Search NASA⌕ Search

SEARCH · Search NASA

Results for “FLUORESCENCE MICROSCOPE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Magnolol inhibits migration of vascular smooth muscle cells via cytoskeletal remodeling pathway to attenuate neointima formation

Background: Increased proliferation and migration of vascular smooth muscle cells (VSMCs) contribute importantly to the formation of both atherosclerotic and restenotic lesions. The objective of this study was to investigate the effect of magnolol on VSMC migration. Methods: The proteolytic activity of matrix metalloproteinases (MMPs) in tumor necrosis factor alpha (TNF-α) stimulated VSMCs was performed by gelatin zymography. VSMC migration was assessed by wound healing and Boyden chamber methods. Collagen induced VSMC adhesion was determined by spectrofluorimeter and stress fibers formation was evaluated by fluorescence microscope. The expression of signaling molecules involved in stress fibers formation was determined by western blot. The phosphorylation of myosin light chain (MLC20) was determined by urea-glycerol polyacrylamide gel electrophoresis. Immunohistochemistry was performed to determine the expression of β1-integrin and collagen type I in the injured carotid arteries of rats on day 35 after vascular injury. Results: VSMC migration was strongly inhibited by magnolol without affecting MMPs expression. Also, magnolol inhibited β1-integrin expression, FAK phosphorylation and RhoA and Cdc42 activation to inhibit the collagen induced stress fibers formation. Moreover, magnolol inhibited the phosphorylation of MLC20. Our in vivo results showed that magnolol inhibited β1-integrin expression, collagen type I deposition and FAK phosphorylation in injured carotid arteries without affecting MMP-2 activity. Conclusions: Magnolol inhibited VSMC migration via inhibition of cytoskeletal remodeling pathway to attenuate neointima formation. General significance: This study provides a rationale for further evaluation of magnolol for the management of atherosclerosis and restenosis. - Highlights: • Magnolol strongly inhibited migration of VSMCs. • Magnolol inhibited stress fibers formation. • MLC20 phosphorylation was also inhibited by magnolol. • Anti-migratory effect of magnolol was cytoskeletal dependent. • Magnolol inhibited β1-integrin and collagen expression in vivo.

60 APPLIED LIFE SCIENCES↗

Dynamic microscale temperature gradient in a gold nanorod solution measured by diffraction-limited nanothermometry

We quantify the dynamic microscale temperature gradient in a gold nanorod solution using quantum-dot-based microscopic fluorescence nanothermometry. By incorporating CdSe quantum dots into the solution as a nanothermometer, precise temperature mapping with diffraction-limited spatial resolution and sub-degree temperature resolution is achieved. The acquired data on heat generation and dissipation show an excellent agreement with theoretical simulations. This work reveals an effective approach for noninvasive temperature regulation with localized nanoheaters in microfluidic environment.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Bead-Tracking Toolbox for MATLAB

A collection of MATLAB scripts forming a toolbox for video (frame by frame) detection and tracking of beads imaged with fluorescence microscope for estimating bead flow and location tracks. Scripts accept tiff image stacks of video frames and provide bead locations and tracked positions over frames in stack. Various utility functions are also provided to assist in data I/O. A custom solution for specific data source - specifically, the software works well for noisy/out of focus florescence microscopy images.

Rose, DerekC.↗

Multi-site evaluation of the LN34 pan-lyssavirus real-time RT-PCR assay for post-mortem rabies diagnostics

Rabies is a fatal zoonotic disease that requires fast, accurate diagnosis to prevent disease in an exposed individual. The current gold standard for post-mortem diagnosis of human and animal rabies is the direct fluorescent antibody (DFA) test. While the DFA test has proven sensitive and reliable, it requires high quality antibody conjugates, a skilled technician, a fluorescence microscope and diagnostic specimen of sufficient quality. The LN34 pan-lyssavirus real-time RT-PCR assay represents a strong candidate for rabies post-mortem diagnostics due to its ability to detect RNA across the diverse Lyssavirus genus, its high sensitivity, its potential for use with deteriorated tissues, and its simple, easy to implement design. Here, we present data from a multi-site evaluation of the LN34 assay in 14 laboratories. A total of 2,978 samples (1,049 DFA positive) from Africa, the Americas, Asia, Europe, and the Middle East were tested. The LN34 assay exhibited low variability in repeatability and reproducibility studies and was capable of detecting viral RNA in fresh, frozen, archived, deteriorated and formalin-fixed brain tissue. The LN34 assay displayed high diagnostic specificity (99.68%) and sensitivity (99.90%) when compared to the DFA test, and no DFA positive samples were negative by the LN34 assay. The LN34 assay produced definitive findings for 80 samples that were inconclusive or untestable by DFA; 29 were positive. Five samples were inconclusive by the LN34 assay, and only one sample was inconclusive by both tests. Furthermore, use of the LN34 assay led to the identification of one false negative and 11 false positive DFA results. Together, these results demonstrate the reliability and robustness of the LN34 assay and support a role for the LN34 assay in improving rabies diagnostics and surveillance.

60 APPLIED LIFE SCIENCES↗

19-LW-045 Full Length Final Report. Molecular Mechanisms of Bacterial Pathogenesis: Waging the Arms Race with Superbugs

As the current global pandemic makes abundantly clear, we need a better understanding of infectious disease to safeguard human health, the economy and global security. Modern omics techniques hold the promise of providing a comprehensive understanding of the molecular mechanisms of life, including causes of pathogenesis from infectious disease at the molecular level, but we there is a serious gap in annotation of gene function. For as much as half of the genes and gene products encoded in genomes the molecular and/or cellular function is unknown or only partially understood. Recent innovations in fluorescence microscopy for live cell imaging and genetic engineering make it possible to determine the temporal correlation between molecular events, such as a gene being expressed due to host-pathogen interaction, and cellular events, such as bacterial invasion of immune cells. This is turn allows us to gain new insight as to the molecular and cellular role of individual genes and will enable the discovery and validation of new molecular mechanisms essential for infectious disease. Knowing the molecular mechanisms of disease processes will provide new therapeutic targets or novel countermeasure strategies. We aimed to develop a lattice light sheet fluorescence microscope as a unique resource at LLNL for long time course live cell imaging experiments; to develop the reagents and cell lines needed to monitor molecular events during the course pathogenic bacteria infecting mammalian immune cells; and to demonstrate that we could capture molecular events during an infection. We fully commissioned the LLNL lattice light sheet microscope and conducted initial proof of principle imaging experiments on mammalian immune cells and pathogenic bacteria. It is clear from the experience gained that long time course live cell imaging has tremendous potential to help elucidate molecular mechanisms of host-pathogen interactions and to help annotate gene function, which would establish a basis for new countermeasures. It is also clear that if live cell imaging is to realize its full potential new data processing and analysis tools will need to be developed to facilitate analysis of molecular events within cells; new sample chambers and stages could facilitate studies with a wider range of cell and tissue types; and alternative molecular tagging methods need to be explored to enable more facile engineering of cells labeled with molecular specificity.

59 BASIC BIOLOGICAL SCIENCES↗

A Novel and Secure Pseudovirus Reporter System Based Assay for Neutralizing and Enhancing Antibody Assay Against Marburg Virus

Marburg virus (MARV) is one of the principal members of the filovirus family, which can cause fatal hemorrhagic fever in humans. There are currently no prophylactic and therapeutic drugs on the market, and the high pathogenicity and infectivity of MARV make its research highly dependent on biosafety level 4 conditions, severely hindering the development of vaccines and therapies. Therefore, the development of medicines, such as MARV serological diagnosis, vaccines, and therapeutic antibody drugs, urgently needs a safe, convenient, and biosafety level 2 detection method to measure the neutralizing activity of MARV antibodies. To this end, we report a neutralization assay relying on a Rabies virus (RABV) reverse genetic operating system. We constructed infectious clones carrying the eGFP reporter gene and the full length of the original unmodified MARV GP gene. Based on the critical parameters of phylogenetic analysis, recombinant viruses targeting representative strains in the two major MARV lineages were successfully rescued. These pseudoviruses are safe in mice, and their inability to infect cells after being neutralized by antibodies can be visualized under a fluorescence microscope. We tested the system using the neutralizing antibody MR191. MR191 can significantly block the infection of BSR cells with pseudovirus. We compared it with the traditional lentivirus-type pseudovirus system to verify the system’s credibility and obtained the same results as reported in the literature. In general, we have established a safe and visualized method for evaluating the neutralizing activity of MARV antibodies. Compared with traditional methods, it has the advantages of convenient operation, short cycle, and low cost. It is a candidate method that can replace actual viruses for a neutralization assay.

Bi, Jinhao↗

Retinal microvascular and neuronal pathologies probed in vivo by adaptive optical two-photon fluorescence microscopy

The retina, behind the transparent optics of the eye, is the only neural tissue whose physiology and pathology can be non-invasively probed by optical microscopy. The aberrations intrinsic to the mouse eye, however, prevent high-resolution investigation of retinal structure and function in vivo. Optimizing the design of a two-photon fluorescence microscope (2PFM) and sample preparation procedure, we found that adaptive optics (AO), by measuring and correcting ocular aberrations, is essential for resolving putative synaptic structures and achieving three-dimensional cellular resolution in the mouse retina in vivo. Applying AO-2PFM to longitudinal retinal imaging in transgenic models of retinal pathology, we characterized microvascular lesions with sub-capillary details in a proliferative vascular retinopathy model, and found Lidocaine to effectively suppress retinal ganglion cell hyperactivity in a retinal degeneration model. Tracking structural and functional changes at high-resolution longitudinally, AO-2PFM enables microscopic investigations of retinal pathology and pharmacology for disease diagnosis and treatment in vivo.

59 BASIC BIOLOGICAL SCIENCES↗

Effects of JP-8 Jet Fuel on Homeostasis of Clone 9 Rat Liver Cells

Chronic exposure to JP-8 and other kerosene-based petroleum distillates has been associated with hepatic, renal, neurologic, pulmonary, and immune toxicity. However, the effects of kerosene-type jet fuels on cellular homeostasis hitherto have not been reported. Fluorescence imaging using a Meridian Ultima laser scanning fluorescence microscope was used to evaluate the effect of JP-8 jet fuel on a communication competent rat liver cell line. Several endpoints of cellular function were measured including gap junctional intercellular communication (GJIC), mitochondrial and plasma membrane potential (MMP and PMP, respectively), intracellular glutathione (GSH) concentration, glutathione-S-transferase (GST) activity, and reactive oxygen species (ROS) generation. Cells were treated with JP-8 (0.01 to 2% in ethanol (EtOH)) for the following time points: 1 h, 24 h, 48 h, and analysis immediately after addition of jet fuel. GJIC analyzed directly after addition of 1% JP-8 was reduced 4.9-fold relative to EtOH-dosed control groups and further reduction (12.6-fold) was observed in cells treated for 1 h. Moreover, GJIC was not recoverable in cells treated with 1% JP-8 for 1 h and subsequently washed and incubated in fresh medium for 1 h. Significant changes in GSH content and GST activity were observed in cells analyzed directly after addition of 1% JP-8. GSH content increased in cells treated for 1 h with less than 2% JP-8 whereas treatment with 2% JP-8 for 1 h resulted in a 50% reduction in intracellular GSH relative to EtOH-dosed controls. Cells treated with 1% JP-8 for 48 h exhibited changes in GSH levels. However, higher JP-8 concentrations exhibited more pronounced changes in GSH and GST, which led to suppression of GSH synthesis. ROS increased in a dose-responsive fashion at JP-8 concentrations up to 1%, but decreased to 80% of control values at 2% and 3% JP-8. A 25% reduction in PMP was observed in cells treated for 1 h with 1% JP-8. In contrast, cells treated for 48 h with 2% JP-8 exhibited a 25% increase when compared to control. No significant changes were noted in the 0.01 and 1% treatment groups. Moreover, no significant changes were observed in MMP or intracellular calcium concentrations in cells treated with 0.01 to 2% JP-8 for up to 48 h. In summary, the most significant effects observed in the present study which may contribute to the toxicity of JP-8 jet fuel in cultured rat liver cells include effects on GJIC, ROS production, and GSH depletion at high (i.e., greater than 2%) JP-8 concentrations.

Wilson, C. L.↗

Biophotonics and Bone Biology

One of the more serious side effects of extended space flight is an accelerated bone loss. Rates of bone loss are highest in the weight-bearing bones of the hip and spine regions, and the average rate of bone loss as measured by bone mineral density measurements is around 1.2% per month for persons in a microgravity environment. It is well known that bone remodeling responds to mechanical forces. We are developing two-photon microscopy techniques to study bone tissue and bone cell cultures to better understand the fundamental response mechanism in bone remodeling. Osteoblast and osteoclast cell cultures are being studied, and the goal is to use molecular biology techniques in conjunction with Fluorescence Lifetime Imaging Microscopy (FLIM) to study the physiology of in-vitro cell cultures in response to various stimuli, such as fluid flow induced shear stress and mechanical stress. We have constructed a two-photon fluorescence microscope for these studies, and are currently incorporating FLIM detection. Current progress will be reviewed. This work is supported by the NASA John Glenn Biomedical Engineering Consortium.

Zimmerli, Gregory↗

NASA Tech Briefs, March 2005

Topics covered include: Scheme for Entering Binary Data Into a Quantum Computer; Encryption for Remote Control via Internet or Intranet; Coupled Receiver/Decoders for Low-Rate Turbo Codes; Processing GPS Occultation Data To Characterize Atmosphere; Displacing Unpredictable Nulls in Antenna Radiation Patterns; Integrated Pointing and Signal Detector for Optical Receiver; Adaptive Thresholding and Parameter Estimation for PPM; Data-Driven Software Framework for Web-Based ISS Telescience; Software for Secondary-School Learning About Robotics; Fuzzy Logic Engine; Telephone-Directory Program; Simulating a Direction-Finder Search for an ELT; Formulating Precursors for Coating Metals and Ceramics; Making Macroscopic Assemblies of Aligned Carbon Nanotubes; Ball Bearings Equipped for In Situ Lubrication on Demand; Synthetic Bursae for Robots; Robot Forearm and Dexterous Hand; Making a Metal-Lined Composite-Overwrapped Pressure Vessel; Ex Vivo Growth of Bioengineered Ligaments and Other Tissues; Stroboscopic Goggles for Reduction of Motion Sickness; Articulating Support for Horizontal Resistive Exercise; Modified Penning-Malmberg Trap for Storing Antiprotons; Tumbleweed Rovers; Two-Photon Fluorescence Microscope for Microgravity Research; Biased Randomized Algorithm for Fast Model-Based Diagnosis; Fast Algorithms for Model-Based Diagnosis; Simulations of Evaporating Multicomponent Fuel Drops; Formation Flying of Tethered and Nontethered Spacecraft; and Two Methods for Efficient Solution of the Hitting- Set Problem.

Source record↗

Automated Tracing and Segmentation Tool for Migrating Neurons in 4D Confocal Imagery

Accurate tracing and segmentation of subcellular components of migrating neurons in confocal image sequences are prerequisite steps in many neurobiology studies to understand the biological machinery behind the movement of developing neurons. In this paper, we present an automated tracking, tracing, and segmentation tool for soma, leading, and trailing process of migrating neurons in time-lapse image stacks acquired with a confocal fluorescence microscope. In our approach, we first localize each neuron in the maximum intensity projection of the first frame using manual labeling of the soma and end points of the leading and trailing process. By using each soma position at the first frame, we automatically track the somas in rest of the frames. Then, leading and trailing process are traced in each frame from the soma center to the labeled end tip of the process by using fast marching algorithm. Finally, the soma, leading and trailing processes of each neuron are segmented by using the soma center and traces as seed points, and their boundaries are separated from each other. Based on qualitative results, we demonstrate the capability to automatically track, trace, and segment the soma, leading, and trailing processes of a migrating neuron with minimal user input.

Karakaya, Mahmut↗

TH-CD-201-07: Experimentally Investigating Proton Energy Deposition On the Microscopic Scale Using Fluorescence Nuclear Track Detectors

Purpose: In order to further understand the interplay between proton physics and radiobiology it is necessary to consider proton energy deposition on the microscopic scale. In this work we used Fluorescent Nuclear Track Detectors (FNTDs) to experimentally investigate proton energy deposition, track-by-track. Methods: We irradiated 8×4×0.5mm{sup 3} FNTD chips (Landauer Inc) at seven water depths along a pristine proton Bragg peak with range=12cm. After irradiation, the FNTDs were scanned using a confocal microscope (FV1200, Olympus) with a high-power red laser and an oil-immersion objective lens (UPLSAPO60XO, NA=1.35). 10 slice image stacks were acquired with a slice-thickness of 2µm at multiple positions across each FNTD. Image-based analyses of track radius and track “mass” (integrated signal intensity) were performed using trackpy. For comparison, Monte Carlo simulated data were obtained using TOPAS and TOPAS-nBio. Results: Excellent correlation was observed between median track mass and TOPAS dose-averaged linear energy transfer. The resolution of the imaging system was determined insufficient to detect a relationship between track radius and exposure depth. Histograms of track mass (i) displayed strong repeatability across positions within an FNTD and (ii) varied in peak position and shape as a function of depth. TOPAS-nBio simulations implemented on the nanometer scale using physics lists from GEANT4-DNA yielded energy deposition distributions for individual protons and electrons scored within a virtual FNTD. Good agreement was found between these simulated datasets and the FNTD track mass distributions. Conclusion: Robust experimental measurements of the integral energy deposited by individual proton tracks can be performed using FNTDs. Monte Carlo simulations offer an exceedingly powerful approach to the quantification of proton energy deposition on the microscopic scale, but whilst they have been well validated at the macroscopic level, their microscopic validation is far from complete. Our results demonstrate that FNTD-based study can play an important role in addressing this deficit. Tracy Underwood gratefully acknowledges the support of the European Commission under an FP7 Marie Curie International Outgoing Fellowship for Career Development (#630064).

60 APPLIED LIFE SCIENCES↗

OH density, flux and loss probability measurements in a room temperature atmospheric pressure surface discharge by microscopic laser induced fluorescence

Many applications involving atmospheric pressure plasma-substrate interactions are enabled by the large fluxes of short-lived reactive species such as OH radicals to the substrate, nonetheless, the accurate measurement of radical densities and fluxes at substrates at atmospheric pressure has received little attention to date, particularly for surface ionization waves. We report the measurement of the OH density distribution in a surface discharge on a fused silica (quartz) substrate generated by an impinging atmospheric pressure plasma jet in dry and humid helium. The OH density is measured by microscopic laser induced fluorescence with a spatial resolution of 10 µm in the direction perpendicular to the quartz substrate. The measured OH diffusive flux varied for the investigated experimental conditions by almost three orders of magnitude and had a maximum value of 1.7 × 10 15 cm -2 s -1 . The corresponding surface loss probability of OH on the quartz surface was determined to be ~0.01. The high spatial resolution was required to accurately resolve the near surface gradient of OH radicals.

plasma-surface interactions↗

Probing Xylan-Specific Raman Bands for Label-Free Imaging Xylan in Plant Cell Wall

Xylan constitutes a significant portion of biomass (e.g. 22% in corn stover used in this study). Xylan is also an important source of carbohydrates, besides cellulose, for renewable and sustainable energy applications. Currently used method for the localization of xylan in biomass is to use fluorescence confocal microscope to image the fluorescent dye labeled monoclonal antibody that specifically binds to xylan. With the rapid adoption of the Raman-based label-free chemical imaging techniques in biology, identifying Raman bands that are unique to xylan would be critical for the implementation of the above label-free techniques for in situ xylan imaging. Unlike lignin and cellulose that have long be assigned fingerprint Raman bands, specific Raman bands for xylan remain unclear. The major challenge is the cellulose in plant cell wall, which has chemical units highly similar to that of xylan. Here we report using xylanase to specifically remove xylan from feedstock. Under various degree of xylan removal, with minimum impact to other major cell wall components, i.e. lignin and cellulose, we have identified Raman bands that could be further tested for chemical imaging of xylan in biomass in situ.

09 BIOMASS FUELS↗

ELM: Europa Luminescence Microscope

The Europa Luminescence Microscope (ELM) is an automated fluorescence and bright-field microscope designed to meet key objectives defined in the 2016 NASA Europa Lander Study Report, including the identification and characterization of morphological biosignatures. ELM’s heritage stems from a 2U cubesat fluorescence microscope, the Fluorescence Analysis for In situ Research imager, designed and built at NASA Ames Research Center, for the autonomous study of microbial biology in low Earth orbit. For ELM implementation, a sample is autonomously manipulated with a microfluidic system using in-line 10, 1.0, and 0.2 μm pore-size filters to capture successively smaller particles for imaging. For bright-field imaging, ELM uses deep-ultraviolet, ultraviolet and visible light to image organic and inorganic structures with submicron resolution. The ability to detect biosignatures as small as 0.2 μm in size is achieved by imaging native fluorescence and using fluorescence microscopy stains to identify key structural and functional indicators of microbial life (proteins, lipids, nucleic acids). For fluorescence imaging, ELM uses 265, 370, 470, and 530 nm LEDs with five emission bands. The use of multiple excitation and emission wavelengths for native fluorescence imaging enables the detection of a wide range of molecular species and their rough classification. Excitation at 265 nm allows for the detection of smaller polycyclic aromatic hydrocarbons (PAH), aromatic amino acids, and proteins with little to no interference from mineral fluorescence, given proper emission band selection. 370 and 470 nm light excites increasingly larger PAH structures and larger aromatic biomolecules that may be present (e.g., protective pigments). Similarly, inorganic fluorescence can be characterized and separated from organic fluorescence, allowing the recognition and in some cases classification, of minerals and other abiotic particles. ELM is based upon work supported by the NASA COLDTech and ICEE-2 programs.

Richard C Quinn↗

Closed-looped in situ nano processing on a culturing cell using an inverted electron beam lithography system

Highlights: ► An electron beam lithography (EBL) was used as an in situ nano processing for a living cell. ► A synchronized optics was containing an inverted EBL and an optical microscope. ► This system visualized real-time images of the EB-induced nano processing. ► We demonstrated the nano processing for a culturing cell with 200–300 nm resolution. ► Our system would be able to provide high resolution display of virtual environments. -- Abstract: The beam profile of an electron beam (EB) can be focused onto less than a nanometer spot and scanned over a wide field with extremely high speed sweeping. Thus, EB is employed for nano scale lithography in applied physics research studies and in fabrication of semiconductors. We applied a scanning EB as a control system for a living cell membrane which is representative of large scale complex systems containing nanometer size components. First, we designed the opposed co-axial dual optics containing inverted electron beam lithography (I-EBL) system and a fluorescent optical microscope. This system could provide in situ nano processing for a culturing living cell on a 100-nm-thick SiN nanomembrane, which was placed between the I-EBL and the fluorescent optical microscope. Then we demonstrated the EB-induced chemical direct nano processing for a culturing cell with hundreds of nanometer resolution and visualized real-time images of the scanning spot of the EB-induced luminescent emission and chemical processing using a high sensitive camera mounted on the optical microscope. We concluded that our closed-loop in situ nano processing would be able to provide a nanometer resolution display of virtual molecule environments to study functional changes of bio-molecule systems.

60 APPLIED LIFE SCIENCES↗

Workflow Using a Cryogenic Coincident Fluorescence, Electron, and Ion Beam Microscope for Targeted Milling of Cells

This workflow enables lamella production targeting fluorescently labeled biological structures that are small (<1 μm in axial extent) and rare (1 copy per cell) using a cryogenic tri-coincident imaging platform. In conclusion, this platform integrates fluorescence microscopy, focused ion beam milling, and scanning electron microscopy at a single focal position and enables simultaneous fluorescence microscopy while milling.

Wang, Jue [California Institute of Technology (Cal↗