Fourier spectrum of beams chopped by circular apertures.

The circular apertures in the case investigated are uniformly spaced. It is assumed that modulation does not alter beam collimation and that diffraction from aperture edges can be neglected. It is also assumed that the diameter of the apertures is equal to the spacing between the trailing edge and the leading edge of successive apertures. The motion of apertures across the beam is rectilinear. Calculations have been performed for both homogeneous and bivariate normal intensity distributions. The absolute values of the first six Fourier coefficients are plotted as a function of the beam radius normalized to aperture radius.

Cohen, S. C.↗

Straylight analysis of an aperture shade off-set from the SIRTF optical axis

Adoption of an aperture shade whose axis is offset from the optical axis of the SIRTF telescope has been proposed by Davis (1988). Moving the high side of the asymmetric (truncated) shade away from the optical axis can equalize the barrel baffle lengths illuminated by the aperture shade and reduce the dimensions of both the barrel baffle and aperture shade. The stray-light performance of this revised design is compared to that of the SIRTF baseline design, which uses a coaxial asymmetric aperture shade. Both designs incorporate a back focal distance of 100 cm and Davis's specifications for the primary and secondary cone baffles. Adoption of an offset aperture shade for SIRTF would slightly degrade its performance but would not violate any of the stray-light requirements. The SIRTF goal of natural-background-limited observations can be met with known blacks, Class 750 mirror contamination, and either aperture shade configuration.

Dinger, Ann St. Clair↗

The Information Content of Interferometric Synthetic Aperture Radar: Vegetation and Underlying Surface Topography

This paper first gives a heuristic description of the sensitivity of Interferometric Synthetic Aperture Radar to vertical vegetation distributions and underlying surface topography. A parameter estimation scenario is then described in which the Interferometric Synthetic Aperture Radar cross-correlation amplitude and phase are the observations from which vegetation and surface topographic parameters are estimated. It is shown that, even in the homogeneous-layer model of the vegetation, the number of parameters needed to describe the vegetation and underlying topography exceeds the number of Interferometric Synthetic Aperture Radar observations for single-baseline, single-frequency, single-incidence-angle, single-polarization Interferometric Synthetic Aperture Radar. Using ancillary ground-truth data to compensate for the underdetermination of the parameters, forest depths are estimated from the INSAR data. A recently-analyzed multibaseline data set is also discussed and the potential for stand-alone Interferometric Synthetic Aperture Radar parameter estimation is assessed. The potential of combining the information content of Interferometric Synthetic Aperture Radar with that of infrared/optical remote sensing data is briefly discussed.

Treuhaft, Robert N.↗

Aperture Shield Materials Characterized and Selected for Solar Dynamic Space Power System

The aperture shield in a solar dynamic space power system is necessary to prevent thermal damage to the heat receiver should the concentrated solar radiation be accidentally or intentionally focused outside of the heat receiver aperture opening and onto the aperture shield itself. Characterization of the optical and thermal properties of candidate aperture shield materials was needed to support the joint U.S./Russian solar dynamic space power effort for Mir. The specific objective of testing performed at the NASA Lewis Research Center was to identify a high-temperature material with a low specular reflectance, a low solar absorptance, and a high spectral emittance so that during an off-pointing event, the amount of solar energy reflecting off the aperture shield would be small, the ratio of solar absorptance to spectral emittance would provide the lowest possible equilibrium temperature, and the integrity of the aperture shield would remain intact.

Source record↗

Zernike-like Orthogonal Basis Functions for Wavefront Characterization over Sampled, Irregular Apertures

For optical systems with circular apertures, wavefronts are often analyzed using Zernike polynomials, and individual Zernike functions are associated with familiar optical aberrations. For systems with noncircular apertures, or in practical situations in which wavefronts are measured at a limited number of points in the aperture, the Zernike polynomials are no longer an orthogonal basis for the measured data. Although there are an endless number of ways to create a basis for such measured data, a "Zernike-like" basis is useful to connect with our experience with the usual optical aberrations. In this paper, the steps required to identify a Zernike-like basis for wavefronts over sampled, irregular apertures are presented, based on the Gram-Schmidt orthogonalization technique. The benefits of analyzing optical wavefronts using an orthogonal basis specific to an optical system's aperture shape and wavefront sampling, instead of using the traditional Zernike polynomials, are detailed in two examples, from image-based wavefront sensing on a segmented-aperture telescope (the James Webb Space Telescope Testbed Telescope at Ball Aerospace) and from interferometer characterization for surface metrology of a hexagonal mirror segment.

Aronstein, David L.↗

Fresnel Lenses for Wide-Aperture Optical Receivers

Wide-aperture receivers for freespace optical communication systems would utilize Fresnel lenses instead of conventional telescope lenses, according to a proposal. Fresnel lenses weigh and cost much less than conventional lenses having equal aperture widths. Plastic Fresnel lenses are commercially available in diameters up to 5 m large enough to satisfy requirements for aperture widths of the order of meters for collecting sufficient light in typical long-distance free-space optical communication systems. Fresnel lenses are not yet suitable for high-quality diffraction-limited imaging, especially in polychromatic light. However, optical communication systems utilize monochromatic light, and there is no requirement for high-quality imaging; instead, the basic requirement for an optical receiver is to collect the incoming monochromatic light over a wide aperture and concentrate the light onto a photodetector. Because of lens aberrations and diffraction, the light passing through any lens is focused to a blur circle rather than to a point. Calculations for some representative cases of wide-aperture non-diffraction-limited Fresnel lenses have shown that it should be possible to attain blur-circle diameters of less than 2 mm. Preferably, the blur-circle diameter should match the width of the photodetector. For most high-bandwidth communication applications, the required photodetector diameters would be about 1 mm. In a less-preferable case in which the blur circle was wider than a single photodetector, it would be possible to occupy the blur circle with an array of photodetectors. As an alternative to using a single large Fresnel lens, one could use an array of somewhat smaller lenses to synthesize the equivalent aperture area. Such a configuration might be preferable in a case in which a single Fresnel lens of the requisite large size would be impractical to manufacture, and the blur circle could not be made small enough. For example one could construct a square array of four 5-m-diameter Fresnel lenses to obtain the same light-collecting area as that of a single 10-m-diameter lens. In that case (see figure), the light collected by each Fresnel lens could be collimated, the collimated beams from the four Fresnel lenses could be reflected onto a common offaxis paraboloidal reflector, and the paraboloidal reflector would focus the four beams onto a single photodetector. Alternatively, detected signal from each detector behind each lens would be digitized before summing the signals.

Hemmati, Hamid↗

A Spherical Active Coded Aperture for 4π Gamma-ray Imaging

Gamma-ray imaging facilitates the efficient detection, characterization, and localization of compact radioactive sources in cluttered environments. Fieldable detector systems employing active planar coded apertures have demonstrated broad energy sensitivity via both coded aperture and Compton imaging modalities. But, planar configurations suffer from a limited field-of-view, especially in the coded aperture mode. In order to improve upon this limitation, we introduce a novel design by rearranging the detectors into an active coded spherical configuration, resulting in a 4pi isotropic field-of-view for both coded aperture and Compton imaging. This work focuses on the low- energy coded aperture modality and the optimization techniques used to determine the optimal number and configuration of 1 cm 3 CdZnTe coplanar grid detectors on a 14 cm diameter sphere with 192 available detector locations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Aperture size distribution, length, and preferential location of bed-parallel veins in shale

Bed-parallel, calcite-filled veins (BPVs) are common in shale formations, and although they have been widely described in other studies, little is known about their population aperture size distribution. To address this knowledge gap, we analyzed BPV sizes in outcrops and cores from the Vaca Muerta Formation, Neuquén Basin, Argentina; in two cores from the Marcellus Formation, Appalachian Basin, northeast Pennsylvania; and in one core from the Wolfcamp Shale, Delaware Basin, West Texas. Nine out of ten aperture size populations follow a negative exponential distribution, with one following a weak power law. Bed-parallel vein size distribution and intensity vary among formations and within the same shale. We define three groups of distributions: (1) Vaca Muerta outcrops, with the highest BPV intensity and the largest BPVs (cumulative frequency of 4.9 BPVs per meter [BPVs/m] for apertures 0.265 mm to 8.7 cm); (2) Vaca Muerta cores with a similar BPV intensity overall but with no apertures wider than 1.2 cm; and (3) Vaca Muerta, Wolfcamp, and Marcellus cores with the fewest BPVs (cumulative frequency up to 0.63 BPVs/m) and very few wider than 1 cm. Aperture and length in two outcrop data sets are weakly positively correlated and follow power laws with exponents of 0.44 and 0.49. Mechanical interfaces at boundaries between different lithologies exert a strong control on BPV location, with 65–75% of observed interfaces having BPVs along them. Only 25–30% of the BPVs occur at observed material interfaces, however, and unless subtle, unobserved mechanical layering is present, other factors must also control location. BPV intensity and organic richness (TOC) from Vaca Muerta well logs are correlated in some instances but not in others, indicating TOC is not always a good proxy for BPV location or intensity. Furthermore, these findings provide useful information for modeling of hydraulic fracture treatments where BPVs may influence development of the stimulated fracture network, for example by limiting height growth.

58 GEOSCIENCES↗

SU-E-T-187: Collimation Methods in Spot Scanning Proton Therapy: A Treatment Plan Comparison Between a Fixed Aperture and a Dynamic Collimation System

Purpose: Low-energy treatments during spot scanning proton therapy (SSPT) suffer from poor conformity due to increased spot size. Collimation devices can reduce the lateral penumbra of a proton therapy dose distribution and improve the overall plan quality. The purpose of this work was to study the advantages of individual energy-layer collimation, which is unique to a recently proposed Dynamic Collimation System (DCS), in comparison to a standard, fixed aperture that allows only a single shape for all energy layers. Methods: Three brain patients previously planned and treated with SSPT were re-planned using an in-house treatment planning system capable of modeling collimated and un-collimated proton beamlets. The un-collimated plans, which served as a baseline for comparison, reproduced the target coverage of the clinically delivered plans. The collimator opening for the aperture based plans included a 0.6 cm expansion of the largest cross section of the target in the Beam’s Eye View, while the DCS based plans were created by optimizing the collimator position for beam spots near the periphery of the target in each energy layer. Results: The reduction of mean dose to normal tissue adjacent to the target, as defined by a 10 mm ring, averaged 9.13% and 3.48% for the DCS and aperture plans, respectively. The conformity index, as defined by the ratio of the volume of the 50% isodose line to the target volume, yielded an average improvement of 16.42% and 8.16% for the DCS and aperture plans, respectively. Conclusion: Collimation reduces the dose to normal tissue adjacent to the target and increases dose conformity to the target region for low-energy SSPT. The ability of the DCS to provide collimation to each energy layer yields better conformity in comparison to fixed aperture plans. This work was partially funded by IBA (Ion Beam Applications S.A.)

60 APPLIED LIFE SCIENCES↗

Technical Note: A treatment plan comparison between dynamic collimation and a fixed aperture during spot scanning proton therapy for brain treatment

Purpose: To quantitatively assess the advantages of energy-layer specific dynamic collimation system (DCS) versus a per-field fixed aperture for spot scanning proton therapy (SSPT). Methods: Five brain cancer patients previously planned and treated with SSPT were replanned using an in-house treatment planning system capable of modeling collimated and uncollimated proton beamlets. The uncollimated plans, which served as a baseline for comparison, reproduced the target coverage and organ-at-risk sparing of the clinically delivered plans. The collimator opening for the fixed aperture-based plans was determined from the combined cross sections of the target in the beam’s eye view over all energy layers which included an additional margin equivalent to the maximum beamlet displacement for the respective energy of that energy layer. The DCS-based plans were created by selecting appropriate collimator positions for each row of beam spots during a Raster-style scanning pattern which were optimized to maximize the dose contributions to the target and limited the dose delivered to adjacent normal tissue. Results: The reduction of mean dose to normal tissue adjacent to the target, as defined by a 10 mm ring surrounding the target, averaged 13.65% (range: 11.8%–16.9%) and 5.18% (2.9%–7.1%) for the DCS and fixed aperture plans, respectively. The conformity index, as defined by the ratio of the volume of the 50% isodose line to the target volume, yielded an average improvement of 21.35% (19.4%–22.6%) and 8.38% (4.7%–12.0%) for the DCS and fixed aperture plans, respectively. Conclusions: The ability of the DCS to provide collimation to each energy layer yielded better conformity in comparison to fixed aperture plans.

60 APPLIED LIFE SCIENCES↗

Deterministic direct aperture optimization using multiphase piecewise constant segmentation

Purpose Direct aperture optimization (DAO) attempts to incorporate machine constraints in the inverse optimization to eliminate the post‐processing steps in fluence map optimization (FMO) that degrade plan quality. Current commercial DAO methods utilize a stochastic or greedy approach to search a small aperture solution space. In this study, we propose a novel deterministic direct aperture optimization that integrates the segmentation of fluence map in the optimization problem using the multiphase piecewise constant Mumford‐Shah formulation. Methods The Mumford‐Shah based direct aperture optimization problem was formulated to include an L2‐norm dose fidelity term to penalize differences between the projected dose and the prescribed dose, an anisotropic total variation term to promote piecewise continuity in the fluence maps, and the multiphase piecewise constant Mumford‐Shah function to partition the fluence into pairwise discrete segments. A proximal‐class, first‐order primal‐dual solver was implemented to solve the large scale optimization problem, and an alternating module strategy was implemented to update fluence and delivery segments. Three patients of varying complexity—one glioblastoma multiforme (GBM) patient, one lung (LNG) patient, and one bilateral head and neck (H&N) patient with 3 PTVs—were selected to test the new DAO method. For each patient, 20 non‐coplanar beams were first selected using column generation, followed by the Mumford‐Shah based DAO (DAO MS ). For comparison, a popular and successful approach to DAO known as simulated annealing—a stochastic approach—was replicated. The simulated annealing DAO (DAO SA ) plans were then created using the same beam angles and maximum number of segments per beam. PTV coverage, PTV homogeneity , and OAR sparing were assessed for each plan. In addition, high dose spillage, defined as the 50% isodose volume divided by the tumor volume, as well as conformity, defined as the van't Riet conformation number, were evaluated. Results DAO MS achieved essentially the same OAR doses compared with the DAO SA plans for the GBM case. The average difference of OAR D max and D mean between the two plans were within 0.05% of the plan prescription dose. The lung case showed slightly improved critical structure sparing using the DAO MS approach, where the average OAR D max and D mean were reduced by 3.67% and 1.08%, respectively, of the prescription dose. The DAO MS plan substantially improved OAR dose sparing for the H&N patient, where the average OAR D max and D mean were reduced by over 10% of the prescription dose. The DAO MS and DAO SA plans were comparable for the GBM and LNG PTV coverage, while the DAO MS plan substantially improved the H&N PTV coverage, increasing D99 by 6.98% of the prescription dose. For the GBM and LNG patients, the DAO MS and DAO SA plans had comparable high dose spillage but slightly worse conformity with the DAO MS approach. For the H&N plan, DAO MS was considerably superior in high dose spillage and conformity to the DAO SA . The deterministic approach is able to solve the DAO problem substantially faster than the simulated annealing approach, with a 9.5‐ to 40‐fold decrease in total solve time, depending on the patient case. Conclusions A novel deterministic direct aperture optimization formulation was developed and evaluated. It combines fluence map optimization and the multiphase piecewise constant Mumford‐Shah segmentation into a unified framework, and the resulting optimization problem can be solved efficiently. Compared to the widely and commercially used simulated annealing DAO approach, it showed comparable dosimetry behavior for simple plans, and substantially improved OAR sparing, PTV coverage, PTV homogeneity, high dose spillage, and conformity for the more complex head and neck plan.

Nguyen, Dan↗

Customizable Aperture Geometry in Metal–Organic Frameworks for Kinetic Hydrocarbon Separation

Precise control of aperture dimensions is crucial in adsorptive separations of hydrocarbons, as it directly affects key parameters such as selectivity, capacity, diffusion, and recyclability. The development of metal–organic frameworks (MOFs) has enabled the fine-tuning of local pore environments to address important hydrocarbon separations. However, customizing the aperture geometry to tune the kinetic separation performance remains challenging. Here, we deploy a mixed-linker synthesis strategy, combining long and short linkers on fcu net Zr-MOFs with equilateral triangular apertures to construct isoreticular multivariate MOFs, NU-415 and NU-416, with tailored isosceles triangular apertures suitable for the separation of hexane isomers. Sorption, liquid batch separation, and X-ray diffraction measurements demonstrate significantly improved selectivity, capacity, stability, and recyclability of NU-415 and NU-416 compared with Zr-muconate and MOF-801. Notably, both NU-415 and NU-416 achieve uptake capacities of 2.2 mmol g –1 in 1 min with an n-hexane to 2,2-dimethylbutane selectivity over 200 in an equimolar ternary mixture at ambient conditions, comparable to leading reported materials. Mechanistic studies confirm that separation performance is predominantly governed by significant kinetic differences rather than by thermodynamics. Furthermore, the successful customization of aperture geometry not only enables superior linear to monobranched hexane selectivity in NU-415 but also demonstrates the mixed-linker synthesis strategy as a promising solution for precise and predictable pore architecture control in MOFs.

Adsorption↗

Elliptic Aperture CCT Coils for HTS Dipole Magnets

High-temperature REBa$_{2}$Cu$_{3}$O$_{7-x}$ (REBCO) superconductors are a route to increase the field of accelerator magnets beyond the 15-16T practical limit of Nb$_{3}$Sn. REBCO cabled in a CORC geometry is a promising fit for this application, enabling the design of low inductance magnets with conductor transposition. However, the use of CORC in coils with the tight conductor bending radii typical of accelerator magnets remains a key challenge, with on-going research both on the conductor development and coil design fronts seeking to address this issue. Here, in this work we explore the tradeoffs between circular and elliptic aperture canted-cosine-theta (CCT) coils when the conductor minimum bending radius is a key consideration, concluding that aperture ellipticity is an important free parameter in the optimization of magnetically efficient CORC dipole magnets. In particular, we show that elliptic bore designs enable a regime of smaller aperture HTS coils, an important result for LTS-HTS hybrid magnets and more generally for accelerator applications benefiting from non-circular magnet apertures. To this end we present an elliptic aperture dipole design optimized for hybrid testing within the US Magnet Development Program (US-MDP) and share 77 K test results of a prototype coil which provides first experimental confirmation of the advantages.

Brouwer, L. [Lawrence Berkeley National Laboratory↗

Synthesis of offset dual reflector antennas transforming a given feed illumination pattern into a specified aperture distribution

The problem of transforming a given primary feed pattern into a desired aperture field distribution through two reflections by an offset dual reflector system is investigated using the concepts of geometrical optics. A numerically rigorous solution for the reflector surfaces is developed which realizes an exact aperture phase distribution and an aperture amplitude distribution that is accurate to within an arbitrarily small numerical tolerance. However, this procedure does not always yield a smooth solution, i.e., the reflector surfaces thus realized may not be continuous or their slopes may vary too rapidly. In the event of nonexistence of a numerically rigorous smooth solution, an approximate solution that enforces the smoothness of the reflector surfaces can be obtained. In the approximate solution, only the requirement for the aperture amplitude distribution is relaxed, and the condition on the aperture phase distribution is continued to be satisfied exactly.

Mittra, R.↗

A novel method of calculating far-field patterns of large aperture antennas

A method is described for calculation of the radiation pattern of large aperture antennas. A piece-wise linear approximation of the aperture field using overlapping pyramidal basis functions allows the radiation pattern of an aperture antenna to be calculated as though it were a two-dimensional array. The calculation of radiation pattern data versus theta and phi, suitable for 3-D or contour plot algorithms, is achieved by locating the array in the yz-plane and performing a summation over the aperture field data sampled on a square grid. A FORTRAN subroutine is provided for performing radiation pattern calculations. Numerical results are included to demonstrate the accuracy and convergence of the method. These numerical results indicate that typical accuracies of + or - 0.1 dB for Directivity, + or - dB for the 1st Sidelobe Level, and + - 2dB for the 2nd Sidelobe Level can be obtained with an aperture grid of 45x45 points and requires approximately 0.02 seconds CPU time per far-field data point on a VAX 11/750 with a floating point accelerator.

Bailey, M. C.↗

Jacobi-Bessel Analysis Of Antennas With Elliptical Apertures.

Coordinate transformation improves convergence pattern analysis of elliptical-aperture antennas. Modified version of Jacobi-Bessel expansion for vector diffraction analysis of reflector antennas uses coordinate transformation to improve convergence with elliptical apertures. Expansion converges rapidly for antennas with circular apertures, but less rapidly for elliptical apertures. Difference in convergence behavior between circular and elliptical Jacobi-Bessel algorithms indicated by highest values of indices m, n, and p required to achieve same accuracy in computed radiation pattern of offset paraboloidal antenna with elliptical aperture.

Rahmat-Samii, Y.↗

CWG: A FORTRAN program for mutual coupling in a planar array of circular waveguide-fed apertures

A FORTRAN program which calculates the mutual coupling between circular apertures in a conductive plane is documented. The program is quite general in that the apertures do not have to be the same sizes, nor do they have to be polarized in the same direction. In addition, several waveguide modes (TE and/or TM) may be specified in the apertures and the mutual coupling between all combinations of apertures and modes will be calculated. The program also allows multiple layers of homogeneous dielectrics to be placed over the aperture array. Outside the layered region, one can specify either a homogeneous half-space, or a perfect reflecting surface.

Bailey, M. C.↗

Synthetic Aperture Interferometric Radiometer (SAIR)

The aperture size requirements of imaging microwave radiometers in geosynchronous orbit ruled out filled aperture antenna systems below 10 GHz. In the regions 10 to 30 GHz, filled apertures are only marginally practical. The size requirements in turn aggravate the problems with a mechanically steered antenna beam. Both the aperture size and steering problems are resolved with a synthetic aperture interferometric radiometer (SAIR). The SAIR imaging is discussed, along with the requirements of the two-dimensional antenna elements.

Ruf, C. S.↗