Search NASA⌕ Search

SEARCH · Search NASA

Results for “High gradient”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

An update on the study of high-gradient elliptical SRF cavities at 805 MHz for proton and other applications

An update on the study of 805 MHz elliptical SRF cavities that have been optimized for high gradient will be presented. An optimized cell shape, which is still appropriate for easy high pressure water rinsing, has been designed with the ratios of peak magnetic and electric fields to accelerating gradient being 3.75 mT/(MV/m) and 1.82, respectively. A total of 3 single-cell cavities have been fabricated. Two of the 3 cavities have been tested so far. The second cavity achieved an E{sub acc} of {approx}50 MV/m at Q{sub 0} of 1.4 x 10{sup 10}. This result demonstrates that 805 MHz cavities can, in principle, achieve as high as, or could even be better than, 1.3 GHz high-gradient cavities.

43 PARTICLE ACCELERATORS↗

Generation of high gradient wakefields in dielectric loaded structures.

Dielectric loaded wakefield structures have potential to be used as high gradient accelerator components. Using the high current drive beam at the Argonne Wakefield Accelerator Facility, we employed cylindrical dielectric loaded wakefield structures to generate accelerating fields of up to 100 MV/m. Short electron bunches (13 ps FWHM) of up to 86 nC are used to drive these fields, either as single bunches or as bunch trains. These tested standing-wave structures have a field probe near the outer edge of the dielectric to sample the RF fields generated by the electron bunches. Monitoring of these high intensity RF fields serves to verify the absence of electric breakdown. Similar cylindrical dielectric loaded structures are used as power extractors, that is, traveling wave structures from which the RF power generated by the drive beam is efficiently coupled out.

36 MATERIALS SCIENCE↗

Fabrication Technologies of the High Gradient Accelerator Structures at 100MV/M Range

A CERN-SLAC-KEK collaboration on high gradient X-band structure research has been established in order to demonstrate the feasibility of the CLIC baseline design for the main linac stably operating at more than 100 MV/m loaded accelerating gradient. Several prototype CLIC structures were successfully fabricated and high power tested. They operated at 105 MV/m with a breakdown rate that meets the CLIC linear collider specifications of < 5 x 10{sup -7}/pulse/m. This paper summarizes the fabrication technologies including the mechanical design, precision machining, chemical cleaning, diffusion bonding as well as vacuum baking and all related assembly technologies. Also, the tolerances control, tuning and RF characterization will be discussed.

43 PARTICLE ACCELERATORS↗

Long lifetime of bialkali photocathodes operating in high gradient superconducting radio frequency gun

Abstract High brightness, high charge electron beams are critical for a number of advanced accelerator applications. The initial emittance of the electron beam, which is determined by the mean transverse energy (MTE) and laser spot size, is one of the most important parameters determining the beam quality. The bialkali photocathodes illuminated by a visible laser have the advantages of high quantum efficiency (QE) and low MTE. Furthermore, Superconducting Radio Frequency (SRF) guns can operate in the continuous wave (CW) mode at high accelerating gradients, e.g. with significant reduction of the laser spot size at the photocathode. Combining the bialkali photocathode with the SRF gun enables generation of high charge, high brightness, and possibly high average current electron beams. However, integrating the high QE semiconductor photocathode into the SRF guns has been challenging. In this article, we report on the development of bialkali photocathodes for successful operation in the SRF gun with months-long lifetime while delivering CW beams with nano-coulomb charge per bunch. This achievement opens a new era for high charge, high brightness CW electron beams.

43 PARTICLE ACCELERATORS↗

Analysis Code for High Gradient Dielectric Insulator Surface Breakdown

High voltage (HV) insulators are critical components in high-energy, accelerator and pulsed power systems that drive diverse applications in the national security, nuclear weapons science, defense and industrial arenas. In these systems, the insulator may separate vacuum/non-vacuum regions or conductors with high electrical field gradients. These insulators will often fail at electric fields over an order of magnitude lower than their intrinsic dielectric strength due to flashover at the dielectric interface. Decades of studies have produced a wealth of information on fundamental processes and mechanisms important for flashover initiation, but only for relatively simple insulator configurations in controlled environments. Accelerator and pulsed power system designers are faced with applying the fundamental knowledge to complex, operational devices with escalating HV requirements. Designers are forced to rely on “best practices” and expensive prototype testing, providing boundaries for successful operation. However, the safety margin is difficult to estimate, and system design must be very conservative for situations where testing is not practicable, or replacement of failed parts is disruptive or expensive. The Phase I program demonstrated the feasibility of developing an advanced code for modeling insulator breakdown. Such a code would be of great interest for a number of applications, including high energy physics, microwave source development, fusion sciences, and other research and industrial applications using high voltage devices.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Progress of ILC High Gradient SRF Cavity R&D at Jefferson Lab

Latest progress of ILC high gradient SRF cavity R&D at Jefferson Lab will be presented. 9 out of 10 real 9-cell cavities reached an accelerating gradient of more than 38 MV/m at a unloaded quality factor of more than 8 {center_dot} 109. New understandings of quench limitation in 9-cell cavities are obtained through instrumented studies of cavities at cryogenic temperatures. Our data have shown that present limit reached in 9-cell cavities is predominantly due to localized defects, suggesting that the fundamental material limit of niobium is not yet reached in 9-cell cavities and further gradient improvement is still possible. Some examples of quench-causing defects will be given. Possible solutions to pushing toward the fundamental limit will be described.

43 PARTICLE ACCELERATORS↗

Development of High-Gradient Dielectric Laser-Driven Particle Accelerator Structures

The thrust of Stanford's program is to conduct research on high-gradient dielectric accelerator structures driven with high repetition-rate, tabletop infrared lasers. The close collaboration between Stanford and SLAC (Stanford Linear Accelerator Center) is critical to the success of this project, because it provides a unique environment where prototype dielectric accelerator structures can be rapidly fabricated and tested with a relativistic electron beam.

43 PARTICLE ACCELERATORS↗

Dielectric-Lined High-Gradient Accelerator Structure (Final Report)

Rectangular particle accelerator structures with internal planar dielectric elements have been studied, with a view towards devising structures with lower surface fields for a given accelerating field, as compared with structures without dielectrics. Success with this concept is expected to allow operation at higher accelerating gradients than otherwise on account of reduced breakdown probabilities. The project involves studies of RF breakdown on amorphous dielectrics in test cavities that could enable high-gradient structures to be built for a future multi-TeV collider. The aim is to determine what the limits are for RF fields at the surfaces of selected dielectrics, and the resulting acceleration gradient that could be achieved in a working structure. The dielectric of principal interest in this study is artificial CVD diamond, on account of its advertised high breakdown field (~2 GV/m for dc), low loss tangent, and high thermal conductivity. Experimental studies at mm-wavelengths on materials and structures for achieving high acceleration gradient were based on the availability of the 34.3 GHz third-harmonic magnicon amplifier developed by Omega-P, and installed at the Yale University Beam Physics Laboratory. Peak power from the magnicon was measured to be about 20 MW in 0.5 μs pulses, with a gain of 54 dB. Experiments for studying RF high-field effects on CVD diamond samples failed to show any evidence after more than 10 5 RF pulses of RF breakdown up to a tangential surface field strength of 153 MV/m; studies at higher fields were not possible due to a degradation in magnicon performance. A rebuild of the tube is underway at this writing. Computed performance for a dielectric-loaded rectangular accelerator structure (DLA) shows highly competitive properties, as compared with an existing all-metal structure. For example, comparisons were made of a DLA structure having two planar CVD diamond elements with a all-metal CERN structure HDS operating at 30 GHz. It was shown that the ratio of maximum surface electric field to accelerating field at the metal wall is only 0.35-0.4 for DLA, much smaller than the value 2.2 for HDS; and the ratio of surface magnetic field to accelerating field is 3.0 mA/V for DLA, compared with 3.45 mA/V for HDS. These values bode well for DLA in helping to avoid breakdown and to reducing pulsed surface heating and fatigue. The shunt impedance is found to be 160-175 MΩ/m for DLA, as compared to 99 MΩ/m for HDS. Conclusions are reached from this project that CVD diamond appears promising as a dielectric with a high threshold for RF breakdown, and that rectangular accelerator structures can be devised using planar CVD diamond elements that could be operated at higher acceleration gradients with low probability of RF breakdown, as compared with corresponding all-metallic structures.

36 MATERIALS SCIENCE↗

High-gradient SRF R&D for ILC at Jefferson Lab

Jefferson Lab plays an active role in high-gradient SRF R&D in the frame work of the internationally coordinated ILC S0 program. The S0 aim is to push the yield at 35 MV/m in 9-cell cavities. So far, twelve cavities have been electropolishing (EP) processed and RF tested by using the state-of-the-art recipes at JLab, in close collaboration with FNAL and KEK. Seven of them reached a best gradient of over 31.5 MV/m. Understanding gradient limiting mechanisms in real 9-cell cavities is an important component of our studies. Thermometry and high-resolution optical inspection are used to locate and understand the source of gradient limits. Experimenting with selective cavities is still a necessary method for process optimization. One example is the first demonstration of 35 MV/m without detectable Bremsstrahlung X-ray after a light EP is applied to a previously heavy BCP etched 7-cell cavity. Some new understanding has been gained with regard to quench behaviors, field emission behaviors as well as optimized processing. Progress has been made as a result, exemplified by the recent achievement of ? 35 MV/m in two cavities, each after the first light EP. Several exploratory studies are under way at JLab, aiming to covert the new understandings into further improved cavity gradient results.

Geng, Rongli↗

High-gradient SRF R&D for ILC at Jefferson Lab

Jefferson Lab plays an active role in high-gradient SRF R&D in the frame work of the internationally coordinated ILC S0 program. The S0 aim is to push the yield at 35 MV/m in 9-cell cavities. So far, twelve cavities have been electropolishing (EP) processed and RF tested by using the state-of-the-art recipes at JLab, in close collaboration with FNAL and KEK. Seven of them reached a best gradient of over 31.5 MV/m. Understanding gradient limiting mechanisms in real 9-cell cavities is an important component of our studies. Thermometry and high-resolution optical inspection are used to locate and understand the source of gradient limits. Experimenting with selective cavities is still a necessary method for process optimization. One example is the first demonstration of 35 MV/m without detectable Bremsstrahlung X-ray after a light EP is applied to a previously heavy BCP etched 7-cell cavity. Some new understanding has been gained with regard to quench behaviors, field emission behaviors as

43 PARTICLE ACCELERATORS↗

New results of development on high efficiency high gradient superconducting rf cavities

We report on the latest results of development on high-efficiency high-gradient superconducting radio frequency (SRF) cavities. Several 1-cell cavities made of large-grain niobium (Nb) were built, processed and tested. Two of these cavities are of the Low Surface Field (LSF) shape. Series of tests were carried out following controlled thermal cycling. Experiments toward zero-field cooling were carried out. The best experimentally achieved results are E acc = 41 MV/m at Q 0 = 6.5×10 10 at 1.4 K by a 1-cell 1.3 GHz large-grain Nb TTF shape cavity and E acc = 49 MV/m at Q 0 = 1.5×10 10 at 1.8 K by a 1-cell 1.5 GHz large-grain Nb CEBAF upgrade low-loss shape cavity.

43 PARTICLE ACCELERATORS↗

Ion Bombardment of Microprotrusions in High Gradient Accelerating Structures

This paper starts from a brief overview of theoretical studies of high-gradient accelerating structures at the University of Maryland. The rest of the paper is devoted to the analysis of ion bombardment of small protrusions in such structures. First, this problem is studied analytically. Then, some results of particle-in-cell simulations performed with the use of code WARP are presented and discussed.

43 PARTICLE ACCELERATORS↗

Manufacturing Full-Scale High Gradient Copper Accelerators: Electron Beam Welding and Allied Processes

This DOE ARDAP-funded study examines the technical and business feasibility of manufacturing high-gradient normal conducting RF (NCRF) copper accelerating structures using electron beam welding (EBW) instead of conventional high-temperature brazing. The core motivation is material performance: brazing softens copper significantly, while hard copper alloys have demonstrated ~75% higher operational gradients in SLAC tests, making cold-joining techniques highly attractive. EBW, applied to split-cell (half or quadrant) structure designs, preserves copper hardness away from the weld joint and simplifies machining — but industrial process optimization remains immature and a substantial learning curve is expected. The business case was modeled for two scenarios: a greenfield EBW linac company (> $10M upfront costs, viable above ~30 units/year) and an EBW division added to an existing accelerator firm to reduce risk and upfront costs, at the expense of being less optimal structure for the higher volume production. The study concludes that without a significant increase in demand, private investment alone cannot sustain this capability, and recommends federal support through R&D grants, procurement incentives, and CAPEX cost-sharing to incubate domestic EBW-NCRF manufacturing — with the existing-company model.

43 PARTICLE ACCELERATORS↗

Theory of factors limiting high gradient operation of warm accelerating structures

This report consists of two parts. In the first part we describe a study of the heating of microprotrusions on surfaces of accelerating structures. This ;process is believed to lead to breakdown in these structures. Our study revealed that for current accelerator parameters melting should not occur due to space charge limitations of the current emitted by a protrusion. The second part describes a novel concept to develop THz range sources based on harmonic cyclotron masers for driving future colliders. This work was stimulated by a recent request of SLAC to develop high power, high-efficiency sources of sub-THz radiation for future high-gradient accelerators.

43 PARTICLE ACCELERATORS↗

Measurement of internal dark current in a 17 GHz, high gradient accelerator structure

We report the measurement of the internal dark current in a 17 GHz, high gradient accelerator cavity and its comparison with theory. The cavities were fabricated from copper and had a sidewall that was either uncoated or coated with diamondlike carbon or TiN. The dark current was monitored by a downstream detector and by detectors behind two small slits made in the cavity sidewall. With an increasing gradient, the downstream current increased monotonically, as expected for field emission. The variation of the internal, side dark current was not monotonic but showed the onset of peaks at gradients near 45 and 65 MV / m . These were identified as the N = 2 and N = 1 single point multipactor resonances. The total internal dark current was estimated at ~ 15 – 30 A . The magnitude of the internal dark current and its dependence on the gradient were in good agreement with simulations using the cst code as well as an in-house code. Processing to a higher gradient, ~ 90 MV / m , eliminated the N = 2 mode, but the N = 1 mode persisted. The coated sidewall cavities showed the same multipactor resonances as the uncoated structure. However, at the highest gradient achieved in testing, the coated structures showed a modest reduction in the internal dark current.

43 PARTICLE ACCELERATORS↗

Measurement of internal dark current in a 17 GHz, high gradient accelerator structure

We report the measurement of the internal dark current in a 17 GHz, high gradient accelerator cavity and its comparison with theory. The cavities were fabricated from copper and had a sidewall that was either uncoated or coated with diamond-like carbon or TiN. The dark current was monitored by a downstream detector and by detectors behind two small slits made in the cavity side wall. With an increasing gradient, the downstream current increased monotonically, as expected for field emission. The variation of the internal, side dark current was not monotonic but showed the onset of peaks at gradients near 45 and 65 MV/m. These were identified as the N = 2 and N = 1 single point multipactor resonances. The total internal dark current was estimated at ∼15–30 A. The magnitude of the internal dark current and its dependence on the gradient were in good agreement with simulations using the CST code as well as an in-house code. Processing to a higher gradient, ∼90 MV/m, eliminated the N = 2 mode, but the N = 1 mode persisted. The coated sidewall cavities showed the same multipactor resonances as the uncoated structure. However, at the highest gradient achieved in testing, the coated structures showed a modest reduction in the internal dark current.

43 PARTICLE ACCELERATORS↗

High-gradient magnetic filtration of UO 2 colloids from aqueous suspensions

Environmental samples often contain innocuous components that make trace actinide analysis difficult and expensive. Therefore, it is expedient to separate these materials from actinide particles. One characteristic of many actinides is that they are paramagnetic. High-gradient magnetic filtration (HGMF) is a non-destructive technique that selectively captures magnetic constituents from a matrix containing non-magnetic species. Here, in this work, a novel HGMF device made of a permanent magnet array was used to effectively separate UO 2 particles from undesirable soil species. Up to 88% of the UO 2 particles present in suspensions were effectively captured by HGMF, resulting in their enrichment and a substantial reduction in the concentrations of other constituents.

Actinide separations↗

Improved high-gradient performance for medium-velocity superconducting half-wave resonators: Surface preparation and trapped flux mitigation

A development effort to improve the performance of superconducting radio-frequency half-wave resonators (SRF HWRs) is underway at the Facility for Rare Isotope Beams (FRIB), where 220 such resonators are in operation. Our goal was to achieve an intrinsic quality factor (𝑄 0 ) of ≥ 2 × 10 10 at an accelerating gradient (𝐸 acc ) of 12 MV/m. FRIB production resonators were prepared with buffered chemical polishing. First trials of electropolishing (EP) and post-EP low-temperature baking of FRIB HWRs allowed us to reach higher gradient (15 MV/m, limited by quench) with a higher quality factor at high gradient, but 𝑄 0 was still below our goal. Trapped magnetic flux during the Dewar test was found to be a source of 𝑄 0 reduction. Three strategies were used to reduce the trapped flux: (i) adding a local magnetic shield (LMGS) to supplement the “global” magnetic shield around the Dewar for reduction of the ambient magnetic field; (ii) performing a “uniform cooldown” (UC) to reduce the thermoelectric currents; and (iii) using a compensation coil to further reduce the ambient field with active field cancellation (AFC). The LMGS improved the 𝑄 0 , but not enough to reach our goal. With UC and AFC, we exceeded our goal, reaching 𝑄 0 = 2.8 ×10 10 at 𝐸 acc = 12 MV/m.

Cryogenics & vacuum technology↗