Search NASA⌕ Search

SEARCH · Search NASA

Results for “High resolution X-ray diffraction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Instrument design and test results of the new all-reflection spatial heterodyne spectrometer

An all-reflection spatial heterodyne spectrometer (SHS) has been recently developed. The advantages over conventional high-resolution grating spectrometers are that the SHS requires no mechanical scanning, a self-compensating optical design permits easy alignment, and it is much smaller than other spectrometers of comparable resolution. Since all beam-splits and recombinations occur by reflection off of a diffraction grating, the interferometer is capable of operating well into the extreme ultraviolet (EUV) and possibly into the soft X-ray region. A description of the design and the characteristics of the instrument is presented. Also, test results, including sample interferograms as well as their Fourier-transformed spectra, at both visible and UV wavelengths are shown. Finally, we report on future developments and possible applications.

Bush, Brett C.↗

X-ray optics - A technique for high resolution imaging

Both scattering and figure errors in grazing incidence optics are larger in the plane of incidence than out-of-plane by a factor equal to 1/sin theta, where theta is the graze angle. When the full annular aperture of a grazing incidence telescope is stopped down, the point spread function becomes highly elliptical with a width as much as sin theta times narrower than the full image. In practice, this means that improvements in resolution of up to 100 times can be achieved, and effective resolution can approach the diffraction limit. Laboratory data demonstrating the effect are presented.

Cash, Webster↗

Perfectly Cold Crystals: What Happens When They Are X-rayed?

For many macromolecular crystals the cryo-preservation of these crystals during X-ray data collection is of crucial importance, particularly at synchrotron facilities where the crystals rapidly receive a high dose of radiation. A practical variable to ensure adequate preservation is the variation of the cryo-protectant present when the crystal is preserved. Our initial approach to study X-ray diffraction data quality as a function of cryo-protectant present when preserving a xylose isomerase crystal shows that the data quality can be tremendously improved by recipe adjustment. Guided by crystal mosaicity estimates, we optimized crystal growth conditions to obtain cryo-preserved xylose isomerase crystals that withstand a very high dose of X-rays, with only the smallest amount of radiation damage at ultra-high resolution (1.2Angstroms). The rate at which damage occurs allowed us to collect a series of complete data sets, which show how the data degradation proceeds over time. We are here presenting data for the xylose isomerase crystallization recipe improvement and our interpretation of the crystal degradation process during X-ray data collection.

vanderWoerd, Mark↗

Acquisition of a High Resolution Field Emission Scanning Electron Microscope for the Analysis of Returned Samples

This grant furnished funds to purchase a state-of-the-art scanning electron microscope (SEM) to support our analytical facilities for extraterrestrial samples. After evaluating several instruments, we purchased a JEOL 6500F thermal field emission SEM with the following analytical accessories: EDAX energy-dispersive x-ray analysis system with fully automated control of instrument and sample stage; EDAX LEXS wavelength-dispersive x-ray spectrometer for high sensitivity light-element analysis; EDAX/TSL electron backscatter diffraction (EBSD) system with software for phase identification and crystal orientation mapping; Robinson backscatter electron detector; and an in situ micro-manipulator (Kleindiek). The total price was $550,000 (with $150,000 of the purchase supported by Carnegie institution matching funds). The microscope was delivered in October 2002, and most of the analytical accessories were installed by January 2003. With the exception of the wavelength spectrometer (which has been undergoing design changes) everything is working well and the SEM is in routine use in our laboratory.

Nittler, Larry R.↗

Freely Suspended Smectic Filaments and the Structure of the B7 Phase of MHOBOW

Our recent discovery of the spontaneous formation of chiral domains in fluid smectic phases of achiral bow-shaped molecules opens up a wide variety of possibilities for new liquid crystal phases and phenomena. The basic, spontaneously chiral layer structure of the highest temperature fluid smectic phases, the B2 and B7, are shown. One of the most intriguing aspects of this structure is the plethora of possible phases coming from different stacking sequences of the polar ordering and tilt directions. The four possibilities of next-nearest neighbor alternation are shown. In the original material studied, NOBOW, the ground states found are antiferroelectric, either the racemic SmC(sub S)P(sub A) or the chiral SmC(sub A)P(sub A). We are currently studying MHOBOW, synthesized by D. Walba which, by virtue of its methyl hexyloxy tail has a tendency to form anticlinic layer interfaces, in the hope of finding a phase with a ferroelectric ground state, either SmC(sub A)P(sub S) or SmC(sub S)P(sub A), which can be obtained in NOBOW only by applying a field. Preliminary observations of MHO-BOW have made its study, from the point of view of understanding novel LC structures, extremely high priority. The following truly remarkable characteristics have been revealed: (i) The smectic phase grows out of the isotropic in the form of helical ribbons. The resulting planar aligned textures of focal conics with layers normal to glass plates exhibit bizarre modulations, including stripes and checker-boards. These have also been seen in other materials suggesting that this is a new phase (tentatively called B7), which is a fluid smectic with some kind of in-layer structure. (ii) It is virtually impossible to make freely suspended films of MHOBOW. Rather it makes the freely suspended filaments which preliminary x-ray scattering experiments reveal to have the nested cylinder layer structure indicated; (iii) The powder x-ray diffraction exhibits four resolution-limited smectic layering peaks, very close in layer spacing, which vary continuously with T. This is further evidence for a more complex three dimensional structure than NOBOW, which has a typical single layering reflection. (iv) The x-ray structure factor of the layering peak of the filaments is extraordinarily complex and rich. Varying in qL (the scattering vector component along the filament axis) from a double slit-like pattern to modulated layer-like patterns, as qH (the scattering vector component normal to the filament axis) is varied over the range where the four powder peaks are located. These results suggest some kind of mosaic structure, perhaps with different layer spacings corresponding to the different stacking sequences. Recent x-ray diffraction experiments show that the peaks are modulated in intensity upon translation along a filament, in domains of several hundred microns dimension. These preliminary experiments suggest that the B7 is a fluid smectic with extremely unusual and fascinating structures. Of all of the many hundreds of fluid smectic materials we have attempted to study in the freely suspended film geometry over the years, only a few have failed to form films, and none showed any great tendency to form filaments, although this clearly should be a possible freely suspended smectic LC morphology. On several occasions in the past we have intentionally tried to make filaments from a variety of smectics without success. Thus the smectic filament formation property makes the B7 phase unique. It seems quite likely that the stability of filaments is related to the in-plane structure. The filaments exhibit other interesting structural and optical features. They are birefringent with a local optic axis which is oblique and which can vary continuously along filament and which can be manipulated with an electric field applied normal to the fiber, as if the field were causing a rotation of the optic axis about the fiber axis. Rapid displacement of the ends of the fiber toward one another causes a macroscopic helixing at low T and causes thick regions to transiently appear at high T, a 1D analog of island formation on a rapidly compressed film.

Clark, N.↗

Nature and origin of interstellar diamond from the Allende CV3 meteorite

Data and experimental evidence which support the contention that the C delta diamonds may result from grain-grain collisions in supernova shocks in the interstellar medium are presented. Fragments of the Allende CV3 chondrite were acid-treated. A whitish powder was obtained. For the Analytical Electron Microscopy (AEM) a small drop of ethanol suspension was transferred onto holey carbon support films on 3 mm EM grids. The AEM was performed on transmission-thin fragments of the material which overlay holes in the film, to eliminate interference from the substrate. Electron Spectroscopy for Chemical Analysis (ESCA) was performed on a large aliquot of C. Diamond was identified by selected area electron diffraction. Scanning Transmission Electron Microscope / Energy Dispersive X-ray (STEM-EDS) microanalyses of the C delta diamond, using a light-element detector, show that oxygen and possibly nitrogen are the only impurities consistently present. ESCA spectra from bulk C delta material confirm the presence of N at a level of 0.35 percent or less. Under UV irradiation a yellow-red fluorescence is observed, consistent with that of natural diamonds containing substitutional N. Electron Energy Loss Spectra (EELS) were recorded at 2 eV resolution from the C delta diamond, high pressure synthetic diamond, a diamond film produced in a low pressure plasma by chemical vapor deposition (CVD) on a heated silicon substrate (Roy, 1987), graphite, and amorphous arc sputtered carbon. Comparison of the carbon K edge shape and fine structure shows the Allende C delta phase to be largely diamond, but with a significant pre-edge absorption feature indicative of transitions of C 1s electrons into pi asterisk orbitals which are absent in the purely sp(3)-bonded diamond but present in graphite and amorphous carbon.

Blake, David↗

Optical Performance Modeling of FUSE Telescope Mirror

We describe the Metrology Data Processor (METDAT), the Optical Surface Analysis Code (OSAC), and their application to the image evaluation of the Far Ultraviolet Spectroscopic Explorer (FUSE) mirrors. The FUSE instrument - designed and developed by the Johns Hopkins University and launched in June 1999 is an astrophysics satellite which provides high resolution spectra (lambda/Delta(lambda) = 20,000 - 25,000) in the wavelength region from 90.5 to 118.7 nm The FUSE instrument is comprised of four co-aligned, normal incidence, off-axis parabolic mirrors, four Rowland circle spectrograph channels with holographic gratings, and delay line microchannel plate detectors. The OSAC code provides a comprehensive analysis of optical system performance, including the effects of optical surface misalignments, low spatial frequency deformations described by discrete polynomial terms, mid- and high-spatial frequency deformations (surface roughness), and diffraction due to the finite size of the aperture. Both normal incidence (traditionally infrared, visible, and near ultraviolet mirror systems) and grazing incidence (x-ray mirror systems) systems can be analyzed. The code also properly accounts for reflectance losses on the mirror surfaces. Low frequency surface errors are described in OSAC by using Zernike polynomials for normal incidence mirrors and Legendre-Fourier polynomials for grazing incidence mirrors. The scatter analysis of the mirror is based on scalar scatter theory. The program accepts simple autocovariance (ACV) function models or power spectral density (PSD) models derived from mirror surface metrology data as input to the scatter calculation. The end product of the program is a user-defined pixel array containing the system Point Spread Function (PSF). The METDAT routine is used in conjunction with the OSAC program. This code reads in laboratory metrology data in a normalized format. The code then fits the data using Zernike polynomials for normal incidence systems or Legendre-Fourier polynomials for grazing incidence systems. It removes low order terms from the metrology data, calculates statistical ACV or PSD functions, and fits these data to OSAC models for the scatter analysis. In this paper we briefly describe the laboratory image testing of FUSE spare mirror performed in the near and vacuum ultraviolet at John Hopkins University and OSAC modeling of the test setup performed at NASA/GSFC. The test setup is a double-pass configuration consisting of a Hg discharge source, the FUSE off-axis parabolic mirror under test, an autocollimating flat mirror, and a tomographic imaging detector. Two additional, small fold flats are used in the optical train to accommodate the light source and the detector. The modeling is based on Zernike fitting and PSD analysis of surface metrology data measured by both the mirror vendor (Tinsley) and JHU. The results of our models agree well with the laboratory imaging data, thus validating our theoretical model. Finally, we predict the imaging performance of FUSE mirrors in their flight configuration at far-ultraviolet wavelengths.

Saha, Timo T.↗

High Resolution X-ray Imaging

NAG5-5020 covered a period of 7.5 years during which a great deal of progress was made in x-ray optical techniques under this grant. We survived peer review numerous times during the effort to keep the grant going. In 1994, when the grant started we were actively pursuing the application of spherical mirrors to improving x-ray telescopes. We had found that x-ray detectors were becoming rapidly more sophisticated and affordable, but that x-ray telescopes were only being improved through the intense application of money within the AXAF program. Clearly new techniques for the future were needed. We were successful in developing and testing at the HELSTF facility in New Mexico a four reflection coma-corrected telescope made from spheres. We were able to demonstrate 0.3 arcsecond resolution, almost to the diffraction limit of the system. The community as a whole was, at that time, not particularly interested in looking past AXAF (Chandra) and the effort needed to evolve. Since we had reached the diffraction limit using non-Wolter optics we then decided to see if we could build an x-ray interferometer in the laboratory. In the lab the potential for improved resolution was substantial. If synthetic aperture telescopes could be built in space, then orders of magnitude improvement would become feasible. In 1998 NASA, under the direction of Dr. Nick White of Goddard, started a study to assess the potential and feasibility of x-ray interferometry in space. My work became of central interest to the committee because it indicated that such was possible. In early 1999 we had the breakthrough that allowed us build a practical interferometer. By using flats and hooking up with the Marshall Space Flight Center facilities we were able to demonstrate fringes at 1.25keV on a one millimeter baseline. This actual laboratory demonstration provided the solid proof of concept that NASA needed.

Cash, Webster↗

High Resolution X-ray Imaging

NAG5-5020 covered a period of 7.5 years during which a great deal of progress was made in x-ray optical techniques under this grant. We survived peer review numerous times during the effort to keep the grant going. In 1994, when the grant started we were actively pursuing the application of spherical mirrors to improving x-ray telescopes. We had found that x-ray detectors were becoming rapidly more sophisticated and affordable, but that x-ray telescopes were only being improved through the intense application of money within the AXAF program. Clearly new techniques for the future were needed. We were successful in developing and testing at the HELSTF facility in New Mexico a four reflection coma-corrected telescope made from spheres. We were able to demonstrate 0.3 arcsecond resolution, almost to the diffraction limit of the system. The community as a whole was, at that time, not particularly interested in looking past AXAF (Chandra) and the effort needed to evolve. Since we had reached the diffraction limit using non-Wolter optics we then decided to see if we could build an x-ray interferometer in the laboratory. In the lab the potential for improved resolution was substantial. If synthetic aperture telescopes could be built in space, then orders of magnitude improvement would become feasible. In 1998 NASA, under the direction of Dr Nick White of Goddard, started a study to assess the potential and feasibility of x-ray interferometry in space. My work became of central interest to the committee because it indicated that such was possible. In early 1999 we had the breakthrough that allowed us build a practical interferometer. By using flats and hooking up with the Marshall Space Flight Center facilities we were able to demonstrate fringes at 1.25keV on a one millimeter baseline. This actual laboratory demonstration provided the solid proof of concept that NASA needed. As the year progressed the future of x-ray astronomy jelled around the Maxim program. Maxim is a set of two major x-ray astronomy missions based on the concepts I developed and demonstrated under this SR&T grant. The first Maxim is to image the sky at 100 micro-arcsecond resolution. That is one thousand times higher resolution than Hubble. The full Maxim has the ultimate goal of imaging the event horizon of a black hole in an active galactic nucleus (ALAN). This will require 0.1 micro-arcsecond resolution - one million times higher than Hubble! Nonetheless, using the techniques developed under this grant, it has become possible. Maxim Pathfinder is now in the NASA planning for a new start in approximately 20 10. The full Maxim is carried as a vision mission for the post 2015 timeframe. Finally, this grant is the evolved version of the SR&T grant we carried during the 1980s and up to 1994. At that point in time this grant was also working on x-ray optics, but concentrating on x-ray spectroscopy. The techniques developed by 1990 were not chosen for use on Chandra or XMM-Newton because they were too new. During the last year, however, the Constellation-X mission recognized the need for better spectroscopy techniques and tapped our expertise. We were able to support the initial work on Con-X through this program. It now appears that the off-plane mount will be used in Con-X, increasing performance and decreasing cost and risk.

Cash, Webster↗

Organization of P, S, and Fe Inclusions in a Freshwater Magnetococcus

Magnetotactic bacteria are a heterogeneous group of motile, mainly aquatic procaryotes that align and swim along geomagnetic field lines. They are of interest to astrobiologists because of the magnetite crystals found in the Mars meteorite ALH84001 which share many characteristics with the magnetite produced intracellularly by magnetotactic bacteria. These bacteria are diverse morphologically, physiologically and phylogenetically, sharing a few key characteristics: 1) the presence of intracellular membrane-bound magnetic crystals (magnetosomes), usually but not always arranged in chains; 2) motility by means of flagella; and 3) microaerophillic or anaerobic physiology. The bilophotrichous (having two flagella bundles) magnetotactic cocci (MC) are ubiquitous in aquatic habitats but have proven extremely difficult to cultivate. Because only several marine strains have been isolated and grown in axenic culture, little is known about the physiology and the biogeochemical roles of the MC. We studied the composition and distribution of intracellular structures in an uncultured MC, designated ARB-1. To do this, a combination of light microscopy, environmental scanning electron microscopy (ESEM), transmission electron microscopy (TEM) and energy dispersive X-ray spectroscopy (EDS) were used. Cells of ARB-1 were separated from sediments collected from Baldwin Lake (Los Angeles Arboretum, Arcadia, CA). They are large spherical to oblate spheroidal Gram-negative cells, ranging from 1 to 4 micrometers along the maximum dimension, which is perpendicular to the direction of swimming. Cells have two large phosphorus-containing inclusions that comprise a large percentage of the cell volume. Many smaller sulfur inclusions are located at the convex end of the cell. Most of the cellular Fe is present in the magnetosomes. These may be arranged as a clump at the concave end of the cell, near the two flagella bundles, or as chains, or as both a clump and chains. The magnetosomes were identified as magnetite (Fe3O4) by selected area electron diffraction (SAED) and high resolution TEM. We saw a trend between cell size and organization of the magnetosomes. Smaller, more spherical cells were more likely to have chains than were larger, more oblate cells. This may indicate different populations of cells, or it may be attributed to variations in cell growth cycle. The size distribution (length) of magnetosomes in chains was similar to that of magnetosomes in clusters, except that there was a larger size range for clustered magnetosomes. Magnetosomes from ARB-1 cells average 82 nm in length. If plotted on a graph of length as a function of aspect ratio, they fall within the single domain region of the plot. If compared with the size distributions of magnetite from ALH84001 and magnetosomes from the cultured magnetotactic vibrio MV-1, the magnetites produced by ARB-1 cells are, on average, larger and have a wider range of aspect ratio. ARB-1 cells have a specific organization of the P, S, and Fe inclusions. The P inclusions always occupy the majority of the cell volume and separate the S inclusions from the disorganized clumps of magnetosomes and the flagella bundles. The P inclusions may contain polyphosphate, which could play several roles in motility, adaptation to stress, growth and division, buoyancy, and energy. The S inclusions might be a way to store S, a potential energy source, when the cells move from sulfide to oxygen zones. The consistency of P, S, and Fe organization in ARB-1 cells suggests that these inclusions have some specific and interactive functions.

Cox, Lea↗

Convective flow effects on protein crystal growth

A high-resolution microscopic interferometric setup for the monitoring of protein morphologies has been developed. Growth or dissolution of a crystal can be resolved with a long-term depth resolution of 200 A and a lateral resolution of 2 microns. This capability of simultaneously monitoring the interfacial displacement with high local depth resolution has yielded several novel results. We have found with lysozyme that (1) the normal growth rate is oscillatory, and (2) depending on the impurity content of the solution, the growth step density is either greater or lower at the periphery of a facet than in its center. The repartitioning of Na plus and Cl minus ions between lysozyme solutions and crystals was studied for a wide range of crystallization conditions. A nucleation-growth-repartitioning model was developed, to interpret the large body of data in unified way. The results strongly suggest that (1) the ion to lysozyne ratio in the crystal depends mostly on kinetic rather than crystallographic parameters, and (2) lysozyme crystals possess a salt-rich core with a diameter electron microscopy results appear to confirm this finding, which could have far-reaching consequences for x-ray diffraction studies. A computational model for diffusive-convective transport in protein crystallization has been applied to a realistic growth cell geometry, taking into account the findings of the above repartitioning studies and our kinetics data for the growth of lysozyme. The results show that even in the small cell employed, protein concentration nonuniformities and gravity-driven solutal convection can be significant. The calculated convection velocities are of the same order to magnitude as those found in earlier experiments. As expected, convective transport, i.e., at Og, lysozyme crystal growth remains kinetically limited. The salt distribution in the crystal is predicted to be non-uniform at both 1g and 0g, as a consequence of protein depletion in the solution. Static and dynamic light scattering studies in undersaturated and supersaturated solutions have been performed. Diffusivities in undersaturated solutions, were found to vary with lysozyme concentrations. Depending on the salt concentration, the diffusivities either increase or decrease. Interestingly, the corresponding static scattering intensities behave oppositely, Our current analysis indicates that these changes are inconsistent with aggregation in undersaturated solutions. However, the data are compatible with concentration-dependent changes of the interactions between protein and salt.

Rosenberger, Franz↗

Large scale crystallization of protein pharmaceuticals in microgravity via temperature change

The major objective of this research effort is the temperature driven growth of protein crystals in large batches in the microgravity environment of space. Pharmaceutical houses are developing protein products for patient care, for example, human insulin, human growth hormone, interferons, and tissue plasminogen activator or TPA, the clot buster for heart attack victims. Except for insulin, these are very high value products; they are extremely potent in small quantities and have a great value per gram of material. It is feasible that microgravity crystallization can be a cost recoverable, economically sound final processing step in their manufacture. Large scale protein crystal growth in microgravity has significant advantages from the basic science and the applied science standpoints. Crystal growth can proceed unhindered due to lack of surface effects. Dynamic control is possible and relatively easy. The method has the potential to yield large quantities of pure crystalline product. Crystallization is a time honored procedure for purifying organic materials and microgravity crystallization could be the final step to remove trace impurities from high value protein pharmaceuticals. In addition, microgravity grown crystals could be the final formulation for those medicines that need to be administered in a timed release fashion. Long lasting insulin, insulin lente, is such a product. Also crystalline protein pharmaceuticals are more stable for long-term storage. Temperature, as the initiation step, has certain advantages. Again, dynamic control of the crystallization process is possible and easy. A temperature step is non-invasive and is the most subtle way to control protein solubility and therefore crystallization. Seeding is not necessary. Changes in protein and precipitant concentrations and pH are not necessary. Finally, this method represents a new way to crystallize proteins in space that takes advantage of the unique microgravity environment. The results from two flights showed that the hardware performed perfectly, many crystals were produced, and they were much larger than their ground grown controls. Morphometric analysis was done on over 4,000 crystals to establish crystal size, size distribution, and relative size. Space grown crystals were remarkably larger than their earth grown counterparts and crystal size was a function of PCF volume. That size distribution for the space grown crystals was a function of PCF volume may indicate that ultimate size was a function of temperature gradient. Since the insulin protein concentration was very low, 0.4 mg/ml, the size distribution could also be following the total amount of protein in each of the PCF's. X-ray analysis showed that the bigger space grown insulin crystals diffracted to higher resolution than their ground grown controls. When the data were normalized for size, they still indicated that the space crystals were better than the ground crystals.

Long, Marianna M.↗

Holographic Optical Data Storage

Although the basic idea may be traced back to the earlier X-ray diffraction studies of Sir W. L. Bragg, the holographic method as we know it was invented by D. Gabor in 1948 as a two-step lensless imaging technique to enhance the resolution of electron microscopy, for which he received the 1971 Nobel Prize in physics. The distinctive feature of holography is the recording of the object phase variations that carry the depth information, which is lost in conventional photography where only the intensity (= squared amplitude) distribution of an object is captured. Since all photosensitive media necessarily respond to the intensity incident upon them, an ingenious way had to be found to convert object phase into intensity variations, and Gabor achieved this by introducing a coherent reference wave along with the object wave during exposure. Gabor's in-line recording scheme, however, required the object in question to be largely transmissive, and could provide only marginal image quality due to unwanted terms simultaneously reconstructed along with the desired wavefront. Further handicapped by the lack of a strong coherent light source, optical holography thus seemed fated to remain just another scientific curiosity, until the field was revolutionized in the early 1960s by some major breakthroughs: the proposition and demonstration of the laser principle, the introduction of off-axis holography, and the invention of volume holography. Consequently, the remainder of that decade saw an exponential growth in research on theory, practice, and applications of holography. Today, holography not only boasts a wide variety of scientific and technical applications (e.g., holographic interferometry for strain, vibration, and flow analysis, microscopy and high-resolution imagery, imaging through distorting media, optical interconnects, holographic optical elements, optical neural networks, three-dimensional displays, data storage, etc.), but has become a prominent am advertising, and security medium as well. The evolution of holographic optical memories has followed a path not altogether different from holography itself, with several cycles of alternating interest over the past four decades. P. J. van Heerden is widely credited for being the first to elucidate the principles behind holographic data storage in a 1963 paper, predicting bit storage densities on the order of 1/lambda(sup 3) with source wavelength lambda - a fantastic capacity of nearly 1 TB/cu cm for visible light! The science and engineering of such a storage paradigm was heavily pursued thereafter, resulting in many novel hologram multiplexing techniques for dense data storage, as well as important advances in holographic recording materials. Ultimately, however, the lack of such enabling technologies as compact laser sources and high performance optical data I/O devices dampened the hopes for the development of a commercial product. After a period of relative dormancy, successful applications of holography in other arenas sparked a renewed interest in holographic data storage in the late 1980s and the early 1990s. Currently, with most of the critical optoelectronic device technologies in place and the quest for an ideal holographic recording medium intensified, holography is once again considered as one of several future data storage paradigms that may answer our constantly growing need for higher-capacity and faster-access memories.

Timucin, Dogan A.↗

A liquid radiation detector with high spatial resolution

Detector, using point anode, minimizes problem of oblique tracks by permitting construction of very thin counter. Detector is useful in cosmic ray and high energy physics research and X-ray and neutron diffraction technology.

Alvarez, L.↗

Echelle spectrographs at grazing incidence

It is shown that by using the conical diffraction mount, existing echelle gratings can be used at grazing incidence to achieve high spectral resolution in the extreme UV and soft X rays. Design considerations for grazing incidence echelle spectrographs are examined, and two sample designs are discussed. The first, for use in the extreme UV, has a primary mirror and an entrance slit to the spectrograph. The system has a resolution of 10,000, operates at any wavelength longward of 100 A, and covers 30% of the spectrum at a single setting. The X-ray spectrograph uses objective gratings to obtain spectral resolution of 28,000 over any factor of 2 in. wavelength. It operates to wavelengths as short as 4 A.

Cash, W.↗

High efficiency spectrographs for the EUV and soft X-rays

The use of grazing incidence optics and reflection grating designs is shown to be a method that improves the performance of spectrographs at wavelengths shorter than 1200 A. Emphasis is laid on spectroscopic designs for X ray and EUV astronomy, with sample designs for an objective reflection grating spectrograph (ORGS) and an echelle spectrograph for wavelengths longer than 100 A. Conical diffraction allows operations at grazing incidence in the echelle spectrograph. In ORGS, the extreme distance of X ray objects aids in collimating the source radiation, which encounters conical diffraction within the instrument, proceeds parallel to the optical axis, and arrives at the detector. A series of gratings is used to achieve the effect. A grazing echelle is employed for EUV observations, and offers a resolution of 20,000 over a 300 A bandpass.

Cash, W.↗

Base pairing and base mis-pairing in nucleic acids

In recent years we have learned that DNA is conformationally active. It can exist in a number of different stable conformations including both right-handed and left-handed forms. Using single crystal X-ray diffraction analysis we are able to discover not only additional conformations of the nucleic acids but also different types of hydrogen bonded base-base interactions. Although Watson-Crick base pairings are the predominant type of interaction in double helical DNA, they are not the only types. Recently, we have been able to examine mismatching of guanine-thymine base pairs in left-handed Z-DNA at atomic resolution (1A). A minimum amount of distortion of the sugar phosphate backbone is found in the G x T pairing in which the bases are held together by two hydrogen bonds in the wobble pairing interaction. Because of the high resolution of the analysis we can visualize water molecules which fill in to accommodate the other hydrogen bonding positions in the bases which are not used in the base-base interactions. Studies on other DNA oligomers have revealed that other types of non-Watson-Crick hydrogen bonding interactions can occur. In the structure of a DNA octamer with the sequence d(GCGTACGC) complexed to an antibiotic triostin A, it was found that the two central AT base pairs are held together by Hoogsteen rather than Watson-Crick base pairs. Similarly, the G x C base pairs at the ends are also Hoogsteen rather than Watson-Crick pairing. Hoogsteen base pairs make a modified helix which is distinct from the Watson-Crick double helix.

Wang, A. H. J.↗

High Resolution X-ray Imaging

Improved image quality is of central importance to the future of X ray astronomy. We show that the optical tolerances necessary to push the quality of grazing incidence telescopes well beyond their current one arcsecond limit, are achievable. We also discuss a new approach to X ray optics that has been under development and is already showing resolution as high a 0.1 arcseconds. We argue that diffraction limited resolution should be considered as a viable goal for a new start among the next generation observatories, and follow the line of reasoning into X ray interferometry as a long term goal.

Cash, Webster↗