Search NASA⌕ Search

SEARCH · Search NASA

Results for “Disruption management”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Overview of the KSTAR experiments and future plan

The Korea Superconducting Tokamak Advanced Research (KSTAR) device has recently entered a new phase of operation following the installation of a tungsten mono-block divertor, providing a unique platform to investigate high-performance, long-pulse plasma scenarios for future reactors. The 2023–2024 experimental campaigns demonstrated significant progress in commissioning the tungsten divertor, developing plasma operation scenarios, and achieving real-time control. Comparative studies revealed increased core radiation losses and associated performance degradation relative to the carbon divertor environment. Alleviation strategies, such as optimized neutral beam injection timing, boron powder seeding, and impurity control through gas puffing, were shown to reduce tungsten accumulation and extend high-performance phases, including record H-mode operation exceeding 100 s. International collaboration enabled the first demonstration of high poloidal beta scenarios with an internal transport barrier on KSTAR. Advances in control included upgraded real-time resonant magnetic perturbation schemes and disruption forecasting. Furthermore, divertor detachment control using a new surrogate-model-based approach with real-time radiation imaging demonstrated active impurity and heat flux management. Supported by enhanced heating, current drive, and diagnostic systems, these achievements offer valuable insights into tungsten impurity behavior, transport physics, and control strategies for future reactors including ITER. Planned upgrades toward a full-tungsten wall and ITER-aligned real-time plasma control will further establish KSTAR as a leading experimental platform for developing operational scenarios required to achieve steady-state, burning plasma conditions.

KSTAR↗

An Overview of Behind-the-Meter Solar-Plus-Storage Regulatory Design: Approaches and Case Studies to Inform International Applications

Behind-the-meter energy storage systems paired with distributed photovoltaic (DPV) - with the capability to act as both generation and load - represent a unique and disruptive power sector technology capable of providing a range of important services to customers, utilities, and the broader power system. How should regulators, utilities, and policymakers manage the range of challenges and opportunities that increased behind-the-meter energy storage deployment will bring to the power system, in particular when these systems are paired with DPV? This report is intended to offer key regulatory considerations for facilitating DPV-plus-storage programs for retail customers; relevant cases from U.S. states are provided as examples of how novel regulatory issues related to behind-the-meter energy storage systems paired with DPV are being addressed in practice. At a high level, designing a regulatory framework that aligns DPV-plus-storage deployment with larger policy objectives requires thoughtful deliberation across a range of technical and economic issues. While this report attempts to segment many of these issues into distinct topics to enhance reader understanding, in reality, DPV-plus-storage regulatory issues are all closely integrated, and design decisions on a single aspect often have broader implications. With that in mind, this report outlines a series of steps that can be employed by regulators to approach DPV-plus-storage regulatory design.

14 SOLAR ENERGY↗

Securing the Modern Grid: Federal Investments, Digitization, and Supply Chain Strategy

Across the United States (U.S.) grid expansion and modernization is underway, paving the way for accelerated load growth and intelligent resource management. Digitization of the grid is supported by several state and federal programs, providing support for utilities installing advanced metering infrastructure (AMI), AI-powered analytics systems, battery energy storage systems (BESS), and distributed energy resource management systems (DERMS) to transform the grid from a one-way power delivery system into an intelligent, responsive network that will enable faster load growth and power expansion of data centers for advanced artificial intelligence (AI) applications. The digital transformation of America's grid presents opportunity for increased efficiency and resiliency but also introduces new digital risks that require careful management. Digital equipment often contains several vulnerabilities such as unencrypted communication protocols, and persistent remote access capabilities that could be exploited to manipulate device settings, coordinate service disruptions, or inject false data into grid operations. These digital risks become particularly important as the grid must rapidly scale to support AI-driven data centers, which the administration has identified as essential for maintaining U.S. technological leadership and economic competitiveness. These vulnerabilities are compounded by supply chain realities: Chinese manufacturers currently produce 70-90% of essential grid components including inverters, batteries, and control systems, with the U.S. lacking domestic manufacturing capacity for critical assets like extra-high voltage transformers. Recent federal legislation has established Foreign Entity of Concern (FEOC) restrictions to address these risks, requiring projects to achieve escalating thresholds of non-FEOC content to receive tax credits while utilities work to expand sourcing channels for their supply chains and strengthen security measures. These restrictions arrive precisely when utilities face unprecedented electricity demand growth driven by the rapid growth in data centers, creating a considerable challenge: rapidly expanding infrastructure while navigating complex compliance requirements while lacking viable alternatives for many critical components. Idaho National Laboratory (INL) and its partners have developed practical approaches to help utilities navigate these intersecting challenges as they leverage federal investment to strengthen and grow the grid. These solutions include Cyber-Informed Engineering (CIE) principles that build resilience directly into systems, the Cirrus tool for secure cloud migration, and enhanced procurement guidance that embeds security requirements throughout equipment lifecycles. Federal initiatives, such as the Technical Assistance for Digital Assurance (TADA) project, provide direct support to utilities implementing these approaches while facilitating knowledge sharing across the industry. While these tools and frameworks cannot eliminate all risks inherent in foreign supply chain dependencies, they offer pragmatic pathways for strengthening security posture without sacrificing the deployment momentum essential to meeting surging electricity demand. Ultimately, securing America's digital energy infrastructure demands dedicated coordination across multiple fronts: building domestic supply chains, implementing robust digital assurance practices, and maintaining the aggressive modernization timeline necessary for reliability, resilience, and energy independence.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Tackling the Giants: Applying Smart Labs Principles to Constant Air Volume Lab Buildings

Laboratories typically consume 3 to 10 times more energy than similarly sized commercial buildings, and as much as 50% of that energy is wasted by inefficient and poorly operating fume hoods and ventilation systems. One challenge faced by older laboratory buildings is the heating, ventilation, and air-conditioning systems serving many of these buildings. The older systems are usually constant air volume (CAV) systems that maintain constant ventilation rates that cause excess airflow and inefficient energy use. Variable air volume systems can be more efficient systems with sensors to detect the need for a change in volumetric flow rate; however; renovation of ventilation systems can create disruption to ongoing research and operations along with considerable up-front costs. When a Smart Labs program is implemented, an organization has a systems-based management approach that yields a high-performing laboratory building. As decarbonization continues as a priority for sites, buildings with CAV systems are difficult to address. This work centers around practical guidance for improving lab buildings with CAV. In conjunction with industry input on top technology solutions and best practices, recommendations will include performing a laboratory ventilation risk assessment in conjunction with robust retro-commissioning work, which is a crucial step in the Smart Lab process. By applying Smart Labs principles, the aging laboratory building stock of 153,343 (Lawrence Berkeley National Laboratory [LBNL] 2017), comprising roughly 500,000 lab spaces in the United States, can be brought to safe and high-performance operations.

building↗

Methods and Tools To Assess Robustness of Nuclear Plant Outages

Refueling outages are one of the most challenging phases in a nuclear power plant (NPP) operating cycle. Refueling outages are extremely costly for an NPP due to the large amount of required resources and because of lost revenue due to plant being off the grid. Outage durations have steadily decreased across the industry over that last few decades primarily due to improved planning and coordination, but there are still many plants that struggle to meet the performance metrics accomplished by other utilities. Schedule resilience is one of the issues. NPP outages require scheduling thousands of activities within 30 days on average. Despite detailed planning, once the outage starts, numerous emergent issues typically appear along with schedule delays requiring continuous replanning and adjustment. When schedule disruption occurs during an outage, plant staff make urgent efforts to recover but are often not able to maintain the planned outage duration. These outage delays can cost a utility several million dollars per day. Tools that could help outage schedulers create a more resilient schedule and allow them to optimally reschedule emergent work could significantly reduce outage delays. One key aspect of creating a resilient schedule is to have accurate estimates for activity duration. Another important outage scheduling capability is the ability to schedule emergent work with minimal disruption. This paper focuses on developing tools and methods to support NPPs with outage schedule optimization and it describes the initial development of tools to support outage management that leverage computational and machine learning methods.

97 - MATHEMATICS AND COMPUTING↗

Disrupting EV Charging Sessions and Gaining Remote Code Execution with DoS, MITM, and Code Injection Exploits using OCPP 1.6

Open Charge Point Protocol (OCPP) 1.6 is widely used in the electric vehicle (EV) charging industry to communicate between Charging System Management Services (CSMSs) and Electric Vehicle Supply Equipment (EVSE). Unlike OCPP 2.0.1, OCPP 1.6 uses unencrypted websocket communications to exchange information between EVSE devices and an onpremise or cloud-based CSMS. In this work, we demonstrate two machine-in-the-middle (MITM) attacks on OCPP sessions to terminate charging sessions and gain root access to the EVSE equipment via remote code execution (RCE). Second, we demonstrate a malicious firmware update with a code injection payload to compromise an EVSE. Lastly, we demonstrate two methods to prevent availability of the EVSE or CSMS. One of these, originally reported by SaiFlow, prevents traffic to legitimate EVSE equipment using a DoS-like attack on CSMSs by repeatedly connecting and authenticating several CPs with the same identities as the legitimate CP. These vulnerabilities were demonstrated with proof-of-concept exploits in a virtualized Cyber Range at Wright State University and/or with a 350 kW Direct Current Fast Charger (DCFC) at Idaho National Laboratory. The team found that OCPP 1.6 could be protected from these attacks by adding secure shell (SSH) tunnels to the protocol, if upgrading to OCPP 2.0.1 was not an option. Index Terms—Electric vehicle charging, cybersecurity, OCPP, cyberattack, cyber-resilience. INSPEC Accession Number: 23981565

99 GENERAL AND MISCELLANEOUS↗

Multibunch Studies for LCLS-II High Energy Upgrade

The Linac Coherent Light Source (LCLS) X-ray free-electron laser at SLAC is being upgraded to LCLS-II with a superconducting linac and 1 MHz bunch repetition rate. The proposed high-energy upgrade (LCLS-II-HE) will increase the beam energy from 4 to 8 GeV, extending the reach of accessible X-ray photon energies. With the increased repetition rate and longer linac of LCLS-II-HE, multi-bunch effects are of greater concern. We use recently introduced capabilities in the beam transport code ELEGANT to study dipole and monopole beam breakup effects for LCLS-II HE beam parameters. The results indicate that resonant dipole kicks have steady-state settle times on the order of 500 bunches or less and appear manageable. We also consider a statistical variation of the cavity frequencies and transverse offsets of cavities and quadrupoles. Resonant emittance growth driven by monopole kicks is found to be disrupted by frequency variation between cavities.

43 PARTICLE ACCELERATORS↗

Wildfire and power grid nexus in a changing climate

Global wildfire events have had increasingly severe impacts in recent years, particularly in the western USA, driven by extreme fire-weather conditions, fuel accumulation and multiple ignition sources. Wildfires sparked by power lines tend to be larger and more destructive, as they often occur during high winds, which accelerate the spread of fires. Moreover, efforts to contain wildfires frequently result in power outages, causing considerable economic disruption. Here, in this Review, we examine wildfire risks related to power-line-induced ignitions, infrastructure damage, climate-induced environmental impacts, grid operational risks, real-time grid management risks, vegetation management risks, and financial and funding risks in the context of a changing climate and their interdependence with power grid infrastructures. We then explore the resilience of power grids under wildfire threats, looking at risk analysis, prediction and mitigation strategies. The Review also shares practical insights and experiences in the USA to inform researchers, policymakers and industry professionals.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Managing the techno-economic impacts of partial string failure in multistring energy storage systems

The role of energy storage systems (ESSs) is becoming increasingly important for today’s electric power systems. Unavailability of an ESS assigned to critical grid services may cause unwanted disruption of those services and hence, may have a significant techno-economic impact. Like any physical equipment, an ESS is vulnerable to various types of faults. Failure of one or more strings in a multistring ESS does not have to be the cause of shutting down the entire ESS. It can still operate with a partial number of strings and continue providing critical services to the grid, if there are no reliability or safety issues and is acceptable under applicable standards. However, it is important to make sure that the control strategies are adaptable to the changes in ESS capacity caused by failed strings. Also, depending on the previous operation and type of failure, the reallocation of duty cycle burden among available strings could be non-uniform. These complexities suggest that mitigation of the impact of partial failure in multistring ESSs is not trivial and needs careful consideration. This is the topic of this paper. The proposed work investigates the impact of partial failure of a large multistring ESS on the assigned service and develops strategies to adjust the ESS control duty cycles for reducing such impacts. In doing so, the paper proposes a novel two-stage framework that plans for the multistring failure using robust optimization theory and then adjusts in real-time using a rule-based algorithm, based on the real-time information on the power availability of the string. Illustrations provided in this work are based on frequency regulation use-case, which is a common application for many utility-scale ESSs. A 750 kilowatt (kW)/1500 kilowatt-hour (kWh) 3-string ESS is used for the demonstration in this work and the efficacy of the proposed method is demonstrated and compared against methods that do not incorporate string failure in their strategy. In particular, here we show that revenue loss of 93% can be incurred when partial string failure is not included in operation and planning. These losses in revenue are reduced by 60% with the proposed method.

25 ENERGY STORAGE↗

National-Tribal Critical Infrastructure Protection: Collaboration for Extraordinary National Security Benefit

This paper examines national and tribal collaborative opportunities to get ahead of the critical infrastructure insecurity problem. Recommendations are viewed through the lens of the Sandia Labs Tribal Cyber-Energy initiative and national security projects. Recommendations include 1) Collaboratively address national priority and shared challenges to gain faster and better solutions to national priority problems on a smaller yet comprehensive American Indian and Alaskan Native sovereign single-point of authority scale 2) Utilize newer standards-based technologies to provide scalable, capable, and manageable solutions for greatly expanded and connected national critical infrastructures 3) Employ Cyber-Physical-Resilient design preliminary analysis to define concept- to-disposition design requirements for preemptive critical infrastructure risk mitigation and baked-in security; 4) Develop data-centric protection to provide increased information asset protection as data shifts from data-owner operated on-premises infrastructure to virtual service provider data-steward owned and operated off-premises infrastructure; and 5) Balance shared solutions with the National Institute of Science and Technology (NIST) Cybersecurity and Risk Management frameworks, and the System Security Engineering Guidelines. As yet unallocated federal funding would support research, development, the timely application of National-Tribal critical infrastructure protection, and critical infrastructure Cyber disruption response and recovery with extraordinary mutual benefits for the foreseeable future. The Critical Infrastructure Insecurity Problem: Rapid modernization and expansive connectivity are due to advances in Information and Communications Technologies that have sweeping cyber impact across all critical infrastructure sectors. Supervisory Control and Data Acquisition and Industrial Control Systems are particularly impacted as systems long separated from the Internet are now being connected and computerized. Virtualization and mobility create a Data Everywhere-User Anywhere paradigm that has evaporated the enterprise network perimeter. There are multi-front technological challenges at play, where long depended on technologies simply don't scale to current needs resulting in a digital dichotomy of competing old and new standards. New standards-based technologies scale but are not as well-known or as widely deployed, which leaves decision makers, stakeholders, and the workforce in a quandary, caught mid-stream between the technological past and the virtual future. Rapid and expansive cyber threat accompanies disruptive change in connectivity and computational dependencies. A lack of action will exacerbate the problem if new technologies roll out without baked-in security design. The Risk: If National-Tribal CIP collaboration to design in security is not done, then an ongoing state of insufficient bolt-on security and elevated threat exposure will remain for years to come.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Influence of isoelectronic mass modulation on phonon decay and transport in layered pnictogen-carbon systems

This study systematically investigates the structural, electronic, and thermal transport properties of layered pnictogen–carbon (Pn 2 C 2 ; Pn = P, As, Sb, Bi) monolayers, revealing a profound influence of isoelectronic mass modulation on phonon dynamics and thermal conductivity. Through first-principles calculations and lattice dynamics analysis, we demonstrate that increasing the atomic mass of pnictogens leads to elongated Pn-C bonds, weakened interatomic interactions, and enhanced phonon-phonon scattering, resulting in a dramatic reduction in lattice thermal conductivity (κ). Specifically, κ decreases exponentially from 65.6 W/m-K in P 2 C 2 to an ultralow 0.37 W/m-K in Bi 2 C 2 , driven by suppressed acoustic-optical phonon gaps Δ$^{Γ}_{A-0}$, increased anharmonicity, and reduced phonon lifetimes and group velocities. The transition from semiconducting to metallic behavior in heavier pnictogen-based systems further enhances phonon-electron scattering, contributing to thermal conductivity suppression. Structural analysis highlights the strengthening of out-of-plane C—C bonds and the contraction of C—Pn—C bond angles, which disrupt in-plane phonon transport. Further, these findings establish a design framework for engineering ultralow-κ materials through chemical substitution and structural tuning, offering significant potential for thermoelectric and thermal management applications. This work provides fundamental insights into phonon decay mechanisms and thermal transport in 2D materials, paving the way for advanced phononic and energy-efficient devices.

2D materials↗

Interparticle Characterization of Mechanical Biomass Particle-Particle and Particle-Wall Interactions

The biomass materials industry faces significant challenges in managing material variability and its impact on storage and handling systems. Physical properties such as moisture content, particle size, and density fluctuate considerably, leading to operational issues like bridging and ratholing that disrupt material flow. These variations create a complex cascade effect throughout the process chain, affecting transportation, storage, and conversion processes. The economic consequences of this variability manifest in increased operational costs, maintenance requirements, and system downtime. Environmental factors further complicate the situation, as weather conditions and seasonal availability influence material properties and system performance. Engineers employ specialized equipment design, material characterization protocols, and pre-processing steps like size reduction and homogenization to address these challenges. A critical knowledge gap exists between continuous-level constitutive models and particle-scale behavior. This project developed a novel device to quantify interparticle mechanics between biomass particles, measuring friction and adhesion forces between particles and wall materials. The research focused on corn stover and southern pine forest residue, creating a comprehensive database of particle interactions. This breakthrough enables direct application in particle-based computational modeling, advancing the field's understanding of biomass handling characteristics and supporting the development of more reliable and efficient storage and handling systems. The project's outcomes contribute significantly to understanding biomass's mechanical and flow characteristics, particularly how variability at the particle level affects larger-scale handling operations. This knowledge is crucial for engineering feedstock supply systems that consistently meet quality and cost specifications for various conversion processes. The innovative experimental setup developed through this research represents a significant advancement in biomass characterization methodology. Providing precise measurements of particle-level interactions establishes a foundation for more accurate predictive modeling of bulk material behavior. This enhanced understanding of fundamental particle mechanics enables engineers to anticipate better and address handling challenges before they manifest in full-scale operations. This research opens new avenues for optimizing biomass handling systems through data-driven design approaches. The comprehensive database of particle interactions serves as a valuable resource for future research and development efforts, potentially leading to more efficient and cost-effective biomass processing solutions. This advancement in particle-level mechanics could revolutionize how biomass handling systems are designed and operated, contributing to more sustainable and reliable renewable energy production.

09 BIOMASS FUELS↗

Cybersecurity Resiliency of Marine Renewable Energy Systems Part 2: Cybersecurity Best Practices and Risk Management

Marine renewable energy (MRE) is an emerging source of power for marine applications, marine devices, and coastal communities. This energy source relies on industrial control systems and IT to support operations and maintenance activities, which create a pathway for an adversary to gain unauthorized access to systems and data and disrupt operations. Incorporating cybersecurity risk prevention measures and mitigation capabilities from inception, development, operation, to decommissioning of the MRE system and components is paramount to the protection of energy generation and the security of network architecture and infrastructure. To improve the resilience of MRE systems as a predictable, affordable, and reliable source of energy, cybersecurity guidance was developed to enable operators to assess cybersecurity risks and implement security measures commensurate with the risk. This publication is the second of a two-part series, with Part 1 addressing a framework to determine cybersecurity risk by assessing the vulnerability of an MRE system to potential cyber threats and the consequences a cyberattack would have on the end user. This Part 2 publication describes an approach to select appropriate cybersecurity best practices commensurate with the MRE system's cybersecurity risk. The guidance includes 86 cybersecurity best practices, which are associated with 36 cybersecurity domains and grouped into nine categories. The best practices follow the core functions of the National Institute of Science and Technology Cybersecurity Framework (e.g., identify, detect, protect, respond, and and recover) and insights from both maritime and energy industry guidance documents to identify security measures effective in protecting information and operational technology assets prevalent in MRE systems.

97 MATHEMATICS AND COMPUTING↗

Manufacturing Management System Overview [Slides]

Vision: Institute a trusted manufacturing capability within the ALDWP Production Agency enabling digital product acceptance and access to digital manufacturing post-production activities. Mission: Establish a modern manufacturing infrastructure that ensures operator credentials, minimized human transcription errors, capable of managing all aspects of manufacturing including digital data acquisition, NCR resolution, and product acceptance, while providing an effective and intuitive user experience. Strategy: Constitute the modern manufacturing infrastructure to minimize risk and plant disruption while incrementally involving the capability.

42 ENGINEERING↗

Low-cost Manufacturing of Semitransparent CdTe PV for Building Integration

Solar has been demonstrated to be a robust renewable energy source, constituting a significant portion of the United States’ renewable energy portfolio. Despite its growth across residential, commercial, and utility sectors over the past decades, it remains a small fraction of the overall energy infrastructure. Challenges persist in fully harnessing solar power to meet the nation's escalating energy demands. Among these challenges lies the hurdle of efficiently distributing large quantities of solar-generated electricity to densely populated regions with the highest energy needs and costs. Traditional utility-scale arrays demand extensive land, a luxury often unavailable in metropolitan areas. Consequently, installations must be situated at a distance, necessitating additional infrastructure for electricity transmission to service areas. While metropolitan landscapes lack sprawling open spaces suitable for conventional utility-scale solar deployment, they offer a different resource: windows. Semitransparent photovoltaic window technology has the potential to not only bolster the grid's energy capacity, but to also provide HVAC and economic advantages to building owners. However, commercial availability of building-integrated photovoltaic windows remains limited. Silicon based photovoltaics currently dominate the solar market but adapting them for use in windows poses a variety of engineering and economic challenges such as relatively low power density, high costs associated with custom manufacturing, and aesthetic considerations. Addressing these challenges, this project explored the use of laser ablation patterning to manufacture cost-effective, high-efficiency, semitransparent Cadmium Telluride photovoltaic modules. Results showcased the potential of this methodology in developing photovoltaic windows and other innovative semitransparent PV applications. The ablation manufacturing technique demonstrated great versatility in achieving different patterns and levels of visible light transmission, and the power loss due to ablation was nearly directly proportional to the amount of material removed. Furthermore, the manufacturing process for Cadmium Telluride modules already has established advantages in material and energy efficiency, and the conversion of a standard submodule to semitransparent essentially requires a single additional process step, ensuring scalability. It is important to note that during this work, Toledo Solar experienced substantial organizational upheaval stemming from a lawsuit with First Solar. An external investigation led the board of directors to remove and replace the previous management team, and several other members of the staff elected to depart as well, including the then acting Principle Investigator on this project. The remaining Toledo Solar team attempted to recover from the disruption and deliver on the remaining tasks, but upon its own review, the Department of Energy ruled the project in default and terminated the contract in December 2023.

14 SOLAR ENERGY↗

Contesting with the Ganges Water Machine in South Asia: Theory versus Reality

Recently, there has been much interest in how to manage the water resources of the Ganges River Basin (GRB), the cradle of Asian civilization, currently supporting >500 million people. This also includes cleaning up the Ganges river, regarded as one of the most polluted mega-rivers of the world. Historically, the transboundary Ganges river and its tributaries, flowing through India, Nepal, and Bangladesh, have become extensively polluted and disrupted, mostly because of river engineering and increased discharge of industrial and urban waste. Compounding the problem, in the past few decades, intense groundwater abstraction from the GRB aquifers has led to unprecedented groundwater level depletion in some locations. At present, the GRB groundwater levels are strongly influenced by depth-dependent abstraction, which is predicted to intensify in the future, given the increasing water demand. Therefore, with impending climate change, designing the coupled river water–groundwater management necessary to meet the goal for sustainable access to clean water for a huge population, has become an arduous challenge.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Best practices: Organizational execution

This article, the fourth and final installment in the DOE–IDEA series, focuses on organizational execution and how strong management practices, teamwork, and preparedness contribute to successful district energy systems. It highlights case studies from Ashley Energy and Cornell University to illustrate effective operational strategies. Ashley Energy demonstrates the importance of emergency preparedness and rapid response. After a major flood disrupted its plant, the organization restored service in under 72 hours by relying on pre-established plans, vendor relationships, and trained staff. The case emphasizes proactive contingency planning, understanding insurance processes, and empowering skilled personnel to improvise during crises. Cornell University’s example highlights the role of collaboration and transparency in long-term success. Its district energy system benefits from strong data sharing, real-time energy monitoring, and active involvement of faculty and students in system planning and innovation. This culture of teamwork and data-driven decision-making supports sustainability goals and continuous system improvement. Overall, the article shows that effective organizational execution—through preparedness, collaboration, and data transparency—is essential for maintaining reliable, efficient, and sustainable district energy systems.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Ecohydrology of urban environments

Urban watersheds include a gradient of highly managed to unmanaged ecosystems that vary in vegetation cover, built and natural drainage systems, and impervious cover. A distinct difference to undeveloped ecosystems is the dominance of material and energy import and export, the disruption of natural catenae, the covariation of soils, terrain and canopy conditions. In this chapter, we discuss the distinct characteristics of urban ecohydrology compared to non-urban systems. We also investigate emergent principles of unmanaged watersheds that underscore the promotion of ecohydrological resilience, and the need to abstract and adapt these principles to support the goal-oriented restoration of impaired urban ecosystems.

42 ENGINEERING↗