Search NASA⌕ Search

SEARCH · Search NASA

Results for “Isotope Ratio Mass Spectrometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Isotope Ratio Monitoring Gas Chromatography Mass Spectrometry (IRM-GCMS)

On Earth, the C-13 content of organic compounds is depleted by roughly 13 to 23 permil from atmospheric carbon dioxide. This difference is largely due to isotope effects associated with the fixation of inorganic carbon by photosynthetic organisms. If life once existed on Mars, then it is reasonable to expect to observe a similar fractionation. Although the strongly oxidizing conditions on the surface of Mars make preservation of ancient organic material unlikely, carbon-isotope evidence for the existence of life on Mars may still be preserved. Carbon depleted in C-13 could be preserved either in organic compounds within buried sediments, or in carbonate minerals produced by the oxidation of organic material. A technique is introduced for rapid and precise measurement of the C-13 contents of individual organic compounds. A gas chromatograph is coupled to an isotope-ratio mass spectrometer through a combustion interface, enabling on-line isotopic analysis of isolated compounds. The isotope ratios are determined by integration of ion currents over the course of each chromatographic peak. Software incorporates automatic peak determination, corrections for background, and deconvolution of overlapped peaks. Overall performance of the instrument was evaluated by the analysis of a mixture of high purity n-alkanes of know isotopic composition. Isotopic values measured via IRM-GCMS averaged withing 0.55 permil of their conventionally measured values.

Freeman, K. H.↗

Practical considerations for amino acid isotope analysis

Over the last few decades, isotopic analysis of amino acids at the compound- and position-specific levels has been rapidly advancing across diverse fields. As these techniques progress, evaluation of isotopic fractionation associated with sample workup is essential. This critical review of analytical methods through the lens of isotope geochemistry provides a benchmark for researchers across disciplines seeking to make compound- and position-specific amino acid isotope measurements. We focus on preparation, acid hydrolysis, clean-up, derivatization, separation, and C, H, N, and S isotope measurement. Despite substantial customizability across these steps, the following general recommendations should maximize recovery while minimizing isotopic fractionation. Samples should be freeze-dried and stored anoxically at ≤ –20 °C prior to conventional acid hydrolysis (6N HCl, 110 °C, 20–24 h, anoxic), which suffices for many residues. Both gas and liquid chromatographic (GC and LC, respectively) techniques are well-established and separate about 15 amino acids; LC bypasses the need for derivatization, while GC provides higher sensitivity. Furthermore, when derivatization is needed, n-acetyl and alkoxycarbonyl esters provide the most reproducible C isotope ratios. For compound-specific analyses, online GC–IRMS and LC–IRMS systems offer the easiest workflow, but EA–IRMS enables potential multi-element isotope analysis. Emerging techniques like high-resolution mass spectrometry are also promising for multi-element analysis and recover position-specific isotopic information. Looking forward to the next decade of innovation, isotope geochemists and ecologists can improve amino acid isotope analysis by focusing on streamlining multi-element analysis and standardizing calibration practices across laboratories.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Plutonium isotope ratio measurements by total evaporation-thermal ionization mass spectrometry (TE-TIMS): an evaluation of uncertainties using traceable standards from the New Brunswick Laboratory

The accuracy and precision of isotope amount ratio measurements using thermal ionization mass spectrometry (TIMS) instrumentation are described, and the measurement of Pu materials is emphasized. The mass fractionation observed for Am, Ga, Pu, and U for isotope amount ratio measurements using the total evaporation (TE) technique is compared with theoretical estimates to demonstrate the advantage of the TE methodology and to investigate systematic biases in the major isotope amount ratios of U and Pu certified reference material (CRM) standards from the U.S. provider of CRMs. The quality of the Pu isotopic data generated by TIMS instruments in an analytical laboratory is demonstrated by the application of the double ratio technique to estimate the 241 Pu half-life. Analytical data on traceable Pu CRMs from the New Brunswick Laboratory (NBL), generated as part of routine measurements supporting various programs, are used for this half-life estimation. Although the 241 Pu abundances in CRMs of 136, 137, 138, and 126-A are approximately 200–2000× smaller than those in the 241 Pu material used in the previous Institute for Reference Materials and Measurements (IRMM) evaluation of the 241 Pu half-life, the half-life value estimated in this work shows excellent agreement with the currently accepted value from the IRMM. This agreement also demonstrates the pedigree of the Pu isotopic standards from the NBL and the quality of the isotope amount ratio measurements using TIMS instrumentation. For both the major and minor Pu isotope amount ratios, this report describes the relative importance of the factors affecting the uncertainty of TIMS measurements, which are considered the gold standard in isotope ratio measurements (LA-UR-24-29199).

07 ISOTOPE AND RADIATION SOURCES↗

High-precision measurement of U-Pu-Np-Am concentrations and isotope ratios in environmental reference materials by mass spectrometry

Herein, we report results of precise and sensitive mass spectrometric measurements of uranium, plutonium, neptunium, and americium concentrations and isotope ratios in a variety of environmental reference materials. Most of our work has been done on NIST SRM 4350b, River Sediment, but we also present results for NIST SRM 4354, Lake Sediment; NIST SRMs 4355 and 4355a, Peruvian Soil; NIST SRM 4357, Ocean Sediment; NIST SRM 1648a, Urban Particulate Material; NIST SRM 1649b, Urban Dust; IAEA CRM 385, Ocean Sediment; USGS BCR-2, Columbia River Basalt; and USGS BHVO-2, Hawaiian Volcanic Observatory Basalt. These materials reflect a wide range in long-lived actinide concentrations (e.g. 1E4 to 1E10 atoms 239 Pu/g) and isotope ratios. Measurements were performed in a clean laboratory by isotope dilution, multi-collector thermal ionization and multi-collector inductively coupled plasma mass spectrometry. In general, our results are in agreement with, but lower the uncertainty of, literature or certificate values for these reference materials. Our uranium results for the basalts also confirm previously reported high-precision mass spectrometric results from our laboratory. In many cases our measurements of U-Pu-Np-Am nuclides appear to be novel.

58 GEOSCIENCES↗

Carbon isotopic analysis of atmospheric methane by isotope-ratio-monitoring gas chromatography-mass spectrometry

Less than 15 min are required for the determination of delta C(sub PDB)-13 with a precision of 0.2 ppt(1 sigma, single measurement) in 5-mL samples of air containing CH4 at natural levels (1.7 ppm). An analytical system including a sample-introduction unit incorporating a preparative gas chromatograph (GC) column for separation of CH4 from N2, O2, and Ar is described. The 15-min procedure includes time for operation of that system, high-resolution chromatographic separation of the CH4, on-line combustion and purification of the products, and isotopic calibration. Analyses of standards demonstrate that systematic errors are absent and that there is no dependence of observed values of delta on sample size. For samples containing 100 ppm or more CH4, preconcentration is not required and the analysis time is less than 5 min. The system utilizes a commercially available, high-sensitivity isotope-ratio mass spectrometer. For optimal conditions of smaple handling and combustion, performance of the system is within a factor of 2 of the shot-noise limit. The potential exists therefore for analysis of samples as small as 15 pmol CH4 with a standard deviation of less than 1 ppt.

Merritt, Dawn A.↗

Lead Isotope Fingerprinting of Nanoscale Mineral Particles via Single Particle Inductively Coupled Plasma Mass Spectrometry

Determining lead (Pb) isotopic ratios is of broad interest across chemical disciplines for source tracing and age determinations, but the technique is inherently limited when multiple sources of Pb are present in a single sample. Single particle methods offer a solution to directly resolve multiple distinct isotopic ratios within individual samples. In this study, single particle inductively coupled plasma-mass spectrometry (spICP-MS) was performed using time-of-flight (TOF) and multicollector (MC)-based platforms to measure the Pb isotopic composition of individual nanoscale particles. Distinct Pb isotope ratios were measured in particles from four powdered galena samples of different origins (average single-particle 206Pb/207Pb ratios ranging from 0.91 to 1.28) using both the TOF and the MC-based platforms. Differentiation of galena particles in a mixture (liberated grains and those hosted in a silicate matrix) was possible due to detecting their unique multielemental fingerprints. The differing behavior of the two galena samples during digestion was investigated; undigested galena particles trapped within silicate minerals were detected using spICP-MS, which has implications for Pb recovery in bulk-scale isotopic analysis. The multinuclide detection capability of the ICP-TOF-MS instrument allowed for the simultaneous detection of secondary constituent elements within the nanoparticles and the identification of multiple populations of isotopically distinct Pb-bearing particles in a copper ore sample, whereas the increased sensitivity of the MC instrument enabled quantification of 204Pb, allowing differentiation using multiple isotopic ratios. A single particle isotope ratio analysis module was developed within an open-source spICP-TOF-MS data processing platform, enabling its adoption across chemical disciplines.

Goodman, Aaron J. [University of Montreal, Quebec,↗

Measurement of Mass-Independent Perturbations of Cadmium in Nuclear Debris Samples

The isotopic composition of cadmium in nuclear debris was measured by multi-collector inductively coupled plasma-mass spectrometry (MC-ICP-MS). Mass-independent perturbations due to fission product decay on the isotopes of Cd were observed. Relative fission yields for masses 111, 112, 114 and 116 were determined in each sample of nuclear debris and compared with reported values found in irradiated plutonium and uranium fuels. Mass spectrometry measurements of the valley fission product endpoints are extremely challenging due to the low cumulative fission yields and small amounts of each isotope that are produced. To overcome these challenges, a new purification method for Cd was developed and validated by examination of a number of geological reference materials.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Could Microplasma Ionization and Ultrahigh Mass Resolution Alleviate Chemical Separations for Elemental and Isotopic Analysis?

At the extremes, all analytical spectrometric measurements are limited by the resolution of the spectrometer system. Spectral overlaps, isobars in the case of mass spectrometry, can lead to the implementation of complex and time-consuming chemical separations to alleviate those interferences. In the area of elemental/isotopic mass spectrometry, use of sector-field instruments can provide a mass resolution of ~10,000, but still necessitate chemical separations. Described here is the coupling of the liquid sampling-atmospheric pressure glow discharge (LS-APGD) microplasma to ultra-high resolution Orbitrap mass analyzer systems to yield mass resolution values ranging from 70k to 1M. Resolution of this order, with commensurate improvements in precision and accuracy, holds the promise to affect elemental/isotopic determinations without the need for chemical separations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An approach for spent nuclear fuel containment integrity verification using gas tagging

Verification of containment integrity is required for spent nuclear fuel (SNF) managed by the commercial nuclear industry and U.S. Department of Energy (DOE), especially after extended storage. Certain SNF storage systems, such as the DOE road-ready dry storage system, hold several packaged containments within a welded over-canister. These packaged containments are called Department of Energy Standard Canisters (DOESCs). DOESC leakage identification is challenging because their containment boundary cannot be accessed for testing and their contents (i.e., SNF and fill gas) are often similar. There are concerns that this could result in costly characterization and repackaging operations of DOE road-ready dry storage systems if compromised DOESCs are suspected. Here, to address these concerns, this paper presents an approach for applying a gas tagging process using xenon to uniquely identify compromised inaccessible containments following extended storage. The containments considered for this application are seven DOESCs, each packaged within a single over-canister. Two different SNF loading configurations from the Advanced Test Reactor and Fort Saint Vrain nuclear power plant are considered. These configurations are used to represent research reactor aluminum-clad spent nuclear fuel (ASNF) and TRi-structural ISOtropic (TRISO) SNF types. Results for this application show that for ASNF and TRISO type fuels for which the selected fuels are representative, the volume of taggant required at loading is determined primarily by the lower detection limit and leak rate of taggant from a compromised DOESC, rather than the amount of fission-generated xenon in the loaded fuel. While the application presented is suited for larger leaks, smaller leaks could be detected by modifying certain design parameters. This gas tagging approach can also be applied to other DOE containments and advanced reactor SNF storage systems.

07 - ISOTOPES AND RADIATION SOURCES↗

Parametric optimization of the liquid sampling-atmospheric pressure glow discharge ionization source coupled to an Orbitrap mass spectrometer for neodymium isotope ratio determinations

Isotope ratio determinations are a valuable tool in several application areas. In nuclear forensics, the isotope ratios of uranium and plutonium are commonly used as a signature for the nuclear material's provenance and processing history. However, signatures from other coexisting elements, such as neodymium and samarium, can offer additional insights. Here, the liquid sampling-atmospheric pressure glow discharge (LS-APGD) ionization source coupled to an Orbitrap mass spectrometer (MS) has demonstrated its utility for actinide measurements. This instrumental platform can leverage the high resolution offered by the Orbitrap MS to overcome potential isobaric interferences, such as 144 Nd- 144 Sm, 148 Nd- 148 Sm, and 150 Nd- 150 Sm pairs. The work presented herein demonstrates the rapid, accurate, and precise determination of the isotope ratios for neodymium using the LS-APGD/Orbitrap MS. Both the LS-APGD and Orbitrap MS parameters were optimized systematically, with NdO + found to be the most abundant, most reduced species after applying the optimal collision-induced dissociation modalities. A limit of detection of 3 pg of 142 Nd was achieved when data was acquired and processed using the FTMS Booster, an external data acquisition and processing system offered by Spectroswiss. Excellent accuracy of better than 99 % and precision of <1 % RSD were achieved when a solution of the well-characterized neodymium standard (JNdi-1 standard) was analyzed under the optimized condition, indicating the LS-APGD/Orbitrap's great potential for isotope ratio analysis of Nd and other REEs for diverse applications.

47 OTHER INSTRUMENTATION↗

Utilization of the LS-APGD microplasma/orbitrap-FTMS booster system for detection and isotopic analysis of neodymium nanoparticles

Detection and isotopic analysis of particle populations has seen rapid growth across several application areas, including environmental analysis, nuclear forensics, and food safety. The ability to characterize the particles' unique elemental and isotopic fingerprints could provide information related to formation, processing history, and transport. Regarding nuclear forensics, isotopic analysis of particles derived from diverse materials is often used as a tool to trace the origin and processing history. Mass spectrometric-based techniques currently used for particle population analysis often suffer from limited mass resolution, particularly when dealing with real-world samples that are affected by isobaric and polyatomic interferences from the matrix. To address these analytical challenges, we propose a novel method utilizing the liquid sampling-atmospheric pressure glow discharge (LS-APGD) microplasma ionization source coupled to an ultrahigh resolution Orbitrap mass spectrometer, further enhanced with the FTMS X2T Booster data acquisition and processing unit. The FTMS Booster enables acquisition of extended transient times of up to 3 s, significantly improving mass resolution, thereby reducing or even eliminating the need for prior separation of isobaric or polyatomic interferences. Additionally, the detection of low-abundance isotopes was improved by increasing the signal-to-noise (S/N) ratio. As proof of concept, this study demonstrates the feasibility of the LS-APGD/Orbitrap-FTMS X2T Booster platform for direct analysis using a suspension of well-characterized ∼120 nm neodymium particles. The quality of the isotope ratios values obtained from a few hundred particles were in good agreement with those obtained from homogeneous ionic solutions. These results highlight the potential of the LS-APGD/Orbitrap platform for rapid, accurate, and interference-resilient isotope ratio analysis of particle populations without the need for dissolution and subsequent chemical separations, offering significant advantages for nuclear forensics, safeguards, and environmental applications. The effort here also points to further paths forward, hopefully towards single particle (SP) analysis using microplasma ionization and the ultrahigh resolving power of the Orbitrap mass analyzer.

FTMS X2T booster↗

Assessment of Low-Level Pu Isotope Ratio Measurements Using Multicollector Inductively Coupled Plasma Mass Spectrometry (MC-ICP-MS/MS) Equipped with a Pre-Mass Filter

We present an initial investigation into the performance of a multicollector inductively coupled plasmamass spectrometer equipped with a pre-mass filter (Neoma MC-ICP-MS/MS) for making plutonium (Pu) isotope ratio measurements on solutions containing low level (i.e., pg mL –1 ) Pu concentrations. This assessment was achieved by comparison of the 240 Pu/ 239 Pu, 241 Pu/ 239 Pu, and 242 Pu/ 239 Pu ratios attained over a one month period on the MC-ICP-MS/MS with the long-term (∼1 year) performance observed on the predecessor MC-ICP-MS (Neptune Plus) instrument each equipped with an equipped with an APEXΩ desolvating nebulizer for repeated measurements of certified reference materials from New Brunswick Program Office (NBL PO) CRM 136a and CRM 137. The MC-ICP-MS/MS performance of repeated measurement of CRM 136a (n = 20) resulted in mean values of 240 Pu/ 239 Pu = 0.1448 ± 0.0006, 241 Pu/ 239 Pu = 0.00371 ± 0.00006, and 242 Pu/ 239 Pu = 0.00682 ± 0.00006 (k = 2). The CRM 137 (n = 20), analyzed during the same analytical sessions, produced mean values for 240 Pu/ 239 Pu = 0.2414 ± 0.0006, 241 Pu/ 239 Pu = 0.00464 ± 0.00007, and 242 Pu/ 239 Pu = 0.0157 ± 0.0001 (k = 2). These results closely align with the certificate values for CRM 136a and CRM 137 and are within the k = 2 envelopes defined by the long-term performance of the traditional MC-ICP-MS approach (Neptune Plus). Examination of the performance of the various Pu isotope ratios as a function of total Pu content revealed accurate results (<3% relative difference, or RD) above ∼50 fg total Pu. The results presented here demonstrate the capability of the MC-ICP-MS/MS making accurate and precise low level Pu isotopic measurements. While the intent of this work was not to investigate the functionality of the collision cell, the pre-mass filter was employed. Future studies are warranted to investigate the entire capability of the MC-ICP-MS/MS collision cell and pre-cell mass filter optimization for performing low level Pu isotope measurements, even in mixed matrix samples.

CRM↗

Preparation of 241 Am/ 243 Am gravimetric mixtures and development of Am isotopic and assay measurement techniques using thermal ionization mass spectrometry

Three gravimetric mixtures with 241 Am/ 243 Am isotope ratios at nominally 1:1, 20:1, and 200:1 were prepared for calibration of the thermal ionization mass spectrometer instruments used for americium isotopic and assay measurements by isotope dilution mass spectrometry. The total evaporation analytical technique was developed for high-accuracy and precision measurements of Am isotopic ratios. The technique was also applied to Am assay measurements using isotope dilution mass spectrometry. The Am isotope ratio and assay measurement techniques were utilized to characterize batches of americium oxide separated from plutonium materials in storage at Los Alamos National Laboratory in support of commercial use of 241 AmO 2 .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Real-Time Screening for Uranium Enrichment by Paper Spray Ionization Mass Spectrometry for Field Applications

A rapid isotope ratio screening technique for uranium enrichment is demonstrated by utilizing paper spray ionization (PSI) high-resolution mass spectrometry (HRMS). Measurements were conducted using an ambient ionization mass spectrometer coupled to a custom-made JEOL PSI attachment apparatus, with de minimus sample preparation requirements. The current method detection limit for individual isotopes (e.g., 235 U and 238 U) is approximately 50 pg, with subsequent optimization expected to further improve U isotopic sensitivity. The PSI analytical method described herein can support rapid analysis (both in-field and in-lab screening) of isotopes-of-interest, as demonstrated by empirical differentiation of depleted uranium (DU) and low enriched uranium (LEU) analytical aliquots. Furthermore, this analytical workflow holds promise for applications in nuclear forensics, international nuclear safeguards, and nonproliferation missions.

Anions↗

A new highly enriched 233 U reference material for improved simultaneous determination of uranium amount and isotope amount ratios in trace level samples

A highly-enriched 233 U reference material (>0.99987 n( 233 U)/n(U)) has been prepared and characterized for use as an isotope dilution mass spectrometry spike. An ion exchange separation was performed on 1 g of high purity 233 U to further reduce trace amounts of contaminant Pu in the material. The purified 233 U was then prepared as a master solution which was analyzed for molality of uranium by modified Davies and Gray titration. A portion of the master solution was quantitatively diluted and dispensed for reference material units. Selected units were analyzed for verification of uranium amount and to characterize uranium isotope amount ratios by multi-collector inductively couple plasma mass spectrometry. Furthermore, modelling of spike-corrected isotopic data show that the new spike will enable simultaneous measurements of uranium amount and isotope amount ratios with resulting uncertainties that are substantially less sensitive to over spiking than widely used 233 U certified reference materials.

233U↗

Resolving Severe Elemental Isobaric Interferences with a Combined Atomic and Molecular Ionization Source - Orbitrap Mass Spectrometry Approach: The 87Sr and 87Rb Geochronology Pair

Many fields of basic and applied sciences, including geochronology, astronomy, metabolism, nutrition and forensics rely on the ability of mass spectrometry to make isotope ratio measurements with a high degree of certainty. The inability to resolve difficult isobaric interferences still plagues certain measurements of this type. A combined atomic and molecular (CAM) ionization source has been interfaced to a high-field Orbitrap mass spectrometer in an effort to alleviate severe atomic, isobaric interferences. Specifically, this work examines the geochronological-significant 87Sr and 87Rb isotope pair. The mass difference between 87Sr and 87Rb is ~0.3 mDa, requiring a minimum resolving power (R = m/?m) of ~290,000, a value ~30X higher than available with conventional (sector-field) elemental mass spectrometers. Under ultra-high resolution conditions, Sr isotope ratio accuracy and precision were evaluated using NIST Sr SRM 987, yielding precision values of <0.1% relative standard deviation (RSD) for the major isotopes and a calculated LOD of 2 pg mL-1, equivalent to 120 fg Sr for a 60 µL injection. In addition to manipulating the signal transient length, which controls the Orbitrap resolving power, the total number of ions in the electrostatic trap and the relative ion populations (i.e. the 87Sr/87Rb concentration ratio), were found to be influential towards resolving the isobaric species. Ultimately, the 87Sr and 87Rb isotopes were baseline resolved with a calculated mass resolution of >1.7 M. At equal 87Sr and 87Rb intensities, the 87Sr/86Sr was measured as 0.71294 (an error of 0.37%) with a precision of 0.097 %RSD, clearly reflecting the alleviation of the isobaric interference.

Hoegg, Edward D.↗

Analysis of an irradiated uranium sample for source attribution without chemical separation using microplasma ionization and ultrahigh resolution mass spectrometry

The use of element isotope ratios has great potential in not only determining the reactor type used to produce plutonium (Pu) but also in determining the burnup and the time since irradiation. While a powerful nuclear forensic technique, determining element isotope ratios is complicated by severe isobaric interferences when performed on typical inductively coupled plasma mass spectrometers. Such analyses require extensive chemical separations prior to analysis to alleviate the inter-elemental isobars. Ultrahigh mass resolution spectrometry provides a potential alternative, greatly reducing the complexity of sample preparation and turnaround times for these critical measurements. To demonstrate the power of the approach, a sample of irradiated, depleted uranium was analyzed with the liquid sampling—atmospheric pressure glow discharge ion source coupled to an Orbitrap mass spectrometer. The Orbitrap is augmented with an external data acquisition system, Spectroswiss’s FTMS-Booster X2T, allowing collection of extended ion transients, providing higher mass resolution. In using this approach, the 150 Sm/ 149 Sm and 152 Sm/ 149 Sm isotope ratios were found to be within 20% of predicted values without any chemical separations and without mass bias corrections. In addition, the 240 Pu/ 239 Pu isotope ratio was determined, free from the 238 UH + interferences common to the ICP-MS platforms, while at the same time allowing for the determination of U isotopic signatures. While these demonstrative results are from a single sample, the advantages of the microplasma/ultrahigh mass resolution approach to intra-element isotope ratio determinations are clear.

Fuel burnup↗