Search NASA⌕ Search

SEARCH · Search NASA

Results for “Explosive detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Quantum control for initiation and detection of explosives

We employ quantum control methods towards detection and quantum controlled initiation (QCI) of energetic materials. Ultrafast pulse shaping of broadband Infrared ({approx}750 nm to 850 run) and ultraviolet (266 nm, 400 nm) light is utilized for control. The underlying principals behind optimal control can be utilized to both detect and initiate explosives. In each case, time dependent phase shaped electric fields drive the chemical systems towards a desired state. For optimal dynamic detection of explosives (ODD-Ex) a phase specific broadband infrared pulse is created which increases not only the sensitivity of detection but also the selectivity of an explosive's spectral signatures in a background of interferents. QCI on the other hand, seeks to initiate explosives by employing shaped ultraviolet light. QCI is ideal for use with explosive detonators as it removes the possibility of unintentional initiation from an electrical source while adding an additional safety feature, initiation only with the proper pulse shape. Quantum control experiments require: (1) the ability to phase and amplitude shape the laser pulse and (2) the ability to effectively search for the pulse shape which controls the reaction. In these adaptive experiments we utilize both global and local optimization search routines such as genetic algorithm, differential evolution, and downhill simplex. Pulse shaping the broadband IR light, produced by focusing 800 nm light through a pressurized tube of Argon, is straightforward as commercial pulse shapers are available at and around 800 nm. Pulse shaping in the UV requires a home built shaper. Our system is an acoustic optical modulator (AOM) pulse shaper in which consists of a fused silica AOM crystal placed in the Fourier plane of a 4-f zero dispersion compressor.

66↗

Ultraviolet Resonant Raman Enhancements in the Detection of Explosives

Raman-based spectroscopy is potentially militarily useful for standoff detection of high explosives. Normal (non-resonance) and resonance Raman spectroscopies are both light scattering techniques that use a laser to measure the vibrational spectrum of a sample. In resonance Raman, the laser is tuned to match the wavelength of a strong electronic absorbance in the molecule of interest, whereas, in normal Raman the laser is not tuned to any strong electronic absorbance bands. The selection of appropriate excitation wavelengths in resonance Raman can result in a dramatic increase in the Raman scattering efficiency of select band(s) associated with the electronic transition. Other than the excitation wavelength, however, resonance Raman is performed experimentally the same as normal Raman. In these studies, normal and resonance Raman spectral signatures of select solid high explosive (HE) samples and explosive precursors were collected at 785 nm, 244 nm and 229 nm. Solutions of PETN, TNT, and explosive precursors (DNT & PNT) in acetonitrile solvent as an internal Raman standard were quantitatively evaluated using ultraviolet resonance Raman (UVRR) microscopy and normal Raman spectroscopy as a function of power and select excitation wavelengths. Use of an internal standard allowed resonance enhancements to be estimated at 229 nm and 244 nm. Investigations demonstrated that UVRR provided ~2000-fold enhancement at 244 nm and ~800-fold improvement at 229 nm while PETN showed a maximum of ~25-fold at 244 nm and ~190-fold enhancement at 229 nm solely from resonance effects when compared to normal Raman measurements. In addition to the observed resonance enhancements, additional Raman signal enhancements are obtained with ultraviolet excitation (i.e., Raman scattering scales as !4 for measurements based on scattered photons). A model, based partly on the resonance Raman enhancement results for HE solutions, is presented for estimating Raman enhancements for solid HE samples.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Lithologic controls on microfracturing from legacy underground nuclear explosions

Detection and verification of underground nuclear explosions (UNEs) can be improved with a better understanding of the nature and extent of explosion-induced damage in rock and the effect of this damage on radionuclide migration. Much of the previous work in this area has focused on centimeter- to meter-scale manifestations of damage, but to predict the effect of damage on permeability for radionuclide migration, observations at smaller scales are needed to determine deformation mechanisms. Based on studies of tectonic deformation in tuff, we expected that the heterogeneous tuff layers would manifest explosion-induced damage differently, with welded tuffs showing more fractures and nonwelded tuffs showing more deformation bands. In comparing post-UNE samples with lithologically matched pre-UNE equivalents, we observed damage in multiple lithologies of tuff through quantitative microfracture densities. We find that the texture (e.g., from deposition, welding, alteration, etc.) affects fracture densities, with stronger units fracturing more than weaker units. While we see no evidence of expected deformation bands in the nonwelded tuffs, we do observe, as expected, much larger microfracture densities at close range (<50 m) to the explosive source. We also observe a subtle increase in microfracture densities in post-UNE samples, relative to pre-UNE equivalents, in all lithologies and depths. The fractures that are interpreted to be UNE-induced are primarily transgranular and grain-boundary microfractures, with intragranular microfracture densities being largely similar to those of pre-UNE samples. This work has implications for models of explosion-induced damage and how that damage may affect flow pathways in the subsurface.

58 GEOSCIENCES↗

Detecting Large Explosions With Machine Learning Models Trained on Synthetic Infrasound Data

Explosions produce low-frequency acoustic (infrasound) waves capable of propagating globally, but the spatio-temporal variability of the atmosphere makes detecting events difficult. Machine learning (ML) is well-suited to identify the subtle and nonlinear patterns in explosion infrasound signals, but a previous lack of ground-truth data inhibited training of generalized models. We introduce a physics-based method that propagates infrasound sources through realistic atmospheres to create 28,000 synthetic events, which are used to train ML classifiers. A simple artificial neural network and modern temporal convolutional network discriminate synthetic events from background noise with >90% accuracy and, more importantly, successfully identify the majority of real-world explosion signals recorded during the Humming Road Runner experiment. ML models trained entirely on physics-based synthetics advance explosion detection capabilities and make ML more viable to related fields lacking training data.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Method and system for detecting an explosive

A method and system for detecting at least one explosive in a vehicle using a neutron generator and a plurality of NaI detectors. Spectra read from the detectors is calibrated by performing Gaussian peak fitting to define peak regions, locating a Na peak and an annihilation peak doublet, assigning a predetermined energy level to one peak in the doublet, and predicting a hydrogen peak location based on a location of at least one peak of the doublet. The spectra are gain shifted to a common calibration, summed for respective groups of NaI detectors, and nitrogen detection analysis performed on the summed spectra for each group.

Reber, Edward L↗

Visible Hyperspectral Imaging for Standoff Detection of Explosives on Surfaces

There is an ever-increasing need to be able to detect the presence of explosives, preferably from standoff distances. This paper presents an application of visible hyperspectral imaging using anomaly, polarization and spectral identification approaches for the standoff detection (13 meters) of nitroaromatic explosives on realistic painted surfaces based upon the colorimetric differences between tetryl and TNT which are enhanced by solar irradiation.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

A range muon tomography performance study for the detection of explosives

Soft cosmic ray tomography has been shown to successfully discriminate materials with various density levels due to their ability to deeply penetrate matter, allowing sensitivity to atomic number, radiation length and density. Because the multiple muon scattering signal from high Z-materials is very strong, the technology is well suited to the detection of the illicit transportation of special and radiological nuclear materials. In addition, a recent detection technique based on measuring the lower energy particles that do not traverse the material (range radiography), allows to discriminate low and medium Z-materials. This is shown in [4] using Monte Carlo simulations. More recently, using a mini muon tracker developed at Los Alamos National Laboratory, we performed various experiments to try out the radiation length technology. This paper presents the results from real experiments and evaluates the likelihood that soft cosmic ray tomography may be applied to detect high-explosives.

36 MATERIALS SCIENCE↗

Device for Detection of Explosives, Nuclear and Other Hazardous Materials in Luggage and Cargo Containers

Device for detection of explosives, radioactive and heavily shielded nuclear materials in luggage and cargo containers based on Nanosecond Neutron Analysis/Associated Particles Technique (NNA/APT) is under construction. Detection module consists of a small neutron generator with built-in position-sensitive detector of associated alpha-particles, and several scintillator-based gamma-ray detectors. Explosives and other hazardous chemicals are detected by analyzing secondary high-energy gamma-rays from reactions of fast neutrons with materials inside a container. The same gamma-ray detectors are used to detect unshielded radioactive and nuclear materials. An array of several neutron detectors is used to detect fast neutrons from induced fission of nuclear materials. Coincidence and timing analysis allows one to discriminate between fission neutrons and scattered probing neutrons. Mathematical modeling by MCNP5 and MCNP-PoliMi codes was used to estimate the sensitivity of the device and its optimal configuration. Comparison of the features of three gamma detector types--based on BGO, NaI and LaBr{sub 3} crystals is presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improved reconstruction and sensing techniques for personnel screening in three-dimensional cylindrical millimeter-wave portal scanning

The cylindrical millimeter-wave imaging technique, developed at Pacific Northwest National Laboratory (PNNL) and commercialized by L-3 Communications/Safeview in the ProVision system, is currently being deployed in airports and other high security locations to meet person-borne weapon and explosive detection requirements. While this system is efficient and effective in its current form, there are a number of areas in which the detection performance may be improved through using different reconstruction algorithms and sensing configurations. PNNL and Northeastern University have teamed together to investigate higher-order imaging artifacts produced by the current cylindrical millimeter-wave imaging technique using full-wave forward modeling and laboratory experimentation. Based on imaging results and scattered field visualizations using the full-wave forward model, a new imaging system is proposed. The new system combines a multistatic sensor configuration with the generalized synthetic aperture focusing technique (GSAFT). Initial results show an improved ability to image in areas of the body where target shading, specular and higher-order reflections cause images produced by the monostatic system difficult to interpret.

99 GENERAL AND MISCELLANEOUS↗

Advancing Aviation Security

Air travel is a popular mode of transportation. Each year, more than 600 million people board U.S. flights for business or pleasure. As demonstrated on 9/11, a coordinated terrorist strike on commercial airlines has devastating consequences where many lives could be lost and the nation’s economy could be crippled. The Transportation Security Administration (TSA) has worked diligently to enhance security at airports and on flights so that people and cargo can continue to move freely. Today, all passengers and every piece of checked or carry-on luggage are screened before they are permitted on an aircraft. X-ray systems and walk-through metal detectors allow security personnel to identify dangerous metal objects, such as guns and knives. A more complex problem is the detection of explosives, where detection technologies such as multiple-energy X-ray radiography, computed tomography (CT), full body scanners using millimeter wave and X-ray backscatter and other techniques are used to screen for explosives hidden in luggage, in cargo and on the people boarding the aircraft. Scientists and engineers at the Lawrence Livermore National Laboratory (LLNL) are working with the Department of Homeland Security (DHS), Science and Technology Directorate (S&T), Explosives Division (EXD) to help improve aviation security by evaluating and enhancing the performance of next-generation explosives detection technologies. LLNL is providing subject matter expertise to TSA for their multi-billion dollar procurements of explosive detection system (EDS) for the nation’s airports and provides recommendations for process and system improvements. To further improve aviation security, EXD is funding research at LLNL to develop advanced explosives detection technologies that can more accurately discriminate between a wide range of explosives and non-threat materials. One challenge with scanning for explosives is that some nonthreatening materials share similar characteristics with actual threats, leading to false positives or false alarms. When an alarm is generated, security personnel must review the scan images to clear the alarm or manually open and verify the bag’s contents, which can increase labor costs and lead to passenger delays. The Livermore efforts currently focus on CT-based applications. First developed for the medical field as a method for diagnosing disease, X-ray CT has become instrumental in various industrial Non-Destructive Evaluation (NDE) applications. Explosives detection equipment that incorporates CT uses a broad-spectrum X-ray beam to capture projections of an object, in particular, the objects inside a piece of luggage. The CT system then applies complex reconstruction algorithms to the projections to produce a three-dimensional representation of the luggage and its contents. Automated threat-detection algorithms (also referred to as threat-recognition algorithms) further process the images to separate each item and flag potential threats for further review (see Figure 1). Transportation security officers can then examine these images and the relevant data to determine whether further interrogation is needed. LLNL has also performed research on advanced X-ray carry-on bag inspection systems and is helping to better understand the performance of X-ray backscatter and millimeter wave passenger screening systems.

42 ENGINEERING↗

Detection of explosives, nerve agents, and illicit substances by zero-energy electron attachment

The Reversal Electron Attachment Detection (READ) method, developed at JPL/Caltech, has been used to detect a variety of substances which have electron-attachment resonances at low and intermediate electron energies. In the case of zero-energy resonances, the cross section (hence attachment probability and instrument sensitivity) is mediated by the so-called s-wave phenomenon, in which the cross sections vary as the inverse of the electron velocity. Hence this is, in the limit of zero electron energy or velocity, one of the rare cases in atomic and molecular physics where one carries out detection via infinite cross sections.

vapor detection explosives electron detachment↗

Apparatus and methods for real-time detection of explosives devices

The present disclosure relates, according to some embodiments, to apparatus, devices, systems, and/or methods for real-time detection of a concealed or camouflaged explosive device (e.g., EFPs and IEDs) from a safe stand-off distance. Apparatus, system and/or methods of the disclosure may also be operable to identify and/or spatially locate and/or detect an explosive device. An apparatus or system may comprise an x-ray generator that generates high-energy x-rays and/or electrons operable to contact and activate a metal comprised in an explosive device from a stand-off distance; and a detector operable to detect activation of the metal. Identifying an explosive device may comprise detecting characteristic radiation signatures emitted by metals specific to an EFP, an IED or a landmine. Apparatus and systems of the disclosure may be mounted on vehicles and methods of the disclosure may be performed while moving in the vehicle and from a safe stand-off distance.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Inspection tester for explosives

An inspection tester that can be used anywhere as a primary screening tool by non-technical personnel to determine whether a surface contains explosives. It includes a body with a sample pad. First and second explosives detecting reagent holders and dispensers are operatively connected to the body and the sample pad. The first and second explosives detecting reagent holders and dispensers are positioned to deliver the explosives detecting reagents to the sample pad. A is heater operatively connected to the sample pad.

Haas, Jeffrey S↗

Method for selective detection of explosives in mass spectrometer or ion mobility spectrometer at parts-per-quadrillion level

A method for selective detection of volatile and non-volatile explosives in a mass spectrometer or ion mobility spectrometer at a parts-per-quadrillion level without preconcentration is disclosed. The method comprises the steps of ionizing a carrier gas with an ionization source to form reactant ions or reactant adduct ions comprising nitrate ions (NO.sub.3.sup.-); selectively reacting the reactant ions or reactant adduct ions with at least one volatile or non-volatile explosive analyte at a carrier gas pressure of at least about 100 Ton in a reaction region disposed between the ionization source and an ion detector, the reaction region having a length which provides a residence time (tr) for reactant ions therein of at least about 0.10 seconds, wherein the selective reaction yields product ions comprising reactant ions or reactant adduct ions that are selectively bound to the at least one explosive analyte when present therein; and detecting product ions with the ion detector to determine presence or absence of the at least one explosive analyte.

47 OTHER INSTRUMENTATION↗

SQUIDs vs. Faraday coils for ultlra-low field nuclear magnetic resonance: experimental and simulation comparison

Nuclear magnetic resonance (NMR) methods are widely used in medicine, chemistry and industry. One application area is magnetic resonance imaging or MRI. Recently it has become possible to perform NMR and MRI in ultra-low field (ULF) regime that requires measurement field strengths only of the order of 1 Gauss. These techniques exploit the advantages offered by superconducting quantum interference devices or SQUIDs. Our group at LANL has built SQUID based MRI systems for brain imaging and for liquid explosives detection at airports security checkpoints. The requirement for liquid helium cooling limits potential applications of ULF MRI for liquid identification and security purposes. Our experimental comparative investigation shows that room temperature inductive magnetometers provide enough sensitivity in the 3-10 kHz range and can be used for fast liquid explosives detection based on ULF NMR/MRI technique. We describe an experimental and computer simulation comparison of the world's first multichannel SQUID based and Faraday coils based instruments that are capable of performing ULF MRI for liquids identification.

42 ENGINEERING↗

Advances in explosives analysis—part I. animal, chemical, ion, and mechanical methods

The number and capability of explosives detection and analysis methods have increased substantially since the publication of the Analytical and Bioanalytical Chemistry special issue devoted to Explosives Analysis (Moore and Goodpaster, Anal Bioanal Chem 395(2):245–246, 2009). We review and critically evaluate the latest (the past five years) important advances in explosives detection, with details of the improvements over previous methods, and suggest possible avenues towards further advances in, e.g., stand-off distance, detection limit, selectivity, and penetration through camouflage or packaging. The review consists of two parts. Moreover, Part I, reviews methods based on animals, chemicals (including colorimetry, molecularly imprinted polymers, electrochemistry, and immunochemistry), ions (both ion-mobility spectrometry and mass spectrometry), and mechanical devices. Part II will review methods based on photons, from very energetic photons including X-rays and gamma rays down to the terahertz range, and neutrons.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Selective Sampling with Direct Ion Mobility Spectrometric Detection for Explosives Analysis

This study investigates the potential and limitations of a streamlined, field-deployable analytical approach that involves selective capture of explosive materials with direct analysis by ion mobility spectrometry (IMS). Selective capture of explosives was performed on deactivated quartz fiber filters impregnated with metal β-diketonate polymers. These Lewis acidic polymers selectively interact with Lewis base analytes such as explosives. The filter coupons could be directly inserted into an IMS instrument for analysis. The uptake kinetics of 2,4,6-trinitrotoluene (TNT) from a saturated atmosphere were characterized, and based on these studies, passive equilibrium sampling was applied to estimate the TNT concentration within an ammunition magazine that contained bulk TNT. Hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) uptake from a saturated environment also was examined over a one-month period. Each incremental sampling period showed increasing quantities of RDX culminating with collection of approximately 5 ng of RDX on the coupon at the end of one month. This is the first time that gas-phase uptake of RDX has been demonstrated.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗