Search NASA⌕ Search

SEARCH · Search NASA

Results for “Compatibility error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

SU-D-209-01: Can Fluoroscopic Air-Kerma Rates Be Reliably Measured with Solid-State Meters?

Purpose: Ionization chambers remain the standard for calibration of air-kerma rate measuring devices. Despite their strong energy-dependent response, solid state radiation detectors are increasingly used, primarily due to their efficiency in making standardized measurements. To test the reliability of these devices in measuring air-kerma rates, we compared ion chambers measurements with solid-state measurements for various mobile fluoroscopes operated at different beam qualities and air-kerma rates. Methods: Six mobile fluoroscopes (GE OEC models 9800 and 9900) were used to generate test beams. Using various field sizes and dose rate controls, copper attenuators and a lead attenuator were placed at the image receptor in varying combinations to generate a range of air-kerma rates. Air-kerma rates at 30 centimeters from the image receptors were measured using two 6-cm{sup 3} ion chambers with electrometers (Radcal, models 1015 and 9015) and two with solid state detectors (Unfors Xi and Raysafe X2). No error messages occurred during measurements. However, about two months later, one solid-state device stopped working and was replaced by the manufacturer. Two out of six mobile fluoroscopic units were retested with the replacement unit. Results: Generally, solid state and ionization chambers agreed favorably well, with two exceptions. Before replacement of the detector, the Xi meter when set in the “RF High” mode deviated from ion chamber readings by factors of 2 and 10 with no message indicating error in measurement. When set in the “RF Low” mode, readings were within −4% to +3%. The replacement Xi detector displayed messages alerting the user when settings were not compatible with air-kerma rates. Conclusion: Air-kerma rates can be measured favorably well using solid-state devices, but users must be aware of the possibility that readings can be grossly in error with no discernible indication for the deviation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Direct estimation of the density of states for fermionic systems

Simulating time evolution is one of the most natural applications of quantum computers and is thus one of the most promising prospects for achieving practical quantum advantage. Here, we develop quantum algorithms to extract thermodynamic properties by estimating the density of states (DOS), which is a central object in quantum statistical mechanics. We introduce several key innovations that significantly improve the practicality and extend the generality of previous techniques. First, our approach allows one to estimate the DOS only for a specific subspace of the full Hilbert space. This is crucial for fermionic systems, since both canonical and grand canonical ensemble thermal equilibrium properties depend on subspaces of fixed number. Second, in our approach, by time evolving very simple, random initial states, such as randomly chosen computational basis states, we can exactly recover the DOS on average. Third, due to circuit-depth limitations, we only reconstruct the DOS up to a convolution with a Gaussian window—thus all imperfections that shift the energy levels by less than the width of the convolution window will not significantly affect the estimated DOS. For these reasons, we find the approach is a promising candidate for early quantum advantage as even short-time, noisy dynamics can yield a semiquantitative reconstruction of the DOS (convolution with a broad Gaussian window), while early fault-tolerant devices will likely enable higher-resolution DOS reconstruction through longer time evolutions. We demonstrate the practicality of our approach in representative Fermi-Hubbard and spin models and indeed find that our approach is highly robust against algorithmic errors in the time evolution and against gate noise. We further demonstrate that our approach is compatible with noisy intermediate-scale quantum (NISQ) computing NISQ-friendly variational techniques, introducing and leveraging a technique for variational time evolution.

97 MATHEMATICS AND COMPUTING↗

Frequency Domain Detection and Precoding for Massive MIMO With Single Carrier Modulation

Single carrier modulation (SCM) schemes are attractive for uplink (UL) transmissions due to improved power efficiency at the user equipment (UE) transmitter compared with multi-carrier modulation schemes. In a massive MIMO scenario with SCM, the UL detection must mitigate the effects of inter-symbol interference and multiuser interference. This processing is effectively performed in the frequency domain (FD) using a minimum mean squared error (MMSE) detector when the transmission is framed with a cyclic prefix. This paper presents a MMSEbased detector that is compatible with distributed processing in a time-division duplex (TDD) system. The matrix inverses computed for the UL detection are then reused to perform multi-user precoding for the downlink (DL). We find that this scheme yields a tremendous savings in computational complexity compared to commonly used zero-forcing (ZF) precoding without sacrificing any performance. Since MMSE processing introduces a bias to the estimates, we then derive the scalar coefficients necessary to cancel the MMSE bias. The impact of channel estimation errors are analyzed for both the UL and DL cases in conjunction with a power-efficient approach to SCM channel estimation. Moreover, extensive simulations are performed to confirm our theoretical findings.

42 ENGINEERING↗

Ordering of Trotterization: Impact on Errors in Quantum Simulation of Electronic Structure

Trotter–Suzuki decompositions are frequently used in the quantum simulation of quantum chemistry. They transform the evolution operator into a form implementable on a quantum device, while incurring an error—the Trotter error. The Trotter error can be made arbitrarily small by increasing the Trotter number. However, this increases the length of the quantum circuits required, which may be impractical. It is therefore desirable to find methods of reducing the Trotter error through alternate means. The Trotter error is dependent on the order in which individual term unitaries are applied. Due to the factorial growth in the number of possible orderings with respect to the number of terms, finding an optimal strategy for ordering Trotter sequences is difficult. In this paper, we propose three ordering strategies, and assess their impact on the Trotter error incurred. Initially, we exhaustively examine the possible orderings for molecular hydrogen in a STO-3G basis. We demonstrate how the optimal ordering scheme depends on the compatibility graph of the Hamiltonian, and show how it varies with increasing bond length. We then use 44 molecular Hamiltonians to evaluate two strategies based on coloring their incompatibility graphs, while considering the properties of the obtained colorings. We find that the Trotter error for most systems involving heavy atoms, using a reference magnitude ordering, is less than 1 kcal/mol. Relative to this, the difference between ordering schemes can be substantial, being approximately on the order of millihartrees. The coloring-based ordering schemes are reasonably promising—particularly for systems involving heavy atoms—however further work is required to increase dependence on the magnitude of terms. Finally, we consider ordering strategies based on the norm of the Trotter error operator, including an iterative method for generating the new error operator terms added upon insertion of a term into an ordered Hamiltonian.

97 MATHEMATICS AND COMPUTING↗

Performance evaluations of signed and unsigned noisy approximate quantum Fourier arithmetic

The Quantum Fourier Transform (QFT) grants competitive advantages, especially in resource usage and circuit approximation, for performing arithmetic operations on quantum computers, and offers a potential route toward a numerical quantum-computational paradigm. In this paper, we utilize efficient techniques to implement QFT-based integer addition and multiplications. These operations are fundamental to various quantum applications including Shor’s algorithm, weighted-sum optimization problems in data processing and machine learning, and quantum algorithms requiring inner products. We carry out performance evaluations of these implementations based on IBM’s superconducting-qubit architecture using different compatible noise models. We isolate the sensitivity of the component quantum circuits on both one-/two-qubit gate error rates, and the number of the arithmetic operands’ superposed integer states. We analyze performance and identify the most effective approximation depths for unsigned quantum addition and quantum multiplication within the given context. We then perform a similar analysis of signed addition and compare to the unsigned results. We observe significant dependency of the optimal approximation depth on the degree of machine noise and the number of superposed states in certain performance regimes. Finally, we elaborate on the algorithmic challenges—relevant to signed, unsigned, modular and non-modular versions—that could also be applied to current implementations of QFT-based subtraction, division, exponentiation, and their potential tensor extensions. Here, we analyze the performance trends in our results and speculate on possible future developments within this computational paradigm.

Computational models↗

A method for characterization of multiple dynamic constitutive parameters of FRCs

We propose a method to measure multiple dynamic material constitutive parameters of unidirectional fiber reinforced composites (FRCs) in a single experiment. Dynamic short-beam shear (DSBS) experiments were performed on a modified Kolsky compression bar, with integration of high-speed imaging and digital image correlation (DIC). The unidirectional FRCs investigated were S-2 glass fiber reinforced matrix of TGDDM-Jeffamine® D230 with monoamine functionalized partially reacted substructures (mPRS) and commercially available SC-15. Analytical solutions of normal and shear strains of a composite beam were derived based on Timoshenko beam theory, assuming material to be transversely isotropic and have different moduli in tension and compression in each principle material orientation. Tensile and compressive moduli were inversely computed through monitoring normal strain slope when specimen was constantly loaded at a speed of ~7.3 m/s within a small deflection. Non-linear shear stress-strain behavior of the composite was described via Ramberg–Osgood equation. Finite element (FE) analysis was conducted in ABAQUS, simultaneously defining via user subroutine UMAT the transverse isotropy of material, bi-modulus constitutive model, and non-linear shear stress-strain relation. The method proposed in this work was validated by comparing strain distributions computed by FE model and DIC measurements. Comparing with traditional dynamic tensile, compressive, and shear experiments on FRCs, this method significantly simplifies the specimen preparation and design of complicated gripping fixtures for multiple experiments. Here, systematic errors resulting from variations of specimen geometry and dimension, loading direction, and instrumentation are reduced, thereby providing compatible data for numerical studies on impact behavior of composites.

36 MATERIALS SCIENCE↗

Coherent pion production off nuclei at T2K and MiniBooNE energies revisited

As a result of a new improved fit to old bubble chamber data of the dominant axial C{sub 5}{sup A} nucleon-to-delta form factor, and due to the relevance of this form factor for neutrino induced coherent pion production, we reevaluate our model predictions in [Phys. Rev. D 79, 013002 (2009)] for different observables of the latter reaction. Central values for the total cross sections increase by 20%-30%, while differential cross sections do not change their shape appreciably. Furthermore, we also compute the uncertainties on total, differential, and flux-averaged cross sections induced by the errors in the determination of C{sub 5}{sup A}. Our new results turn out to be compatible within about 1{sigma} with the former ones. Finally, we stress the existing tension between the recent experimental determination of the ({sigma}(CCcoh{pi}{sup +})/{sigma}(NCcoh{pi}{sup 0})) ratio by the SciBooNE Collaboration and the theoretical predictions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Performance Evaluations of Noisy Approximate Quantum Fourier Arithmetic

The Quantum Fourier Transform (QFT) grants competitive advantages, especially in resource usage and circuit approximation, for performing arithmetic operations on quantum computers, and offers a potential route towards a numerical quantum-computational paradigm. In this paper, we utilize efficient techniques to implement QFT-based integer addition and multiplications. These operations are fundamental to various quantum applications including Shor’s algorithm, weighted sum optimization problems in data processing and machine learning and quantum algorithms requiring inner products. We carry out performance evaluations of these implementations based on IBM’s superconducting qubit architecture using different compatible noise models. We isolate the sensitivity of the component quantum circuits on both one-/two-qubit gate error rates, and the number of the arithmetic operands’ superposed integer states. We analyze performance, and identify the most effective approximation depths for quantum add and quantum multiply within the given context. We observe significant dependency of the optimal approximation depth on the degree of machine noise and the number of superposed states in certain performance regimes. Finally, we elaborate on the algorithmic challenges - relevant to signed, unsigned, modular and non-modular versions - that could also be applied to current implementations of QFT-based subtraction, division, exponentiation, and their potential tensor extensions. Here, we analyze performance trends in our results and speculate on possible future development within this computational paradigm.

97 MATHEMATICS AND COMPUTING↗

SU-E-T-442: Sensitivity of Quality Assurance Tools to Delivery Errors On a Magnetic Resonance-Imaging Guided Radiation Therapy (MR-IGRT) System

Purpose: To test the sensitivity of the quality assurance (QA) tools actively used on a clinical MR-IGRT system for potential delivery errors. Methods: Patient-specific QA procedures have been implemented for a commercially available Cobalt-60 MR-IGRT system. The QA tools utilized were a MR-compatible cylindrical diode-array detector (ArcCHECK) with a custom insert which positions an ionization chamber (Exradin A18) in the middle of the device, as well as an in-house treatment delivery verification program. These tools were tested to investigate their sensitivity to delivery errors. For the ArcCHECK and ion chamber, a baseline was established with a static field irradiation to a known dose. Variations of the baseline were investigated which included rotated gantry, altered field size, directional shifts, and different delivery time. In addition, similar variations were tested with the automated delivery verification program that compared the treatment parameters in the machine delivery logs to the ones in the plan. To test the software, a 3-field conformal plan was generated as the baseline. Results: ArcCHECK noted at least a 13% decrease in passing rate from baseline in the following scenarios: gantry rotation of 1 degree from plan, 5mm change in field size, 2mm lateral shift, and delivery time decrease. Ion chamber measurements remained consistent for these variations except for the 5 second decrease in delivery time scenario which resulted in an 8% difference from baseline. The delivery verification software was able to detect and report the simulated errors such as when the gantry was rotated by 0.6 degrees, the beam weighting was changed by a percent, a single multileaf collimator was moved by 1cm, and the dose was changed from 2 to 1.8Gy. Conclusion: The results show that the current tools used for patient specific QA are capable of detecting small errors in RT delivery with presence of magnetic field.

60 APPLIED LIFE SCIENCES↗

THE INFLUENCE OF SPATIAL RESOLUTION ON NONLINEAR FORCE-FREE MODELING

The nonlinear force-free field (NLFFF) model is often used to describe the solar coronal magnetic field, however a series of earlier studies revealed difficulties in the numerical solution of the model in application to photospheric boundary data. We investigate the sensitivity of the modeling to the spatial resolution of the boundary data, by applying multiple codes that numerically solve the NLFFF model to a sequence of vector magnetogram data at different resolutions, prepared from a single Hinode/Solar Optical Telescope Spectro-Polarimeter scan of NOAA Active Region 10978 on 2007 December 13. We analyze the resulting energies and relative magnetic helicities, employ a Helmholtz decomposition to characterize divergence errors, and quantify changes made by the codes to the vector magnetogram boundary data in order to be compatible with the force-free model. This study shows that NLFFF modeling results depend quantitatively on the spatial resolution of the input boundary data, and that using more highly resolved boundary data yields more self-consistent results. The free energies of the resulting solutions generally trend higher with increasing resolution, while relative magnetic helicity values vary significantly between resolutions for all methods. All methods require changing the horizontal components, and for some methods also the vertical components, of the vector magnetogram boundary field in excess of nominal uncertainties in the data. The solutions produced by the various methods are significantly different at each resolution level. We continue to recommend verifying agreement between the modeled field lines and corresponding coronal loop images before any NLFFF model is used in a scientific setting.

79 ASTRONOMY AND ASTROPHYSICS↗

Low-pass spectral analysis of time-resolved serial femtosecond crystallography data

Low-pass spectral analysis (LPSA) is a recently developed dynamics retrieval algorithm showing excellent retrieval properties when applied to model data affected by extreme incompleteness and stochastic weighting. In this work, we apply LPSA to an experimental time-resolved serial femtosecond crystallography (TR-SFX) dataset from the membrane protein bacteriorhodopsin (bR) and analyze its parametric sensitivity. While most dynamical modes are contaminated by nonphysical high-frequency features, we identify two dominant modes, which are little affected by spurious frequencies. The dynamics retrieved using these modes shows an isomerization signal compatible with previous findings. We employ synthetic data with increasing timing uncertainty, increasing incompleteness level, pixel-dependent incompleteness, and photon counting errors to investigate the root cause of the high-frequency contamination of our TR-SFX modes. By testing a range of methods, we show that timing errors comparable to the dynamical periods to be retrieved produce a smearing of dynamical features, hampering dynamics retrieval, but with no introduction of spurious components in the solution, when convergence criteria are met. Using model data, we are able to attribute the high-frequency contamination of low-order dynamical modes to the high levels of noise present in the data. Finally, we propose a method to handle missing observations that produces a substantial dynamics retrieval improvement from synthetic data with a significant static component. Reprocessing of the bR TR-SFX data using the improved method yields dynamical movies with strong isomerization signals compatible with previous findings.

59 BASIC BIOLOGICAL SCIENCES↗

Design of a Particle Shadow-graph Velocimetry and Size (PSVS) System to Determine Particle Size and Density Distributions in Hanford Nuclear Tank Wastes - 12280

Accurate particle size and density distributions for nuclear tank waste materials are essential information that helps determine the engineering requirements for a host of waste management unit operations (e.g., tank mixing, pipeline transport, and filtration). The most prevalent approach for determining particle size and density distribution is highly laborious and involves identifying individual particles using scanning electron microscope/x-ray diffraction and then acquiring the density of the materials from the technical literature. Other methods simply approximate individual particle densities by assuming chemical composition, rather than obtaining actual measurements of particle density. To overcome these limitations, a Particle Shadow-graph Velocimetry and Size (PSVS) system has been designed to simultaneously obtain particle size and density distributions for a broad range of Hanford tank waste materials existing as both individual particles and agglomerates. The PSVS system uses optical hardware, a temperature-controlled settling column, and particle introduction chamber to accurately and reproducibly obtain images of settling particles. Image analysis software provides a highly accurate determination of both particle terminal velocity and equivalent spherical particle diameter. The particle density is then calculated from Newton's terminal settling theory. The PSVS system was designed to accurately image particle/agglomerate sizes between 10 and 1000 μm and particle/agglomerate densities ranging from 1.4 to 11.5 g/cm{sup 3}, where the maximum terminal velocity does not exceed 10 cm/s. Preliminary testing was completed with standard materials and results were in good agreement with terminal settling theory. Recent results of this method development are presented, as well as experimental design. The primary goal of these PSVS system tests was to obtain accurate and reproducible particle size and velocity measurements to estimate particle densities within 20 percent of direct measured density values. The average percent error observed in particle densities was 4.8, 8.2, and 25.8 percent for S1D3 (high-density soda-lime glass), S3D4 (zirconia), and S1D2 (soda-lime glass) beads, respectively. The maximum measured particle density error observed was 14.5, 21.0, and 58.4, for S1D3, S3D4, and S1D2 beads, respectively. Multiple sources of error can exist that contribute to inaccurate estimates of particle density using the PSVS approach. Two significant influences observed were thermal convective currents in the settling column fluid and non-spherical (irregular) particle shapes in the standard test materials. Experimental results using buoyant beads suggest thermal convective currents can influence the movement of settling particles as much as 4 mm/s. These thermal convective currents are clearly a significant concern for smaller and less-dense particles/agglomerates which have terminal velocities of the same magnitude. Significant effort went into the design and fabrication of a thermal control system for the PSVS settling column. However, small temperature variations (<0.3 deg. C) are difficult to prevent and measure accurately. Therefore, although designing the thermal control system was necessary, it is not considered the only solution to minimize error due to thermal convective currents. The use of small diameter (10 to 27 μm) polyethylene buoyant beads (in low concentrations) during actual settling experiments may be necessary to provide insight into particle-particle interactions and fluid velocity correction factors to account for potential influences from thermal convective currents. Future testing will incorporate the buoyant beads into the analysis technique when the suspension fluid is chemically compatible. The use of the Newton's law to calculate particle/agglomerate densities assumes spherical particle shapes. As the actual particle/agglomerates diverge from spherical, the margin of error increases. The selection of high quality (in density and shape) monodispersed particle standards was a direct attempt to reduce the uncertainties associated with non-spherical or irregular particles and to only observe the PSVS method and analysis error. While investigating the source of data scatter for the S1D3 bead (nominal 700 μm) standard, significant irregular particles where discovered. Yet, a subsequent investigation into the S3D4 bead standard was also conducted and it was determined that 60 percent of the particles had a 0.9 to 0.8 centricity, 32 percent were between 0.8 and 0.7, only 7 percent were between 1.0 and 0.9, and the remaining 1 percent of the particles had centricities between 0.7 and 0.6. Contrast this with the S1D3 bead standard, where 100 percent of particles had centricities between 0.95 and 0.98, upon applying the centricity filter. The influence of the non-spherical shape of the S3D4 bead standard is evident when comparing a 3.9 percent average density error for S1D3 glass bead standard with an 8.3 percent average density error for the S3D4 bead standard. Model corrections for non-spherical shape must be implemented to account for these measurement errors during future method validation and system performance assessments. In addition, further work is needed to resolve the higher than expected velocities for the smaller S1D2 particles. Initial measurements conducted with buoyant beads as fluid velocity tracers indicate that fluid velocities can be subtracted from the increased particle velocities to determine the particle terminal velocity, regardless of the surrounding fluid velocity. However, this approach is in its infancy and will need to be carefully and methodically validated. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

New determination of the N-{Delta}(1232) axial form factors from weak pion production and coherent pion production off nuclei at T2K and MiniBooNE energies revisited

We re-evaluate our model predictions in Phys. Rev. D 79, 013002 (2009) for different observables in neutrino induced coherent pion production. This comes as a result of the new improved fit to old bubble chamber data of the dominant axial C{sub 5}{sup A} nucleon-to-Delta form factor. We find an increase of 20%{approx}30% in the values for the total cross sections. Uncertainties induced by the errors in the determination of C{sub 5}{sup A} are computed. Our new results turn out to be compatible within about 1{sigma} with the former ones. We also stress the existing tension between the recent experimental determination of the {sigma}(CCcoh{pi}{sup +})/{sigma}(NCcoh{pi}{sup 0}) ratio by the SciBooNE Collaboration and the theoretical predictions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Topographic Effects on Radiation in the WRF Model with the Immersed Boundary Method: Implementation, Validation, and Application to Complex Terrain

Abstract Topographic effects on radiation, including both topographic shading and slope effects, are included in the Weather Research and Forecasting (WRF) Model, and here they are made compatible with the immersed boundary method (IBM). IBM is an alternative method for representing complex terrain that reduces numerical errors over sloped terrain, thus extending the range of slopes that can be represented in WRF simulations. The implementation of topographic effects on radiation is validated by comparing land surface fluxes, as well as temperature and velocity fields, between idealized WRF simulations both with and without IBM. Following validation, the topographic shading implementation is tested in a semirealistic simulation of flow over Granite Mountain, Utah, where topographic shading is known to affect downslope flow development in the evening. The horizontal grid spacing is 50 m and the vertical grid spacing is approximately 8–27 m near the surface. Such a case would fail to run in WRF with its native terrain-following coordinates because of large local slope values reaching up to 55°. Good agreement is found between modeled surface energy budget components and observations from the Mountain Terrain Atmospheric Modeling and Observations (MATERHORN) program at a location on the east slope of Granite Mountain. In addition, the model captures large spatiotemporal inhomogeneities in the surface sensible heat flux that are important for the development of thermally driven flows over complex terrain.

54 ENVIRONMENTAL SCIENCES↗

Super Resolving Unrolled Neural Networks for Remote Sensing

In remote sensing systems, the capabilities of the system are constrained by the complex interactions between size, weight, and power (SWAP) of potential designs. In electro-optical (EO) systems, examples of these critical parameters include the system’s sensitivity and resolution. Those parameters can be increased by ever larger optical apertures and focal planes but at the cost of more SWAP. Multi-image super resolution (MISR) techniques allow resolution to be enhanced via computation rather than more sophisticated optical hardware. These algorithms combine multiple images together into a single, higher resolution image, trading temporal resolution and computation for spatial resolution. Fielded MISR techniques, such as Drizzle, can require several hundred images to create a single super resolved image, implying reduced temporal resolution, increased data acquisition load, and limiting mission applications. Iterative techniques, such as model-based image reconstruction and compressive sensing, have been shown to create super resolved images using fewer images than Drizzle. They do this by posing an optimization problem that balances accuracy between a highly accurate physical model and an image model. In the case of super resolution, the physical model is defined by the relation between low resolution input images and the desired high resolution output image. The image model encodes some assumptions about the super resolved image. These assumptions are meant to suppress reconstruction artifacts that arise due to deterministic physical model error, stochastic measurement noise, and potential undersampling. In practice, the performance of iterative methods are limited by imaging models compatible with optimization. Deep learning-based methods can effectively learn image models of arbitrary complexity, but lack the theoretical explainability and robustness of iterative techniques. Consensus equilibrium (CE) generalizes the iterative techniques beyond optimization, enabling blackbox algorithms such as traditional and neural image denoisers to be used as the image model. CE-based approaches retain much of the explainability and robustness of iterative techniques while allowing the expressiveness of machine learning image models to be used. Additionally, by unrolling iterations of CE with an embedded image denoiser, the image denoiser can be further trained and specialized to the specific application with potentially higher quality reconstructions. Under this project, we demonstrated the feasibility of training an unrolled neural network based upon CE. While we didn’t train one, we showed that the CE process is differentiable and its gradient can be tractably computed. We also explored the usage of a variants of CE akin to generative neural works. Most importantly, we applied the CE framework to a number of problems including non-blind deconvolution, upsampling, single-image super resolution, MISR, event-based sensing, and saturated deconvolution. Our MISR prototype creates high quality reconstructions with an order of magnitude fewer images than previous approaches and, critically, produces these reconstructions fast enough for practical usage.

47 OTHER INSTRUMENTATION↗

Lieb-Mattis States for Robust Entangled Differential Phase Sensing

We explore a two-node, entanglement-enhanced sensor network for differential phase sensing that exploits decoherence-free subspaces to suppress common-mode noise, a primary limitation of many state-of-the-art quantum sensors. We identify a class of entangled states that, while not strictly optimal, achieve the same asymptotic sensitivity scaling as optimal states and can be prepared efficiently from initially unentangled atomic ensembles. Importantly, the preparation time decreases with increasing system size, which makes the states compatible with realistic noise processes in present-day quantum sensors that operate with large particle numbers but lack full error correction. We illustrate these ideas using two cavity-mediated preparation protocols: (i) coherent, unitary entanglement generation analogous to bosonic two-mode squeezing, yielding Heisenberg scaling, and (ii) dissipative preparation through collective emission into a shared cavity mode, providing a square-root improvement beyond the standard quantum limit. Numerical simulations show that both approaches remain effective at experimentally realistic cavity cooperativities, establishing a practical path toward scalable, quantum-enhanced differential phase sensing.

Kaubruegger, Raphael [National Institute of Standa↗

Liquid and Gamma-BCC Phase Equilibria in the Uranium-Niobium System: A Simple Thermodynamic Model for Phase Diagram and Other Predictions

A simple thermodynamic model for the uranium-niobium (U-Nb) system was created using a Calphad-type approach, circa 2002. Only the liquid and gamma-BCC phases were modeled, with their subregular solution mixing terms optimized by trial and error. The custom (user-defined) database file (.tdb) and experimental data file (.exp) are listed, both of which are compatible with Thermo-Calc software. This model is used to calculate the solidus, liquidus, miscibility gap on the U-Nb phase diagram and also the enthalpy of melting in the U-6Nb alloy.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Coupling Measurements in ATF2 Extraction Line

The purpose of ATF2 is to deliver a beam with stable very small spotsizes as required for future linear colliders such as ILC or CLIC. To achieve that, precise controls of aberrations such as dispersion and coupling are necessary. Theoretically, the complete reconstruction of the beam matrix is possible from the measurements of horizontal, vertical and tilted beam sizes, combining skew quadrupole scans at several wire-scanner positions. Such measurements were performed in the extraction line (EXT) of ATF2 in May 2009. We present analysis results attempting to resolve the 4 x 4 beam matrix. We aimed to reconstruct the full beam matrix using only skew quadrupole scans at different EXT wire-scanner locations, with measurements of horizontal, vertical and two tilted beam size projections. Checking the coherence of the {sigma}{sub 13} reconstruction from the {sigma}{sub 80{sup o}} and the {sigma}{sub 100{sup o}} measurements was essential to perform this analysis. We have shown that reconstruction of the coupling element can not be performed independantly of the 4 x 4 diagonal ones since it leads to unphysical results. A more accurate and automatisable method was find, leading to physical beam matrix reconstruction, compatible with the measurements. Another analysis should be performed based on a larger number of data sets to minimise statistical errors.

43 PARTICLE ACCELERATORS↗