Search NASA⌕ Search

SEARCH · Search NASA

Results for “Dynamic phasor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Time Series Classification for Locating Forced Oscillation Sources

Here, this article presents a machine learning based time-series classification method for using synchrophasor measurements to locate the source of forced oscillation (FO) for fast disturbance removal. First, multivariate time series (MTS) matrices are constructed by the most informative measurements selected by sequential feature selection from each power plant. Then, the Mahalanobis matrix is trained such that the Mahalanobis distance between the MTSs from the same class (i.e., with the same FO source location) are minimized and from different classes (i.e., with different FO source locations) are maximized. This allows MTSs to be classified by classifiers with class membership corresponding to the location of each FO source. To meet the runtime requirements of online matching, class templates are constructed to reduce data size and improve matching efficiency. To account for uncertainty in identifying the exact beginning of an FO event, dynamic time warping is used to align the out-of-sync MTSs. IEEE 39bus and WECC 179bus systems are used for algorithm development and validation. Simulation results demonstrate that the algorithm meets online operation runtime requirement with high accuracy using misaligned data sets.

42 ENGINEERING↗

Precise time dissemination and applications development on the Bonneville Power Administration system

The Bonneville Power Administration (BPA) uses IRIG-B transmitted over microwave as its primary system time dissemination. Problems with accuracy and reliability have led to ongoing research into better methods. BPA has also developed and deployed a unique fault locator which uses precise clocks synchronized by a pulse over microwaves. It automatically transmits the data to a central computer for analysis. A proposed system could combine fault location timing and time dissemination into a Global Position System (GPS) timing receiver and close the verification loop through a master station at the Dittmer Control Center. Such a system would have many advantages, including lower cost, higher reliability, and wider industry support. Test results indicate the GPS has sufficient accuracy and reliability for this and other current timing requirements including synchronous phase angle measurements. A phasor measurement system which provides phase angle has recently been tested with excellent results. Phase angle is a key parameter in power system control applications including dynamic braking, DC modulation, remedial action schemes, and system state estimation. Further research is required to determine the applications which can most effectively use real-time phase angle measurements and the best method to apply them.

K. E. Martin↗

Recent Development of Frequency Estimation Methods for Future Smart Grid

The frequency estimated by the Phasor Measurement Unit (PMU) is a critical index of power system status and supports many smart grid applications. The future smart grid features high penetration of renewables and more fast-moving power electronics inverters but raises challenges to the reliable frequency estimation. This article presents three methods to address these challenges. First, an enhanced zero-crossing algorithm was developed to track the fast-changing frequency in system dynamics. Second, we propose a technology that can tolerate the system transient and suppress the outliers. Third, an algorithm was developed to export high time-resolution frequency estimations with minimum computational effort. All of the proposed methods are realized in hardware and compared with classical frequency estimation methods. The testing results indicate that the proposed methods have excellent performance. They can be used in future PMUs and provide reliable and high time resolution data for smart grid applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Multi-View Convolutional Neural Network for Data Spoofing Cyber-Attack Detection in Distribution Synchrophasors

Security of Distribution Synchrophasors Data (DSD) is of paramount importance as the data is used for critical smart grid applications including situational awareness, advanced protection, and dynamic control. Unfortunately, the DSD are attractive targets for malicious attackers aiming to damage grid. Data spoofing is a new class of deceiving attack, where the DSD of one Phasor Measurement Units (PMUs) is tampered by other PMUs thereby spoiling measurement based applications. In order to address this issue, a source authentication based data spoofing attack detection method is proposed using Multi-view Convolutional Neural Network (MCNN). First, common components embedded in raw frequency measurements from DSD are removed by Savitzky-Golay (SG) filter. Second, fast S transform (FST) is utilized to extract representative spatial fingerprints via time frequency analysis. Third, the spatial fingerprint is fed to MCNN, which combines dilated and standard convolutions for automatic feather extraction and source identification. Finally, according to the output of MCNN, spoofing attack detection is performed via threshold criterion. Extensive experiments with actual DSD from multiple locations in FNET/Grideye are conducted to verify the effectiveness of the proposed method.

97 MATHEMATICS AND COMPUTING↗

Rapid Event Detection via Synchro-Waveform Based Temporal Attention Network in Distributed Grid

Compared with the information collected from phasor measurement units, synchro-waveforms contain high-fidelity disturbances of the grid, which can be a granular and authentic representation of measurements in the modern power system. However, the dynamic changing morphology makes it challenging to effectively capture various disturbance information from the synchro-waveforms. To tackle this issue, this paper proposes a Synchro-waveform based Temporal Attention (STA) network to achieve rapid event detection. First, a multi-scenario distributed model with renewable integration is established to generate synchro-waveforms under various uncertainties. Then, three typical temporal features are extracted directly from the synchro-waveform measurements. Additionally, the lightweight STA network is deployed to identify the most common event types in renewable energy systems via the self-attention based vision transformer module. The results from simulated experiments demonstrate that the proposed approach can achieve rapid and real-time detection within 0.81 ms and over 96.27 % accuracy.

Dong, Yuqing [University of Tennessee (UT)]↗

Online Output-Based Inertia Estimation of Modern Power Systems

The overall inertia of modern power systems is drastically impacted by the penetration level of converter-based resources (CBRs). The intermittent output of CBRs and their dependence on the weather conditions affirm the need for a realtime inertia estimation approach. This can help the transmission system operators(TSOs) to be continuously aware of the changes in the system inertia and to take suitable control actions. This paper is a step forward to a totally data-driven framework for power system inertia estimation using the available measurements from the phasor measurement units (PMUs). This inertia estimation is done based on the spectral analysis of the so-called Koopman linear operator. Koopman operator considers the relationship between the system's inertia and its dynamical response to slight disturbances in the load. Simulation results show that Koopman operator can approximate the system behavior in a reconstructed linear space hence inertia constant is estimated accurately.

data-driven↗

Development and Integration of an Advanced Stirling Convertor Linear Alternator Model for a Tool Simulating Convertor Performance and Creating Phasor Diagrams

A simple model of the Advanced Stirling Convertors (ASC) linear alternator and an AC bus controller has been developed and combined with a previously developed thermodynamic model of the convertor for a more complete simulation and analysis of the system performance. The model was developed using Sage, a 1-D thermodynamic modeling program that now includes electro-magnetic components. The convertor, consisting of a free-piston Stirling engine combined with a linear alternator, has sufficiently sinusoidal steady-state behavior to allow for phasor analysis of the forces and voltages acting in the system. A MATLAB graphical user interface (GUI) has been developed to interface with the Sage software for simplified use of the ASC model, calculation of forces, and automated creation of phasor diagrams. The GUI allows the user to vary convertor parameters while fixing different input or output parameters and observe the effect on the phasor diagrams or system performance. The new ASC model and GUI help create a better understanding of the relationship between the electrical component voltages and mechanical forces. This allows better insight into the overall convertor dynamics and performance.

Metscher, Jonathan F.↗

Development and Integration of an Advanced Stirling Convertor Linear Alternator Model for a Tool Simulating Convertor Performance and Creating Phasor Diagrams

A simple model of the Advanced Stirling Convertors (ASC) linear alternator and an AC bus controller has been developed and combined with a previously developed thermodynamic model of the convertor for a more complete simulation and analysis of the system performance. The model was developed using Sage, a 1-D thermodynamic modeling program that now includes electro-magnetic components. The convertor, consisting of a free-piston Stirling engine combined with a linear alternator, has sufficiently sinusoidal steady-state behavior to allow for phasor analysis of the forces and voltages acting in the system. A MATLAB graphical user interface (GUI) has been developed to interface with the Sage software for simplified use of the ASC model, calculation of forces, and automated creation of phasor diagrams. The GUI allows the user to vary convertor parameters while fixing different input or output parameters and observe the effect on the phasor diagrams or system performance. The new ASC model and GUI help create a better understanding of the relationship between the electrical component voltages and mechanical forces. This allows better insight into the overall convertor dynamics and performance.

Metscher, Jonathan F.↗

Data-Driven Adaptive Damping Controller for Wind Power Plants with Doubly-Fed Induction Generators

This paper presents an adaptive damping controller for wind power plants in which the turbines are equipped with doubly-fed induction generators. The controller is designed to respond to an input control signal that is triggered according to the system operating conditions. A processing unit continuously estimates the electromechanical modes of oscillation based on real-time streaming data acquired from a phasor measurement unit that is strategically positioned on the grid. The decision to trigger (or not trigger) the control signal is automatic, based on the relative damping of the dominant mode. The modes are estimated using the dynamic mode decomposition algorithm with time-delay embedding. Numerical simulations performed on the two-area system demonstrate that the proposed controller enhances the rotor angle stability for both small-signal and large disturbances, and is adaptive to changing grid conditions.

damping controller↗

Data-Driven Adaptive Damping Controller for Wind Power Plants with Doubly-Fed Induction Generators: Preprint

This paper presents an adaptive damping controller for wind power plants in which the turbines are equipped with doubly-fed induction generators. The controller is designed to respond to an input control signal that is triggered according to the system operating conditions. A processing unit continuously estimates the electromechanical modes of oscillation based on real-time streaming data acquired from a phasor measurement unit that is strategically positioned on the grid. The decision to trigger (or not trigger) the control signal is automatic, based on the relative damping of the dominant mode. The modes are estimated using the dynamic mode decomposition algorithm with time-delay embedding. Numerical simulations performed on the two-area system demonstrate that the proposed controller enhances the rotor angle stability for both small-signal and large disturbances, and is adaptive to changing grid conditions.

61 RADIATION PROTECTION AND DOSIMETRY↗

Guest Editorial: Advanced Data-Analytics for Power System Operation, Control, and Enhanced Situational Awareness

Along with the smart grid development, modern power systems are entering a ‘data-intensive’ era. A vast volume of data from power grids is being collected through advanced sensing and communication technologies, such as smart metering data, phasor measurement data, as well as meteorological data (e.g., wind speed and solar irradiance) related to renewable power generation. Such data contains comprehensive information about the power system covering equipment's health status, power grid's static and dynamic characteristics, renewable power generation, customers’ electricity usage pattern, etc. Therefore, advanced data-analytics techniques are needed to convert such data to knowledge for practical applications. In line with the trend of widespread data-driven applications in power systems, this Special Issue aims to present state-of-the-art research works on advanced data-analytics for power system's operation, control, and situational awareness. There are in total twenty-six papers accepted for publication in this Special Issue through careful peer reviews and revisions. Under the overarching theme of data-driven applications in power systems, the selected papers are broadly categorised into five topics. The summary of every topic is given below. You are, however, strongly encouraged to read the full paper if interested.

Xu, Yan↗

A robust dynamic state estimation approach against model errors caused by load changes

Dynamic state estimation (DSE) plays an important role in power system security monitoring and online control. In practice, there are two approaches to implementing DSE. The first approach is distributed DSE, which is based on the assumption that the terminal bus of each generator can be measured by PMUs (phasor measurement units). The assumption cannot be satisfied currently, however, because PMUs usually are installed at important high-voltage buses such as 500-kV buses installed in portions of the grid overseen by the Western Electricity Coordinating Council. Another issue of this approach is that performance of DSE is vulnerable to bad measurement data. The reason for this vulnerability is that DSE is performed separately through measurements at each terminal bus, and measurements at terminal buses are the only measurement upon which DSE can rely. Therefore, important redundant measurements are not included in this approach. The second approach is centralized DSE. This approach does not have the requirement for PMU location, and redundant measurements can be considered fully. However, load changes and grid topology changes impact centralized DSE. In this paper, we propose a new approach for handling the impact of load changes on DSE. We have developed a new algorithm that includes two sequential steps. In the first step, errors caused by load changes are detected by analyzing the difference between prediction results and measured results. In the second step, once model error is detected, a model optimization procedure is run to correct the error so the state estimation error can be mitigated. Simulation results from the IEEE 68 bus system show that the proposed approach can effectively handle model errors caused by load changes.

robust dynamic state estimation, load change, powe↗

A Participation Factor-Based Approach for Defining the EMT Model Boundary for Power System Simulations with Inverter-Based Resources

The increasing penetration of inverter-based resources (IBRs) introduces new challenges to power system simulations, particularly with the emergence of fast electromagnetic transient (EMT) dynamics and sub-synchronous oscillations (SSO) that require time-consuming EMT simulations. To reduce the time cost for simulating a large-scale power grid with IBRs, this paper proposes a novel participation factor-based approach for defining a critical zone for detailed EMT modeling and simulations, which includes the IBRs, synchronous generators, and the network components participating significantly in simulated contingencies. Both model-based and response-based methods are introduced for the estimation of participation factors (PFs). The case study on the 240-bus Western Electricity Coordinating Council (WECC) system demonstrates that the EMT zone determined by the proposed approach can effectively capture power system dynamics involving IBRs.

EMT simulation↗

An Experiment-based Distribution Level Performance Comparison among PMUs

This paper presents a experiment-based distribution level performance comparison among three Phasor Measurement Units (PMUs). Several evaluation criteria, including the total vector error, the phase angle error, the frequency error, the rate of change of frequency, the response time, the settling time, the overshoot, and the algorithm window size, are selected to compare the static and dynamic performances of the PMUs under steady state and step response test conditions. In order to have a more realistic test environment, a test is setup in which PMUs under evaluation have exactly the same input signals. The quantitative experiment result analysis gives an end-user guideline to the PMU selection regarding distribution level applications.

Yin, He↗

Development and experimental test of an analytical model of the orifice pulse tube refrigerator

An analytical model for the orifice pulse tube is developed, in which the system is described in terms of average enthalpy flow with such simplifying assumptions as an ideal gas and sinusoidal pressure variation. Phasor analysis is used to represent temperature, pressure, and mass-flow rate waves in vector form. The model predictions, namely, that the refrigeration power of a pulse-tube refrigerator is proportional to the average pressure, the pulse frequency, the mass-flow ratio, and the square of the dynamic pressure ratio, were verified by experimental measurements. It was found that, as a result of the simplifying assumptions, the magnitudes of the refrigeration power predicted by the model were between three and five times greater than experimental values.

Storch, Peter J.↗

Bayesian High-Rank Hankel Matrix Completion for Nonlinear Synchrophasor Data Recovery

Phasor measurement units (PMUs) provide high temporal-resolution synchrophasor measurements for power system monitoring and control. The frequent data quality issues, such as missing and bad data, prevent the incorporation of synchrophasor data in real-time operations. Most existing data-driven data recovery methods assume the power system dynamics can be approximated by a linear dynamical system, and the recovery performance degrades significantly when the power system is experiencing nonlinear dynamics during significant events. Here, this paper proposes a data-driven Bayesian nonlinear synchrophasor data recovery method (Ba-NSDR) that can recover a consecutive time period of simultaneous data losses or errors across all channels, even when the underlying system is highly nonlinear. The idea is to lift the Hankel matrix of the spatial-temporal synchrophasor data to a higher dimension such that the lifted Hankel matrix is low-rank in that space and can be processed with the kernel trick. Our proposed Bayesian method then infers the probabilistic distributions of synchrophasor from the partial observations. Some distinctive features of Ba-NSDR include an uncertainty index to measure the accuracy of the recovery result and the robustness to parameter selections. Our method is verified on both synthetic and recorded event datasets.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluating Methods for Measuring Grid Frequency in Low-Inertia Power Systems: Preprint

Accurate measurement of grid frequency is a critical component of reliable grid control. Traditionally, methods such as phase locked loops (PLLs) and discrete Fourier transforms (DFTs) have been used in inverters and phasor measurement units (PMUs) to measure frequency. However, as the percentage of inverter-based resources (IBRs) such as solar and wind has increased, these conventional frequency measurement methods are proving unable to guarantee reliable control in some cases. One challenge is measuring frequency during transient events, where there is a disruption in the steady state sinusoidal voltage. During these events, the underlying frequency of the grid may barely change, but measurement methods report a large spike in frequency due to the disrupted waveform. New methods must balance between suppressing spikes in frequency during faults, and providing fast, accurate, measurements in all other grid operation conditions, especially during events with high rate-of-change-of frequency (ROCOF), which are more prevalent in high-IBR power systems. This paper first surveys frequency measurement methods that have been proposed to reduce measurement errors during transient events. Then, both conventional and more novel frequency measurement methods are tested against an IEEE standard and industry recommendations, and their performance is evaluated for events simulated in PSCAD. Results quantify the trade-offs in performance during different grid conditions and lead to suggestions for the most appropriate frequency and ROCOF measurement methods for low inertia grids.

frequency↗

Using Distributed Dynamic Voltage Restorers to Improve the Frequency Stability of Low-Inertia Networked Microgrids

This paper elucidates the novel concept of using distributed dynamic voltage restorers (DVRs), which are traditionally used to compensate for voltage sags, to improve the frequency stability of low-inertia networked microgrids. During frequency transients, the distributed DVRs rapidly regulate load voltages within an acceptable range, resulting in a fast change of load power consumption and helping improve frequency stability. To enable large-scale network simulation, a phasor-based model of DVRs is developed and validated against real data from a commercially available device. Finally, simulation results of a modified IEEE 123-node test feeder that comprises three microgrids and six DVRs verify the effectiveness of the proposed method.

Du, Wei↗