Design of a multichannel photonic crystal dielectric laser accelerator

To be useful for most scientific and medical applications, compact particle accelerators will require much higher average current than enabled by current architectures. For this purpose, we propose a photonic crystal architecture for a dielectric laser accelerator, referred to as a multi-input multi-output silicon accelerator (MIMOSA), that enables simultaneous acceleration of multiple electron beams, increasing the total electron throughput by at least 1 order of magnitude. To achieve this, we show that the photonic crystal must support a mode at the Γ point in reciprocal space, with a normalized frequency equal to the normalized speed of the phase-matched electron. We show that the figure of merit of the MIMOSA can be inferred from the eigenmodes of the corresponding infinitely periodic structure, which provides a powerful approach to design such devices. Additionally, we extend the MIMOSA architecture to electron deflectors and other electron manipulation functionalities. These additional functionalities, combined with the increased electron throughput of these devices, permit all-optical on-chip manipulation of electron beams in a fully integrated architecture compatible with current fabrication technologies, which opens the way to unconventional electron beam shaping, imaging, and radiation generation.

43 PARTICLE ACCELERATORS↗

Conversion of the LLNL/CAMS 1 MV biomedical AMS system to a semi-automated natural abundance 14C spectrometer: system optimization and performance evaluation

The Lawrence Livermore National Laboratory – Center for Accelerator Mass Spectrometry compact 1 MV biomedical accelerator mass spectrometer was repurposed and optimized for the semi-automated radiocarbon measurement of natural abundance environmental samples. Here we present results from 15 months of routine system operation and evaluate the system performance based on 30 sample wheels measured with consistent operating conditions over 7 months from August 2019 to March 2020. Additionally, the average measurement precision was 2.7 ± 0.7‰. System accuracy was assessed with measurements of 14 C-free materials, standard materials with 14 C-content spanning 0.5 to 1.5 F 14 C, and by comparison to split samples measured with the 10 MV AMS system. Overall, this system can routinely measure samples as small as 300 µgC and less than 33000 years without the need for size-specific correction protocols.

43 PARTICLE ACCELERATORS↗

Enhanced Isomer Population via Direct Irradiation of Solid-Density Targets Using a Compact Laser-Plasma Accelerator

Excitation of long-lived states in bromine nuclei using a tabletop laser-plasma accelerator providing pulsed (<100 fs) electron beams provided a sensitive probe of γ strength and level densities in the nuclear quasicontinuum and may indicate angular momentum coupling through electron-nuclear interactions. Solid-density active $LaBr_{3}$ targets absorb real and virtual photons up to 35 ± 2.5 MeV and deexcite through γ cascade into different states. Here, a factor of 4.354 ± 0.932 enhancement of the $^{80}Br^{m}/^{80}Br^{g}$ isomeric ratio was observed following electron irradiation, as compared to bremsstrahlung. Additional angular momentum transfer could possibly occur through nuclear-plasma or electron-nuclear interactions enabled by the ultrashort electron beam. Further investigation of these mechanisms could have far-reaching impact including decreased storage of long-term nuclear waste and an improved understanding of heavy element formation in astrophysical settings.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Compact high gradient ion accelerating structure

A high gradient linear accelerating structure can propagate high frequency waves at a negative harmonic to accelerate low-energy ions. The linear accelerating structure can provide a gradient of 50 MV/m for particles at a β of between 0.3 and 0.4. The high gradient structure can be a part of a linear accelerator configured to provide an energy range from an ion source to 450 MeV/u for 12 C 6+ and 250 MeV for protons. The linear accelerator can include one or more of the following sections: a radiofrequency quadrupole (RFQ) accelerator operating at the sub-harmonic of the S-band frequency, a high gradient structure for the energy range from ˜45 MeV/u to ˜450 MeV/u.

Kutsaev, Sergey↗

Beam Loss Assessment Through Use of Photomultiplier Tubes

Modern accelerators aim to deliver maximal beam current at stable energy with minimal beam loss. Environmental changes, among other factors, can result in increased beam loss and decreased beam throughput, prompting daily retuning of the accelerator. The compact nature of the oldest part of the linear accelerator limits the available beam instrumentation, making beam loss assessment and tuning difficult. Thus, additional devices for beam loss monitoring must be considered. Photomultiplier tube-based beam loss monitors (BLMs) were installed along the Fermilab drift tube Linac to assess beam loss. Due to noise, the data from the installed photomultiplier tubes was difficult to assess. After noise reduction and signal analysis, it was found that the signals produced by the photomultiplier tubes in response to beam loss were consistent for a given configuration and therefore a reasonable measure of beam loss. This project lays groundwork for future work in beam loss assessment using photomultiplier tubes, with the automation of the process developed in this project being the next step in this effort.

Waggoner, Alexander↗

Linear Induction Accelerator Cell Voltage Calibration Using Compact Electron Permanent Magnet Spectrometer

The Dual-Axis Radiographic Hydrodynamic Test (DARHT) facility provides flash radiography capabilities using electron Linear Induction Accelerators (LIA’s). The strict requirements for flash radiography require a detailed understanding of the LIA’s performance, including precision measurements of the electron beam energy. Axis-1 of DARHT produces a 20 MeV, 2 kA, 80-ns-FWHM electron beam. Electronic measurement with cell-voltage monitors which consists of a 75 ohm load resistor and a current viewing resistor (CVR) that are coupled together and injector capacitive monitors (EVACSUM) are summed to give the total beam energy at the output of the accelerator. Calibration of these monitors was last done in 1999 and is needed. Using the Compact electron Permanent Magnet Spectrometer (CePMSpec), we have developed a technique for measuring and adjusting the calibration of the accelerator cell load resistor/CVR by using the total energy of the beam. Each pair of cells is driven by pulsed power Blumleins, and each Blumlein is charged by a Blumlein Charge Unit (BCU). There are 64 cells and 32 Blumleins and BCUs. This technique is applied to all 32 BCUs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A compact electron source for the dielectric laser accelerator

In this work, we design and demonstrate a compact electron source that combines an integrated silicon nanotip photoemitter with a compact silicon-based electrostatic lens. The lens simultaneously accelerates electrons to 30 keV and focuses the resulting beam to a 0.4 μm (RMS) beam diameter with 62 pm-rad normalized emittance at a distance of 20 mm from the cathode. The compact nature of this lens provides a compelling source for dielectric laser accelerator (DLA) beamlines, ultrafast electron diffraction, or ultrafast electron microscopy. Driven by a 220 fs, 1960 nm pulsed laser beam, electron currents up to 28 electrons/pulse at 100 kHz are demonstrated. The electron bunch length is 540 ± 50 fs for photocurrents of <1 electron/pulse, increasing to 700 ± 80 fs for 28 electrons/pulse, as measured by cross correlation with a 220 fs pulsed laser beam. The maximum 5D peak brightness is measured to be 6.8 × 10 13 A/(m 2 rad 2 ) at 28 electrons/pulse. These results represent a significant step toward developing practical benchtop-sized linear accelerators based on DLA technology or compact ultrafast electron microscopy and diffraction applications.

47 OTHER INSTRUMENTATION↗

Ion Channel Laser Based on Direct Laser Acceleration of a Shaped Beam Driver (Final Technical Report)

The main focus of our research was to understand the synergies between an electron bunch and a laser pulse when the two co-propagate through the plasma. We have clearly demonstrated using theoretical and computational modeling that the propagation distance of both the bunch and the laser pulse could be extended. The ability of the combined bunch/pulse system to extend the propagation distance and the size of the plasma bubble enables highly-efficient sources of relativistic electrons. As pointed out by the Plasma Decadal Study, such electron sources can be used for generating extremely bright x-rays for a variety of applications can serve as probes and diagnostics for other plasma experiments: high energy density (HED) sciences, inertial confinement fusion (ICF), and potentially Fusion Materials and Technology (FM&T). Development of advanced diagnostics of plasma-based accelerators is yet another key area identified by recent reports. Even broader security and medical applications of compact accelerator-based radiation sources, such as very high energy electron (VHEE) sources for FLASH radiobiology, have been identified by a recent multi-agency panel. A number of key technical issues were considered and successfully resolved during the course of the grant. Those include: beam loading effect of both the driver and witness bunches on the wake, laser channeling by the bunch, and the direct laser acceleration (DLA) of the driver bunch by the laser pulse. To demonstrate clear synergy, we were able to ascertain that the total energy gain of a witness bunch in the wake of the combined bunch/laser complex is large than the sum of the energy gains in the wake of the laser pulse alone, and the driver bunch alone. We have also demonstrated that not only the energy gain is improved, but the energy spread is not sacrificed. To carry out these simulations, we have to develop a range of in-house computational tools, including a fully-3D code WAND-PIC.

43 PARTICLE ACCELERATORS↗

Laser-driven acceleration of quasi-monoenergetic, near-collimated titanium ions via a transparency-enhanced acceleration scheme

Laser-driven ion acceleration has been an active research area in the past two decades with the prospects of designing novel and compact ion accelerators. Many potential applications in science and industry require high-quality, energetic ion beams with low divergence and narrow energy spread. Intense laser ion acceleration research strives to meet these challenges and may provide high charge state beams, with some successes for carbon and lighter ions. Here we demonstrate the generation of well collimated, quasi-monoenergetic titanium ions with energies ~145 and 180 MeV in experiments using the high-contrast(<10-9) and high-intensity (6× 1020 W cm-2) Trident laser and ultra-Thin (~100 nm) titanium foil targets. Numerical simulations show that the foils become transparent to the laser pulses, undergoing relativistically induced transparency (RIT), resulting in a two-stage acceleration process which lasts until ~2 ps after the onset of RIT. Such long acceleration time in the self-generated electric fields in the expanding plasma enables the formation of the quasi-monoenergetic peaks. This work contributes to the better understanding of the acceleration of heavier ions in the RIT regime, towards the development of next generation laser-based ion accelerators for various applications.

74 ATOMIC AND MOLECULAR PHYSICS↗

Spatiotemporal Structure in Intense THz Pulsed Beams

Optically generated terahertz radiation, with gigavolt per meter (GV/m) electric fields accessible in tabletop experiments, provides a promising source of accelerating gradients for future particle accelerator applications. Manipulation and characterization of radiation is essential for efficiently producing high fields and effectively delivering them to an accelerating structure or interaction region. The talk will cover a method of generating and characterizing high quality and structured terahertz pulsed laser beams for compact particle acceleration.

Hine, George↗

Advanced Modeling of Plasma-based Particle Accelerators

Plasma-based acceleration (PBA) driven by an intense laser (LWFA) or particle beam (PWFA) can produce ultra-high accelerating fields in excess of a GV/cm. PBA could substantially reduce the size and cost of future linear collider facilities if deployed successfully. PBA enables compact tabletop accelerators that can provide lower energy GeV-class beams in a laboratory setting. PBA enables high quality beam generation suitable for x-ray free electron lasers (XFEL) via controllable methods of self-injection. Challenges in modeling and optimization of multi-stage PBA motivate the need for exascale computing and state-of-the-art PIC codes.

43 PARTICLE ACCELERATORS↗

Generation of straight and curved hollow plasma channels by laser-generated nonlinear wakefields and studies of ultra-intense laser pulse guiding

We report on a study of highly controllable, quasi-static hollow plasma channels generated by ion motion following a laser–plasma interaction via numerical simulations. These channels are generated by ion motion in a nonlinear wakefield, which has an asymmetry between focusing and defocusing periods. Such plasma channels, driven by a fs duration, 100 TW level laser pulse, have the capability to guide more powerful laser pulses. Moreover, we show that curved plasma channels can be generated in a transverse density gradient plasma and alloptical guiding of a second, significantly more powerful laser pulse in such a curved plasma channel. This mechanism may be useful for creating plasma optics for multi-stage TeV laser plasma accelerators and compact synchrotron radiation sources.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High-energy ion beams generated with high efficiency using laser-driven 3D microstructures

Laser-driven ion acceleration in plasma is being proposed as a source of ion beams with a high peak current that can be useful in many fields of science and medicine. Using this method, high proton energies have been achieved by increasing the laser power and by using ultrathin (≤ 200 nm) foils. However, this approach is limited by survivability of the nanotargets to laser prepulses and by difficulty in controlling the plasma acceleration properties. Here, we introduce a new target platform using two-photon polymerization, 3D laser-printed “clone” microstructures with average densities lower than solid that are relatively insensitive to the laser prepulse. Two types of microstructured targets consisting of either a multilayered log-pile or a stochastic arrangement of one micron diameter wires are used. Both demonstrate a higher energy and higher yield proton acceleration compared to thin solid-density foil targets by the robust target normal sheath acceleration (TNSA) mechanism. We find that when such 10–20 μm thick structures are irradiated with a petawatt laser, protons with energies up to 110 MeV and a laser-to-proton conversion efficiency of ~ 10% are obtained. Our work suggests that such microstructures optimized for 60–200 MeV compact proton accelerators are promising for future radiotherapy and other applications.

Physics - Plasma physics↗

MIND-MAC: Multi-Level In-memory Quasi Non-Destructive MAC Operation in Compact 2T-nC FeRAM for Efficient DNN Accelerator

We present MIND-MAC, a compact 2T-nC FeRAM architecture that performs multi-level, quasi-non-destructive in-memory multiply–accumulate (MAC) for deep neural networks. By exploiting voltage-controlled partial domain switching in MFM capacitors and read-transistor amplification, the cell stores multi-bit weights and gates bit-serial inputs to produce an accumulated current on shared lines. We combine TCAD-extracted parasitics with experimentally calibrated ferroelectric models in SPICE to validate device-/circuit-level behavior, and validate multi-level sensing and QNRO with measurements on a fabricated 2T-3C test vehicle. An analytical system model maps MIND-MAC to a 6-GB main-memory in-memory compute (IMC) architecture and benchmarks VGG13 inference in 61.08 ms at 964.99 mJ. Results indicate high density, reduced rewrite overhead, and energy efficiency, positioning 2T-nC FeRAM as a promising IMC candidate for next-generation AI hardware.

36 MATERIALS SCIENCE↗

Beam optics design of a prototype 20 kW conduction-cooled SRF accelerator for medical sterilization

Superconducting technology has significantly advanced the capabilities of particle accelerators, facilitating higher beam-power operations for fundamental research at a comparatively lower cost. However, the conventional implementation of superconducting technology introduces complexities in the form of cryogenic plants, cryogenic distribution systems and substantial construction and operational cost. In response to these challenges, recent research efforts at Fermilab have been dedicated to the development of a cryogen-free, conduction-cooled Nb3Sn-based superconducting technology. This paper outlines the beam optics design of a 20-kW conduction-cooled compact superconducting accelerator for medical sterilization. The paper reviews both the physics and practical constraints associated with high beam-power operation within the context of industrial applications. The focus is on providing insights into the potential of this innovative technology to overcome existing challenges and pave the way for more accessible and efficient industrial particle accelerators.

Saini, A. [Fermilab]↗

Beam Optics Design of A Prototype 20 kW Conduction-Cooled SRF Accelerator for Medical Sterilization

Superconducting technology has significantly advanced the capabilities of particle accelerators, facilitating higher beam-power operations for fundamental research at a comparatively lower cost. However, the conventional implementation of superconducting technology introduces complexities in the form of cryogenic plants, cryogenic distribution systems and substantial construction and operational cost. In response to these challenges, recent research efforts at Fermilab have been dedicated to the development of a cryogen-free, conduction-cooled Nb3Sn-based superconducting technology. This paper outlines the beam optics design of a 20-kW conduction-cooled compact superconducting accelerator for medical sterilization. The paper reviews both the physics and practical constraints associated with high beam-power operation within the context of industrial applications. The focus is on providing insights into the potential of this innovative technology to overcome existing challenges and pave the way for more accessible and efficient industrial particle accelerators.

43 PARTICLE ACCELERATORS↗