Search NASA⌕ Search

SEARCH · Search NASA

Results for “CCD Camera”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Cell-Detection Technique for Automated Patch Clamping

A unique and customizable machinevision and image-data-processing technique has been developed for use in automated identification of cells that are optimal for patch clamping. [Patch clamping (in which patch electrodes are pressed against cell membranes) is an electrophysiological technique widely applied for the study of ion channels, and of membrane proteins that regulate the flow of ions across the membranes. Patch clamping is used in many biological research fields such as neurobiology, pharmacology, and molecular biology.] While there exist several hardware techniques for automated patch clamping of cells, very few of those techniques incorporate machine vision for locating cells that are ideal subjects for patch clamping. In contrast, the present technique is embodied in a machine-vision algorithm that, in practical application, enables the user to identify good and bad cells for patch clamping in an image captured by a charge-coupled-device (CCD) camera attached to a microscope, within a processing time of one second. Hence, the present technique can save time, thereby increasing efficiency and reducing cost. The present technique involves the utilization of cell-feature metrics to accurately make decisions on the degree to which individual cells are "good" or "bad" candidates for patch clamping. These metrics include position coordinates (x,y) in the image plane, major-axis length, minor-axis length, area, elongation, roundness, smoothness, angle of orientation, and degree of inclusion in the field of view. The present technique does not require any special hardware beyond commercially available, off-the-shelf patch-clamping hardware: A standard patchclamping microscope system with an attached CCD camera, a personal computer with an imagedata- processing board, and some experience in utilizing imagedata- processing software are all that are needed. A cell image is first captured by the microscope CCD camera and image-data-processing board, then the image data are analyzed by software that implements the present machine-vision technique. This analysis results in the identification of cells that are "good" candidates for patch clamping (see figure). Once a "good" cell is identified, a patch clamp can be effected by an automated patchclamping apparatus or by a human operator. This technique has been shown to enable reliable identification of "good" and "bad" candidate cells for patch clamping. The ultimate goal in further development of this technique is to combine artificial-intelligence processing with instrumentation and controls in order to produce a complete "turnkey" automated patch-clamping system capable of accurately and reliably patch clamping cells with a minimum intervention by a human operator. Moreover, this technique can be adapted to virtually any cellular-analysis procedure that includes repetitive operation of microscope hardware by a human.

McDowell, Mark↗

Chemiluminescence Measurements in a Combustor Using a 7-Point Lean Direct Injector Array Configuration for Gas Turbine Engine Applications

This paper reports results for a 7-point lean direct injector (LDI) array for a particular configuration. The LDI configuration in this study used a 60 degrees center pilot swirler and 52.5 degrees on the six outer swirlers. Chemiluminescence images of C2 and CH were collected at a frame rate of 25 Hz using an intensified CCD camera. Narrow bandwidth filters were coupled with the CCD camera in order to spectrally isolate C2 and CH signals. C2 was captured at 515 nm, and the CH signal was acquired at 430 nm. Six inlet conditions were considered in this study, all with the same inlet pressure, 75 psia, and same inlet temperature, 800 degcrees Fahrenheit. These conditions aimed to observe the effect of equivalence ratio, fuel staging, and reference velocity on C2 and CH emissions. Based on the chemiluminescence images, the changes in the inlet conditions was evident in both the pilot and outers. Additionally, the pilot (center injector element) appeared well isolated from the six outer elements under all test conditions.

lean direct injection↗

Design of low noise, high performance X-ray charge-coupled-device cameras

This paper describes some of the critical details of the MIT X-ray CCD camera design. Special attention is given to those portions of the system that deviate from conventional practice in the design of CCD cameras. Furthermore, an attempt has been made to generalize the design so that both optical and X-ray requirements can be satisfied whenever possible. Currently, noise levels of less than 8 electrons rms are routinely achieved with this design, and even lower levels (less than 5 electrons) should be realizable.

Doty, J. P.↗

Measurement of Injector Face Temperature Using Optical Diagnostic Techniques

A CCD camera was previously set up to record infrared images of the injector face of a small rocket combustor. Good semi-quantitative results were obtained but it was found that non-linearities in the camera system made accurate determinations of temperature difficult. A Pulnix CCD camera was purchased and calibrated. The system was calibrated for temperatures between 500 and 850 C. The best filter to use was found to be a BG850 glass filter. The actual calibrations are presented in the report. The system was to be used on a hydrogen oxygen system but the tests did not take place as scheduled. Attempts were made with a methane oxygen system but the carbon in the system interfered with the viewing of the injector face.

Moser, Marlow D.↗

SU-E-J-17: A Study of Accelerator-Induced Cerenkov Radiation as a Beam Diagnostic and Dosimetry Tool

Purpose: To investigate accelerator-induced Cerenkov radiation imaging as a possible beam diagnostic and medical dosimetry tool. Methods: Cerenkov emission produced by clinical accelerator beams in a water phantom was imaged using a camera system comprised of a high-sensitivity thermoelectrically-cooled CCD camera coupled to a large aperture (f/0.75) objective lens with 16:1 magnification. This large format lens allows a significant amount of the available Cerenkov light to be collected and focused onto the CCD camera to form the image. Preliminary images, obtained with 6 MV photon beams, used an unshielded camera mounted horizontally with the beam normal to the water surface, and confirmed the detection of Cerenkov radiation. Several improvements were subsequently made including the addition of radiation shielding around the camera, and altering of the beam and camera angles to give a more favorable geometry for Cerenkov light collection. A detailed study was then undertaken over a range of electron and photon beam energies and dose rates to investigate the possibility of using this technique for beam diagnostics and dosimetry. Results: A series of images were obtained at a fixed dose rate over a range of electron energies from 6 to 20 MeV. The location of maximum intensity was found to vary linearly with the energy of the beam. A linear relationship was also found between the light observed from a fixed point on the central axis and the dose rate for both photon and electron beams. Conclusion: We have found that the analysis of images of beam-induced Cerenkov light in a water phantom has potential for use as a beam diagnostic and medical dosimetry tool. Our future goals include the calibration of the light output in terms of radiation dose and development of a tomographic system for 3D Cerenkov imaging in water phantoms and other media.

07 ISOTOPE AND RADIATION SOURCES↗

Improved Scanners for Microscopic Hyperspectral Imaging

Improved scanners to be incorporated into hyperspectral microscope-based imaging systems have been invented. Heretofore, in microscopic imaging, including spectral imaging, it has been customary to either move the specimen relative to the optical assembly that includes the microscope or else move the entire assembly relative to the specimen. It becomes extremely difficult to control such scanning when submicron translation increments are required, because the high magnification of the microscope enlarges all movements in the specimen image on the focal plane. To overcome this difficulty, in a system based on this invention, no attempt would be made to move either the specimen or the optical assembly. Instead, an objective lens would be moved within the assembly so as to cause translation of the image at the focal plane: the effect would be equivalent to scanning in the focal plane. The upper part of the figure depicts a generic proposed microscope-based hyperspectral imaging system incorporating the invention. The optical assembly of this system would include an objective lens (normally, a microscope objective lens) and a charge-coupled-device (CCD) camera. The objective lens would be mounted on a servomotor-driven translation stage, which would be capable of moving the lens in precisely controlled increments, relative to the camera, parallel to the focal-plane scan axis. The output of the CCD camera would be digitized and fed to a frame grabber in a computer. The computer would store the frame-grabber output for subsequent viewing and/or processing of images. The computer would contain a position-control interface board, through which it would control the servomotor. There are several versions of the invention. An essential feature common to all versions is that the stationary optical subassembly containing the camera would also contain a spatial window, at the focal plane of the objective lens, that would pass only a selected portion of the image. In one version, the window would be a slit, the CCD would contain a one-dimensional array of pixels, and the objective lens would be moved along an axis perpendicular to the slit to spatially scan the image of the specimen in pushbroom fashion. The image built up by scanning in this case would be an ordinary (non-spectral) image. In another version, the optics of which are depicted in the lower part of the figure, the spatial window would be a slit, the CCD would contain a two-dimensional array of pixels, the slit image would be refocused onto the CCD by a relay-lens pair consisting of a collimating and a focusing lens, and a prism-gratingprism optical spectrometer would be placed between the collimating and focusing lenses. Consequently, the image on the CCD would be spatially resolved along the slit axis and spectrally resolved along the axis perpendicular to the slit. As in the first-mentioned version, the objective lens would be moved along an axis perpendicular to the slit to spatially scan the image of the specimen in pushbroom fashion.

Mao, Chengye↗

X-ray pinhole camera setups used in the Atomki ECR Laboratory for plasma diagnostics

Imaging of the electron cyclotron resonance (ECR) plasmas by using CCD camera in combination with a pinhole is a non-destructive diagnostics method to record the strongly inhomogeneous spatial density distribution of the X-ray emitted by the plasma and by the chamber walls. This method can provide information on the location of the collisions between warm electrons and multiple charged ions/atoms, opening the possibility to investigate the direct effect of the ion source tuning parameters to the plasma structure. The first successful experiment with a pinhole X-ray camera was carried out in the Atomki ECR Laboratory more than 10 years ago. The goal of that experiment was to make the first ECR X-ray photos and to carry out simple studies on the effect of some setting parameters (magnetic field, extraction, disc voltage, gas mixing, etc.). Recently, intensive efforts were taken to investigate now the effect of different RF resonant modes to the plasma structure. Comparing to the 2002 experiment, this campaign used wider instrumental stock: CCD camera with a lead pinhole was placed at the injection side allowing X-ray imaging and beam extraction simultaneously. Additionally, Silicon Drift Detector (SDD) and High Purity Germanium (HPGe) detectors were installed to characterize the volumetric X-ray emission rate caused by the warm and hot electron domains. In this paper, detailed comparison study on the two X-ray camera and detector setups and also on the technical and scientific goals of the experiments is presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and Assembly of a Telecentric Zoom Lens for the Cygnus X-ray Source

Cygnus is a high-energy radiographic x-ray source. The rod-pinch x-ray diode produces a point source measuring 1 mm diameter. The target object is placed 1.5 m from the x-ray source, with a large LYSO scintillator at 2.4 m. Different-sized objects are imploded within a containment vessel. A large pellicle deflects the scintillator light out of the x-ray path into an 11-element zoom lens coupled to a CCD camera. The zoom lens and CCD must be as close as possible to the scintillator to maximize light collection. A telecentric lens design minimizes image blur from a volume source. To maximize the resolution of test objects of different sizes, the scintillator and zoom lens can be translated along the x-ray axis. Zoom lens magnifications are changed when different-sized scintillators and recording cameras are used (50 or 62 mm square format). The LYSO scintillator measures 200 × 200 mm and is 5 mm thick. The scintillator produces blue light peaking at 435 nm, so special lens materials are required. By swapping out one lens element and allowing all lenses to move, the zoom lens can also use a CsI(Tl) scintillator that produces green light centered at 550 nm. All lenses are coated with anti-reflective coating for both wavelength bands. Two sets of doublets, the stop, and the CCD camera move during zoom operations. One doublet has XY compensation. The first three lenses use fused silica for radiation damage control. The 60 lb of glass inside the 340 lb mechanical structure is oriented vertically.

42 ENGINEERING↗

Telecentric Zoom Lens Designed for the Cygnus X-Ray Source

Cygnus is a high-energy radiographic x-ray source. Three large zoom lenses have been assembled to collect images from large scintillators. A large elliptical pellicle (394 × 280 mm) deflects the scintillator light out of the x-ray path into an eleven-element zoom lens coupled to a CCD camera. The zoom lens and CCD must be as close as possible to the scintillator to maximize light collection. A telecentric lens design minimizes image blur from a volume source. To maximize the resolution of objects of different sizes, the scintillator and zoom lens are translated along the x-ray axis, and the zoom lens magnification changes. Zoom magnification is also changed when different-sized recording cameras are used (50 or 62 mm square format). The LYSO scintillator measures 200 × 200 mm and is 5 mm thick. The scintillator produces blue light peaking at 435 nm, so special lens materials are required. By swapping out one doublet and allowing all other lenses to be repositioned, the zoom lens can also use a CsI(Tl) scintillator that produces green light centered at 540 nm. All lenses have an anti-reflective coating for both wavelength bands. Two sets of doublets, the stop, the scintillator, and the CCD camera move during zoom operations. One doublet has x-y compensation. Each zoom lens uses 60 lb of glass inside the 425 lb mechanical structure and can be used in either a vertical or horizontal orientation.

Cygnus, telecentric zoom lens↗

Alignment and Testing of a Telecentric Zoom Lens Used for the Cygnus X-ray Source

Cygnus is a high-energy radiographic x-ray source. Three large zoom lenses have been assembled to collect images from large scintillators. A large elliptical pellicle (394 × 280 mm) deflects the scintillator light out of the x-ray path into an eleven-element zoom lens coupled to a CCD camera. The zoom lens and CCD must be as close as possible to the scintillator to maximize light collection. A telecentric lens design minimizes image blur from a volume source. To maximize the resolution of objects of different sizes, the scintillator and zoom lens are translated along the x-ray axis, and the zoom lens magnification changes. Zoom magnification is also changed when different-sized recording cameras are used (50 or 62 mm square format). The LYSO scintillator measures 200 × 200 mm and is 5 mm thick. The scintillator produces blue light peaking at 435 nm, so special lens materials are required. By swapping out one doublet and allowing all other lenses to be repositioned, the zoom lens can also use a CsI(Tl) scintillator that produces green light centered at 540 nm (for future operations). All lenses have an anti-reflective coating for both wavelength bands. Two sets of doublets, the stop, the scintillator, and the CCD camera move during zoom operations. One doublet has x-y compensation. Alignment of the optical elements was accomplished using counter propagating laser beams and monitoring the retro-reflections and steering collections of laser spots. Each zoom lens uses 60 lb of glass inside the 425 lb mechanical structure, and can be used in either vertical or horizontal orientation.

zoom lens, telecentric lens design, optical metrol↗

A novel technique for single-shot energy-resolved 2D x-ray imaging of plasmas relevant for the inertial confinement fusion

A novel x-ray diagnostic of laser-fusion plasmas is described, allowing 2D monochromatic images of hot, dense plasmas to be obtained in any x-ray photon energy range, over a large domain, on a single-shot basis. The device (named energy-encoded pinhole camera) is based upon the use of an array of many pinholes coupled to a large area CCD camera operating in the single-photon mode. The available x-ray spectral domain is only limited by the quantum efficiency of scientific-grade x-ray CCD cameras, thus extending from a few keV up to a few tens of keV. Spectral 2D images of the emitting plasma can be obtained at any x-ray photon energy provided that a sufficient number of photons had been collected at the desired energy. Results from recent inertial confinement fusion related experiments will be reported in order to detail the new diagnostic.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A protection system for the JET ITER-like wall based on imaging diagnostics

The new JET ITER-like wall (made of beryllium and tungsten) is more fragile than the former carbon fiber composite wall and requires active protection to prevent excessive heat loads on the plasma facing components (PFC). Analog CCD cameras operating in the near infrared wavelength are used to measure surface temperature of the PFCs. Region of interest (ROI) analysis is performed in real time and the maximum temperature measured in each ROI is sent to the vessel thermal map. The protection of the ITER-like wall system started in October 2011 and has already successfully led to a safe landing of the plasma when hot spots were observed on the Be main chamber PFCs. Divertor protection is more of a challenge due to dust deposits that often generate false hot spots. In this contribution we describe the camera, data capture and real time processing systems. We discuss the calibration strategy for the temperature measurements with cross validation with thermal IR cameras and bi-color pyrometers. Most importantly, we demonstrate that a protection system based on CCD cameras can work and show examples of hot spot detections that stop the plasma pulse. The limits of such a design and the associated constraints on the operations are also presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A one-megapixel image acquisition and processing system for solar oscillation studies

The 1-Mpixel image acquisition and processing system that has been installed at the Mt. Wilson observatory as part of the development effort for the NASA/ESA Solar Oscillations Imager Experiment of the projected Heliospheric Observatory mission is discussed. The system encompasses a high speed CCD camera with a 1024 x 1024-pixel virtual phase chip array, yielding a readout rate of about 800,000 pixels/sec; this allows the entire Mpixel array to be read out in just over 1 sec. The camera is interfaced with a floating point array processor that integrates several successive exposures from the CCD camera and differences selected pairs of integrated images. The system is currently being used to record and difference narrowband images of the sun.

Rhodes, Edward J., Jr.↗

Photometric Studies of GEO Orbital Debris

The photometric signature of a debris object can be useful in determining what the physical characteristics of a piece of debris are. We report on optical observations in multiple filters of debris at geosynchronous Earth orbit (GEO). Our sample is taken from GEO objects discovered in a survey with the University of Michigan's 0.6-m aperture Schmidt telescope MODEST (for Michigan Orbital DEbris Survey Telescope), and then followed up in real-time with the Cerro Tololo Inter- American Observatory (CTIO) 0.9-m for orbits and photometry. Our goal is to determine 6 parameter orbits and measure colors for all objects fainter than R=15th magnitude that are discovered in the MODEST survey. At this magnitude the distribution of observed angular rates changes significantly from that of brighter objects. There are two objectives: 1. Estimate the orbital distribution of objects selected on the basis of two observational criteria: brightness (magnitude) and angular rates. 2. Obtain magnitudes and colors in standard astronomical filters (BVRI) for comparison with reflectance spectra of likely spacecraft materials. What is the faint debris likely to be? More than 90 calibrated sequences of R-B-V-I-R magnitudes for a sample of 50 objects have been obtained with the CTIO 0.9-m. For objects that do not show large brightness variations, the colors are largely redder than solar in both B-R and R-I. The width of the color distribution may be intrinsic to the nature of the surfaces, but also could be that we are seeing irregularly shaped objects and measuring the colors at different times with just one telescope. For a smaller sample of objects we have observed with synchronized CCD cameras on the two telescopes. The CTIO 0.9-m observes in B, and MODEST in R. The CCD cameras are electronically linked together so that the start time and duration of observations are the same to better than 50 milliseconds. Thus the B-R color is a true measure of the surface of the debris piece facing the telescopes for that observation. Any change in color reflects a real change in the debris surface. We will compare our observations with models and laboratory measurements of selected surfaces.

Seitzer, Patrick↗

Photometric Studies of GEO Debris

The photometric signature of a debris object can be useful in determining what the physical characteristics of a piece of debris are. We report on optical observations in multiple filters of debris at geosynchronous Earth orbit (GEO). Our sample is taken from GEO objects discovered in a survey with the University of Michigan's 0.6-m aperture Schmidt telescope MODEST (for Michigan Orbital DEbris Survey Telescope), and then followed up in real-time with the SMARTS (Small and Medium Aperture Research Telescope System) 0.9-m at CTIO for orbits and photometry. Our goal is to determine 6 parameter orbits and measure colors for all objects fainter than R = 15 th magnitude that are discovered in the MODEST survey. At this magnitude the distribution of observed angular rates changes significantly from that of brighter objects. There are two objectives: 1. Estimate the orbital distribution of objects selected on the basis of two observational criteria: brightness (magnitude) and angular rates. 2. Obtain magnitudes and colors in standard astronomical filters (BVRI) for comparison with reflectance spectra of likely spacecraft materials. What is the faint debris likely to be? In this paper we report on the photometric results. For a sample of 50 objects, more than 90 calibrated sequences of R-B-V-I-R magnitudes have been obtained with the CTIO 0.9-m. For objects that do not show large brightness variations, the colors are largely redder than solar in both B-R and R-I. The width of the color distribution may be intrinsic to the nature of the surfaces, but also could be that we are seeing irregularly shaped objects and measuring the colors at different times with just one telescope. For a smaller sample of objects we have observed with synchronized CCD cameras on the two telescopes. The CTIO 0.9-m observes in B, and MODEST in R. The CCD cameras are electronically linked together so that the start time and duration of observations are the same to better than 50 milliseconds. Thus the B-R color is a true measure of the surface of the debris piece facing the telescopes for that observation. Any change in color reflects a real change in the debris surface.

Seitzer, Patrick↗

Optical Photometric Observations of GEO Debris

We report on a continuing program of optical photometric measurements of faint orbital debris at geosynchronous Earth orbit (GEO). These observations can be compared with laboratory studies of actual spacecraft materials in an effort to determine what the faint debris at GEO may be. We have optical observations from Cerro Tololo Inter-American Observatory (CTIO) in Chile of two samples of debris: 1. GEO objects discovered in a survey with the University of Michigan's 0.6-m aperture Curtis-Schmidt telescope MODEST (for Michigan Orbital DEbris Survey Telescope), and then followed up in real-time with the CTIO/SMARTS 0.9-m for orbits and photometry. Our goal is to determine 6 parameter orbits and measure colors for all objects fainter than R = 15 t11 magnitude that are discovered in the MODEST survey. 2. A smaller sample of high area to mass ratio (AMR) objects discovered independently, and acquired using predictions from orbits derived from independent tracking data collected days prior to the observations. Our optical observations in standard astronomical BVRI filters are done with either telescope, and with the telescope tracking the debris object at the object's angular rate. Observations in different filters are obtained sequentially. We have obtained 71 calibrated sequences of R-B-V-I-R magnitudes. A total of 66 of these sequences have 3 or more good measurements in all filters (not contaminated by star streaks or in Earth's shadow). Most of these sequences show brightness variations, but a small subset has observed brightness variations consistent with that expected from observational errors alone. The majority of these stable objects are redder than a solar color in both B-R and R-I. There is no dependence on color with brightness. For a smaller sample of objects we have observed with synchronized CCD cameras on the two telescopes. The CTIO 0.9-m observes in B, and MODEST in R. The CCD cameras are electronically linked together so that the start time and duration of observations are the same to better than 50 milliseconds. Thus, the B-R color is a true measure of the surface of the debris piece facing the telescopes for that observation. Any change in color reflects a real change in the debris surface. We will compare our observations with models and laboratory measurements of selected surfaces.

Seitzer, Patrick↗

Photometric Studies of Orbital Debris at GEO

Orbital debris represents a significant and increasing risk to operational spacecraft. Here we report on photometric observations made in standard BVRI filters at the Cerro Tololo Inter-American Observatory (CTIO) in an effort to determine the physical characteristics of optically faint debris at geosynchronous Earth orbit (GEO). Our sample is taken from GEO objects discovered in a survey with the University of Michigan s 0.6-m Curtis-Schmidt telescope (known as MODEST, for Michigan Orbital DEbris Survey Telescope), and then followed up in real-time with the CTIO/SMARTS 0.9-m for orbits and photometry. For a sample of 50 objects, calibrated sequences in RB- V-I-R filters have been obtained with the CTIO/SMARTS 0.9-m. For objects that do not show large brightness variations, the colors are largely redder than solar in both B-R and R-I. The width of the color distribution may be intrinsic to the nature of the surfaces, but also could imply that we are seeing irregularly shaped objects and measuring the colors at different times with just one telescope. For irregularly shaped objects tumbling at unknown orientations and rates, such sequential filter measurements using one telescope are subject to large errors for interpretation. If all observations in all filters in a particular sequence are of the same surface at the same solar and viewing angles, then the colors are meaningful. Where this is not the case, interpretation of the observed colors is impossible. For a smaller sample of objects we have observed with synchronized CCD cameras on the two telescopes. The CTIO/SMARTS 0.9-m observes in B, and the Schmidt in R. The CCD cameras are electronically linked together so that the start time and duration of observations are both the same to better than 50 milliseconds. Now the observed B-R color is a true measure of the scattered illuminated area of the debris piece for that observation.

Seitzer, Patrick↗

Second-Generation Multi-Angle Imaging Spectroradiometer

A report discusses an early phase in the development of the MISR-2 C, a second, improved version of the Multi-angle Imaging SpectroRadiometer (MISR), which has been in orbit around the Earth aboard NASA's Terra spacecraft since 1999. Like the MISR, the MISR-2 would contain a pushbroom array of nine charge-coupled- device (CCD) cameras one aimed at the nadir and the others aimed at different angles sideways from the nadir. The major improvements embodied in the MISR-2 would be the following: A new folded-reflective-optics design would render the MISR-2 only a third as massive as the MISR. Smaller filters and electronic circuits would enable a reduction in volume to a sixth of that of the MISR. The MISR-2 would generate images in two infrared spectral bands in addition to the blue, green, red, and near-infrared spectral bands of the MISR. Miniature polarization filters would be incorporated to add a polarization-sensing capability. Calibration would be performed nonintrusively by use of a gimbaled tenth camera. The main accomplishment thus far has been the construction of an extremely compact all-reflective-optics CCD camera to demonstrate feasibility.

Macenka, Steven↗