Optimizing the Operational Parameters of an Electrochemical Purification Cell for Corrosion Mitigation in CSP Plants During Operation: Preprint

To make concentrating solar power (CSP) cost-competitive, the next generation of CSP plants will increase efficiency by operating at a higher temperature, which will require a new thermal energy storage material. One option for the thermal energy storage material is a ternary chloride salt that is stable at the temperatures required, but reacts easily with the atmosphere to form MgOHCl, a corrosive impurity. If left unchecked, this impurity will corrode the containment alloys, potentially leading to dangerous spills. We are working to design an electrochemical purification cell to remove MgOHCl from the molten chloride salt during CSP plant operation. In this paper, we use predictive modeling to assess the rate at which purification must occur. Additionally, we analyze possible process flow pathways for the molten chloride salts. Ultimately, we determine that implementation of a single reactor through which all chloride salts flow is the most efficient design to reduce impurity concentration below 0.1 mol % impurity.

concentrating solar power↗

Formation of carbon and oxygen rich surface layer on high purity magnesium by atmospheric carbon dioxide plasma

Carbon and oxygen-rich corrosion barrier layer formed on Mg by a simple and scalable CO 2 atmospheric plasma (CO 2 -AP) process. The reactive CO 2 -AP interacts with the Mg surface and forms a unique layered structure with the top MgCO 3 /MgO-intermixed particulates pillars and the bottom dense layer. The surface features were simultaneously formed on the nano-/micro-structured MgO layer by carbonate molecules, plasma-active CO 2 molecules, and/or other volatile organic compounds on the nano-/micro-structured MgO particle layer. The resulting surfaces after CO 2 -AP were either hydrophobic or hydrophilic and exhibited lower anodic current or high resistance for Mg corrosion. For the hydrophobic surfaces of CO 2 -AP treated Mg, molecular dynamic simulations were performed to understand the origin of hydrophobicity and identified that the amorphous carbon layers formed on the Mg surface are the source. The environmentally benign abundant-gas-based process enables the cost reduction associated with waste treatment, generation of by-product, and supply of raw material.

36 MATERIALS SCIENCE↗

One piece ceramic heat exchanger for concentrating solar power electric plants

Using additive manufacturing techniques, a ceramic heat exchanger was optimized for a concentrating solar power (CSP) electric power plant with a corrosive molten salt at atmospheric pressure as the solar field heat transfer fluid and supercritical carbon dioxide at 200 bar as the power block fluid. Temperatures ranged from 750 °C to 540 °C. The plant heat exchanger was optimized for heat transfer and stress using 1 m³ modules arranged in parallel. Heat transfer was optimized using COMSOL Multiphysics software resulting in a unique semi-elliptical cross section for the fluid flow channels in a counter-flow configuration. Counter-flow was made possible through additive manufacturing of the fluid headers as part of each modular heat exchanger thus producing the entire module as a single piece and minimizing cost. Using reasonable parametric values, a heat exchanger module was optimized to 0.5 MW/m³, and a section of it was manufactured including the fluid headers. Here, parametric studies showed the potential for a module to reach 3.5 MW/m³.

14 SOLAR ENERGY↗

Corrosion of Chromia-Forming and Alumina-Forming Ferritic Stainless Steels under Dual Atmosphere Exposure Conditions

The surface morphology and chemistry of oxide scales formed on select chromia-forming and alumina-forming ferritic steels have been studied after exposure to a dual atmosphere of hydrogen and air. Localized Fe-rich oxide nodules with surface whiskers/platelets form at the onset of corrosion. The initiation and growth of localized nodules and breakdown of passivation are attributed to the presence of hydrogen, inclusion of iron oxide in the passivating scale, and subsequent growth of iron-rich oxide due to the establishment of redox (H 2 -H 2 O) atmosphere and modification of oxide defect chemistry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electrochemical Mitigation of Corrosion in Concentrated Solar Power Systems

To make concentrating solar power (CSP) cost-competitive, the next generation of CSP plants will increase efficiency by operating at a higher temperature, which will require a new thermal energy storage material. One option for the thermal energy storage material is a ternary chloride salt that is stable at the temperatures required, but reacts easily with the atmosphere to form MgOHCl, a corrosive impurity. If left unchecked, this impurity will corrode the containment alloys, potentially leading to dangerous spills. We are working to design an electrochemical purification cell to remove MgOHCl from the molten chloride salt during CSP plant operation.

chloride salts↗

Laboratory Accelerated Cyclic Corrosion Testing and On-Road Corrosion Testing of AA6××× Coupled to Carbon Fiber-Reinforced Plastics

Structures made from a combination of aluminum alloy (AA) and carbon fiber-reinforced plastic (CFRP) are susceptible to galvanic corrosion of the AA in harsh atmospheric conditions, such as might exist for closure panels in automotive applications. It is important to understand the galvanic corrosion behavior of these materials under laboratory conditions as that might allow prediction of performance in real environments. This work tested specially designed AA6×××-CFRP coupons, including AA6111 and AA6022, connected to CFRP made from two different carbon fiber fabrics (twill and random) with the aim of understanding the corrosion behaviors in a laboratory cyclic exposure chamber and during on-road exposure. The extent of corrosion was assessed by galvanic current measurements, optical profilometry, cross-sectional area analysis, and microscopic analysis. Based on the results, it was determined that the corrosion susceptibilities and morphologies observed in CFRP/AA couples tested in an environmental chamber for 12 weeks were in correspondence with those of the coupons subjected to on-road testing for 1 y in Columbus, OH.

Materials Science↗

Autonomous Infrared and Small (Wide) Angle X-Ray Scattering (IR-S(W)AXS) Capability

Thin water films are 2-D, nanoconfined layers that form on solid surfaces exposed to humid atmospheres—environments ubiquitous across catalysis, corrosion science, soil science, and subsurface geochemistry. At relative humidity (RH) values below saturation, these films are Å–nm thick and exhibit properties that differ sharply from bulk water, including disrupted H-bonding and impeded mass transport. Owing to their high surface-to-volume ratio, dissolution of the solid can rapidly drive strong supersaturation with respect to secondary phases. Reactivity in thin water films is highly sensitive to film thickness, and critically, thickness evolves during reaction because the hygroscopicity of the interfacial system changes as ions accumulate or diminish in the film and as reaction products transform. To accurately probe and control these dynamics, a capability is needed that can measure and automatically maintain a constant water-film thickness while simultaneously monitoring solid dissolution, nucleation, and growth. This project developed an autonomous Infrared/Small Angle X-ray Scattering-Wide Angle X-ray Scattering (IR/(W)SAXS) for investigating reactivity in thin water films on solid surfaces exposed to humidified gases. The capability consists of an IR spectrometer, a (W)SAXS instrument, and a mass flow controller system for generating variably humidified gas flows to a custom reaction cell. Progress on each of the major components of the capability are detailed below.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

In Situ Transmission Electron Microscopy of High-Temperature Inconel-625 Corrosion by Molten Chloride Salts

This paper describes an approach to monitor high temperature molten chloride (MgCl 2 -NaCl-KCl) salt corrosion of Inconel-625 alloy in real time at high spatial resolution. The approach is based on a micro-environmental-cell assembly integrated into a transmission-electron-microscope goniometer to examine in situ the salt-alloy interface during corrosion, employing real time electron diffraction and imaging. It establishes procedures to minimize incorporation of H 2 O or O 2 from atmosphere in the chloride salts during sample fabrication and corrosion, which is critical to understanding the fundamental corrosion mechanisms. A clustering algorithm and a 2D Gaussian fit function are used to determine diffraction spot intensities in in situ diffraction patterns, to quantify alloy corrosion. This facilitates quantitative observation of the evolution of individual grains, in contrast to conventional macroscopic corrosion rate quantification. The isothermal corrosion rate of Inconel-625 in an anhydrous, unoxidized salt-stack is 220 ± 30 μm year -1 at 700 °C and 350 ± 20 μm year -1 at 800 °C. However, the corrosion rate at 700 °C increases five-fold to 1000 ± 170 μm year -1 when the salt stack is air-exposed, indicating the dominant effects of hydrated or oxidized impurities on corrosion acceleration. Furthermore, real time imaging of the microstructure evolution suggests that corrosion is initiated at grain boundaries.

14 SOLAR ENERGY↗

Elucidating the corrosion mechanism of commercial Ni-based Superalloys in UCl3 containing-chloride Molten Salt Systems

Molten salt reactors (MSRs) have gained renewed interest, providing several advantages over their predecessors, including the capability to consume spent fuels, enhancing the environmental sustainability of the uranium fuel cycle. For example, molten chloride fast reactors (MCFRs) can reach criticality with molten chloride spent fuel containing high concentrations of impurities, such as actinide products like uranium chloride (UCl3). However, the redox potential of chloride molten salt fuels may change in the presence of these impurities, dictating their corrosivity and in turn the corrosion performance of structural components, such as those constructed from nickel (Ni)-based alloys. The purpose of this investigation is to assess the extent of corrosion of Ni-based alloy, Inconel 617, when exposed to UCl3-LiCl-KCl eutectic salt. Inconel 617 one of only six structural materials that are fully qualified by the American Society for Mechanical Engineers (ASME) Boiler and Pressure Vessel Code for high-temperature nuclear reactor components, making it a technologically mature material to consider for constructing MCFRs. Inconel 617 specimens were submerged in a static LiCl-KCl-UCl3 eutectic salt mixture heated at 700 C for 1000 h under an inert atmosphere. Upon completion, the extent of corrosion was analyzed through a multi-modal characterization approach spanning the engineering to nanoscale, employing computed tomography, focused-ion beam, and transmission electron microscopy techniques. Results from this investigation will enhance our understanding of property-to-performance relationships of candidate structural materials for MSRs with respect to corrosion resistance and interactions between the salt and alloy interface.

36 MATERIALS SCIENCE↗

Comprehensive insights into competitive oxidation/sulfidation reactions on binary ferritic alloys at high temperatures

Interpreting high-temperature corrosion induced by mixed-gas atmospheres is challenging due to the different contributions of oxidizing gases. In this work, a comprehensive study on the combined oxidation/sulfidation using label molecules is presented. Fe-Cr model alloys with 2 wt% and 9 wt% Cr were isothermally exposed using a volumetric mixture of 0.5%S 16 O 2 /27%H 2 18 O and 0.5%S 16 O 2 /7%H 2 18 O at 650 °C for 5 h and then characterized by secondary ion mass spectroscopy (SIMS). Additionally, the reactions were followed in-situ utilizing energy dispersive X-ray diffraction. The study showed that both S 16 O 2 and H 2 18 O contribute to the oxidation of the alloys but to different extents depending on the Cr-content.

36 MATERIALS SCIENCE↗

FY2022 Status Report: Cold Spray for Canister SCC Mitigation and Repair

This progress report describes work performed during FY22 at Sandia National Laboratories (SNL) to assess the corrosion performance of cold spray coatings to enable optimization of cold spray for the purposes of mitigation and/or repair of potentially susceptible regions, corrosion, or stress corrosion cracking (SCC) in austenitic stainless steel for spent nuclear fuel (SNF) storage. Of particular concern is SCC, by which a through-wall crack could potentially form in a canister outer wall over time intervals that may be shorter than possible dry storage times. In FY21, initial corrosion explorations of cold spray coating were evaluated and in FY22, an expanded set of cold spray coatings with in-depth analysis of post-exposure accelerated testing was explored. Additionally, relevant atmospheric exposure testing was carried out and initial results are presented herein. The corrosion attack from the accelerated testing and more realistic atmospheric exposures environments were compared to identify potentially deleterious factors for corrosion as well as help to understand the applicability of accelerated testing for cold spray optimization. This initial analysis will help to enable optimization of the corrosion resistance cold spray, one of the more promising coating and repair techniques, for potential application in an SNF environment. Learnings from both are summarized, and implications and future work are presented in this report.

36 MATERIALS SCIENCE↗

The Long-term Storage of ILW: Building Stores with the Appropriate Environmental Controls - 20294

In the UK, containers for the storage and disposal of intermediate level radioactive waste (ILW) typically use stainless steel due to its excellent mechanical properties and corrosion resistance. The period of interim storage before a disposal facility is available, however, is longer than available engineering experience with stainless steels in relevant environmental conditions. Additionally, after disposal the ability of ILW containers to withstand further periods of exposure to the environment is expected to provide substantial benefits to the operation of a disposal facility and the safety case underpinning its closure. For these reasons, although there have been no instances of failure of stainless steels in indoor storage conditions, a focused R and D programme has been carried out to identify the environmental envelope over which the material does not significantly degrade. In this study we summarise experimental and modelling studies carried out over the last decade to build a solid mechanistic understanding of the corrosion behaviour of stainless steels in indoor atmospheric conditions. We then identify suitable environmental regimes to minimise the risk of degradation processes and explore approaches to monitoring the storage conditions to gain confidence in the long-term performance of the system. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Mitigation of Molten Salt Corrosion

The desire to increase the peak operational temperature of Concentrated Solar Power (CSP) plants to lower the levelized cost of CSP-derived electricity, has led to consideration of an earth-abundant, low-cost, thermally-stable, molten MgCl 2 -KCl-NaCl (40-40-20 mole%) salt for high-temperature thermal energy storage and heat transfer. The reliable, long-term containment of such a molten salt is challenging, however, due to the corrosion of cost-effective, high-temperature structural metal alloys in this salt (particularly if this salt is contaminated with oxygen-bearing species). This project has been focused on: i) development of equipment for evaluating corrosion kinetics in molten chlorides under well-controlled thermal, fluid dynamic, and atmospheric conditions at CSP-relevant temperatures, ii) use of such equipment to evaluate the influence of forced convection on corrosion kinetics (to determine the role of liquid phase diffusion on such corrosion), and iii) identifying a corrosion-mitigation strategy that can be industrially applied to achieve a projected annual corrosion ≤30 μm at CSP-relevant temperatures. The overall goals of this project have been: i) to understand the rate-limiting step(s) and associated kinetic laws governing corrosion in molten chlorides at 750°C, ii) to determine key operational parameters affecting the corrosion kinetics in molten salts, and iii) to demonstrate the tailoring of such parameters to appreciably reduce such corrosion.

14 SOLAR ENERGY↗

An Innovative Zero-Liquid Discharge Intermediate-Cold-Liquid Eutectic-Freeze Desalination System

A novel freeze desalination technology is presented for purification of water produced from various industrial processes, including oil and gas extraction. The main innovative idea is introducing a water-immiscible intermediate-cold-liquid (ICL) medium which absorbs the cold from a refrigeration cycle and transfers it to a freezing chamber where it is mixed with brine. The cold ICL enters the freezing chamber at temperatures between -10°C to -30°C. Precooled brine in injected into the freezing chamber and pure water freezes out of the brine upon mixing with the ICL. The rate of freezing inside the chamber is controlled by adjusting the flow rate of the cold ICL relative to the inlet brine. Both eutectic freeze and non-eutectic freezing are possible by controlling the temperature of the freezing chamber. The solid-liquid slurry created in the freezing chamber flows to a filter separation unit after passing through a separation column. The ice crystals are separated from the liquid by a rotary filter device. The collected ice is rinsed by a centrifugal unit. The rinsed ice is melted to produce fresh water. The developed technology resolves the issues common to current freeze-desalination systems while offering superior heat transfer performance ascribed to direct-contact between the cooling medium and the brine in addition to producing solid salt and pure water. The system operates under atmospheric pressure. The low operation temperature minimizes the corrosion issues common in systems exposed to brine. Also, due to the low operating temperature, there are no concerns about evaporation of volatile organics from the produced water during the treatment. The developed technology effectively eliminates the use of chemicals for pretreatment of brine. The system can be constructed from commercially available components. Extensive testing using a lab-scale prototype by using synthetic brine and actual produced water with TDS values from 50,000 ppm to 300,000 ppm showed that freshwater could be achieved with relatively small dependency on the quality of the input brine. The quality of the treated water was found to be mainly a function of the duration of the centrifugal process. Treated water with TDS as low as 200 ppm could be achieved in the tests. Thermo-economic modeling coupled with system level thermochemical process model were developed for prediction of the LCOW. The LCOW was predicted to be $\$$0.50 to $\$$0.90 per barrel of produced water. The potential markets for deployment of the technology are the oil and gas, in-land thermoelectric powerplants, RO desalination plants, and mining industry.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Modeling Marangoni Convection using a Velocity-Time Relationship

The Waste Treatment and Immobilization Plant (WTP) at the U.S. Department of Energy’s (DOE’s) Handford site is designed to treat 56 million gallons of radioactive waste through vitrification. The melting vessels physical and chemical integrity is essential to maintain, as failure has a high safety and financial penalty. Monofrax® K-3 refractory, the material widely used for the melting vessel, undergoes significant corrosion over time, concentrated at the triple-point junction between the gaseous atmosphere, refractory, and glass melt, producing a characteristic neck-like profile that significantly limits refractory service life. Accurate prediction of the corrosion within the melter can be used to prevent this and extend the lifetime of the melters. A computational fluid dynamics (CFD) model was previously developed, and predicted subsurface refractory corrosion, but failed to predict the neck-line profile observed experimentally. To address this limitation, the glass-melt meniscus geometry at the glass-refractory interface was estimated from experimentally measured neck profiles and wettability experiments. A curve was fitted to the neck profile to identify the triple point location, and the meniscus shape was characterized by a contact angle of 1°. A velocity profile accounting for Marangoni convection-driven corrosion was derived from the estimated meniscus geometry. Surface tension measurements from LORPM14R1 glasses of varying composition were coupled with K-3 coupon dissolution rates to establish a surface tension–time relationship. This analytical velocity-time model was integrated into the existing CFD framework to improve prediction of the neck corrosion profile. Work was done in a computational setting with national collaboration, resulting in professional development through presentational and technical writing growth.

36 - MATERIALS SCIENCE↗

Glass-contact refractory of the nuclear waste vitrification melters in the United States: a review of corrosion data and melter life

The performance of the refractory lining in glass melters used for nuclear waste vitrification is critical to the melter reliability for long-term continuous operation. Monofrax® K-3, a high Cr 2 O 3 fused cast refractory material, has been widely used to build the liners of nuclear waste glass melters in the United States. Corrosion behaviour of Monofrax® K-3 refractory has been evaluated based on crucible-scale testing, inspection of the refractory components following scaled melter testing, and inspections of the Defense Waste Processing Facility (DWPF) melter refractory after service. The literature generally consists of empirical models based on short-term testing to describe refractory corrosion dependence on glass composition. Corrosion data from tests with longer testing times, at various temperatures, in the presence of molten salts, and with different redox reactions in the plenum atmosphere exist, may be insufficient to provide accurate refractory service life estimates. Additionally, the corrosion data collected under actual and scaled melter operating conditions are limited. Recommendations to achieve more direct correlation between the laboratory refractory corrosion data predictions and the observed melter service life are discussed to allow for more accurate predictions of the useful life of melter refractory linings.

Jin, Tongan↗