The Octavius1500 2D ion chamber array and its associated phantoms: Dosimetric characterization of a new prototype

Purpose: The purpose of the study is to characterize the prototype of the new Octavius1500 (PTW, Freiburg, Germany) 2D ion chamber array, covering its use in different phantom setups, from the most basic solid water sandwich setup to the more complex cylindrical Octavius{sup ®} 4D (Oct4D) (PTW) phantom/detector combination. The new detector houses nearly twice the amount of ion chambers as its predecessors (Seven29 and Octavius729), thereby tackling one of the most important limitations of ion chamber (or diode) arrays, namely the limited detector density. The 0.06 cm{sup 3} cubic ion chambers are now arranged in a checkerboard pattern, leaving no lines (neither longitudinally nor laterally) without detectors. Methods: All measurements were performed on a dual energy (6 MV and 18 MV) iX Clinac (Varian Medical Systems, Palo Alto, CA) and all calculations were done in the Eclipse treatment planning system (Varian) with the Anisotropic Analytical Algorithm. First, the basic characteristics of the 2D array, such as measurement stability, dose rate dependence and dose linearity were investigated in the solid water sandwich setup. Second, the directional dependence was assessed to allow the evaluation of the new Octavius2D phantom (Oct2D{sup 1500}) for planar verification measurements of composite plans. Third, measurements were performed in the Oct4D phantom to evaluate the impact of the increased detector density on the accuracy of the volumetric dose reconstruction. Results: While showing equally good dose linearity and dose rate independence, the Octavius1500 outperforms the previous models because of its instantaneous measurement stability and its twofold active area coverage. Orthogonal field-by-field measurements immediately benefit from the increased detector density. The 3.9 cm wide compensation cavity in the new Oct2D{sup 1500} phantom prototype adequately corrects for directional dependence from the rear, resulting in good agreement within the target dose. Discrepancies may arise towards the sides of the array because of uncompensated lateral beam incidence. The beneficial impact of the detector density is most prominent in the Oct4D system, for which the average pass rate (PR) is now nearly 100% (99.31 ± 0.37) when using gamma criteria of 2%G,2 mm (10% dose threshold). In search of gamma analysis criteria that are not too lenient to detect possibly relevant deviations, the authors conclude that for our radiotherapy environment, the authors choose to adopt 3%L,3 mm PR97% (threshold 10%) criteria for the Oct2D{sup 1500}/Octavius1500 system and 2%L,3 mm PR97% (threshold 10%) for the Oct4D/Octavius1500 system. These are first line pass/check criteria and plans that fail are not necessarily rejected, but submitted to a more detailed investigation. Conclusions: When irradiated from the front, the Octavius1500 array has two main advantages over its 729 predecessors: its instantaneous measurement stability and-–most importantly—its twofold detector density. In the Oct2D1500 phantom, these advantages are counterbalanced by the more pronounced directional dependence. The measurement-based 3D dose reconstruction in the Oct4D system, however, benefits considerably from the higher detector density in the checkerboard panel design.

07 ISOTOPE AND RADIATION SOURCES↗

Review of Artificial Abrasion Test Methods for PV Module Technology

This review is intended to identify the method or methods--and the basic details of those methods--that might be used to develop an artificial abrasion test. Methods used in the PV literature were compared with their closest implementation in existing standards. Also, meetings of the International PV Quality Assurance Task Force Task Group 12-3 (TG12-3, which is concerned with coated glass) were used to identify established test methods. Feedback from the group, which included many of the authors from the PV literature, included insights not explored within the literature itself. The combined experience and examples from the literature are intended to provide an assessment of the present industry practices and an informed path forward. Recommendations toward artificial abrasion test methods are then identified based on the experiences in the literature and feedback from the PV community. The review here is strictly focused on abrasion. Assessment methods, including optical performance (e.g., transmittance or reflectance), surface energy, and verification of chemical composition were not examined. Methods of artificially soiling PV modules or other specimens were not examined. The weathering of artificial or naturally soiled specimens (which may ultimately include combined temperature and humidity, thermal cycling and ultraviolet light) were also not examined. A sense of the purpose or application of an abrasion test method within the PV industry should, however, be evident from the literature.

14 SOLAR ENERGY↗

Verification and Validation of a Three-Dimensional Composite Impact Model with Tabulated Input

A material model which incorporates several key capabilities which have been identified by the aerospace community as lacking in the composite impact models currently available in the commercial transient dynamic finite element code LS-DYNA® has been developed. The material model utilizes experimentally based tabulated input to define the evolution of plasticity and damage as opposed to specifying discrete input parameters (such as modulus and strength. The plasticity portion of the orthotropic, three-dimensional, macroscopic composite constitutive model is based on an extension of the Tsai-Wu composite failure model into a generalized yield function with a non-associative flow rule. The capability to account for the rate and temperature dependent deformation response of composites has also been incorporated into the material model. For the damage model, a strain equivalent formulation is utilized to allow for the uncoupling of the deformation and damage analyses. In the damage model, a diagonal damage tensor is defined to account for the directionally dependent variation of damage. However, the terms in the damage matrix are semi-coupled such that the damage in a particular coordinate direction is a function of the stresses and plastic strains in all of the coordinate directions. For the failure model, a tabulated approach is utilized in which a stress or strain based invariant is defined as a function of the location of the current stress state in stress space to define the initiation of failure, which allows an arbitrarily shaped failure surface to be defined. A systematic series of validation and verification studies, at a variety of length scales ranging from single element simulations to simulations of a flat panel impact test, have been performed to fully exercise and evaluate the capabilities of the developed model.

Impact↗

Advanced manufacturing development of a composite empennage component for L-1011 aircraft. Phase 3: Production readiness verification testing

Twenty-two specimens of each of two key structural elements of the Advance Composite Vertical Fin (ACVF) were fabricated and tested. One element represented the front spar at the fuselage attachment area and the other element represented the cover at the fuselage joint area. Ten specimens of each element were selected for static testing. The coefficient of variation resulting from the tests was 3.28 percent for the ten cover specimens and 6.11 percent for the ten spar specimens, which compare well with metallic structures. The remaining twelve cover and twelve spar specimens were durability tested in environmental chambers which permitted the temperature and humidity environment to be cycled as well as the applied loads. Results of the durability tests indicated that such components will survive the service environment.

Jackson, A.↗

Magnification Determination for AGHCF Metallographic Images

Metallographic images generated in the Alpha Gamma Hot Cell Facility (AGHCF) have been used for quantitative and qualitative characterization of irradiated metallic fuel pins. Individual high-magnification images (micrographs) contained in AGHCF file folders and experimental notebooks are in the form of polaroid photographs labeled with AGHCF identification number, magnification, and surface condition (as-polished or etched). Low magnification composite images (photomosaics) are also available for fuel cross sections, for radial strips from the fuel center to the cladding outer diameter, and for circumferential strips of the cladding and outer fuel region. The individual images do not have scale bars. Only a few of the composite images contain scale bars. The purpose of this work is to describe and apply methods for checking the magnification (50X to 500X) of individual images and for determining the magnification (~25X to ~100X) of composite images. The metallographic images used to verify and/or determine magnification were generated during the 1989 to 1993 timeframe for cross sections of U-10Zr/HT9 fuel rods irradiated in EBR-II and for cross sections of irradiated U-10Zr/HT9 fuel-rod samples following elevated-temperature tests conducted in the out-of-pile AGHCF Fuel Behavior Test Apparatus (FBTA). Procedures are documented in the AGHCF Operations Manual for preparation of metallographic samples, for calibration verification, and for constructing composites from individual images. Calibration verification of magnification was performed at least semiannually. One standard used for calibration verification was a glass slide with vertical lines indicating distances of 1 mm, 0.1 mm and 0.01mm. Guidance is provided in the current work for determining magnification from images of the standard. In addition to the periodic calibration verification, consistency checks are recommended to verify the magnification of images taken between the routine calibration verifications. For cladding samples with or without significant fuel-cladding chemical interaction (FCCI), images taken at different magnifications (e.g., 150X and 200X) of the unaffected cladding thickness can be compared. This process is independent of changes in cladding thickness due to swelling and creep. For images taken at only one magnification of cladding regions with no FCCI, the cladding thickness determined from the images may be compared to the nominal as-built cladding thickness (15.0 ± 0.5 mils for examples used in current work)). This procedure works best for cladding that has not experienced significant swelling and/or creep (e.g., ≤2% circumferential strain at the cladding outer surface). Composite images were constructed by pasting together higher magnification images and photographing the composite to generate a negative from which the hard-copy photograph was developed. The primary purpose of the composite images was to identify interesting areas of the fuel and cladding for imaging at higher magnification. However, procedures are recommended in the current work for determining composite magnifications to allow quantitative characterization of the fuel. Composites are not recommended for determining cladding thickness or FCCI depth because magnifications are too low (generally ≤110X) and image contrast is low. Fuel cross-section composites were created by pasting together 50X or 75X images. The nominal magnification for the photographed fuel cross-section composites is 25.4X. A more precise magnification can be determined by comparing the average cladding outer diameter measured from the composite to the average cladding outer diameter measured by profilometry. Radial-strip composites were constructed by pasting together high-magnification (150X or 250X) images. The nominal magnification of radial-strip composites photographs is about 100X. A more precise method for determining the magnification of radial strips is to compare the cladding thick

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Design and manufacturing concepts for thermoplastic structures

Results to date on the application of two manufacturing techniques, fiber placement and single diaphragm/coconsolidation, to produce cost-effective, thermoplastic composite (TPC), primary fuselage structure are presented. Applications relative to fuselage upper cover structure indicate potential cost savings relative to conventional approaches. Progress is also presented on efforts concerned with other design details which take advantage of thermoplastic composites such as fastener less stiffener/frame attachments. In addition, results are presented on the development and verification testing of a composite lug analysis program which incorporates through-the-thickness effects.

Renieri, Michael P.↗

SU-E-T-40: Analysis of Composite MVCT Planning Dosimetry with SBRT of Upper Peripheral Lung Cancer

Purpose: Quantitatively evaluate and compare the final adaptive planning doses of upper peripherally located lung SBRT treated with Tomotherapy using 3rd party software tool. Methods: With tumor located in the upper quadrant of lung, a 3rd party software tool was implemented to evaluate the Tomotherapy composite dosimetry created by adaptive fan beam MVCT images described by RTOG 0915 dose criteria (48 Gy / 4 fractions). The composite doses was then summarized with deformable registration in this package with corresponding target and critical structures. The final dosimetry variation, both for target and critical structures, were evaluated in a tabular format and isodose distribution comparisons. Results: Composite SBRT treatment doses were evaluated with adaptive planning. The PTV and several critical structures were mapped/deformed into the package via DICOM from Tomotherapy after the final composite doses were created. Initial plan versus the final composite plan calculated from verification images were compared. The ITV defined by 4D CT and contoured on MVCT images were correlated in patient repositioning. Final composite dose calculated for PTV coverage has shown 0.1–0.17 cGy coverage (0.2–0.4% of prescription dose) variation. Total lung and cord were both less than 0.17 Gy which represented <0.4% difference. All other critical structure were within statistical significance. The adaptive plans justified/included the breathing and motion during the treatment process. Final 95% isotope line coverage from prescription has been met without issues. Conclusions: With lung tumor location in the upper peripheral area, breathing control was not necessary required during SBRT treatment using Tomotherapy technique. Slow fan beam CT provides definitive ITV information and the adaptive composite plan for all fractions were suitable for final dose delivery. The final composite dose calculated with Tomotherapy adaptive tool indicated that the composite dosimetry justified the target location with SBRT delivery, safe with minimum margin of errors.

60 APPLIED LIFE SCIENCES↗

Spectroscopic fast neutron transmission imaging in a treaty verification setting

Measurements of the geometric configuration of objects and their material composition are needed for nuclear treaty verification purposes. We experimentally demonstrate a simple method based on monoenergetic fast neutron transmission to realize crude imaging of the geometric configuration of special nuclear material, confirm its fissionable content, and obtain information on its approximate fissile mass. In the experiment, we used monoenergetic neutrons from D(d, n)3He and T(d, n)4He reactions and a linear array of liquid scintillation detectors to perform spectroscopic neutron imaging of up to 13.7 kg of highly enriched uranium in a spherical geometry. We also show an example of detection of material diversion and confirm the presence of fissionable material based on the measurement of high-energy prompt fission neutrons, including estimating the quantity of material from the comparison of measured and predicted fission neutron emission rate. The combination of crude imaging and fissionable material detection and quantification in a simple approach may be attractive in certain treaty verification scenarios.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

C/SiC Component & Material Analysis, Attachment Verification, & Blisk Turbopump Testing

Ceramic composite blisk components constructed of carbon fibers & silicon carbide ceramic matrix have been fabricated and tested. Room and cryogenic torque testing have verified the attachment configuration. The polar and quasi-isotropic blisks have been proof spun, balanced, and tested in the Simplex turbopump. Foreign particle impact analysis was conducted for C/SiC. Data and manufacturing lessons learned are significantly benefiting the development of the Reusable Launch Vehicle's ceramic matrix composite integrally bladed disk.

Effinger, Michael R.↗

Ultrasonic verification of five wave fronts in unidirectional graphite epoxy composite

The existence of five different waves fronts in a unidirectional graphite fiber reinforced epoxy composite with energy flux propagation at the angle of 60 deg with respect to the fiber direction is verified by measuring their corresponding group and phase velocities of longitudinal and shear waves using the through transmission technique. The experimental and theoretical values of phase velocities show excellent agreement for all three modes of wave propagation. It is also verified that the maximum output voltage amplitude is obtained when the line joining the centers of the transmitting and receiving transducers is parallel to the energy propagation direction defined by the deviation angle.

Seng, Han-Song↗

Analytical modeling and sensor monitoring for optimal processing of polymeric composite material systems

Process simulation models and cure monitoring sensors are discussed for use in optimal processing of fiber-reinforced composites. Analytical models relate the specified temperature and pressure cure cycle to the thermal, chemical, and physical processes occurring in the composite during consolidation and cure. Frequency-dependent electromagnetic sensing (FDEMS) is described as an in situ sensor for monitoring the composite curing process and for verification of process simulation models. A model for resin transfer molding of textile composites is used to illustrate the predictive capabilities of a process simulation model. The model is used to calculate the resin infiltration time, fiber volume fraction, resin viscosity, and resin degree of cure. Results of the model are compared with in situ FDEMS measurements.

Loos, Alfred C.↗

Applications of Materials Selection For Joining Composite/Alloy Piping Systems

A study in collaboration between investigators at Southern University and Louisiana State University in Baton Rouge, Louisiana and NASA/MSFC is examining materials for modeling and analysis of heat-activated thermal coupling for joining composite to composite/alloy structures. The short-term objectives of this research are to develop a method for joining composite or alloy structures, as well as to study the effects of thermal stress on composite-to-alloy joints. This investigation will result in the selection of a suitable metallic alloy. Al-Li alloys have potential for this purpose in aerospace applications due to their excellent strength-to-weight ratio. The study of Al-Li and other alloys is of significant importance to this and other aerospace as well as offshore related interests. Further research will incorporate the use of computer aided design and rapid prototype hardware for conceptual design and verification of a potential composite piping delivery system.

Crosby, Karen E.↗

METCAN verification status

The status of the verification (comparisons of predictions with experimental data) of the METCAN (METal-matrix Composite ANalyzer) code at high temperature is summarized. Verification includes select available room temperature of W/Cu composites for different fiber volume ratios. It also includes high temperature properties for thermal expansion, moduli, strength and stress/strain behavior for SiC/Ti composites. Furthermore it includes limited cases for thermal fatigue strength degradation. The verification results summarized herein indicate that METCAN simulates complex high temperature metal matrix composite bahavior with reasonable accuracy and that it can be used with confidence to identify in-situ nonlinear behavior that influences composite properties.

Chamis, Christos C.↗

Development of an advanced composite aileron for the L-1011 transport aircraft

Significant improvements in structural efficiency can be achieved by the utilization of advanced composites for construction of aircraft secondary structures. Careful evaluation of alternate designs and materials for the L-1011 advanced composite inboard aileron has led to the selection of several unique material combinations and easily manufactured structural configurations. The advanced composite aileron is a direct replacement for the metal aileron with a weight savings of 23 percent. Due to the configurational simplicity of the components within the composite aileron, and because it contains 50 percent fewer parts and fasteners than the metal aileron, it is predicted that the composite aileron will be cost competitive with the metal aileron in a production environment. Structural analysis of the composite aileron, in conjunction with the design data, concept verification, and ground tests, indicates that the composite aileron design meets or exceeds structural requirements.

Griffin, C. F.↗

Hydration of C{sub 3}S thin films

Thin films of C{sub 3}S of a few tens of nanometers were produced by electron beam evaporation. After verification that the chemical composition of the bulk material remained unchanged, the samples were hydrated with water vapor in a reaction chamber under saturated pressure and temperature conditions, and were kept isolated from atmospheric exposure throughout the whole duration of the experiment. Analyses by X-ray photoelectron spectroscopy at different stages of hydration evidence a shift of the Si peaks to higher energies and a subsequent decrease of the Ca-Si binding energy distance, indicating silicate polymerization expected upon formation of C-S-H. The measured molar Ca/Si ratio evolves from that of a jennite-like material, of about 1.55, at the beginning of the experiment (attributed to pre-hydration of the thin films), to a tobermorite-like ratio of 0.85 after 3 h of hydration.

36 MATERIALS SCIENCE↗

In-situ x-ray monitoring of damage accumulation in SiC/RBSN tensile specimens

The room-temperature tensile testing of silicon carbide fiber reinforced reaction-bonded silicon nitride (SiC/RBSN) composite specimens was monitored by using in-situ x ray film radiography. Radiographic evaluation before, during, and after loading provided data on the effect of preexisting volume flaws (high density impurities, and local density variations) on the fracture behavior of composites. Results from (0)1, (0)3, (0)5, and (0)8 composite specimens, showed that x ray film radiography can monitor damage accumulations during tensile loading. Matrix cracking, fiber-matrix debonding, and fiber pullout were imaged throughout the tensile loading history of the specimens. Further, in-situ film radiography was found to be a helpful and practical technique for estimating interfacial shear strength between the SiC fiber and the RBSN matrix by the matrix crack spacing method. It is concluded that pretest, in-situ, and post-test radiography can provide for a greater understanding of ceramic matrix composite mechanical behavior, a verification of related experimental procedures, and a validation and development of related analytical models.