Operational stability of rubidium and cesium frequency standards

In the course of testing various rubidium and cesium frequency standards under operational conditions for use in NASA tracking stations, about 55 unit-years of relative frequency measurements for averaging times from 10 to 10 to the 7th power have been accumulated at Goddard Space Flight Center (GSFC). Statistics on the behavior of rubidium and cesium standards under controlled laboratory conditions have been published, but it was not known to what extent the lesser controlled environments of NASA tracking stations affected the performance of the standards. The purpose of this report is to present estimates of the frequency stability of rubidium and cesium frequency standards under operational conditions based on the data accumulated at GSFC.

Lavery, J. E.↗

Trapped-Mercury-Ion Frequency Standard

Report describes principle of operation, design, and results of initial measurements on trapped-mercury-ion frequency-standard apparatus at NASA's Jet Propulsion Laboratory. New frequency standard being developed. Based on linear ion trap described in (NPO-17758). Expected to show much better short-term frequency stability because of increased ion-storage capacity.

Prestage, John D.↗

An improved offset generator developed for Allan deviation measurement of ultra stable frequency standards

Measuring the performance of ultra stable frequency standards such as the Superconducting Cavity Maser Oscillator (SCMO) necessitates improvement of some test instrumentation. The frequency stability test equipment used at JPL includes a 1 Hz Offset Generator to generate a beat frequency between a pair of 100 MHz signals that are being compared. The noise floor of the measurement system using the current Offset Generator is adequate to characterize stability of hydrogen masers, but it is not adequate for the SCMO. A new Offset Generator with improved stability was designed and tested at JPL. With this Offset Generator and a new Zero Crossing Detector, recently developed at JPL, the measurement flow was reduced by a factor of 5.5 at 1 second tau, 3.0 at 1000 seconds, and 9.4 at 10,000 seconds, compared against the previous design. In addition to the new circuit designs of the Offset Generator and Zero Crossing Detector, tighter control of the measurement equipment environment was required to achieve this improvement. The design of this new Offset Generator are described, along with details of the environment control methods used.

R. L. Hamell↗

Extended linear ion trap frequency standard apparatus

A linear ion trap for frequency standard applications is provided with a plurality of trapping rods equally spaced and applied quadruple rf voltages for radial confinement of atomic ions and biased level pins at each end for axial confinement of the ions. The trapping rods are divided into two linear ion trap regions by a gap in each rod in a common radial plane to provide dc discontinuity, thus dc isolating one region from the other. A first region for ion-loading and preparation fluorescence is biased with a dc voltage to transport ions into a second region for resonance frequency comparison with a local oscillator derived frequency while the second region is held at zero voltage. The dc bias voltage of the regions is reversed for transporting the ions back into the first region for fluorescence measurement. The dual mode cycle is repeated continuously for comparison and feedback control of the local oscillator derived frequency. Only the second region requires magnetic shielding for the resonance function which is sensitive to any ambient magnetic fields.

Prestage, John D.↗

Space Flyable Hg(sup +) Frequency Standards

We discuss a design for a space based atomic frequency standard (AFS) based on Hg(sup +) ions confined in a linear ion trap. This newly developed AFS should be well suited for space borne applications because it can supply the ultra-high stability of a H-maser but its total mass is comparable to that of a NAVSTAR/GPS cesium clock, i.e., about 11kg. This paper will compare the proposed Hg(sup +) AFS to the present day GPS cesium standards to arrive at the 11 kg mass estimate. The proposed space borne Hg(sup +) standard is based upon the recently developed extended linear ion trap architecture which has reduced the size of existing trapped Hg(sup +) standards to a physics package which is comparable in size to a cesium beam tube. The demonstrated frequency stability to below 10(sup -15) of existing Hg(sup +) standards should be maintained or even improved upon in this new architecture. This clock would deliver far more frequency stability per kilogram than any current day space qualified standard.

clocks cesium atomic frequency standard Hg ions li↗

Microwave frequency standard on {sup 25}Mg{sup +} ions: expected characteristics and prospects

A scheme of the new frequency standard is reported based on a microwave transition between hyperfine components of the ground state in {sup 25}Mg{sup +} ions. It is proposed to capture ions into a linear quadrupole Paul trap and to perform the laser cooling, as well as to prepare the particle ensemble and to implement detection by using a single laser system based on a semiconductor laser. Characteristics of the suggested frequency standard are estimated. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Evaluation of the systematic shifts of a single-{sup 40}Ca{sup +}-ion frequency standard

Progress on the evaluation of systematic frequency shifts is described in the development of the optical frequency standard based on single-trapped {sup 40}Ca{sup +} with a ''clock'' transition at 729 nm. The overall systematic uncertainty of the 4s {sup 2} S{sub 1/2}-3d {sup 2} D{sub 5/2} clock resonance has been characterized to be 7.8 x 10{sup -16}. This uncertainty is at a level similar to the Cs fountain primary standard, while the potential stability for the {sup 40}Ca{sup +} clock exceeds that of Cs.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Performance of preproduction model cesium beam frequency standards for spacecraft applications

A cesium beam frequency standards for spaceflight application on Navigation Development Satellites was designed and fabricated and preliminary testing was completed. The cesium standard evolved from an earlier prototype model launched aboard NTS-2 and the engineering development model to be launched aboard NTS satellites during 1979. A number of design innovations, including a hybrid analog/digital integrator and the replacement of analog filters and phase detectors by clocked digital sampling techniques are discussed. Thermal and thermal-vacuum testing was concluded and test data are presented. Stability data for 10 to 10,000 seconds averaging interval, measured under laboratory conditions, are shown.

Levine, M. W.↗

Frequency standards for VLBI, present and future

During the last several years, J.P.L. has evaluated a number of different types of frequency standards. These evaluations include measurement of environmetal susceptibilities (barometric pressure, humidity, temperature and magnetic field) and evaluation of stability. Data from these tests are presented for quartz oscillators, rubidium vapor standards, cesium beam standards, hydrogen masers (active and passive) and a superconducting cavity stabilized oscillator. Data on reliability and mechanical ruggedness based on actual field use is also presented. A survey of new frequency standards, their likely performance and environmental characteristics is presented.

Sydnor, R. L.↗

Note: A novel design of a microwave feed for a microwave frequency standard with a linear ion trap

Linear ion traps are important tools in many applications, particularly in mass spectrum analyzers and frequency standards. Here a novel design of a microwave feed integrated into one electrode of a linear quadrupole ion trap is demonstrated for the application of a microwave frequency standard based on cadmium ions. The mechanical structure of the microwave feed is compact and easy to build. The ion trap integrated with this microwave feed is successfully applied to measure the hyperfine splitting of the ground state of {sup 113}Cd{sup +}, thus demonstrating the practicality and reliability of the microwave feed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Derivation of the Long-Term Degradation of a Pulsed Atomic Frequency Standard from a Control-Loop Model

The phase of a frequency standard that uses periodic interrogation and control of a local oscillator (LO) is degraded by a long-term random-walk component induced by downconversion of LO noise into the loop passband. The Dick formula for the noise level of this degradation is derived from an explicit solution of an LO control-loop model.

Dick formula local oscillator frequency phase freq↗

Automated frequency standard stability data reduction

A design using a medium sized computer, a fiber optic communication link, and a desk top computer to reduce data collected at a remote site for analysis of frequency standard tests is described. Data generated at the Interim Frequency Standards Test Facility is collected on magnetic tape, which is then transported to a Sigma 5 computer. An Allan variance (two sample variance) is then calculated. The Allan variance (sigma vs tau) is then written to a data file in the Sigma 5. A fiber optic communication link between the Sigma 5 and a desk top computer was designed to transmit data in the Sigma 5 file to the desk top computer. A program was written for the desk top computer that will automatically access the data file in the Sigma 5, process the data and provide a data plot.

Knapp, L. J.↗

Laser-pumped paraffin-coated cell rubidium frequency standard

We have realized and studied a rubidium atomic frequency standard based on a paraffin-coated cell, exhibiting a short-term frequency stability <3 Multiplication-Sign 10{sup -12} {tau}{sup -1/2} between {tau} = 1 and 100 s. Characterization of the wall-coating is performed by measuring the T{sub 1} and T{sub 2} relaxation times. Perturbations of the medium- to long-term clock stability, due to variations in the laser-intensity, laser frequency, the microwave power shift, and the shifts due to temperature variations are measured and analyzed. A method for reducing the intensity light-shift by detuning the laser frequency and the resulting improvement in clock stability is demonstrated. This work is of relevance for further improvements on Rb cell standards using anti-relaxation wall-coating technology.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Application of very long baseline interferometry to Astrometry and Geodesy: effects of frequency standard instability on accuracy

The accuracy of geodetic and astrometric information obtained from very long baseline interferometry (VLBI) observations is dependent upon the stability of the frequency standard, or clock, used at each site of VLBI array. The sensitivities of two hydrogen maser frequency standards of different design to pressure, temperature, and magnetic field variations were measured; and, for one of the standards, sensitivity was found to be severe enough to degrade the information content of VLBI measurements. However, the effect on the geometric and astrometric information of such clock instabilities, with time scales of hours or greater, can be sharply reduced through the use of differencing techniques.

Clark, T. A.↗

Blackbody-radiation shift in a {sup 43}Ca{sup +} ion optical frequency standard

Motivated by the prospect of an optical frequency standard based on {sup 43}Ca{sup +}, we calculate the blackbody-radiation (BBR) shift of the 4s{sub 1/2}-3d{sub 5/2} clock transition, which is a major component of the uncertainty budget. The calculations are based on the relativistic all-order single-double method where all single and double excitations of the Dirac-Fock wave function are included to all orders of perturbation theory. Additional calculations are conducted for the dominant contributions in order to evaluate some omitted high-order corrections and estimate the uncertainties of the final results. The BBR shift obtained for this transition is 0.38(1) Hz. The tensor polarizability of the 3d{sub 5/2} level is also calculated and its uncertainty is evaluated as well. Our results are compared with other calculations.

74 ATOMIC AND MOLECULAR PHYSICS↗