Search NASA⌕ Search

SEARCH · Search NASA

Results for “Atomic Resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Miniature Focusing Time-of-Flight Mass Spectrometer

An improved miniature time-of-flight mass spectrometer has been developed in a continuing effort to minimize the sizes, weights, power demands, and costs of mass spectrometers for such diverse applications as measurement of concentrations of pollutants in the atmosphere, detecting poisonous gases in mines, and analyzing exhaust gases of automobiles. Advantageous characteristics of this mass spectrometer include the following: It is simple and rugged. Relative to prior mass spectrometers, it is inexpensive to build. There is no need for precise alignment of its components. Its mass range is practically unlimited Relative to prior mass spectrometers, it offers high sensitivity (ability to measure relative concentrations as small as parts per billion). Its resolution is one dalton (one atomic mass unit). An entire mass spectrum is recorded in a single pulse. (In a conventional mass spectrometer, a spectrum is recorded mass by mass.) The data-acquisition process takes only seconds. It is a lightweight, low-power, portable instrument. Although time-of-flight mass spectrometers (TOF-MSs) have been miniaturized previously, their performances have not been completely satisfactory. An inherent adverse effect of miniaturization of a TOF-MS is a loss of resolution caused by reduction of the length of its flight tube. In the present improved TOF-MS, the adverse effect of shortening the flight tube is counteracted by (1) using charged-particle optics to constrain ion trajectories to the flight-tube axis while (2) reducing ion velocities to increase ion flight times. In the present improved TOF-MS, a stream of gas is generated by use of a hypodermic needle. The stream of gas is crossed by an energy-selected, pulsed beam of electrons (see Figure 1). The ions generated by impingement of the electrons on the gas atoms are then focused by three cylindrical electrostatic lenses, which constitute a segmented flight tube. After traveling along the flight tube, the ions enter a charged-particle detector. The output of the detector is fed to a counting circuit to obtain data on the counting rate as a function of time. Inasmuch as time of flight is directly proportional to the ion mass, a plot of the counting rate versus time of flight is equivalent to a mass spectrum (see Figure 2).

Kanik, Isik↗

Local atomic and electronic structure of oxide/GaAs and SiO2/Si interfaces using high-resolution XPS

The chemical structures of thin SiO2 films, thin native oxides of GaAs (20-30 A), and the respective oxide-semiconductor interfaces, have been investigated using high-resolution X-ray photoelectron spectroscopy. Depth profiles of these structures have been obtained using argon ion bombardment and wet chemical etching techniques. The chemical destruction induced by the ion profiling method is shown by direct comparison of these methods for identical samples. Fourier transform data-reduction methods based on linear prediction with maximum entropy constraints are used to analyze the discrete structure in oxides and substrates. This discrete structure is interpreted by means of a structure-induced charge-transfer model.

Grunthaner, F. J.↗

Multistep modeling of protein structure: application to bungarotoxin

Modelling of bungarotoxin in atomic details is presented in this article. The model-building procedure utilizes the low-resolution crystal coordinates of the c-alpha atoms of bungarotoxin, sequence homology within the neurotoxin family, as well as high-resolution x-ray diffraction data of cobratoxin and erabutoxin. Our model-building procedure involves: (a) principles of comparative modelling, (b) embedding procedures of distance geometry, and (c) use of molecular mechanics for optimizing packing. The model is not only consistent with the c-alpha coordinates of crystal structure, but also agrees with solution conformational features of the triple-stranded beta sheet as observed by NOE measurements.

NASA Discipline Exobiology↗

A Quasi-Laue Neutron Crystallographic Study of D-Xylose Isomerase

Hydrogen atom location and hydrogen bonding interaction determination are often critical to explain enzymatic mechanism. Whilst it is difficult to determine the position of hydrogen atoms using X-ray crystallography even with subatomic (less than 1.0 Angstrom) resolution data available, neutron crystallography provides an experimental tool to directly localise hydrogeddeuteriwn atoms in biological macromolecules at resolution of 1.5-2.0 Angstroms. Linearisation and isomerisation of xylose at the active site of D-xylose isomerase rely upon a complex hydrogen transfer. Neutron quasi-Laue data were collected on Streptomyces rubiginosus D-xylose isomerase crystal using the LADI instrument at ILL with the objective to provide insight into the enzymatic mechanism (Myles et al. 1998). The neutron structure unambiguously reveals the protonation state of His 53 in the active site, identifying the model for the enzymatic pathway.

Meilleur, Flora↗

The physical basis for absorption of light

The effects of light absorption on the wave functions of gas-phase molecules and atoms are investigated by high resolution spectral measurements of radiation emerging from a sample. A Stark-modulated sample of methyl fluoride was irradiated at the 102 GHz rotational transition and the emergent radiation was resolved by means of a spectrum analyzer. For signal oscillator frequencies below or above the molecular resonance by one modulation frequency, the amplitudes of the upper and lower modulation sidebands are found to be of nonuniform intensity, which is inconsistent with amplitude modulation. Emission due to polarization is, however, calculated to be consistent with the results observed, indicating that light absorption should be considered as a subtractive stimulated emission.

Pickett, H. M.↗

A high resolution CO map of M51

Observations of the CO (1-0) emission in two fields of M51 were taken with the Berkeley-Illinois-Maryland Array at Hat Creek, California from May 1988 to February 1989. When combined with two previously observed fields (Lo et al. 1988), a complete map of the central 5 minute x 4 minute at a resolution of 7 seconds x 10 seconds was obtained. The project is part of an ongoing high-resolution survey of the molecular, atomic, and ionized gas distributions in nearby spiral galaxies. The two recently observed fields can be compared to the results of the interferometric study of Vogel et al. (1988 - hereafter VKS). Since the shortest spacing in the current survey is shorter than that of VKS, researchers expect to see more of the extended emission. This is evident when comparing the width of the spiral arms in each survey; ours are a bit broader. While some of the peaks in this region correspond to the peaks in VKS, several of them do not. These discrepancies are probably because of the low signal to noise inherent in observations of this nature. Single-dish maps are currently being readied for inclusion with the interferometer data. These will help fill the short-spacing hole in the UV plane, and serve to recover the flux missing from the interferometer maps.

Adler, D. S.↗

NASA/University Joint Venture in Space Science (JOVE)

This system has an immense complex of optical knots that extend several galactic diameters to the north and south of the main optical object. These are star forming regions, some of which are the size of small irregular galaxies. It has a nearby companion called the 'seashell' owing to its disturbed appearance. The data had been reduced and images formed; a figure is attached. The high resolution observations show that the atomic hydrogen (HI) encompasses not only the N-S complex of optical knots but it forms an incomplete ring or tail that extends approximately 3 arcmins to the west. The seashell was not detected, and the HI associated with NGC 5291 itself shows a very large velocity range. The formation mechanism for this disturbed and distorted complex is unclear. X-ray emission suggesting ram sweeping is also observed. This author favors an explanation involving an interaction between the two components, NGC 5291 and the seashell. We are witnessing the formation of tidal tails and bridges between the galaxies and the associated ejecta. Ram sweeping occurs as the system moves bodily through the medium of the cluster of galaxies, Abell 3574, to which NGC 5291 et al. belong. There are numerous concentrations of HI, mostly along the N-S star forming complexes which generally coincide with the optical knots; the larger features contain several x109 solar mass, again the magnitude of a small irregular galaxy. Each knot was compared to a set of criteria designed to test if the feature was stable against its own internal kinetic energy, and stable against the tidal forces of the host galaxy. At least one of the objects (Knot B) appears to be a bound system suggesting that it is a genuinely young dwarf irregular galaxy that has evolved from the material associated with his interacting complex. We conclude that we are witnessing the early evolution of young galaxies and that NGC 5291 and the seashell are a nursery.

Gottesman, Stephen T.↗

Laser techniques for spectroscopy of core-excited atomic levels

We discuss three techniques which allow the use of tunable lasers for high resolution and picosecond time scale spectroscopy of core-excited atomic levels. These are: anti-Stokes absorption spectroscopy, laser induced emission from metastable levels, and laser designation of selected core-excited levels.

Harris, S. E.↗

Ground-Based Investigations with the Cryogenic Hydrogen Maser

The room temperature hydrogen maser is an active atomic oscillator used as a high-frequency-stability local oscillator for radio astronomy, metrology, and spacecraft navigation, and in tests of fundamental physics. The cryogenic hydrogen maser (CHM) operates at 0.5 K, employing superfluid helium-coated walls to store the masing hydrogen atoms. We are investigating whether the CHM may provide better frequency stability than the room temperature hydrogen maser: one to three orders of magnitude improvement may be possible because of greatly reduced thermal noise and larger signal power. Exceptional frequency stability will be required for spacecraft tracking in future deep-space missions, for space-based tests of relativity and gravitation, and for local (i.e., flywheel) oscillators used with absolute frequency standards such as laser-cooled atomic fountains and linear ion traps. These new devices are passive high-resolution frequency discriminators. Alone, they cannot function as superior atomic clocks; their effective operation depends on being integrated with an active local oscillator with excellent short term stability - such as that possible with the CHM.

Walsworth, Ronald L.↗

Medium-resolution studies of extreme ultraviolet emission from N2 by electron impact - Vibrational perturbations and cross sections of the c4-prime 1Sigma(+)u and b-prime 1Sigma(+)u states

In a crossed-beam experiment the electron-impact-induced fluorescence spectrum of N2 in the extreme ultraviolet is studied at a spectral resolution of up to 0.03 nm. The optically thin experiment obtained the highest-resolution electron-impact emission spectrum of the Rydberg and valence states of N2. The spectral measurements provide the emission cross sections of each of the vibrational transitions of the Carroll-Yoshino and the Birge-Hopfield-II band systems. Laboratory vibrational-excitation cross sections arising from the mutual perturbation of the c4-prime 1Sigma(+)u and b-prime 1Sigma(+)u states by homogeneous configuration interactions are measured from 10 to 400 eV, and a modified Born approximation analytic model is given for them. The analysis leads to accurate band-system oscillator strengths. The relative emission and excitation cross sections each of the vibrational levels are compared. In addition, low-resolution measurements of the cross section of the atomic dissociation fragments (NI, NII, NIII) from 40 to 102 nm are made, and medium-resolution measurements are made of the emission cross section of the c4 1Pi(u), c5-prime 1Sigma(+)u, c5 1Pi(u), and c6-prime 1Sigma(+)u to X 1Sigma(+)g (0,0) transitions.

Ajello, Joseph M.↗

Atom Probe Tomography and Three-Dimensional Atomic Scale Characterisation of Interplanetary Dust Particles: Inorganic and Organic, Hydrous and Anhydrous Assemblages

Interplanetary dust particles (IDPs)preserve primordial fragments from our Solar System and external stellar systems, sampled from a vast range of dust forming bodies that often display smaller degrees of parent body processing than is seen in meteorites. IDPs preserve some of the smallest astromaterials from our Solar System, many of which are believed to be among the most important materials for studying physical and chemical processing, and formation mechanisms occurring within the interstellar medium (ISM), Solar Nebula and external planetary systems[1]. However, their formation processes and provenance are poorly constrained, owing in part to spatial resolution limitations of traditional analytical techniques. Atom probe tomography (APT) uses a pulsed laser to field-evaporate material at the atomic scale from needle-shaped samples, and time-of-flight spectrometry for 3D reconstruction of element and isotope distribution in samples after data acquisition. This technique has the highest spatial resolution available of any technique used within the geoscience field[2]. However, measuring multi-phase specimens and porous media in APT can be challenging, two primary characteristics of IDPs. Here we present a custom method for APT needle design and the first results of a 3Datomic scale study of interplanetary dust particles, salt crystals and extraterrestrial insoluble and soluble organic matter designed to overcome the challenges of studying IDP-like materials.

N D Nevill↗

Highly Charged Ions in a New Era of High Resolution X-Ray Astrophysics

X‐ray astronomy and ground‐based atomic physics have a long history of fruitful collaboration: Sound understanding of the underlying atomic physics is the key to reliable interpretation of the spectra from celestial sources; conversely, astronomical spectra have been used to benchmark and advance atomic physics. This interplay is about to become even more important as we enter a new era of high‐resolution X‐ray astrophysics with large effective collection area. Although high‐resolution observations with the gratings on the Chandra and XMM‐Newton observatories continue to drive new science, upcoming planned and proposed missions will open up new discovery space in the near future that is currently challenging to access: high‐resolution spectroscopy on extended sources, in the Fe K band, and on short time scales. This review summarizes open questions in these areas and the design parameters for the Hitomi, XRISM, Athena, and Arcus observatories. The expected high quality of spectra taken with these observatories puts new constraints on the accuracy of atomic reference data required to take full advantage of the diagnostic potential of these spectra.

Natalie Hell↗

Highly ionized atoms observed with Copernicus

Based on high-resolution observations using the Princeton satellite/spectrometer on Copernicus the O VI doublet is discussed in detail, in conjunction with data for the resonance lines of N V, Si IV, and S IV reported in five stars. The temperature, density, and the possible extent of the O VI producing region are discussed. The ratio N(S IV)/N(O VI) is used to derive a lower limit to the temperature in the O VI producing region. In near pressure equilibrium with normal interstellar clouds and H II regions minimum densities are found to be consistent with a hot plasma.

York, D. G.↗

Bias and uncertainty in the absorption emission measurement of atomic sodium density in the SSME exit plane

The measurement of atomic sodium concentration in the TTB 019 firing of April 1990 is significant in that it represents the first measurement of density at the exit plane of the space shuttle main engine. The knowledge of the sodium density, combined with the certainty that the exit plane of the plume is optically thin at the sodium D-line wavelengths, provides essential information for evaluation of diagnostic techniques using sodium atoms, such as resonant Doppler velocimetry for temperature, pressure, and velocity through high resolution fluorescent lineshape analysis. The technique used for the sodium atom line transmission (SALT) measurements is that of resonant absorption emission using a hollow cathode lamp as the reference source. Through the use of two-dimensional kinetic (TDK) predictions of temperature and density for the flight engine case and radiative transfer calculations, this line-of-sight spectrally integrated transmission indicates a sodium atom concentration, i.e., mole fraction, of 0.91e-10. The subject of this paper is the assumptions and measurement uncertainties tied into the calculation. Because of the narrow shape of the source emission, the uncertainties in the absorption profile could introduce considerable bias in the measurement. The following were investigated: (1) the inclusion of hyperfine splitting of the D-lines in the calculation; (2) the use of the flight engine predictions of plume temperature and density versus those for the large throat engine; (3) the assumption of a Gaussian, i.e., Doppler, distribution for the source radiance with a temperature of 400 K; (4) the use of atomic collisional shift and width values for the work by Jongerius; and (5) a Doppler shift for a 7 degree outward velocity vector at the plume edge. Also included in the study was the bias introduced by an uncertainty in the measurement of the D1/D2 line ratio in the source.

Bauman, Leslie E.↗

Measuring Roughnesses Of Optical Surfaces

Report discusses use of scanning tunneling microscopy and atomic force microscopy to measure roughnesses of optical surfaces. These techniques offer greater spatial resolution than other techniques. Report notes scanning tunneling microscopes and atomic force microscopes resolve down to 1 nm.

Coulter, Daniel R.↗

Galileo ultraviolet spectrometer experiment - Initial Venus and interplanetary cruise results

The Galileo Extreme Ultraviolet Spectrometer obtained a spectrum of Venus atmospheric emissions in the 55.0- to 125.0-nm wavelength region. Emissions of helium (58.4 nm), ionized atomic oxygen (83.4 nm), and atomic hydrogen (121.6 nm), as well as a blended spectral feature of atomic hydrogen (Lyman-beta) and atomic oxygen (102.5 nm), were observed at 3.5-nm resolution. During the Galileo spacecraft cruise from Venus to earth, Lyman-alpha emission from solar system atomic hydrogen (121.6 nm) was measured. The dominant source of the Lyman-alpha emission is atomic hydrogen from the interstellar medium. A model of Galileo observations at solar maximum indicates a decrease in the solar Lyman-alpha flux near the solar poles. A strong day-to-day variation also occurs with the 27-day periodicity of the rotation of the sun.

Hord, C. W.↗