Search NASASearch

SEARCH · Search NASA

Results for “DIGITAL SIMULATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Pulse control of superconducting cavity-based qudits with a Fock-state basis

Fock-basis-encoding qudits allow quantum gates to operate on multiple qudit levels simultaneously. This capability is advantageous for applications involving complex local gate operations, such as the digital quantum simulation of non-Abelian gauge theories. However, compiling unitary operations to native qudit gates remains a challenging task, often requiring substantial computational resources. In this work, we theoretically investigate the direct pulse control of a superconducting radio-frequency cavity coupled to an ancilla transmon for gate synthesis. We will discuss the improvements and limitations applicable to high Fock states. This work paves the way toward more efficient and robust qudit-gate synthesis.

Li, Andy C.Y. [Fermilab] (ORCID:0000000345423739)

Primitive Quantum Gates for an $SU(3)$ Discrete Subgroup: $Σ(72\times3)$

We construct a primitive gate set for the digital quantum simulation of a discrete subgroup of $SU(3)$: the 216-element $Σ(72\times3)$. The necessary primitives are the inversion gate, the group multiplication gate, the trace gate, and the group Fourier transform, for which we provide qubit decompositions. The resulting fault-tolerant T gate costs for a fiducial calculation of shear viscosity would require about $10^{12}$ T gates which compares favorably to other modern estimates.

Perez, Sebastian Osorio [Fermilab; Maryland U.]

AI-supported mini-labs: combining smartphone-based experiments and multimodal AI

Multimedia learning has always been a topic in physics education—whether through specialized digital data acquisition systems, simulations, or animations. Due to increasing digitalization, more and more media from our everyday lives have also found their way into education in recent decades. This contribution introduces a conceptual framework and illustrative examples for AI-supported experimentation in physics education. It does not yet present empirical data but outlines directions for forthcoming classroom studies evaluating learning outcomes and engagement.

generative AI

Derivation of A Representative Elementary Volume (REV) for Upscaled Two-Phase Flow in Porous Media

Relative permeability plays an important role in the upscaling of multiphase flow in porous media from the pore scale to the Darcy scale. The entire concept of relative permeability is contingent on the existence of a representative elementary volume (REV). As we move to smaller samples to measure relative permeability, such as with digital core analysis, the concept of a classical REV has become increasingly unlikely when using the conventional approach to defining a representative volume. The “‘conventional”’ understanding of an REV is that a large enough volume must be considered such that spatial variability averages out. In digital rock methods, such as pore-scale simulations based on micro-computed tomography (CT) images, the domain size is typically 2 to 4 mm. This is approximately the length scale of a single-phase flow REV using the classic REV approach. However, the single-phase perspective does not consider the complex dynamics and fluctuations often observed in multiphase flow systems, even at centimeter-scale experiments and/or simulations. A fundamental question is, therefore, whether the domain size commonly used in digital rock simulations can provide a consistent energy budget such that the concept of relative permeability exists. Based on first principles, relative permeability accounts for the rate of energy dissipated in a stationary process. If the dynamics are fluctuating, the energy dissipated can vary but will average out over a long enough timescale. The key to determining the validity of the relative permeability is the timescale of the measurement, not the spatial scale. The conventional REV theory assumes that spatial, temporal, and ensemble averages are equivalent in an ergodic system, but it does not provide a way to test this assumption. We provide a formal way to identify the timescale where the relative permeability accurately captures energy dissipation as a way to validate relative permeability measurements and quantitatively assess their accuracy. This result will be tested for a practical SCAL test, determining how long a flow experiment needs to be run to accurately characterize the rate of energy dissipation by the flow. The outcome will be a best practice guide for the determination of relative permeability from core-scale experiments and/or digital core simulations that ensure the energy budget is fully accounted for in the relative permeability coefficient.

Mcclure, James [Virginia Tech, Blacksburg]

Data Quality Assessment Process for Real-Time Data-Driven Traffic Microsimulation of Smart Corridor

Smart corridor digital twins are often created for the development and evaluation of emerging intelligent transportation systems and Connected and Autonomous Vehicle (CAV) technologies. However, limited guidance exists for data quality assessment for digital twin development. To address this, this paper discusses the data quality assessment utilized to develop data-driven real-time microscopic simulation models, i.e., digital twins, for two separate smart corridors: the North Avenue Smart Corridor in Atlanta, GA, and the Martin Luther King Smart Corridor in Chattanooga, Tennessee. This paper provides a summary of the author’s investigations of data requirements and data characteristics for the given smart corridor digital twin development efforts. With a focus on data, this summary includes a description of the data investigation process, key data issues observed, and strategies to address observed issues. Discussion is provided to help expand the lessons from these studies to other digital twin development efforts.

Saroj, Abhilasha [ORNL] (ORCID:0000000191178063)

Microreactor Automated Control System - Digital Twin Models and Advanced Control Systems Updates

Automation of control systems is expected to be important in the economic and safe operation of microreactors. Therefore, there is a need to develop and demonstrate automated control for microreactors, along with the development of testbeds for this purpose. This report provides updates on the status of a nonnuclear microreactor automated control system (MACS)—a real-time, hardware-in-the-loop testbed for non-nuclear testing of microreactor control system automation. A real-time hardware-in-the-loop testbed incorporates the realistic dynamics of physical systems into control system development and testing. The collaborative effort between Oak Ridge National Laboratory (ORNL) and Idaho National Laboratory (INL) resulted in the development of a prototypic microreactor plant-level digital twin that includes the reactor and a balance of plant system. Advanced control strategies were incorporated to demonstrate testing of control automation solutions. The gRPC communication protocol, which was implemented in the hardware-in-the-loop testbed by INL, was coupled to a digital twin model developed using the TRANsient Simulation Framework of Reconfigurable Models (TRANSFORM) library in Modelica. This digital twin simulation was tested with the ViBRANT hardware for realistic feedback and visual representation of control action in real time. A modular Python client structure was developed to manage functional mock-up unit-based simulation and real-time gRPC communication. Hardware-in-the-loop testing indicated that the modeled reactor—a natural-convection, molten-salt coolant loop configuration—responds well to control of drum positioning for modulation of reactor core power, as well as system-level control and downstream demand changes. Ongoing research is focused on integrating additional control algorithms that utilize data from newly included sensors within the MACS hardware testbed, as well as demonstrating and assessing the performance of the different automated control algorithms on multiple additional operational scenarios.

22 GENERAL STUDIES OF NUCLEAR REACTORS

Enhancing traffic safety analysis with digital twin technology: integrating vehicle dynamics and environmental factors into microscopic traffic simulation

Traffic safety is a critical concern in transportation engineering and urban planning. Traditional traffic safety analysis requires trained observers to collect data in the field, which is time-consuming, labor-intensive, and sometimes inaccurate. In recent years, microscopic traffic simulation, which simulates individual vehicles’ movements within a transportation network, have been utilized to study traffic safety. However, microscopic traffic simulation only focuses on traffic-related factors, such as traffic volume, traffic signals, and lane configurations, neglecting vehicle dynamics and environment-related factors like weather and lighting conditions, which can significantly impact traffic safety. In light of this, this paper explores the application of digital twin technology in traffic safety analysis, integrating vehicle simulators, which consider vehicle dynamics and environmental factors, and microscopic traffic simulators, which simulate the operations of traffic flow, for enhanced safety evaluations. Various scenarios, including different weather conditions and visibility levels, are simulated using a digital twin of a road segment in Tuscaloosa, Alabama. The simulations employ Surrogate Safety Measures (SSMs) like Time to Collision (TTC) and Deceleration Rate to Avoid a Crash (DRAC) to assess safety under varying conditions. The results demonstrate that traffic digital twin can identify potential safety issues that traditional microscopic simulation cannot, providing insights for improving traffic control strategies and transportation infrastructure to enhance traffic safety.

Civil engineering

ARCADE Analysis Methods & Validation Pathway

The Advanced Reactor Cyber Analysis and Development Environment (ARCADE) provides an automated analysis system which supports risk-informed performance based (RIPB) evaluations of nuclear control systems. Every possible cyber threat which could lead to consequence is identified by simulating the unsafe control action sequences which transform digital harm into physical harm. Eliminating the simulation of complex digital cyber attack chains cuts out unnecessary computational overhead and focuses directly on the physics of cyber-physical attacks. This focus enables designers to make informed decisions which can entirely eliminate categories of cyber threats against advanced reactors through the physical nature of the plant design. This narrowing of cyber threat against nuclear power plants through the physics of the system is intended to make any remaining threat management and cost efficient. This is the goal of the Tiered Cyber Analysis (TCA) outlined in NRC Draft Regulation Guide (RG) 5.96, which provides a RIPB cybersecurity approach for new reactors. ARCADE has been custom developed to meet the demands of the rigorous analysis required in Tier 1 of the TCA, which forms the foundation of the TCA process. Currently, ARCADE is still under development, but has made significant leaps in capability. A pilot analysis on the opensource Asherah simulator was performed which demonstrated key functionality goals. The next stage of ARCADE development involves improvements to the applications which support the analysis system, and enabling the analysis system to utilize the full suite of unsafe control action simulations. Since the analysis method’s core functions are complete, validation of the analysis method will be started concurrent to the next development stages. The automated analysis ARCADE will provide can radically change the cybersecurity design process for advanced reactors, reducing the cost of security implementation while enhancing cyber resilience. The pathway for ARCADE’s development to this goal has become much clearer. The majority of technical hurdles have been cleared, and the remaining development needs have been solidified. ARCADE is now capable of assisting the advanced reactor design process and directly support advanced reactor industry RIPB practices.

22 GENERAL STUDIES OF NUCLEAR REACTORS

Event-driven readout development: testing of the EDWARD65P1 chip with integrated event generators

Building on a prototype readout integrated circuit for segmented silicon sensors with the EDWARD event-driven readout architecture, the front-end in each pixel was replaced by a hardware generator to verify readout performance, ensuring no data loss, consistent priority handling, and speed verification. Here, this generator produces Poisson-distributed readout requests with individually tunable rates per pixel via a digitally controlled oscillator. The resulting EDWARD65P1 test ASIC is a 32×32 pixel matrix with a 100 μm pitch, equipped with digital event generators simulating radiation hits at user-defined rates. Test results for this new design are presented.

47 OTHER INSTRUMENTATION

Development of Whole System Digital Twins for Advanced Reactors: Leveraging Graph Neural Networks and SAM Simulations

Here, in this work, we introduce a novel method to develop whole system digital twins (DTs) for advanced nuclear reactors. This method treats a complex reactor system as a heterogeneous graph: with the system components as different types of graph nodes and their physical interconnections as edges. Based on the heterogeneous graph, a graph neural network combining graph convolution and temporal node attention is developed as the DT, facilitating a comprehensive understanding of the system's dynamic behavior. By utilizing the System Analysis Module (SAM) code for simulating various operational transients, we develop a graph-based database that trains the DT. This DT is characterized by two primary functions: It can infer the entire system's status using sparse node information, and it can predict the progress of transients based on current and historical system information. Our approach is validated through case studies on the Experimental Breeder Reactor II (EBR-II) system and a generic Fluoride-salt-cooled High-temperature Reactor (gFHR), demonstrating the DT's accuracy in forecasting operational transients. The DT's rapid computation capabilities enhance its potential for supporting advanced reactor operations, offering benefits in intelligent simulation, autonomous control, and anomaly detection, paving the way for improved safety analysis and intelligent component health management for advanced reactor systems and reducing their operations and maintenance cost.

EBR-II

Demonstrating the data center as a flexible grid asset using a C-HIL setup

Increasing data center demand is outpacing grid infrastructure development. Artificial intelligence workloads and hyperscale cloud growth are creating unprecedented demand for power, while traditional grid expansion faces multiyear development timelines. Verrus is developing an innovative datacenter solution for this challenge, data centers that act as active grid-supportive assets rather than passive loads. Our approach integrates a novel grid-aware power flow management system with battery energy storage systems(BESS) into a microgrid-controlled, medium-voltage power distribution architecture that delivers critical capabilities, such as: * Fast response to grid disturbances such over/ under voltage or over/ under frequency * Demand flexibility that can service requests from the utility within 10 s * Uninterrupted transition to islanded operation during grid outages * Continuous uptime assurance for compute loads while maintaining all customer service level agreements. Through Verrus' strategic partnership with the National Renewable Energy Laboratory (NREL), these capabilities were validated using NREL's Advanced Research on Integrated Energy Systems (ARIES) virtual emulation environment to model a 70-MW grid-interactive data center. This paper outlines the design, methodology, and results of this emulated deployment, demonstrating that data centers can provide both critical load resilience and ancillary grid support without compromising uptime requirements. Specifically, we present a digital real time simulation of a 70 MW data center integrated with a physical microgrid controller, and demonstrate the data center response in the event of a grid voltage and frequency event, utility demand response request and utility outage.

24 POWER TRANSMISSION AND DISTRIBUTION

A dual-species Rydberg array

Large-scale Rydberg atom arrays are used for highly coherent analogue quantum simulations and for digital quantum computations. However, advanced quantum protocols, such as quantum error correction, require midcircuit qubit operations, including the replenishment, reset and read-out of a subset of qubits. A compelling strategy for unlocking these capabilities is a dual-species architecture in which a second atomic species is controlled independently and entangled with the first through Rydberg interactions. Here, we realize a dual-species Rydberg array consisting of rubidium and caesium atoms and explore regimes of interactions and dynamics not accessible in single-species architectures. We achieve enhanced interspecies interactions by electrically tuning the Rydberg states close to a Förster resonance. In this regime, we demonstrate an interspecies Rydberg blockade and implement a quantum state transfer from one species to another. We then generate a Bell state between Rb and Cs hyperfine qubits through an interspecies controlled-phase gate. Finally, we combine interspecies entanglement with a native midcircuit read-out to achieve quantum non-demolition measurements.

atomic and molecular interactions with photons

Digital Twin Based Condition Monitoring of LCC-LCC Inductive Power Transfer Systems

Inductive power transfer (IPT) systems provide a flexible, hands-free charging opportunity to electric vehicles (EV). The resonant network components and the transmitter and receiver coils are often subjected to high voltages or currents. Component aging in the compensation network and coils of resonant IPT systems is detrimental to the reliability and power transfer efficiency of the IPT system. Monitoring the component health of such multi-element complex systems requires robust optimization algorithms. This paper discusses condition monitoring of a resonant IPT system for an EV charger using a digital twin model. A hybrid estimation algorithm based on genetic algorithms and adaptive particle swarm optimization is developed to estimate the parameters of the digital twin model. Simulation results are used to verify the monitoring capabilities of the developed algorithm under various operating conditions of the IPT system.

Weldehawaryat, Lidya Mussie [graduate research ass

Experiments and Project-Based Enhancements for STEM Learning: Preprint

Motivating k-12 students to pick a career in science, technology, engineering, and mathematics (STEM) is an effort that requires consistent attention. At different points in time, STEM educators need to pivot themselves and update educational materials to consistently motivate the next generation of k-12 students to enter into STEM careers. Once they enter undergraduate education, universities need to motivate their undergraduates students to consider graduate studies to ensure qualified human resources can be developed for research, and teaching. We present in this paper, our work on developing STEM materials for k-12 students targeting grid integration of hydrogen assets. This paper also presents our work on leveraging open source distribution system model, digital real time simulation tool to create projects for undergraduate students and motivate their interest in research topics, and enter into graduate level education.

electro-magnetic transients

A digital twin platform for building performance monitoring and optimization: Performance simulation and case studies

Advancements in sensor technology, data analytics, affordable compute, and communication infrastructure have paved the way for Digital Twin technology in optimizing building operations and controls. This study presents the development of an open and interoperable web-based Digital Twin platform for integrating diverse data streams and facilitating effective user interactions. The platform utilizes modern technologies for the web framework and time-series data management, ensuring scalability and responsiveness. The backend supports seamless integration of diverse data sources and emulators, incorporating data from building sensors and meters, external weather Application Programming Interfaces, and advanced EnergyPlus simulation models of the building and its energy systems including the Distributed Energy Resources that are formulated in Functional Mockup Units. A simulation case study was conducted with FlexLab, a test facility on Lawrence Berkeley National Laboratory campus. The case study includes normal operations, Distributed Energy Resource integration, and power outage scenarios, to illustrate the Digital Twin’s ability to provide critical insights into energy performance and thermal resilience. The results demonstrated the platform’s potential as a decision-support tool for optimizing building energy performance and enhancing resilience against extreme weather events. Future work will focus on deploying the Digital Twin platform to a real building for field validation, extending its capabilities to cover more scenarios such as bidirectional Electric Vehicle interactions, and enhancing user engagement.

EnergyPlus

Powder metallurgy hot isostatic pressing - workshop report

The findings of the powder metallurgy (PM) hot isostatic pressing (HIP) workshop confirmed that the accelerated adoption of this technology requires the following action items: 1. By 2035, the HIP infrastructure must be scaled to sizes larger than 4 .0 meters for manufacturing components relevant to energy and defense industries at large. 2. The community must develop cost-effective and agile standards, qualifications, and certification pathways for these HIP parts. 3. At the same time, domestic powder production should be expanded to a wide range of metallic alloys, including Cr-Mo steels, stainless steels, and titanium- and nickel-based superalloys, as well as to emerging alloy classes in the refractory space. 4. The above initiatives can be enhanced by implementing digital modeling and controls, including AI-driven simulations, in situ monitoring, and digital twins.

36 MATERIALS SCIENCE

PHIL Interface Design for Use With a Voltage-Regulated Amplifier

Power hardware-in-the-loop (PHIL) has emerged as a leading strategy to thoroughly assess the impact of proprietary inverter controls on a specific power system. The development of a PHIL test bed typically involves an inverter under test, a power amplifier, controllable DC supply, and a digital real-time simulator (DRTS) to simulate the power system under study. As a result of PHIL nonidealities, a form of digital compensation within the DRTS is used, which is commonly referred to as a PHIL interface. Many existing methods use legacy power amplifiers that do not contain internal voltage regulation. These existing interface methods are based around a voltage regulator within the DRTS and do not consider the interaction with the controls in newer amplifiers. In this study, a three-step approach of PHIL interface development for modern power amplifiers with built-in voltage regulation is introduced and is validated in hardware with a 30-kW grid-following inverter.

DRTS

Digital Grid Twin–Direct Communication Scheme Test Bed for Assessing Relay-to-Relay Radio Antenna and Optical Fiber Performance and Misoperations

This study introduces a novel “Digital Grid Twin–Direct Communication Scheme” test bed. This advanced platform evaluates point-to-point communication between transmitter and receiver relays with optical fiber and radio omnidirectional antenna systems, implemented at the Advanced Protection lab in the Grid Research Innovation and Development Center at Oak Ridge National Laboratory. The increased diversity of energy sources has led to more protective relay misoperations. In North America, microgrid protection schemes now use point-to-point communication along distribution lines between relays to implement advanced logic in nonradial grids that include both high- and low-inertia generators. This trend challenges utilities to minimize misoperations while ensuring rapid fault clearance and accurate selectivity coordination between primary and backup relays. This study assesses relay-to-relay communication schemes by introducing an advanced testing platform based on a digital grid twin protection test bed using a synchronized time source system. The platform evaluates the communication system using radio antennas or optical fiber links by integrating protective relays that operate breakers within the digital twin and record relay events and communication signals. In the experiments, transmitter and receiver relays were configured with inverse time overcurrent and breaker trip detection logic to assess the total time of the communication protection schemes based on the sum of the relay protection element operating time, radio latency, propagation delay, baud rate delay, and relay processing time. These delays were derived from recorded relay events and communication signals from the interface of a real-time simulator set as a digital grid twin. The test bed successfully simulated various electrical faults along a distribution line while ensuring effective and reliable point-to-point communication between transmitter and receiver relays. The radio antenna communication system exhibited latency because of the radio. This latency depends on the baud rate setting and type of radio application; in general, the higher the baud rate, the lower the radio latency. The measured radio latency (for Mirrored Bits with an encryption card at 9,600 bps) was about 9–10 ms. Additionally, calculated propagation delay per mile for radio antennas and optical fiber was 5.36 µs/mi and 8.04 µs/mi, respectively. Optical fiber communication did not demonstrate radio latency. Instead, the protection element operating time depends mainly on the protection logic function set in the relay, and the relay processing time depends on the processing rate of the relay in samples per power system cycle.

24 POWER TRANSMISSION AND DISTRIBUTION