Search NASASearch

SEARCH · Search NASA

Results for “Field Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

CMP Pits and D-Area Watershed Infiltrometer Testing

Savannah River National Laboratory (SRNL) conducted saturated hydraulic conductivity field testing at the Chemical, Metals, and Pesticide Pits (CMP Pits) and the D-Area watershed to develop infiltration rates for use in future updates to the CMP Pits groundwater flow model. Approximately 18 testing locations were selected at each site based on the soil series that were identified in the Soil Survey of Savannah River Plant Area, Parts of Aiken, Barnwell, and Allendale Counties, South Carolina.

54 ENVIRONMENTAL SCIENCES

CMP Pits and D-Area Watershed Infiltrometer Testing

Savannah River National Laboratory (SRNL) conducted saturated hydraulic conductivity field testing at the Chemical, Metals, and Pesticide Pits (CMP Pits) and the D-Area watershed to develop infiltration rates for use in future updates to the CMP Pits groundwater flow model. Approximately 18 testing locations were selected at each site based on the soil series that were identified in the Soil Survey of Savannah River Plant Area, Parts of Aiken, Barnwell, and Allendale Counties, South Carolina.

54 ENVIRONMENTAL SCIENCES

Testing Capabilities for Superconducting Magnets at Fermilab

This presentation will focus on the current testing capabilities for superconducting magnets at Fermilab, highlighting existing systems, recent upgrades, and future plans. The Vertical Magnet Test Facility (VMTF) remains a cornerstone for testing superconducting magnets in R&D applications, maintaining its established capabilities. Stand 4 continues to support the Hi-Lumi AUP production line of magnets in cryostats and has achieved significant improvements through a redesign of lead connections, resolving issues with liquid helium levels and resistance, culminating in a successful endurance test without interruption. Similarly, Stand 7 underwent commissioning and a lead redesign to reduce heat load, while its core testing capabilities remain unchanged. Looking forward, Stand 3 is undergoing a redesign, with plans to restart and begin commissioning by the end of 2025, introducing new features such as background magnetic field testing and upgraded power supplies. Fermilab is also advancing the High Field Vertical Magnet Test Facility (HFVMTF), designed to support the fusion and magnet R&D program, with commissioning scheduled for 2025 and critical components, including the cryostat and power supplies, being delivered. Enhancing all operations, the newly commissioned IB1 cryoplant now offers automated overnight helium production and efficient transfer to a 10,000-liter dewar, streamlining support across all test stands. This talk will provide a comprehensive overview of testing capabilities, and showcasing how Fermilab is advancing its capabilities to meet the evolving demands of superconducting magnet testing.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS

Control Strategies and Validation in the Hybrid Optimization and Performance Platform (HOPP)

The Hybrid Optimization and Performance Platform (HOPP) is a tool that simulates hybrid power plants in various configurations, and also calculates the financial feasibility of these plants. This report outlines an overview of HOPP and the energy storage dispatch strategies available. It then presents three case studies which demonstrate different applications of HOPP. The first case looks at the profitability of hybrid power plants in different locations in the USA. The second case examines the availability of hybrid power plants to provide energy reliability services. The third case presents a plant that produces both hydrogen and electricity, and demonstrates a dispatch strategy that chooses the most profitable energy vector based on price signals. The next section shows the validation of HOPP on operational data, using data from both unit-scale and utility-scale power plants. This validation process demonstrated that HOPP can simulate the power output of both wind and solar PV plants at both scales with comparable fidelity to an existing commercial software tool. Finally, HOPP is applied in a field test which applies an optimal dispatch strategy to a physical battery in a unit-scale hybrid plant at NREL. HOPP's optimal dispatch strategy, applied in a real-world setting, improved this hybrid plant's ability to meet a load signal while minimizing operational costs.

14 SOLAR ENERGY

ZIPPER: Zonal isolation with plug and perf in enhanced reservoirs (Final Technical Report)

Modern multistage hydraulic stimulation treatments in cased wellbores require an effective method of isolating stages between treatments. A commonly used method in the oil and gas industry, plug and perf, is not currently viable for Enhanced Geothermal Systems (EGS) due to limitations of a critical component of the system – the ball drop (flow through) frac plug. Commercially available ball drop frac plugs do not meet the temperature or wellbore diameter requirements needed for use in EGS stimulations. For example, one particular drillable bridge and frac plug line from a large tool developer is only rated to 175 °C, while another is only available up to casing sizes of 5 ½” and rated up to 204 °C. We developed, prototyped, and field tested an upgraded ball drop frac plug to meet the requirements of EGS stimulations, including high-temperature (225+ °C), differential pressure (6000+ psi), and wellbore diameters ranging from 6 5/8” to 10 5/8”. We focused on designs and materials to optimize drillability, a key cost driver in plug and perf systems. The primary objective was to upgrade a drillable frac plug (currently rated to a temperature of 175°C and a pressure of 10,000 psi in 7” casing) to withstand temperatures of 225+°C. The upgraded frac plug was tested in the laboratory as well as in a field trial at a geothermal field. Engineering design and fabrication of the new plug was completed in 2019. Lab testing, validation, and qualification of the plug was completed in 2020. Ultimately the plug was successfully run during a multistage stimulation treatment in a fully horizontal EGS well in 2022. Prior to this project, a ball-drop, flow-through stimulation plug had never been used in a geothermal well. At the conclusion of this project, three different types of zonal isolation plugs were evaluated under full-scale operating conditions across 16 stimulation treatment stages in a first-of-a-kind EGS project called Project Red. This trial included the newly designed high-temperature, large-diameter plug. The plugs met all of 5 the technical requirements for commercial viability. Project Red has since been fully commissioned and is generating electricity on the Nevada grid - the first EGS project to successfully deliver power to the grid in the US.

15 GEOTHERMAL ENERGY

PACT Perovskite PV Module Outdoor Test Protocol (Version 0.2)

The purpose of this protocol is to define procedures and practices to be used by the PACT center for field testing of metal halide perovskite (MHP) photovoltaic (PV) modules. The protocol defines the physical, electrical, and analytical configuration of the tests and applies equally to mounting systems at a fixed orientation or sun tracking systems. While standards exist for outdoor testing of conventional PV modules, these do not anticipate the unique electrical behavior of perovskite cells. Further, the existing standards are oriented toward mature, relatively stable products with lifetimes that can be measured on the scale of years to decades. The state of the art for MHP modules is still immature with considerable sample to sample variation among nominally identical modules. Version 0.0 of this protocol does not define a minimum test duration, although the intent is for modules to be fielded for periods ranging for weeks to months. This protocol draws from relevant parts of existing standards, and where necessary includes modifications specific to the behavior of perovskites.

14 SOLAR ENERGY

Enhanced Attenuation of Uranium in the Subsurface

Over time, the focus for the Hanford Site has moved from production to decommissioning and site remediation. Several hundred metric tons of near-surface vadose zone sediment have been excavated from the 300 Area in an effort to remove the source of the uranium contamination (DOE/RL, 2011). Despite remediation efforts, uranium continues to be problematic with concentrations greater than the maximum contaminant level (MCL, which is 30 µg/L) for drinking water. Due to the close proximity of the Columbia River, the uranium continues to be a focus of investigation and remediation. After finding that the uranium concentrations were not decreasing as quickly as expected (based on the 1996 ROD) the Tri-Parties set new milestones, including an update of the conceptual model for the 300 Area uranium plume (Williams et al., 2007). In order to more accurately complete a feasibility study and identify how to remediate the uranium in the groundwater, the DOE authorized a remedial investigation/feasibility study (RI/FS). RI/FSs are designed to screen technologies to determine effectiveness, implementability, and cost (see Chapter 2b). These studies are designed to be conducted concurrently as part of the CERCLA process, so the data collected during site characterization (part of the RI) can inform the treatability studies and field tests conducted under the FS (EPA 1988). For the 300 Area, this study included laboratory, field, and modeling components as well as additional sediment and groundwater characterization to determine a suitable remediation strategy to reduce the uranium concentration in the groundwater plume within the expected time frame and cost.

300 area, uranium, polyphosphate, Hanford book pro

Additively Manufactured Graded Composite Transition Joints for Dissimilar Metal Weldments in Advanced Ultra-Supercritical Power Plant (Final Technical Report)

In this project, we successfully achieved all the goals we proposed: ① Code Development; ② Transition Joint Design; ③ Lab-scale GCTJ Testing Piece Development; ④ Heat Treatment; ⑤ Welding of DMW; ⑥ Mechanical Characterization; ⑦ Corrosion; ⑧ Fabrication of Prototype GCTJ; ⑨In-field Test in SWRI and ⑩Tech-economic Analysis.

36 MATERIALS SCIENCE

Laboratory and field validation of the performance benefits and costs of thin triple-pane windows in residential buildings

The adoption of high-performance triple-pane windows that significantly reduce heat transfer has been slow, in part because they are thicker, heavier, and more costly than double-pane windows. One path to increase adoption of triple-pane windows is to replace the conventional double-glazing insulated glass unit (IGU) with a modified triple-glazing design that uses a very thin central pane of glass. This thinner triple-pane IGU can then be “dropped in” to the double-pane IGU pocket without requiring major modifications to frame design. The Department of Energy sponsored laboratory and field testing of thin triple-pane windows by Pacific Northwest National Laboratory. This article presents findings from both the Lab Homes study and subsequent field demonstrations carried out over a 3-year period (2020–2023). The laboratory and field studies demonstrated the manufacturing and distribution feasibility of thin triple-pane windows, successfully installed at multiple sites, using double-pane frames from four different manufacturers and thin triple-pane IGUs from two different manufacturers. Compared to a home with double-pane, clear-glass windows, testing demonstrated average whole-home heating energy savings of 12% and cooling energy savings of 27% for thin triple-pane windows. Improvements in comfort, sound insulation, and condensation potential were noted in both laboratory and field studies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Casing Annulus Monitoring of CO 2 Injection Using Wireless Autonomous Distributed Sensor Networks

Effective and secure carbon subsurface storage, involving the deep underground injection of CO 2 into geological formations where it is permanently trapped, is paramount to mitigating CO 2 emissions (Figure I). Ensuring the integrity of these storage sites and detecting potential leakage through the casing annulus necessitates robust monitoring. This work provides the first integrated demonstration of a wireless casing-annulus monitoring architecture that can operate in highly attenuating cement-brine environments relevant to CO 2 storage. This project focused on developing and validating a novel sensor system for integration with autonomous monitoring near the cement reservoir interface. The goal was a fully integrated Technology Readiness Level (TRL) 4/5 field validation of a distributed wireless intelligent sensor system providing real-time, direct subsurface formation measurements to enhance fluid movement monitoring in the cemented casing annulus. Achieving this objective required the development and integration of 1) wireless autonomous microsensor technology by California Institute of Technology (Caltech); 2) sensor packaging and emplacement technology by Research Triangle Institute (RTI); and 3) smart well completions using wireless active casing collars and NOV pipe by the Sandia National Lab (SNL). The collaboration with the Caltech team in this project aimed to develop millimeter-scale radio frequency identification (RFID) sensors capable of detecting CO 2 , pH, and/or methane levels. These sensors are engineered to be impervious to fluids, allowing them to be mixed with cement and installed within the casing annulus. They operate using RFID protocols at frequencies of 902–928 MHz for both power and communication. A Sandia National Laboratories’ team engaged their expertise in the development of a Smart Collar system designed for the wireless data collection from these RFID sensors embedded in the cement annulus and transmission of this information to the ground surface via IntelliPipe/IntelliServ NOV drill pipe. This is accomplished through inductive coupling at the collar, which facilitates data transfer through each segment of the pipe. Because the system cannot transmit a direct current signal to power the Smart Collar, both power and communication were implemented using alternating current and electromagnetic signals at varying frequencies. Furthermore, the developed microsensor technology had to be demonstrated and validated in comparison with reference transducer measurements in a field test site at The University of Texas at Austin (UT-Austin). Although the full sensor suite did not reach field-deployment readiness, the system-level integration achieved in this project establishes a validated pathway for future incorporation of advanced microsensors.

47 OTHER INSTRUMENTATION

Design of Multi-Engine Freight Locomotive

This final report documents the completed engineering design of a modular, multi-engine renewable natural gas (RNG) hybrid freight locomotive. The project delivered a full systems design, component selection, and production and test plans for a near-zero-emission, Tier 5–capable line-haul locomotive, but did not proceed to fabrication or field testing due to withdrawal of the designated engine supplier.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

A Multi-Sensor Approach for Measuring Bird and Bat Collisions with Offshore Wind Turbines (Final Technical Report)

Collision of birds and bats with wind turbines is a conservation concern for both land-based and offshore wind projects. The fatality rates of birds and bats at land-based turbines are well documented. The measurement strategies on land focus on finding carcasses following collision, estimating the number of carcasses missed through searcher efficiency, carcass persistence trials and carcass fall distributions, and modeling statistically robust fatality rates. Few technologies have been developed to monitor offshore bird and bat collisions, and many that have been developed focused on detecting collisions with large birds. The few studies that have attempted to document collisions at offshore turbines do not account for smaller bodied animals or for collisions that might be missed, which prevents the calculation of statistically robust fatality rates. The overall goal of this report, A Multi-Sensor Approach for Measuring Bird and Bat Collisions with Offshore Wind Turbines (Project), was to develop an effective multi-sensor system for quantifying bird and bat collision rates, specifically for offshore wind facilities. The Project goal and resulting automated collision detection system was achieved through two major technological advancements: 1) refining The Netherlands Organisation for Applied Scientific Research’s (TNO’s) existing WT-Bird® vibration sensing system, that had successfully detected large bird collisions during daytime, to allow for improved detection of smaller birds and bats during both daytime and nighttime hours and 2) improving image processing systems and developing and integrating machine learning algorithms to automatically detect and classify small and large bird and bat collisions with offshore turbines. This final technical report (FTR) summarizes Methods , Results , Conclusions , and Lessons Learned during each of the five Tasks identified for this research and development effort. This FTR includes summaries of the following: Task 1. Initial Engineering Tests to Improve WT-Bird® Task 2. Installation of WT‐Bird® on a Utility-scale Turbine at the National Wind Technology Center – National Renewable Energy Laboratory Task 3. Field Tests and Refinement of the Object Detection System Task 4. Validation of WT-Bird® on a Land-based Turbine Task 5. Preparation for the Implementation of WT-Bird® on an Offshore Turbine. This research and development effort documented successful improvement of the WT Bird® collision detection system to detect small birds and bats, and WT-Bird® is the first collision detection system to validate results compared to land-based post-construction monitoring. The collision trials provide estimates of missed targets that can be used to estimate fatality rates, a significant improvement relative to other offshore collision monitoring systems. Advances were made in developing an edge-processing solution to reduce data storage requirements, which is important if the system is deployed for long periods of time at offshore turbines. The improved WT-Bird® system also provides an important option for wind operators on land or offshore who need to document specific details about when collisions occur, particularly efforts to further research on bat impact minimization, or when standard fatality searches are impractical (e.g. offshore) or inadequate (e.g. challenging locations on land).

17 WIND ENERGY

Enabling CO 2 Isothermal Compression Using Liquid Piston and Integrated Gas Cooler

This report outlines the development of a near-isothermal liquid piston compressor. Initially, a proof-of-concept experiment was conducted to validate the feasibility and potential of near-isothermal compression. A first-of-its-kind near-isothermal liquid piston compressor was then successfully built and tested. Additionally, a Matlab-based transient model was developed to capture performance trends accurately. These efforts laid the groundwork for developing a second-generation prototype with enhanced efficiency and design. Subsequent field tests at the Helix Innovation Center in Ohio demonstrated a cooling capacity of 2 kW with a COP of 1.64 at an ambient temperature of 25°C. An improved model was also created to suggest different heat exchanger geometries for better compression efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Innovating the next generation of commercial smart building software

Nearly 30% of commercial building energy use is wasted due to equipment faults and HVAC controls problems. The result is increased emissions, compromised comfort and productivity, and less reliable coordination of building power needs with a clean grid. The energy impact alone represents $17 billion in potential savings. Today’s smart building software provides a robust solution to address these operational deficiencies. Energy management and information systems (EMIS) are saving up to 9% on average, with two-year paybacks. They are being incorporated into energy management processes, commissioning services, and utility programs. As effective as they are, two barriers prevent even deeper benefits; limited personnel to fix problems once they are identified, and the expense and time to manually implement changes in control systems. In partnership with the research community, the EMIS industry is developing new capabilities to overcome these barriers. Moving beyond siloed products for either fault detection and diagnostics, or optimal control, these new capabilities empower users to not only automatically identify faults, but also to push corrective action, and control improvements to their buildings. In this paper, several areas for enhancements are documented: ‘one-time’ correction of faults such as setpoints, schedules, and economizer lockouts; short-term active testing for automated proportional integral derivative (PID) loop tuning and functional testing; and continuous supervisory control for demand flexibility and year-round efficiency. Results are presented from a pair of partner implementations out of a dozen providers integrating these enhancements into their products, including field tests from across the country, and insights into operator acceptance and integration into operations and maintenance practices.

Casillas, Armando

Evaluating Variable-Impedance Magnetically-Insulated Transmission Lines as a Risk-Mitigation Measure for Next-Generation Pulsed Power

This project has produced the first detailed characterizations of power flow resulting from applying the “variable-impedance MITL” concept to real-life systems in Sandia’s pulsed power program (Z and next-generation pulsed power (NGPP)). We present simulation results and analyses for constant-impedance versions of both Z and NGPP and survey the operational viability of several variable-impedance re-designs in the parameter space of linear tapers. Circuit modeling (SCREAMER/Bertha) was used to pinpoint promising candidate designs, and EM-PIC (Empire) simulations were used to evaluate these candidates more rigorously. This approach was particularly successful in the Z regime which resulted in the identification of several viable variable-impedance MITL designs for each level. The approach was more challenged in the operating space NGPP occupies, producing data points that speak to a more restrictive design space due to anode plasma turn-on. In the end, we were able to converge on one viable variable-impedance design for the highest inductance line (level “F”) and one for the highest current line (level “A”). Altogether, the body of simulation evidence presented in this report suggest there does exist flexibility in operating space for magnetically-insulated transmission lines (MITLs) having variable geometric impedance to be a potential enabling technology for safely increasing current delivery (and potentially lowering stack voltage) in pulsed-power drivers by manipulating electron losses; however, operating points for a particular design must be carefully screened. Circuit and EM-PIC modeling provided consistent verdicts in safe operating regimes for operational viability, but additional physics such as anode plasma turn-on which is included in Empire but not in SCREAMER/Bertha was found to be a critical factor affecting power flow that lead to different assessments between the codes. It is not always the case that the occurrence of anode plasma caused a design to fail (some designs turned on anode plasma yet still delivered load currents meeting design targets); the details matter such as how early in the pulse anode surfaces break down (and how large a region). However, in every case that it did fail it was found that the feedback from anode plasma was the cause (i.e., turning off the anode plasma model in Empire restored agreement with the circuit model prediction). As circuit simulations represent an efficient and practical means of surveying design space compared to more computationally-expensive approaches such as EM-PIC, it could be prudent to invest in the research and development of models to include the effects of anode plasma such as ion emission in circuit codes. The variable-impedance MITL design is a new concept that enables controlled manipulation of the initial electron losses in the outer MITL and can be tested on Z today. We encourage follow-on work to explore further optimization (including alternative variable-impedance profiles, e.g., having constant dZ/dR), and to confirm the major findings presented in this report by fielding test hardware on actual Z shots.

24 POWER TRANSMISSION AND DISTRIBUTION

Wave energy converter buoy for Arctic observations

Ocean observation buoys are currently powered-constrained by battery storage capacity or available solar power. Power constraints limit the number of measurements that can be made and the lifetime of the buoys. Ocean surface wave energy could be used for power production, but wave energy converters are not yet commercially available for ocean observation buoys. Here we present the design and testing of a drifting wave energy converter buoy using a pendulum transmission system (PTS). The wave energy converter buoy was designed to operate in Arctic temperatures and wave conditions, but it could be used in areas with warmer temperatures and larger waves. Field tests measured a maximum power production of 5 watts in waves with a significant wave height of 0.42 meters and a ten minute average power production of 37 milliwatts. Power production increased with the energy period and significant wave height. The energy harvesting capabilities of the PTS showed the utility of adding a wave energy conversion device to a drifting ocean observation buoy.

Arctic observations

Using Artificial Soiling to Rank Anti-Soiling Coatings for Arid Climates

A simple method to evaluate (e.g., screen and rank) the performance of coatings that are fully or partially anti-soiling (AS) is lacking within the PV industry. Artificial soiling may be used as a rapid and economical assessment approach, offering an efficient alternative to time-intensive, site-specific field testing. In this study, we present an artificial soiling method to replicate the anti-soiling performance rankings of two groups of coated glass samples supplied by two manufacturers (group C with CA, CP, and CS coatings; group A with AC coating). These are compared to field aging in two climates: semi-arid Lemoore, California over 4 months, and the hot desert in Mesa, Arizona over 7 months. Both field and indoor performance ranking utilize the transmittance ratio, defined as the optical transmittance between a coated sample and an uncoated reference in each group, as an evaluation metric to assess the effectiveness of the artificial soiling approach in replicating field soiling. It is critical to mimic the dominant field meteorological conditions associated with soiling-prone days and vulnerable times of day during the soiling season. Our results reveal that the use of artificial soiling for field performance ranking among coatings strongly depends on the soil type (composition and particle distribution), dust surface density, and prevalent environmental factors (wetting saturation by humidity, dew condensation extent, and prior weathering history of the coating). The similar rank order relative to the field suggests that the artificial soiling approach presented may be used for down-selecting anti-soiling coatings prior to prolonged field validation.

14 SOLAR ENERGY

Simultaneous Overexpression of FERULOYL‐CoA 6′‐HYDROXYLASE 1 and COUMARIN SYNTHASE Leads to Coumarin‐Enriched Lignin and Improved Saccharification in Greenhouse‐ and Field‐Grown Poplar

ABSTRACT The urgent need for renewable resources has increased the interest in woody biomass to manufacture bio‐based products. However, lignin recalcitrance limits the enzymatic conversion of wood into fermentable sugars, posing a major challenge for biomass deconstruction. To address this problem, we aimed at incorporating the coumarin scopoletin into the lignin polymer of poplar ( Populus tremula × P . alba ) by expressing FERULOYL‐CoA 6′‐HYDROXYLASE 1 ( F6′H1 ) and COUMARIN SYNTHASE ( COSY ) in lignifying cells. Three constructs were evaluated: two bicistronic constructs, SCOP1 ( COSY followed by F6′H1 ) and SCOP2 ( F6′H1 followed by COSY ), and one monocistronic, SCOP3 (only F6′H1 ). SCOP1 poplars produced most free scopoletin without altering overall lignin, cellulose or hemicellulose content. SCOP2 poplars were overall less efficient in scopoletin production and most of these lines showed a severe biomass yield penalty, whereas SCOP3 caused plant lethality. NMR and metabolic analyses confirmed that scopoletin cross‐coupled with G and S monomers during lignification in SCOP1 lines. In addition to scopoletin, the detection of benzodioxane structures revealed the incorporation of dihydroxycoumarins. Overall coumarin incorporation in lignin amounted up to 2.3%. After alkaline pretreatment, wood from greenhouse‐grown SCOP1 poplars released up to 29% more glucose compared to the wild type upon limited saccharification. Field‐testing of three SCOP1 lines showed a 6 to 11% increase in saccharification efficiency, with the line containing the lowest scopoletin levels maintaining normal growth. These results demonstrate that engineering lignin composition in poplar can improve saccharification, and emphasize the importance of construct design, translational research and field validation.

alternative lignin monomers