Search NASA⌕ Search

SEARCH · Search NASA

Results for “FIELD FAILURES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

bifiPV2020 Bifacial Workshop: A Technology Overview

The virtual bifiPV Workshop was held in July 2020 to provide the solar industry with a forum for sharing and discussing research into bifacial photovoltaic (PV) technology. This report outlines major insights from the workshop to give the reader an overview of the latest developments in bifacial PV technology worldwide, from the lab to the field. Citations are drawn from this workshop unless otherwise noted. Presentations for the bifiPV2020 Workshop focused on the following areas: bifacial power plant modeling and simulation, albedo improvements, the development of encapsulants, the durability and reliability of current bifacial technologies, performance comparisons between glass-glass and glass-transparent backsheet configurations, the future of passivated emitter and rear contact (PERC) solar cells, and the growing adoption of n-type solar cells. With 650 GW total PV installed worldwide and 1 TW to come very soon, PERC is now the standard PV cell type produced en masse. However, it is already reaching 23% efficiency, the upper limit for this type of technology. PV modules breaking the 0.5-kW barrier are starting to appear, and the costs of standard PERC technology are already below 0.2 USD/Wp. In 2019, five GW of bifacial PV were installed worldwide. In 2020, the majority of bifacial installations are expected to be located in the United States, China, and Middle East and North Africa (MENA) states. N-type bifacial technologies are becoming increasingly viable and have huge potential to dominate the market in the coming years. With bifacial technology mounted on horizontal single-axis trackers (HSAT), bids below 10 USD/MWh will soon be observed in the MENA region, and later in Chile and the United States. Factory audits and reliability testing can reduce field failures by helping buyers to select producers that follow rigorous quality assurance and quality control processes.

14 SOLAR ENERGY↗

Structural fatigue test results for large wind turbine blade sections

In order to provide quantitative information on the operating life capabilities of wind turbine rotor blade concepts for root-end load transfer, a series of cantilever beam fatigue tests was conducted. Fatigue tests were conducted on a laminated wood blade with bonded steel studs, a low cost steel spar (utility pole) with a welded flange, a utility pole with additional root-end thickness provided by a swaged collar, fiberglass spars with both bonded and nonbonded fittings, and, finally, an aluminum blade with a bolted steel fitting (Lockheed Mod-0 blade). Photographs, data, and conclusions for each of these tests are presented. In addition, the aluminum blade test results are compared to field failure information; these results provide evidence that the cantilever beam type of fatigue test is a satisfactory method for obtaining qualitative data on blade life expectancy and for identifying structurally underdesigned areas (hot spots).

Faddoul, J. R.↗

Software dependability in the Tandem GUARDIAN system

Based on extensive field failure data for Tandem's GUARDIAN operating system this paper discusses evaluation of the dependability of operational software. Software faults considered are major defects that result in processor failures and invoke backup processes to take over. The paper categorizes the underlying causes of software failures and evaluates the effectiveness of the process pair technique in tolerating software faults. A model to describe the impact of software faults on the reliability of an overall system is proposed. The model is used to evaluate the significance of key factors that determine software dependability and to identify areas for improvement. An analysis of the data shows that about 77% of processor failures that are initially considered due to software are confirmed as software problems. The analysis shows that the use of process pairs to provide checkpointing and restart (originally intended for tolerating hardware faults) allows the system to tolerate about 75% of reported software faults that result in processor failures. The loose coupling between processors, which results in the backup execution (the processor state and the sequence of events) being different from the original execution, is a major reason for the measured software fault tolerance. Over two-thirds (72%) of measured software failures are recurrences of previously reported faults. Modeling, based on the data, shows that, in addition to reducing the number of software faults, software dependability can be enhanced by reducing the recurrence rate.

Lee, Inhwan↗

On-Demand Cell Internal Short Circuit Device

A device implantable in Li-ion cells that can generate a hard internal short circuit on-demand by exposing the cell to 60C has been demonstrated to be valuable for expanding our understanding of cell responses. The device provides a negligible impact to cell performance and enables the instigation of the 4 general categories of cell internal shorts to determine relative severity and cell design susceptibility. Tests with a 18650 cell design indicates that the anode active material short to the aluminum cathode current collector tends to be more catastrophic than the 3 other types of internal shorts. Advanced safety features (such as shutdown separators) to prevent or mitigate the severity of cell internal shorts can be verified with this device. The hard short success rate achieved to date in 18650 cells is about 80%, which is sufficient for using these cells in battery assemblies for field-failure-relevant, cell-cell thermal runaway propagation verification tests

Darcy, Eric↗

Data Fusion Tool for Spiral Bevel Gear Condition Indicator Data

Tests were performed on two spiral bevel gear sets in the NASA Glenn Spiral Bevel Gear Fatigue Test Rig to simulate the fielded failures of spiral bevel gears installed in a helicopter. Gear sets were tested until damage initiated and progressed on two or more gear or pinion teeth. During testing, gear health monitoring data was collected with two different health monitoring systems. Operational parameters were measured with a third data acquisition system. Tooth damage progression was documented with photographs taken at inspection intervals throughout the test. A software tool was developed for fusing the operational data and the vibration based gear condition indicator (CI) data collected from the two health monitoring systems. Results of this study illustrate the benefits of combining the data from all three systems to indicate progression of damage for spiral bevel gears. The tool also enabled evaluation of the effectiveness of each CI with respect to operational conditions and fault mode.

health monitoring↗

Failure Patterns After Hemithoracic Pleural Intensity Modulated Radiation Therapy for Malignant Pleural Mesothelioma

Purpose: We previously reported our technique for delivering intensity modulated radiation therapy (IMRT) to the entire pleura while attempting to spare the lung in patients with malignant pleural mesothelioma (MPM). Herein, we report a detailed pattern-of-failure analysis in patients with MPM who were unresectable or underwent pleurectomy/decortication (P/D), uniformly treated with hemithoracic pleural IMRT. Methods and Materials: Sixty-seven patients with MPM were treated with definitive or adjuvant hemithoracic pleural IMRT between November 2004 and May 2013. Pretreatment imaging, treatment plans, and posttreatment imaging were retrospectively reviewed to determine failure location(s). Failures were categorized as in-field (within the 90% isodose line), marginal (<90% and ≥50% isodose lines), out-of-field (outside the 50% isodose line), or distant. Results: The median follow-up was 24 months from diagnosis and the median time to in-field local failure from the end of RT was 10 months. Forty-three in-field local failures (64%) were found with a 1- and 2-year actuarial failure rate of 56% and 74%, respectively. For patients who underwent P/D versus those who received a partial pleurectomy or were deemed unresectable, the median time to in-field local failure was 14 months versus 6 months, respectively, with 1- and 2-year actuarial in-field local failure rates of 43% and 60% versus 66% and 83%, respectively (P=.03). There were 13 marginal failures (19%). Five of the marginal failures (38%) were located within the costomediastinal recess. Marginal failures decreased with increasing institutional experience (P=.04). Twenty-five patients (37%) had out-of-field failures. Distant failures occurred in 32 patients (48%). Conclusions: After hemithoracic pleural IMRT, local failure remains the dominant form of failure pattern. Patients treated with adjuvant hemithoracic pleural IMRT after P/D experience a significantly longer time to local and distant failure than patients treated with definitive pleural IMRT. Increasing experience and improvement in target delineation minimize the incidence of avoidable marginal failures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analysis of field data on computer failures

This paper emphasizes the importance of making field measurements for effective and realistic dependability evaluations. Two examples are given, both based on real data from IBM mainframes. The first evaluates the impact of the operating environment on system failure characteristics and the second shows how an accurate model depicting this interaction can be extracted from real data.

Iyer, Ravishankar K.↗

Attaining regularization length insensitivity in phase-field models of ductile failure

In this work, a cohesive phase-field model of ductile fracture in a finite-deformation setting is presented. The model is based on a free-energy function in which both elastic and plastic work contributions are coupled to damage. Using a strictly variational framework, the field evolution equations, damage kinetics, and flow rule are jointly derived from a scalar least-action principle. Particular emphasis is placed on the use of a rational function for the stress degradation that maintains a fixed effective strength with decreasing regularization length. The model is employed to examine crack growth in pure mode-I problems through the generation of crack growth resistance (J-R) curves. In contrast to alternative models, the current formulation gives rise to J-R curves that are insensitive to the regularization length. Numerical evidence suggests convergence of local fields with respect to diminishing regularization length as well.

42 ENGINEERING↗

Fill Factor Loss in Fielded Photovoltaic Modules Due to Metallization Failures, Characterized by Luminescence and Thermal Imaging

Understanding the causes of photovoltaic module failure in the field can be achieved using spatially-resolved imaging tools in combination with current-voltage (IV) characterization. We evaluate 23 field-degraded modules by comparing their IV characteristics with module images obtained by electroluminescence, photoluminescence, UV-fluorescence, and dark lock-in thermography. We identify primarily metallization failures (metallization series resistance, solder point heating, broken fingers, disrupted interconnects) in these modules that has led to a severe drop in the fill factor and up to 35% power loss over only 2 years of deployment.

14 SOLAR ENERGY↗

Field Programmable Gate Array Failure Rate Estimation Guidelines for Launch Vehicle Fault Tree Models

Today's launch vehicles complex electronic and avionics systems heavily utilize Field Programmable Gate Array (FPGA) integrated circuits (IC) for their superb speed and reconfiguration capabilities. Consequently, FPGAs are prevalent ICs in communication protocols such as MILSTD- 1553B and in control signal commands such as in solenoid valve actuations. This paper will identify reliability concerns and high level guidelines to estimate FPGA total failure rates in a launch vehicle application. The paper will discuss hardware, hardware description language, and radiation induced failures. The hardware contribution of the approach accounts for physical failures of the IC. The hardware description language portion will discuss the high level FPGA programming languages and software/code reliability growth. The radiation portion will discuss FPGA susceptibility to space environment radiation.

Al Hassan, Mohammad↗

Field Programmable Gate Array Failure Rate Estimation Guidelines for Launch Vehicle Fault Tree Models

Today's launch vehicles complex electronic and avionic systems heavily utilize the Field Programmable Gate Array (FPGA) integrated circuit (IC). FPGAs are prevalent ICs in communication protocols such as MIL-STD-1553B, and in control signal commands such as in solenoid/servo valves actuations. This paper will demonstrate guidelines to estimate FPGA failure rates for a launch vehicle, the guidelines will account for hardware, firmware, and radiation induced failures. The hardware contribution of the approach accounts for physical failures of the IC, FPGA memory and clock. The firmware portion will provide guidelines on the high level FPGA programming language and ways to account for software/code reliability growth. The radiation portion will provide guidelines on environment susceptibility as well as guidelines on tailoring other launch vehicle programs historical data to a specific launch vehicle.

Al Hassan, Mohammad↗

Failure analysis of field-failed bypass diodes

Defective bypass diodes are often found as the largest factor leading to power loss in solar modules. Here, we report on failure mechanisms by investigating shunted bypass diodes from a rooftop installation, using a combination of multiple characterizations including current–voltage analysis, thermal-runaway testing, X-ray computed tomography, lock-in thermography, focused ion-beam cross-section imaging, chemical decapsulation, optical microscopy, and scanning electron microscopy with energy-dispersive X-ray spectroscopy. Differing from static discharge typically associated with lightning strikes on modules, we found diode failure by the mechanism of thermal damage under continuous, long-term overstress in forward bias. Our conclusion is based on evidence of energy dissipated—the small to medium extent of melt-through on the Schottky diode face. The diode failure shows distortions or roughening of the Schottky diode metal-semiconductor interface with the die attach, and some failures are accompanied by die-attach solder melting. We propose that nonuniform irradiance on the modules caused diode shunting due to extended periods of heat dissipation in the modules, because modules in this string were placed in two different orientations. In contrast, a second parallel module string of the same module type on the same rooftop with a unique plane of array did not show any diode failures. The thermal damage failure of melt-through was caused by the long-term current generated by overstressing of diodes that may have had crystalline and impurity defects.

14 SOLAR ENERGY↗

Systems and methods for detecting a failure event in a field programmable gate array

An embodiment generally relates to a method of self-detecting an error in a field programmable gate array (FPGA). The method includes writing a signature value into a signature memory in the FPGA and determining a conclusion of a configuration refresh operation in the FPGA. The method also includes reading an outcome value from the signature memory.

Ng, Tak-Kwong↗

Flight Deck Design of a Hybrid Turbine/Electric Passenger Aircraft

NASA is exploring the development of a 180-passenger subsonic single engine aft turbine aircraft, The aft turbine provides electric power in a hybrid design to wing mounted electric engines, creating a highly efficient, high-bypass-ratio fan equivalent. The SUbsonic Single Aft eNgine (SUSAN) aircraft is being developed as a sustainable subsonic regional aircraft that seeks to reduce emission levels by 50% in the next few decades. Pilot-in-the-loop studies were conducted at the NASA Langley Research Center in Hampton, Virginia, to explore the flight deck design for the hybrid electric aircraft. Following modern trends in commercial aircraft flight decks with full time augmented controls and a quiet and dark philosophy, single throttle and simplified engine displays were developed for the SUSAN aircraft. The aircraft includes a single aft mounted turbine engine and 16 wing mounted electric fans. The final design was developed from feedback received during an earlier pilot-in-the-loop study where one, two, and three throttles were tested in standard airline operations, including various failures of the turbine and electric engines. Current flight deck designs normally provide control inceptors for each propulsion engine and an engine display for all primary aircraft engine parameters. With full time augmentation expected, a single throttle control with autothrottle always engaged, even during failures, is desired. Augmentation of flight controls using distributed thrust also requires full time control of the electric engines using automation. Additionally, electric engine thrust is augmented during climb based on battery state of charge. Thrust augmentation changes faster than human reaction time and therefore requires full-time automation. A pilot-in-the-loop study was conducted at the NASA Langley Research Center in Hampton, Virginia, to test the final design of the single throttle with simplified engine displays. Fourteen airline pilots evaluated the single throttle and engine display concept. Electric engine failures included one, four symmetric, and eight non-symmetric electric engine failures. The turbine engine was evaluated for complete and partial failure during critical phases of flight to include takeoff as well as enroute. Unexpected go-arounds increase workload and require significant throttle manipulation. Go-arounds were included to ensure the single throttle was usable for all phases of flight. Failures during takeoff required a return to the departure field and failures enroute required a diversion except for one and four electric engine failures as these failures did not affect aircraft flyability or range. There are currently no Part 25 aircraft certified with hybrid systems or electric engines with batteries as emergency propulsion. For turbine engine failures in the SUSAN aircraft design, range is limited to 30 minutes at full power. Battery state of charge and battery health displays were developed and tested for usability and to determine how well they supported pilot decisions for alternate airports during emergency diversions. Novel displays using shape and color were developed to provide immediate feedback when state of charge became critical. This paper details the pilot study including pilot feedback supporting the potential for increased automation and a single throttle control. Detailed recommendations are provided for a novel single throttle control and additional pilot controls to support selection of engines during start, shutdown, and engine troubleshooting procedures. This design deviates significantly from current practice of providing throttles for each propulsion engine. Engine display recommendations are provided based on pilot feedback during a guided post-evaluation interview. Battery state of charge and battery health display recommendations were collected from all airline crews. The simplified engine displays design was rated excellent as measured with a usability scale. Quantitative metrics include airspeed tracking, time to complete checklists, time to make diversion decisions and the quality of the diversion decision. Recommendations for future studies are documented with supporting research and current observations about upcoming flight deck certifications.

autothrottle↗

Flight Deck Design of a Hybrid Turbine/Electric Passenger Aircraft

NASA is exploring the development of a 180-passenger subsonic single engine aft turbine aircraft, The aft turbine provides electric power in a hybrid design to wing mounted electric engines, creating a highly efficient, high-bypass-ratio fan equivalent. The SUbsonic Single Aft eNgine (SUSAN) aircraft is being developed as a sustainable subsonic regional aircraft that seeks to reduce emission levels by 50% in the next few decades. Pilot-in-the-loop studies were conducted at the NASA Langley Research Center in Hampton, Virginia, to explore the flight deck design for the hybrid electric aircraft. Following modern trends in commercial aircraft flight decks with full time augmented controls and a quiet and dark philosophy, single throttle and simplified engine displays were developed for the SUSAN aircraft. The aircraft includes a single aft mounted turbine engine and 16 wing mounted electric fans. The final design was developed from feedback received during an earlier pilot-in-the-loop study where one, two, and three throttles were tested in standard airline operations, including various failures of the turbine and electric engines. Current flight deck designs normally provide control inceptors for each propulsion engine and an engine display for all primary aircraft engine parameters. With full time augmentation expected, a single throttle control with autothrottle always engaged, even during failures, is desired. Augmentation of flight controls using distributed thrust also requires full time control of the electric engines using automation. Additionally, electric engine thrust is augmented during climb based on battery state of charge. Thrust augmentation changes faster than human reaction time and therefore requires full-time automation. A pilot-in-the-loop study was conducted at the NASA Langley Research Center in Hampton, Virginia, to test the final design of the single throttle with simplified engine displays. Fourteen airline pilots evaluated the single throttle and engine display concept. Electric engine failures included one, four symmetric, and eight non-symmetric electric engine failures. The turbine engine was evaluated for complete and partial failure during critical phases of flight to include takeoff as well as enroute. Unexpected go-arounds increase workload and require significant throttle manipulation. Go-arounds were included to ensure the single throttle was usable for all phases of flight. Failures during takeoff required a return to the departure field and failures enroute required a diversion except for one and four electric engine failures as these failures did not affect aircraft flyability or range. There are currently no Part 25 aircraft certified with hybrid systems or electric engines with batteries as emergency propulsion. For turbine engine failures in the SUSAN aircraft design, range is limited to 30 minutes at full power. Battery state of charge and battery health displays were developed and tested for usability and to determine how well they supported pilot decisions for alternate airports during emergency diversions. Novel displays using shape and color were developed to provide immediate feedback when state of charge became critical. This paper details the pilot study including pilot feedback supporting the potential for increased automation and a single throttle control. Detailed recommendations are provided for a novel single throttle control and additional pilot controls to support selection of engines during start, shutdown, and engine troubleshooting procedures. This design deviates significantly from current practice of providing throttles for each propulsion engine. Engine display recommendations are provided based on pilot feedback during a guided post-evaluation interview. Battery state of charge and battery health display recommendations were collected from all airline crews. The simplified engine displays design was rated excellent as measured with a usability scale. Quantitative metrics include airspeed tracking, time to complete checklists, time to make diversion decisions and the quality of the diversion decision. Recommendations for future studies are documented with supporting research and current observations about upcoming flight deck certifications.

autothrottle↗