Search NASA⌕ Search

SEARCH · Search NASA

Results for “Cs removal”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Cesium Removal from SY-101 Tank Waste Using Crystalline Silicotitanate

The newly operational Tank Side Cesium Removal (TSCR) system removes radioactive cesium-137 ( 137 Cs) and solids from tank waste supernate in the 200 east area of the Hanford site. Efforts to expand the removal capabilities to the 200 west area are underway by a system anticipated to be called the West Area Risk Management (WARM) system. Laboratory-scale ion exchange processing using expected WARM unit operations were conducted to contribute toward Washington River Protection Solutions (WRPS) establishing accurate process flowsheets for the individual feed campaigns planned for the west area supernate pretreatment. This report describes the small-scale ion exchange testing with 8.0 L of filtered supernate from tank 241-SY-101 (referred to as SY-101) at 16 °C (62 °F) to demonstrate processing conditions that would be prototypic of what the WARM system may experience. One of the waste acceptance criteria (WAC) for the Waste Treatment Plant (WTP) Low-Activity Waste Facility is that the waste must contain less than 3.18×10 -5 Ci 137 Cs per mole of Na. For the SY-101 tank waste to meet this criterion, only 0.44% of the influent 137 Cs concentration may be delivered to the WTP; this requires a Cs decontamination factor of 227. Testing with SY-101 matched current TSCR prototypic operations where a lead-lag configuration is used until the lag column reached the WAC limit. Neither the lead nor lag columns reached the WAC, so a polish column was never utilized during this test. Feed was processed at 1.9 bed volumes (BVs) per hour; the flowrate, in terms of contact time with the crystalline silicotitate (CST) bed, matched the current flowrate at TSCR (an expected flowrate to be used at WARM). The lead column only reached 0.09% Cs breakthrough after processing ~1363 BVs of feed. Cesium breakthrough from the lag column was not observed during the entire processing. Table S.1 and Figure S.1 summarize the observed column performance and relevant Cs loading characteristics. Table S.1 and Figure S.1 also summarize the measured SY-101 Cs load performance.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Reduced Temperature Cesium Removal from AP-101 Using Crystalline Silicotitanate

The Tank Side Cesium Removal (TSCR) system, currently operational under Washington River Protection Solutions LLC (WRPS), sends initial low-activity Hanford waste tank supernate feed to the Hanford Waste Treatment and Immobilization Plant (WTP) Low-Activity Waste (LAW) Facility. In addition to entrained solids removal from the supernate, the primary goal of TSCR is to remove cesium-137 ( 137 Cs) by ion exchange, allowing contact handling of the liquid effluent product at the WTP. Crystalline silicotitanate (CST) ion exchange media, manufactured by Honeywell UOP, LLC (product IONSIV™ R9140-B), was selected as the ion exchange media at TSCR. Laboratory-scale ion exchange processing using TSCR prototypic unit operations continues to contribute toward WRPS establishing accurate process flowsheets for the individual feed campaigns planned for TSCR. This report describes the small-scale ion exchange testing with 14.0 L of diluted and filtered supernate from tank 241-AP-101 (AP-101DF) at 16 °C (62 °F) to demonstrate processing at temperature conditions that are more prototypic of what the TSCR system could experience during colder seasons of the year. Since CST Cs capacity increases with decreasing contact temperature, testing at the lower operating temperature will help to predict the maximum 137 Cs loading onto the CST in the TSCR system. One of the waste acceptance criteria (WAC) for the WTP Low-Activity Waste Facility is that the waste must contain less than 3.18×10 -5 Ci 137 Cs per mole of Na. For the AP-101DF tank waste to meet this criterion, only 0.144% of the influent 137 Cs concentration may be delivered to the WTP; this requires a Cs decontamination factor of 694. Testing with AP-101DF matched TSCR prototypic operations where a lead-lag configuration was used until the lag column reached the WAC limit, then a polish column was brought online for continued processing in a lead-lag-polish column configuration. Feed was processed at 1.9 bed volumes (BVs) per hour; the flowrate, in terms of contact time with the CST bed, matched the expected flowrate at TSCR. The Cs-decontaminated product was retained for vitrification testing (to be reported separately). The lead column reached 62% Cs breakthrough after processing ~1400 BVs of feed; the 50% Cs breakthrough occurred at 1250 BVs. Testing compared to previous AP-107 testing at 16 °C showed ~80 BV increases in volume processed to reach the WAC limit for both lead and lag columns. A similar slope in breakthrough curves for both tests indicates similar kinetic behavior, with variations in feed matrices (Na and Cs concentrations) likely responsible for the deviations in reaching the WAC limit. The Cs effluent from the lag column reached the WAC limit after processing 875 BVs. Anticipating this breakthrough point, the polish column was preemptively installed at 770 BVs. Cs breakthrough from the lag column began at 300 BVs, reaching 5.32×10 0 µCi/mL, or 5.6 % Cs breakthrough, after processing all 1400 BVs of feed. Table S.1 and Figure S.1 summarize the observed column performance and relevant Cs loading characteristics.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Cesium Removal from 5.5 and 7.0 M Na AP-105 Using Crystalline Silicotitanate

The Tank Side Cesium Removal (TSCR) system, currently operational by Washington River Protection Solutions LLC (WRPS), prepares initial low-activity Hanford waste tank supernate feeds for the Hanford Waste Treatment and Immobilization Plant (WTP) Low-Activity Waste (LAW) Facility. In addition to entrained solids removal from the supernate, the primary goal of TSCR is to remove cesium-137 ( 137 Cs) by ion exchange, allowing contact handling of the liquid effluent product at the WTP as governed by a waste acceptance criterion (WAC). Specific to 137 Cs, this requirement is < 3.18E-5 Ci 137 Cs/mole of Na. Crystalline silicotitanate (CST) ion exchange media, manufactured by Honeywell UOP, LLC (product IONSIVTM R9140-B), has been selected as the ion exchange media for TSCR. CST is a non-elutable inorganic material that has demonstrated robust chemical, physical, and radiation tolerance while maintaining functionality. However, testing to date on actual tank waste samples has been limited to Na concentrations between 5 and 6 M Na (Fiskum et al. 2019a, 2021b and Westesen et al. 2021a, 2021b, 2022) while actual tank conditions can reach upwards of 9 M Na. Testing with feed from Hanford tank AP-105 incorporated testing at both 5.5 and 7 M Na in order to evaluate the impact of Na concentration on volume of waste processed before reaching the WAC. A 6-L volume of 5.5 M Na AP-105 and an 8-volume of 7 M Na AP-105 was processed through the Radioactive Waste Test Platform system, established at Pacific Northwest National Laboratory to support small-scale waste qualification efforts. The columns consisted of 6- to 9-mL CST beds (CST Lot 2002009604, sieved to screen out >30-mesh particles) placed in 1.5-cm-inner-diameter columns. Feed was processed at 1.9 bed volumes (BV) per hour; the flowrate, in terms of contact time with the CST bed, matched the expected flowrate at TSCR. Table S.1 and Figure S.1 summarize the measured AP-105 Cs load performance for each feed condition.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Cesium Removal from AP-106 Tank Waste Using Crystalline Silicotitanate

The Tank Side Cesium Removal (TSCR) system, currently operated by Washington River Protection Solutions, LLC, prepares Hanford waste tank supernate feeds for the Low-Activity Waste Facility at the Hanford Waste Treatment and Immobilization Plant (WTP). In addition to entrained solids removal from the supernate, the primary goal of TSCR is to remove cesium-137 ( 137 Cs) by ion exchange (IX), allowing contact handling of the liquid effluent product at the WTP as governed by a waste acceptance criterion (WAC). Specific to 137 Cs, this requirement is <3.18E-5 Ci 137 Cs/mole of Na. Crystalline silicotitanate (CST), manufactured by Honeywell UOP, LLC (product IONSIV R9140-B), was selected as the ion exchange media for TSCR.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Options for the Removal of Cesium and Strontium from Acidic Uranyl Sulfate Solutions from Molybdenum-99 Production: Part II The Effect of Sodium Carbonate Adjustment to pH 9 on Strontium Removal

A small laboratory-scale column process aimed at removing fission products from prototypical acidic sulfate solution wastes from a prototypical Mo-99 recovery process has been operated in a radioactive materials hood at Savannah River National Laboratory. This equipment has been operated with realistic concentrations of uranium (0.4 wt % 235 U), plutonium ( 239 Pu), neptunium ( 237 Np), non-radioactive surrogates of common fission products (including Cs and Sr) and two promising absorbents – AMP-PAN and CST R9120-B. The goal of this work was to demonstrate the removal and concentration of high specific activity isotopes which are expected to dominate the classification of the low-level waste from the production of 99 Mo. Both AMP-PAN and CST R9120-B are attractive absorbents for the removal of 137 Cs from an acidic sulfate waste stream. They do not provide a solution for the removal of 90 Sr from the acidic solutions. CST was shown to be useful at removing both Cs and Sr after adjustment of the acidic sulfate solution with sodium carbonate to pH 9. Limited removal of transuranic species and almost no removal of uranium was observed for CST R9120B absorbent. This could be important due to the relatively large amount of uranium expected to be present in such waste streams. The capacity of these absorbents for 137 Cs will likely be dependent on the Cs concentration in the solutions processed but loading in excess of 0.7 mg Cs per gram of CST absorbent while loading 0.14 mg Sr per gram of CST absorbent appears to be achievable from pH 9 carbonate solution.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Influence of porous aluminosilicate grain size materials in experimental and modelling Cs + adsorption kinetics and wastewater column process

This paper focuses on the influence of the grain size of a geopolymer based adsorbent on its Cs + adsorption performances both in batch and fixed-bed process. The geopolymer phase was used as a binder to support NaY zeolite particle in a 20 wt% charged porous composite with 160 m 2 .g –1 of porous surface area. These samples were shaped with three grain sizes (50 /100/500 µm) to remove 80–90 mg/g of Cs + in batch and column operations. After their microstructural and porous characterizations, their efficiency and adsorption characteristics were investigated through adsorption isotherms and kinetic in the two processes. While the grain size has no influence on the maximal extraction capacity of the adsorbent, it strongly affects the sorption kinetic. By coupling experimental data and a modelling approach, the complex sorption mechanism was highlighted, suggesting a new insight of the contaminant sorption kinetic. Then, comparison of batch and column adsorption experiments illustrates the detailed explanation of various process parameters for column study. The results show challenges for fixed-bed column utilization by the choice of the appropriate grain size as a compromise between the material sorption kinetic and hydrodynamic considerations. Furthermore, this is of high importance to more accurately optimize the design of column adsorption to assess the transport of Cs+ in multi-porous tailored grain size materials.

36 MATERIALS SCIENCE↗

Characterization of CST Post-Processing AP-105 Hanford Tank Waste

The primary goal of the Tank Side Cesium Removal (TSCR) system, under development by Washington River Protection Solutions, LLC (WRPS), is to remove entrained solids and 137 Cs from the Hanford tank waste supernate to expedite production of low-activity waste. Ion exchange (IX) testing of 10.9 L of waste from Hanford tank 241-AP-105 (AP-105), performed by Pacific Northwest National Laboratory, used a lead-lag-polish column format, with a bed volume of 10 mL per column, to decontaminate tank waste supernate using crystalline silicotitanate (CST) as the IX media. The AP-105 Cs IX processing test, discussed elsewhere, resulted in a shorter transition zone (i.e., steeper load curve) than those defined by wastes from tanks 241-AP-107 and 241-AW-102.1 The shorter transition zone was indicative of a matrix effect retarding Cs capacity. Therefore, aliquots of spent CST from the lead, lag, and polish columns were subjected to a digestion protocol to quantify analytes retained by the CST and extrapolate the impact on Cs capacity. The spent CST was digested using a combination of 5 M HNO 3 and H 2 O 2 with vigorous heating and stirring. Due to the radiation dose accompanying the 137 Cs on the CST columns, a secondary Cs separation by ammonium molybdophosphate embedded in polyacrylonitrile (AMP-PAN) was performed to separate the 137 Cs from the CST so the samples could be contact-handled for analysis outside of a shielded facility.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of a three-man preprototype CO2 collection subsystem for spacecraft application

Future long-duration manned space missions will require regenerable carbon dioxide (CO2) collection concepts such as the Electrochemical Depolarized CO2 Concentrator (EDC). A three-man-capacity preprototype CO2 Collection Subsystem (CS-3) is being developed for eventual flight demonstration as part of the Air Revitalization System (ARS) of the Regenerative Life Support Evaluation (RLSE) experiment. The CS-3 employs an EDC to concentrate CO2 from the low partial-pressure levels required of spacecraft atmospheres to high partial-pressure levels needed for oxygen (O2) recovery through CO2 reduction processes. The CS-3 is sized to remove a nominal 3.0 kg/day (6.6 lb/day) of the CO2 to maintain the CO2 partial pressure (pCO2) of the cabin atmosphere at 400 Pa (3 mm Hg) or less. This paper presents the preprototype design, configuration, operation, and projected performance characteristics.

Schubert, F. H.↗

The Effects of Contaminant-Aging on Decontamination Efficacy for Rapid Remediation of Concrete Surfaces - 20412

Understanding the relationship between decontamination efficacy and contaminant aging is imperative for developing effective remediation strategies following a large-scale contamination event. Non-destructive decontamination of concrete following a contamination incident becomes more difficult with increased time between contamination and decontamination because contaminants may chemically bind to concrete and/or penetrate into the concrete subsurface. In this work, we evaluated the decontamination efficacy of two decontamination methods on concrete samples contaminated with soluble Cesium-137 (Cs-137) and silica particles with 0.5 μm and 2 μm diameters. Concrete samples were aged between 1 and 59 days, with half of the coupons receiving 1 mL of artificial rainwater about once every three days. After aging, coupons were either decontaminated or analyzed to determine contaminant penetration depths. Coupons were decontaminated with 0.1 M Potassium Chloride (KCI) solution applied either by flowing solution across the contaminated coupon face or non-destructive power washing. Contaminant depth profiles were created by removing the top surface of the coupon at least 15 times, measuring the activity in each removed layer, normalizing the total activity removed to the measured decontamination efficacy following the last layer removal, and determining the penetration thickness using the coupon dimensions, bulk density, and mass of material removed for each layer. Pressurized washing effectively removed particles, but not soluble cesium, despite the majority of Cs-137 being located within the first millimeter of the subsurface. Soluble cesium removal by flowing 0.1 M KCI solution across the contaminated surface dropped to less than 12% within the first ten days. This drop in Cs-137 removal efficacy occurred within the first five days for coupons experiencing artificial rainfall events. Flowing 0.1 M KCI solution across the contaminated face was ineffective at removing particles, likely because particles had localized in surface depressions. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Strontium Speciation in Relevant Tank Waste Components Examined by Electrospray Ionization Mass Spectrometry

The identification of chemical species formed in complex nuclear waste is crucial for the development and employment of advanced separations technologies to remediate the Hanford site by processing tank waste. The current Tank Side Cesium Removal (TSCR) process deployed at Hanford utilizes crystalline silicotitanate (CST) ion exchange (IX) media to aid in the separation of low-activity waste for proper treatment and disposal. The inorganic IX media is highly selective for Cs but has been shown to also remove Sr from caustic simulants and small-scale IX processing of Hanford tank waste.(Fiskum, Rovira et al. 2019, Fiskum, Campbell et al. 2021, Westesen, Campbell et al. 2022) Quantitative Sr removal has not been observed in all tank waste supernates tested; thus, to better understand Sr removal and effectively predict processing behavior through TSCR, it is necessary to first investigate Sr speciation in tank waste. This work utilized electrospray ionization mass spectrometry (ESI-MS) to identify ionic Sr complexes that form in the presence of NO 3 –, NO 2 –, OH–, and Cl–. Although our results show that NO 3 –, NO 2 –, and OH– are competitive for Sr 2+ binding, previous data from IX studies indicate that [SrOH] + is not the dominant species of concern in tank waste processing schemes.(Fiskum, Campbell and Trang-Le 2020) Our results show that the [Sr(NO3)]+ species and the [Sr(NO2)] + species form in considerable abundances, which may affect the ability to separate Sr using CST in nuclear waste separation processes.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

International Workshop on Security of Radioactive Sources during Extraordinary Events

On May 2, 2019, a subcontractor to Los Alamos National Laboratory (LANL) inadvertently breached a sealed Cs-137 source while attempting to remove the source for disposition as part of a United States (US) government-sponsored program. The source breach resulted in contamination of personnel, the building, and a release of material to the local environment.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Options for the Removal of Cesium and Strontium from Acidic Uranyl Sulfate Solutions from Molybdenum-99 Production

A small laboratory-scale column process aimed at removing fission products from prototypical acidic sulfate solution wastes from a prototypical Mo-99 recovery process has been operated in a radioactive materials hood at Savannah River National Laboratory. This equipment has been operated with realistic concentrations of uranium (0.4 wt % 235 U), plutonium ( 239 Pu), neptunium ( 237 Np), non-radioactive surrogates of common fission products (including Cs and Sr) and two promising absorbents AMP-PAN and CST R91290-B. The goal of this work was to demonstrate the removal and concentration of high specific activity isotopes which are expected to dominate the classification of the low-level waste from the production of 99 Mo. Both AMP-PAN and CST R9120-B are attractive absorbents for the removal of 137 Cs from an acidic sulfate waste stream. They do not provide a solution for the removal of 90 Sr from the acidic solutions, but CST should be investigated at a higher pH. Limited removal of transuranic species and almost no removal of uranium was observed in this testing. This could be important due to the relatively large amount of uranium expected to be present in such waste streams. The capacity of these absorbents for 137 Cs will likely be dependent on the Cs concentration in the solutions processed but loading in the range of 0.2 to 5 mg Cs per gram of absorbent appears to be achievable.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Regenerable Liquid Desiccants for High Efficiency Humidity Control in Microgravity

The NASA X-Hab project aims to design, manufacture, test, and prove functionality of an air humidity control subsystem to dehumidify and re-humidify air from a space cabin. The method of regulating cabin air humidity utilizes vortex phase separation, which uses an ionic liquid (IL) desiccant for air-water phase separation. This subsystem is intended to be integrated with a CO 2 removal system requiring de-humidified air to operate efficiently. The air humidity control subsystem is composed of a cold-desiccant or cold-side Vortex Phase Separator (VPS) that dehumidifies the cabin air. The dehumidified air exits the cold-side (CS) VPS chamber to flow into the CO 2 removal module, and the cold, water-laden liquid desiccant flows to a regenerative heat exchanger. From the heat exchanger the liquid desiccant continues to the heater. After heating, the desiccant flows into a hot-desiccant or hot-side (HS) VPS as the dehumidified air from CO 2 removal module enters through the HS VPS air inlet. The rehumidified air exits the HS VPS into the space cabin. One pump installed at the liquid exit of the CS VPS and one pump installed at the liquid exit of the HS VPS transport the fluid through the system. To evaluate the system’s efficiency and effectiveness, the temperature, pressure, flow rate and relative humidity are read, recorded, and analyzed at critical points along the module.

Gerardo Castro↗

Influence of Cs Loading on Pt/m-ZrO 2 Water–Gas Shift Catalysts

Certain alkali metals (Na, K) at targeted loadings have been shown in recent decades to significantly promote the LT-WGS reaction. This occurs at alkali doping levels where a redshift in the C-H band of formate occurs, indicating electronic weakening of the bond. The C-H bond breaking of formate is the proposed rate-limiting step of the formate associative mechanism, lending support to the occurrence of this mechanism in H2-rich environments of the LT-WGS stage of fuel processors. Continuing in this vein of research, 2%Pt/m-ZrO 2 was promoted with various levels of Cs in order to explore its influence on the rate of formate intermediate decomposition, as well as that of LT-WGS in a fixed bed reactor. In situ DRIFTS experiments revealed that Cs promoter loadings of 3.87% to 7.22% resulted in significant acceleration of the forward formate decomposition in steam at 130 °C. Of all of the alkali metals tested to date, the redshift in the formate ν(CH) band with the incorporation of Cs was the greatest. XANES difference experiments at the Pt L 2 and L 3 edges indicated that the electronic effect was not likely due to an enrichment of electronic density on Pt. CO 2 TPD experiments revealed that, unlike Na and K promoters, Cs behaves more like Rb in that the decomposition of the second intermediate in LT-WGS, carbonate species, is hindered due to (1) increased basicity of Cs, (2) the tendency of Cs to cover Pt sites that facilitate CO 2 decomposition, and (3) the tendency of Cs to increase Pt particle size as shown by EXAFS results, resulting in fewer Pt sites that facilitate CO2 decomposition. As such, the LT-WGS rate was hindered overall and the rate-limiting step shifted to carbonate decomposition (CO 2 removal). Like its Rb counterpart, low levels of added Cs (e.g., 0.72%Cs) were found to improve the stability of the catalyst relative to the unpromoted catalyst; the stability comparison was made at similar CO conversion level as well as similar space velocity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Cesium Removal from Surrogate Pyroprocessing Salt by Electrodeposition

Active metals in used nuclear fuel dissolve into the salt during pyroprocessing and are not removed by electrorefining or drawdown operations. The buildup of 137 Cs over time increases the heat load and ionizing radiation level of the salt such that it must be replaced frequently, resulting in a significant amount of salt waste. An effective means of managing cesium in the molten salt electrolyte would increase the efficiency of pyroprocessing and decrease the volume of salt waste requiring disposal. A previous report summarized issues that must be addressed when developing a removal strategy and assessed the suitability of existing methods and remaining technological gaps to their application (Rose and Thomas 2023). Cesium is extremely stable in molten salt as a chloride—even more stable than the LiCl-KCl eutectic base salt used for pyroprocessing fuel—which makes removing cesium a challenge. However, sufficiently strong atomic interactions occur between active metal species and liquid metals that make the electrodeposition of active metal fission products into liquid metal electrodes energetically favorable. The feasibility of recovering cesium from LiCl-KCl pyroprocessing salt through electrodeposition into liquid metals is eing assessed by identifying potentially effective liquid metals and performing tests to determine the effectiveness of electrodepositing cesium from a LiCl/KCl salt into these liquid metals. Previous studies investigating the electrodeposition of Sr 2+ , and Ba 2+ into zinc, cadmium, bismuth, lead, tin and antimony have shown that alkali and alkaline earth metals can be electrodeposited at liquid metal cathodes (Kim et al., 2018). The removal of Ba 2+ and Sr 2+ was measured to be more efficient than the removal of monovalent cations due to the greater thermochemical driving force for alloying those elements with the liquid metal (Jang et al. 2022). Because the equilibrium potentials are dependent on the interactions of the active metal in the liquid metal, it is likely that the other alkali metals Li + , and K + , will deposit from LiCl/KCl salt with the Cs + . Therefore, application of this method to recover active metals from pyroprocessing salt will benefit from the use of a liquid metal and set of operating conditions that sufficiently increase the reduction potential of cesium to remove cesium from the waste salt with an acceptable amount of co-deposited lithium and potassium.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

FY25 Ion Exchange Processing for the West Area Risk Management (WARM) Project

The West Area Risk Management (WARM) Project was established to enable near-term retrieval and pretreatment of tank waste from Hanford’s 200 West Area and to support deployment of an ion exchange (IX) system capable of producing cesium-depleted supernate suitable for offsite treatment and disposal. The WARM experimental campaign was designed to provide key data for design and operational planning of the 200 W IX system, which plans to utilize crystalline silicotitanate (CST) as the active media for cesium removal. This report documents a comprehensive FY25 experimental campaign designed to produce key technical data required for design and operational planning of the WARM IX system. Testing includes assessing Cs and Sr breakthrough performance in a 4-column system, Cs capacity batch contact testing, phosphate precipitation assessments, reduced-hydroxide feed displacement evaluation, and Sr speciation impacts on Sr removal. The experimental results provide detailed trends in Cs and Sr loading behavior, breakthrough performance across a 4-column staged IX system, distribution profiles within CST beds, and projections of operational flowrates relative to Waste Acceptance Criteria (WAC) limits. Batch contact testing established equilibrium partitioning behavior for the S1–S5 simulants and characterized how matrix chemistry influenced Cs sorption onto CST. Additionally, further evaluations on waste matrix as it pertains to precipitation potential were also determined. Collectively, these datasets support engineering design choices for WARM system throughput and pretreatment planning.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Sulfonamide and Sulfonamido-phenol Ligands for Extraction of f-Elements from Alkaline High-Level Waste

Alkaline High Level Waste (HLW) has been accumulated at Hanford and Savannah River Sites as a result of reprocessing for nuclear weapons production during the cold war. A large volume (∼100 MGal) has been accumulated in carbon steel tanks at Savannah River (SRS) and Hanford. The tank waste contains three separate phases generated when NaOH was added to previously acidic Purex raffinates: 1-2 Supernatant liquid, salt-cake, and sludge. The sludge consists mainly of insoluble hydroxides of transition metals while the supernate and salt-cake contain caustic-soluble materials, including salts of highly radioactive fission products Cs(I) and Sr(II). Current treatment of alkaline HLW in SRS includes: i) The Actinide Removal Process (ARP), which is based on sorption of {sup 90}Sr and Actinides (An) on monosodium titanate (MST), also known as 'alpha-strike' process, followed by ii) Caustic Side Solvent Extraction (CSSX),4 which is used for the extraction of {sup 137}Cs by modified calixarenes in a hydrocarbon diluent. Residual actinides in some tanks are removed after CSSX by an additional ARP process commonly referred to as 'alpha-finishing'. Despite the success of ARP for Sr and An removal, as it is a sorption process, it represents the kinetic bottleneck of integrated salt waste processing. Hence potential introduction of additional organic ligands for actinide extraction (in a modified CSSX process) could simplify the overall integrated process, making it more efficient and economical, with less titanate needed and shorter sorption time, as some of the actinide component would be removed during CSSX. In this study tri-sulfonamide and o-sulfonamido-phenol (mono-sulfonamide) ligands have been studied as extractants for Sm(III), which is being used as an Am(III) surrogate. Our prior studies in the group using a tri-sulfonamide (iPr-tsa-B) showed favorable extraction for Sm(III) nitrate salts from alkaline solutions. Mono-sulfonamides possess similar orientation of binding sites to pyrocatechols, which have been found to be good ligands for Am(III) binding and extraction from alkaline media. Tri-sulfonamide of the type iPr-tsa-B6 (1 mM in CH{sub 2}Cl{sub 2} solution) was studied for Ln{sup 3+} extraction using Sm(NO{sub 3}){sub 3}.6H{sub 2}0 (10 and 25 μM) in alkaline solution of NaOH (0.05, 0.1, 0.2, 0.3 mM) / 0.1 M NaNO{sub 3}. Stripping of the organic phase was done using 0.1 M HNO{sub 3} and quantification of Sm{sup 3+} was done using ICP-OES at 359.3 nm. The need to improve stability of the complex led to synthesis of compounds with N-donor site closer to the central benzene ring to facilitate cation-π interactions. Synthesis of tri-sulfonamide type A: a) Chloromethyl methyl ether, SnCl{sub 4}, CH{sub 2}Cl{sub 2}, 0 deg. C, N{sub 2}, 4 h, 57%; b) NaN{sub 3}, reflux in H{sub 2}O/acetone for 22 h, 80%; c) PPh{sub 3}, THF/H{sub 2}O, 22 h, 79%; d) p-toluene sulfonyl chloride, Et{sub 3}N, 1,2-DCE, 22 h. Extraction: Sm(NO{sub 3}){sub 3}.6H{sub 2}O (2 mM) in 5 ml of aqueous NaOH (pH 10.5 - 14) + 6 ml of CH{sub 2}Cl{sub 2} solution of msa (20 mole equiv.) were rotated on a wheel (60 rpm; 20 h). Stripping: 5 ml of 0.1 M HNO{sub 3} + CH{sub 2}Cl{sub 2} solution of msa (after extraction, centrifugation and filtration) was rotated on the wheel (60 rpm; 20 h). Sm{sup 3+} was quantified using UV-Visible spectrophotometry.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗