment and fusion is unaltered by the additional presence of fibroblasts. Application of our optimised method has therefore revealed quantitative differences in the roles of macrophages versus fibroblasts during alignment and fusion: while successful myoblast alignment is promoted by increasing macrophage numbers, regenerative fusion coincides with a decreasing macrophage population and initial rise in fibroblast numbers.

60 APPLIED LIFE SCIENCES↗

Biogas and Fuel Cells Workshop Summary Report: Proceedings from the Biogas and Fuel Cells Workshop

The National Renewable Energy Laboratory (NREL), in association with the U.S. Department of Energy’s Office of Energy Efficiency and Renewable Energy (EERE), held a Biogas and Fuel Cells Workshop on June 11–13, 2012, in Golden, Colorado, to discuss biogas and waste-to energy technologies for fuel cell applications. The meeting was spearheaded by the Fuel Cell Technologies Program in coordination with the Biomass Program. The overall objective was to identify opportunities for coupling renewable biomethane with highly efficient fuel cells to produce electricity; heat; combined heat and power (CHP); or combined heat, hydrogen and power (referred to as CHHP or “trigeneration”) for stationary or motive applications. The workshop focused on biogas sourced from wastewater treatment plants (WWTPs), landfills, and industrial facilities that generate or process large amounts of organic waste, including large biofuel production facilities (biorefineries).

08 HYDROGEN↗

In vitro sensitivity of granulo-monocytic progenitors as a new toxicological cell system and endpoint in the ACuteTox Project

The ACuteTox Project (part of the EU 6th Framework Programme) was started up in January 2005. The aim of this project is to develop a simple and robust in vitro strategy for prediction of human acute systemic toxicity, which could replace animal tests used for regulatory purposes. Our group is responsible for the characterization of the effect of the reference chemicals on the hematopoietic tissue. CFU-GM assay based on the culture of human mononuclear cord blood cells has been used to characterize the effects of the selected compounds on the myeloid progenitors. Previous results have shown the relevance of the CFU-GM assay for the prediction of human acute neutropenia after treatment of antitumoral compounds, and this assay has been recently approved by the ECVAM's Scientific Advisory Committee. Among the compounds included in the study there were pharmaceuticals, environmental pollutants and industrial chemicals. Eleven out of 55 chemicals did not show any cytotoxic effect at the maximum concentration tested. The correlation coefficients of CFU-GM IC50, IC70 and IC90 values with human LC50 values (50% lethal concentration calculated from time-related sublethal and lethal human blood concentrations) were 0.4965, 0.5106 and 0.5142 respectively. Although this correlation is not improve respect to classical in vitro basal cytotoxicity tests such as 3T3 Neutral Red Uptake, chemicals which deviate substantially in the correlation with these assays (colchicine, digoxin, 5-Fluorouracil and thallium sulfate) fitted very well in the linear regression analysis of the CFU-GM progenitors. The results shown in the present study indicate that the sensitivity of CFU-GM progenitors correlates better than the sensitivity of HL-60 cells with human LC50 values and could help to refine the predictability for human acute systemic toxicity when a given chemical may affect to the hematopoietic myeloid system.

60 APPLIED LIFE SCIENCES↗

Quasi-Steady-State Polarization Reveals the Interplay of Capacitive and Faradaic Processes in Capacitive Deionization

We employ slow cyclic voltammetry to study the quasi-steady-state capacitive deionization (CDI) of aerated 10 mM NaCl from V cell =-0.2 to 2 V. The method allows for the deconvolution of capacitive and faradaic processes, which are significant even at low voltage, in conjunction with pH, conductivity, dissolved oxygen (DO), and electrode potential measurements. The pH at three locations and effluent DO data identify asymmetric electrosorption in the cell configured with pristine activated carbon electrodes, where charge is irreversibly consumed to produce H + /OH - instead of reversibly adsorbing Cl - /Na + . Implementing a reference electrode resolves ion adsorption as a function of the individual potential at each electrode. Near-electrode pH probes reveal pH environments that diverge by up to 8 units during cell polarization and allow more accurate calculation of faradaic redox potentials in a flow-by CDI cell. In the aerated NaCl solution that will be relevant to industrial-scale water treatment, we find that DO reduction occurs to a greater degree than Na + adsorption at the cathode until DO removal becomes mass transfer limited at <-0.2 V vs. SHE. Two cell architectures – flow-by and flow-through – corroborate our findings. Finally, we reconcile all measurements to generate a map displaying how the potential is partitioned amongst the capacitive and faradaic processes occurring during CDI operation over a 2.2 V window.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗