Search NASASearch

SEARCH · Search NASA

Results for “Grid”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

96 records · Page 4

Security Constrained Economic Optimization of Photovoltaic and Other Distributed Assets

The rapid growth of distributed energy resources (DERs), especially photovoltaic (PV) systems, has introduced new complexities in maintaining grid reliability, stability, and cost-effective operation. This project addresses these challenges by developing and demonstrating a scalable GridOS Distributed Energy Resource Management System (DERMS) that enables secure, real-time optimization and control of DERs at the distribution feeder level.

14 SOLAR ENERGY

Application of Ibuprofen Sodium Dihydrate for Thermochemical Energy Storage

Thermochemical energy storage (TCES) offers a transformative approach to address grid instability by harnessing reversible chemical reactions for efficient heat storage and release. Here, we introduce pharmaceutical organic salt hydrates as a class of materials with exceptional performance for low-grade waste heat recovery. We demonstrate ibuprofen sodium dihydrate (ISD) as an example organic hydrate exhibiting a dehydration temperature range of 60-110 °C and a remarkable dehydration enthalpy of up to 59.5 kJ/mol of water, ideally suited for capturing industrial and residential waste heat. Using rigorous multimodal characterization, including thermogravimetric analysis, differential scanning calorimetry, in-situ FTIR, in-situ PXRD, and NMR, we demonstrate ISD's superior thermal, chemical, and structural stability over 150 hydration-dehydration cycles, achieving an unprecedented cycling efficiency of ~99.9%. Compared to conventional inorganic salt hydrates like strontium chloride hexahydrate and calcium oxalate monohydrate, ISD showcases enhanced durability without deliquescence or pulverization, even under high-humidity conditions. In-situ analyses confirm the transition from ISD to ibuprofen sodium anhydrous (ISA) proceeds with structural reorganization, thereby combining the dehydration mechanism with phase transitions, resulting in higher energy storage capacity. Microstructural analyses reveal that repeated water intercalation and structural transitions aid in creating significant porosity that enhances water transport kinetics, further improving the hydration/dehydration performance. By combining the phase change and chemical dehydration mechanisms, ISD paves the way for designing a new class of organic salt hydrates, offering tunable properties to meet diverse thermal energy storage demands and supporting sustainable grid resilience.

Thangaraj, Kavin C.

High-resolution modeling of indoor radon exposure with uncertainty quantification in Utah

Indoor radon accounts for 37% of population-level exposure to ionizing radiation in the United States. However, radon metrics are typically reported at coarse spatial scales, potentially obscuring meaningful local variation. We developed a high-resolution modeling framework to estimate indoor radon concentrations across Utah while explicitly quantifying predictive uncertainty. A total of 19,497 residential radon measurements collected between 2006 and 2017 were combined with environmental and housing characteristics and analyzed using a geospatial neural network that accommodates spatial dependence and nonlinear associations. Predictions were generated on a uniform hexagonal grid at 0.73 km2 resolution (H3 level 8). Out-of-sample predictions aggregated to the H3 level 8 grid showed good agreement with observed concentrations (Pearson r=0.64), while household-level predictions exhibited more moderate agreement (r=0.45). The model produced well-calibrated uncertainty estimates, with 24.1% of held-out observations exceeding the predicted 75th-percentile threshold. Maps of predicted radon concentrations and the probability of exceeding the U.S. EPA action level of 148 Bq/m3 (4 pCi/L) revealed substantial fine-scale spatial heterogeneity that was not apparent in conventional coarse-resolution summaries, with greater local variability observed in densely monitored urban counties than in sparsely sampled regions. High-resolution radon models that explicitly quantify uncertainty provide a useful framework for characterizing the spatial distribution of indoor radon and identifying areas of elevated exceedance risk. These findings highlight the value of fine-scale monitoring data and uncertainty-aware modeling approaches for radon exposure assessment, environmental risk characterization, and radon-related health research.

Wu, Yunhan [ORNL] (ORCID:0000000178842994)

Kauhale 'O Kipapa: Kahikinui Community Cultural, Educational, and Resilience Center Preliminary Design Technical Assistance Summary Report

The Kahikinui Homestead Community in Maui faces energy resilience challenges due to its remote, off-grid location. This report summarizes preliminary technical assistance to design a microgrid for six modular homes using solar PV, wind, and battery storage. Findings show hybrid PV and battery systems, supplemented by small wind turbines, offer cost-effective, resilient solutions. This work supports enhanced energy independence and disaster preparedness for the community.

Quiroz, Jimmy Edward [Sandia National Laboratories

Halau Uma: Kahikinui Community Cultural, Educational, and Resilience Center Preliminary Design Technical Assistance Summary Report

The Kahikinui Homestead Community in Maui faces energy resilience challenges due to its remote, off-grid location. This report summarizes preliminary technical assistance to design a microgrid for six modular homes using solar PV, wind, and battery storage. Results indicate that a hybrid PV and battery system, supplemented by small wind turbines, offers a cost-effective, resilient solution supporting energy independence and disaster preparedness.

Quiroz, Jimmy Edward [Sandia National Laboratories

Roadmap and Benchmarking: Privacy in Federated Load Forecasting

Data-driven techniques for energy demand forecasting continue to emerge with promising impacts on distribution grid planning. However, the development of robust and generalizable machine learning models requires that representative high quality training data are available. Distributed energy resources have begun to embed intelligence, gathering large amounts of data on customer demand, behavior, and household devices that are connected to the grid. Though utilities aggregate meter-level demand data for load shaping, demand response, outage management, reliability planning, and billing applications, there lies an inherent privacy concern in sharing consumption data that may identify individual consumer behavioral patterns. Hence, while sharing the data is crucial, the private sensitive customer data must be safeguarded from being exposed or manipulated. In this study, we propose a roadmap for implementing a based privacy preserving framework to support the advancement of data-driven analytics in data-sensitive distributed energy resources environments. The roadmap incorporates federated learning–a distributed training framework, differential privacy–a statistical framework that provides guarantees to safeguard the leakage of sensitive data, secure multiparty computation and homomorphic encryption– techniques for encrypting model gradients and applying secure aggregation on the server. Moreover, we perform baseline experiments on the federated short-term load forecasting (STLF) task using open-source residential load profile datasets, offering insights into the challenges of integrating differential privacy into federated learning.

Abebe, Waqwoya [Oak Ridge National Laboratory (ORN

A GPU-based Approach for Turbomachinery Application

Accurate modeling of coolant airflows, which form protective films over turbine blades, is essential for designing fuel-efficient and environmentally sustainable gas turbine engines. Excessive coolant reduces thermal efficiency, while insufficient coolant leads to blade overheating and causes damage. Therefore, precise prediction of flow field interactions with cooling air is critical for optimizing turbine performance. This study numerically investigates the cooling effectiveness of purge and film cooling flows within a high-pressure turbine (HPT) rotor using Large Eddy Simulation (LES). The study utilizes NASA Glenn Research Center’s Glenn-HT solver. The simulation models ethe conditions of the Penn State University START rotating rig. A high-fidelity structured mesh comprising up to 800 million cells is employed to resolve high-Reynolds number flow (Re ≈ 350,000) and to capture intricate secondary flow structures, including tip leakage and purge-induced vortices. Film cooling effectiveness computations are highly sensitive to boundary conditions at the cooling holes and to grid resolution. Even with well-resolved grids and included plena, strong mixing challenges traditional eddy viscosity models. To address this, a simplified configuration is simulated: a truncated row of shaped holes on the suction side near the leading edge and a row on the pressure side, both fed from internal plena while the purge slot and tip clearance are also modeled. Two isothermal LES cases are conducted at two distinct wall temperatures, which yield the adiabatic wall temperature and the heat transfer coefficient. The definition and means of computation of the effectiveness is discussed in this paper. The simulations reveal detailed three-dimensional unsteady flow features, including coherent vortical structures and secondary flows originating from the purge cavity. Film cooling effectiveness and Nusselt number distributions are presented for both the blade surface and tip, highlighting regions of elevated heat transfer and complex thermal behavior. These findings underscore the importance of high-resolution LES and realistic boundary conditions in capturing the dynamics of purge and film cooling, offering valuable insights for improving turbine blade design and thermal management strategies.

Gas Turbine

LES-Based Analysis of Film Cooling in a High-Pressure Turbine Rotor Including Effects of Purge and Tip Flow

Accurate modeling of coolant airflows, which form protective films over turbine blades, is essential for designing fuel-efficient and environmentally sustainable gas turbine engines. Excessive coolant reduces thermal efficiency, while insufficient coolant leads to blade overheating and causes damage. Therefore, precise prediction of flow field interactions with cooling air is critical for optimizing turbine performance. This study numerically investigates the cooling effectiveness of purge and film cooling flows within a high-pressure turbine (HPT) rotor using Large Eddy Simulation (LES). The study utilizes NASA Glenn Research Center’s Glenn-HT solver. The simulation models ethe conditions of the Penn State University START rotating rig. A high-fidelity structured mesh comprising up to 800 million cells is employed to resolve high-Reynolds number flow (Re ≈ 350,000) and to capture intricate secondary flow structures, including tip leakage and purge-induced vortices. Film cooling effectiveness computations are highly sensitive to boundary conditions at the cooling holes and to grid resolution. Even with well-resolved grids and included plena, strong mixing challenges traditional eddy viscosity models. To address this, a simplified configuration is simulated: a truncated row of shaped holes on the suction side near the leading edge and a row on the pressure side, both fed from internal plena while the purge slot and tip clearance are also modeled. Two isothermal LES cases are conducted at two distinct wall temperatures, which yield the adiabatic wall temperature and the heat transfer coefficient. The definition and means of computation of the effectiveness is discussed in this paper. The simulations reveal detailed three-dimensional unsteady flow features, including coherent vortical structures and secondary flows originating from the purge cavity. Film cooling effectiveness and Nusselt number distributions are presented for both the blade surface and tip, highlighting regions of elevated heat transfer and complex thermal behavior. These findings underscore the importance of high-resolution LES and realistic boundary conditions in capturing the dynamics of purge and film cooling, offering valuable insights for improving turbine blade design and thermal management strategies.

Secondary Flows

Technoeconomic Studies for the Rorex Creek Pumped Storage Hydro Project: An Evaluation of New Pumped Storage Hydro in the Tennessee Valley Authority System

This report evaluates the economic viability of the proposed 1,200 MW, 23,365 MWh Rorex Creek Pumped Storage Hydro (PSH) plant that would be located near Pisgah, Alabama. In addressing this question, this study has developed processes, models and data that better value PSH from a utility perspective, more specifically a vertically integrated utility, enabling optimal PSH design and deployment. This study is designed to enhance TVA’s toolset in making PSH investment decisions and contribute to the design of a more cost-effective, stable future grid. These techniques can then be applied to a broader range of assets and utilities.

Cohen, Stuart

The Benard Problem: A Comparison of Finite Difference and Spectral Collocation Eigen Value Solutions

The application of spectral methods, using a Chebyshev collocation scheme, to solve hydrodynamic stability problems is demonstrated on the Benard problem. Implementation of the Chebyshev collocation formulation is described. The performance of the spectral scheme is compared with that of a 2 nd order finite difference scheme. An exact solution to the Marangoni-Benard problem is used to evaluate the performance of both schemes. The error of the spectral scheme is at least seven orders of magnitude smaller than finite difference error for a grid resolution of N = 15 (number of points used). The performance of the spectral formulation far exceeded the performance of the finite difference formulation for this problem. The spectral scheme required only slightly more effort to set up than the 2 nd order finite difference scheme. This suggests that the spectral scheme may actually be faster to implement than higher order finite difference schemes.

J Raymond Lee Skarda

WRF-Comfort: simulating microscale variability in outdoor heat stress at the city scale with a mesoscale model

Abstract. Urban overheating and its ongoing exacerbation due to global warming and urban development lead to increased exposure to urban heat and increased thermal discomfort and heat stress. To quantify thermal stress, specific indices have been proposed that depend on air temperature, mean radiant temperature (MRT), wind speed, and relative humidity. While temperature and humidity vary on scales of hundreds of meters, MRT and wind speed are strongly affected by individual buildings and trees and vary on the meter scale. Therefore, most numerical thermal comfort studies apply microscale models to limited spatial domains (commonly representing urban neighborhoods with building blocks) with resolutions on the order of 1 m and a few hours of simulation. This prevents the analysis of the impact of city-scale adaptation and/or mitigation strategies on thermal stress and comfort. To solve this problem, we develop a methodology to estimate thermal stress indicators and their subgrid variability in mesoscale models – here applied to the multilayer urban canopy parameterization BEP-BEM within the Weather Research and Forecasting (WRF) model. The new scheme (consisting of three main steps) can readily assess intra-neighborhood-scale heat stress distributions across whole cities and for timescales of minutes to years. The first key component of the approach is the estimation of MRT in several locations within streets for different street orientations. Second, mean wind speed and its subgrid variability are downscaled as a function of the local urban morphology based on relations derived from a set of microscale LES and RANS simulations across a wide range of realistic and idealized urban morphologies. Lastly, we compute the distributions of two thermal stress indices for each grid square, combining all the subgrid values of MRT, wind speed, air temperature, and absolute humidity. From these distributions, we quantify the high and low tails of the heat stress distribution in each grid square across the city, representing the thermal diversity experienced in street canyons. In this contribution, we present the core methodology as well as simulation results for Madrid (Spain), which illustrate strong differences between heat stress indices and common heat metrics like air or surface temperature both across the city and over the diurnal cycle.

Geology

Analysis of Developing Laminar Flows in Circular Pipes Using a Higher-Order Finite-Difference Technique

A higher-order finite-difference technique is developed to calculate the developing-flow field of steady incompressible laminar flows in the entrance regions of circular pipes. Navier-Stokes equations governing the motion of such a flow field are solved by using this new finite-difference scheme. This new technique can increase the accuracy of the finite-difference approximation, while also providing the option of using unevenly spaced clustered nodes for computation such that relatively fine grids can be adopted for regions with large velocity gradients. The velocity profile at the entrance of the pipe is assumed to be uniform for the computation. The velocity distribution and the surface pressure drop of the developing flow then are calculated and compared to existing experimental measurements reported in the literature. Computational results obtained are found to be in good agreement with existing experimental correlations and therefore, the reliability of the new technique has been successfully tested.

Herbert J Gladden

Revolutionizing thermal Management in Next-Generation AI data centers: Challenges and breakthrough innovations

Data centers (DCs) serve as critical infrastructure for powering the growth and evolution of AI. Next-generation AI DCs present unique challenges in thermal management driven by unprecedented computational demands. This paper provides a comprehensive summary of key stakeholder perspectives on technology gaps, infrastructure requirements, test bed needs, emerging opportunities, and preliminary solutions related to thermal management for AI DCs. It establishes six strategic pillars of thermal management for next generation AI DC: reliability, deployability, efficiency, resilience, measurability, and valorization. The discussion spans a range of critical topics, including advanced cooling technologies, thermal strategies for emerging modular and edge DCs, system-level optimization and control frameworks, infrastructure planning and grid integration designs, benchmarking approaches, and pathways for waste heat recovery and reuse. The proposed research, development, and demonstration efforts are aimed at accelerating the deployment of AI DCs while ensuring energy efficiency, reliability, safety, and regulatory compliance.

Wang, Pengtao [ORNL] (ORCID:0000000214713429)

A Sensitivity-driven Wide Area Protection (SWAP) Coordination Tool for High Penetration of Inverter-based Resources (IBR)

Traditionally, power system generation sources have been composed of synchronous generators, of which the fault current behavior is understood with minimal differences between generation size and types due to the physics of their construction. Present protection schemes and modeling methods are based upon these understood characteristics. Most renewable generation is composed of inverter-based resources (IBR), in which fault current is determined by switching control software and hardware limitations, each of which can vary between manufacturers and even between models of the same manufacturer. The resulting fault current is low in magnitude, low in negative-sequence current, unpredictable phase angles, and is a challenge to model. These characteristics also result in a challenge to traditional protection schemes and fault simulation software. To address several of these concerns, the project has the following goals: 1. Improve IBR models: Improve IBR models used in short circuit (SC) programs to accurately capture the response of IBRs at the bulk power system (BPS) level for fault and protection studies. 2. Develop automation tool: Develop an automation tool that allows engineers to identify protection coordination and sensitivity issues by performing SC and protection coordination studies in a high IBR-penetrated grid by applying variations to the IBR models, faults, contingencies, etc. 3. Develop schemes: Develop new protection mitigation solution schemes that complement the existing protection systems to ensure safe operation of the BPS with higher IBR penetration levels. The project team did not achieve this final goal, as the Department of Energy (DOE) stopped the project early due to changes in DOE funding priorities. The termination notice came at the beginning of the final project phase, while the team was identifying and beginning to investigate protection issues. It should be noted that the team discussed a 100% penetration scenario. However, this scenario would require the use of grid-forming IBR models that are not presently available. Since developing these models requires additional effort, the 100% penetration scenario was not pursued during this project. In the future, developing the methodology and models for the 100% scenario could benefit the industry.

14 SOLAR ENERGY

CAE for Thermal Management of Aerospace Electronic Boards Using the BETAsoft Program

Aerospace electronic boards require special attention to thermal management due to constraints such as their need to be light, small, and maintain high power densities. Also, cooling is mainly through conductive and radiative modes with minor or negligible convective cooling. Due to these particular requirements, thermal design has become an integrated part of the electronic design process in order to avoid expensive repeat prototyping and to ensure high reliability. To achieve high speed simulations, the BETAsoft code uses semi-empirical formulations and an advanced finite difference scheme that incorporates local adaptive grids. Detailed conduction, convection and radiation heat transfer is considered. Various benchmark verifications of the software simulation compared to infrared images typically prove to be within 10% of each other. The thermal analysis of a sample avionic card in a natural convection environment is shown. Then, the individual effects of attaching metal screws to the casing, increasing radiative emissivities of the casing, increasing the conductance of the wedge lock, adding an aluminum core to the board, adding metal strips in board layers, inserting conduction pads under components, and adding heat sinks to components are demonstrated.

Kimberly Bobish

Extensional Flow Convecting a Reactant Undergoing a First Order Homogeneous Reaction and Diffusional Mass Transfer From a Sphere at Low to Intermediate Peclet and Damkohler Numbers

Forced convective diffusion-reaction is considered for viscous axisymmetric extensional convecting velocity in the neighborhood of a sphere. For Peclet numbers in the range 0.1 ≤ Pe ≤ 500 and for Damkohler numbers increasing with increasing Pe but in the overall range 0.02 ≤ Da ≤ 10, average and local Sherwood numbers have been computed. By introducing the eigenfunction expansion c(r,Θ) = Σ c n (r)P n (cosΘ) into the forced convective diffusion equation for the concentration of a chemical species undergoing a first order homogeneous reaction and by using properties of the Legendre functions P n (cosΘ), the variable coefficient PDE can be reduced to a system of N+1 second order ODEs for the radial functions C n (r), n=0,1,2, ... ,N. The adaptive grid algorithm of Pereyra and Lentini can be used to solve the corresponding 2(N+ 1) first order differential equations as a two-point boundary value problem on 1 ≤ r ≤ r •• . Convergence of the expansion for a specific value of N can thus be established and provides "spectral" behavior as well as the full concentration field c(r,Θ).

N Y Shah

Exceedance Probabilities and Recurrence Intervals for Extended Power Outages in the United States

This report provides estimates of recurrence intervals and conditional exceedance probabilities for major power outages by U.S. region between 2015 and 2021. Additionally, we provide estimates for grid management, particularly outages caused by California’s public safety power shutoffs (PSPS), and for natural outages caused by major hurricanes. Outage recurrence intervals are the average number of years between outage events, and conditional exceedance probabilities are the likelihoods that a customer who experiences a major power outage will experience an outage exceeding a given duration. Major outage events are those that affect 10,000 or more customers, as defined by the U.S. Department of Energy’s (DOE’s) Electric Emergency Incident and Disturbance Report, called OE-417 (DOE 2020). These results can be applied to determine the likelihood of experiencing long-duration outages, which can be integrated into cost-benefit analyses of resilience solutions and broader energy resilience studies.

Ericson, Sean [National Renewable Energy Laborator

CFD-Assisted Nodal Modeling of Sloshing in a Cryogenic Propellant Tank

During autogenous pressurization, tank sloshing causes a significant increase in pressurant consumption to maintain constant ullage pressure during draining of the tank. This increase in pressurant consumption is caused by a significant increase in condensation at the liquid-vapor interface. Sloshing strongly affects the liquid side heat transfer coefficient and thereby the condensation rate. Traditionally, sloshing is modeled by CFD code using the VOF (Volume of Fluid) method to track the liquid vapor interface during sloshing. CFD calculations require a very fine grid to accurately compute the heat and mass transfer at the interface. Therefore, computations are time consuming and prohibit performing many parametric studies often needed during the design of a new system. This paper describes an alternative approach by developing a CFD-assisted nodal model to predict system parameters more economically with reasonable accuracy. In this approach, a multi-node model of tank pressurization was developed using GFSSP. A multi-node model was needed to account for stratification. The model computes heat and mass transfer at the interface to calculate the condensation rate. The liquid side heat transfer is computed using the parameters of sloshing dynamics such as frequency, wave amplitude, and interface area. The parameters of sloshing dynamics are computed by the CFD code LOCI-Stream. The model predictions were compared with test data for several cases.

Cryogenic Tank Sloshing