Search NASA⌕ Search

SEARCH · Search NASA

Results for “Microplasma”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Electron heating mode transition induced by ultra-high frequency in atmospheric microplasmas for biomedical applications

The electron heating mode transition induced by ultra-high frequency in atmospheric-pressure microplasmas was investigated using particle-in-cell simulation with a Monte Carlo collision. Interestingly, this discharge mode transition is accompanied by non-monotonic evolution of electron kinetics such as effective electron temperature, plasma density, and electron energy on the electrode. In this study, the highest flux of energetic electrons ({epsilon} > 4 eV) usable for tailoring the surface chemistry in atmospheric microplasmas is obtained at the specific frequency (400 MHz), where an optimal trade-off is established between the amplitude of sheath oscillations and the power coupled to electrons for sub-millimeter dimensions (200 {mu}m).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Analysis of cathode geometry to minimize cathode erosion in direct current microplasma jet

Microplasma jets are now widely used for deposition, etching, and materials processing. The present study focuses on the investigation of the influence of cathode geometry on deposition quality, for microplasma jet deposition systems in low vacuum. The interest here is understanding the influence of hydrogen on sputtering and/or evaporation of the electrodes. Samples obtained with two cathode geometries with tapered and rectangular cross-sections have been investigated experimentally by scanning electron microscopy and energy dispersion X-ray spectroscopy. Samples obtained with a tapered-geometry cathode present heavy contamination, demonstrating cathode erosion, while samples obtained with a rectangular-cross-section cathode are free from contamination. These experimental characteristics were explained by modelling results showing a larger radial component of the electric field at the cathode inner wall of the tapered cathode. As a result, ion acceleration is larger, explaining the observed cathode erosion in this case. Results from the present investigation also show that the ratio of radial to axial field components is larger for the rectangular geometry case, thus, qualitatively explaining the presence of micro-hollow cathode discharge over a wide range of currents observed in this case. In the light of the above findings, the rectangular cathode geometry is considered to be more effective to achieve cleaner deposition.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Cathode fall model and current-voltage characteristics of field emission driven direct current microplasmas

The post-breakdown characteristics of field emission driven microplasma are studied theoretically and numerically. A cathode fall model assuming a linearly varying electric field is used to obtain equations governing the operation of steady state field emission driven microplasmas. The results obtained from the model by solving these equations are compared with particle-in-cell with Monte Carlo collisions simulation results for parameters including the plasma potential, cathode fall thickness, ion number density in the cathode fall, and current density vs voltage curves. The model shows good overall agreement with the simulations but results in slightly overpredicted values for the plasma potential and the cathode fall thickness attributed to the assumed electric field profile. The current density vs voltage curves obtained show an arc region characterized by negative slope as well as an abnormal glow discharge characterized by a positive slope in gaps as small as 10 μm operating at atmospheric pressure. The model also retrieves the traditional macroscale current vs voltage theory in the absence of field emission.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of a chip-based ingroove microplasma source: Design, characterization, and diagnostics

A chip-based ingroove microplasma source was designed for molecular emission spectrometry by using a space-confined direct current duct in air. The voltage-current characteristics of different size generators, emission spectroscopy of argon were discussed, respectively. It is found that the emission intensity of excited Ar and N{sub 2} approaches its maximum near the cathode, while OH and O peaks most likely appear close to the anode. The electron density, electronic excitation temperature, rotational temperature, and vibrational temperature of the argon plasma were also calculated. More importantly, the chip-based ingroove microplasma shows much better stability compared with its counterparts.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enhancing the stability of microplasma device utilizing diamond coated carbon nanotubes as cathode materials

This paper reports the enhanced stability of a microplasma device by using hybrid-granular-structured diamond (HiD) film coated carbon nanotubes (CNTs) as cathode, which overcomes the drawback of short life time in the CNTs-based one. The microplasma device can be operated more than 210 min without showing any sign of degradation, whereas the CNTs-based one can last only 50 min. Besides the high robustness against the Ar-ion bombardment, the HiD/CNTs material also possesses superior electron field emission properties with low turn-on field of 3.2 V/μm, which is considered as the prime factor for the improved plasma illumination performance of the devices.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Obtaining composite Zr-Al-O coating on the surface of zirconium by microplasma oxidation

The paper describes the application of the microplasma oxidation for production of Zr-Al-O composition on the surface of zirconium. Certification of a new-type power supply for depositing oxide ceramic coatings by microplasma oxidation was also carried out. The growth rate of Zr-Al-O coating amounted around 0.2 nm/s, which around 10 times exceeds that for depositing similar coatings using the similar equipment. We have studied the change of surface morphology and the chemical composition of the formed ceramic coating by means of EVO 50 scanning electron microscope and X-ray spectral analysis.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Use of nonlocal helium microplasma for gas impurities detection by the collisional electron spectroscopy method

The collisional electron spectroscopy (CES) method, which lays the ground for a new field for analytical detection of gas impurities at high pressures, has been verified. The CES method enables the identification of gas impurities in the collisional mode of electron movement, where the advantages of nonlocal formation of the electron energy distribution function (EEDF) are fulfilled. Important features of dc negative glow microplasma and probe method for plasma diagnostics are applied. A new microplasma gas analyzer design is proposed. Admixtures of 0.2% Ar, 0.6% Kr, 0.1% N{sub 2}, and 0.05% CO{sub 2} are used as examples of atomic and molecular impurities to prove the possibility for detecting and identifying their presence in high pressure He plasma (50–250 Torr). The identification of the particles under analysis is made from the measurements of the high energy part of the EEDF, where maxima appear, resulting from the characteristic electrons released in Penning reactions of He metastable atoms with impurity particles. Considerable progress in the development of a novel miniature gas analyzer for chemical sensing in gas phase environments has been made.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electron and ion kinetics in three-dimensional confined microwave-induced microplasmas at low gas pressures

The effects of the gas pressure (p{sub g}), microcavity height (t), Au vapor addition, and microwave frequency on the properties of three-dimensional confined microwave-induced microplasmas were discussed in light of simulation results of a glow microdischarge in a three-dimensional microcavity (diameter d{sub h} = 1000 μm) driven at constant voltage loading on the drive electrode (V{sub rf}) of 180 V. The simulation was performed using the PIC/MCC method, whose results were experimentally verified. In all the cases we investigated in this study, the microplasmas were in the γ-mode. When p{sub g} increased, the maximum electron (n{sub e}) or ion density (n{sub Ar+}) distributions turned narrow and close to the discharge gap due to the decrease in the mean free path of the secondary electron emission (SEE) electrons (λ{sub SEE-e}). The peak n{sub e} and n{sub Ar+} were not a monotonic function of p{sub g}, resulting from the two conflicting effects of p{sub g} on n{sub e} and n{sub Ar+}. The impact of ions on the electrode was enhanced when p{sub g} increased. This was determined after comparing the results of ion energy distribution function (IEDFs) at various p{sub g}. The effects of t on the peaks and distributions of n{sub e} and n{sub Ar+} were negligible in the range of t from 1.0 to 3.0 mm. The minimum t of 0.6 mm for a steady glow discharge was predicted for p{sub g} of 800 Pa and V{sub rf} of 180 V. The Au vapor addition increased the peaks of n{sub e} and n{sub Ar+}, due to the lower ionization voltage of Au atom. The acceleration of ions in the sheaths was intensified with the addition of Au vapor because of the increased potential difference in the sheath at the drive electrode.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Investigation of the significance of excited species in wave-heated dense non-ideal microplasmas using particle-in-cell Monte Carlo-collision modeling

A computational model for the interaction of a high-pressure microplasma with an electromagnetic wave is presented. A one-dimensional particle-in-cell Monte Carlo collision model is used to investigate the plasma non-ideality effects in a second-stage laser-heated xenon plasma with a comprehensive chemistry mechanism, including excited species. A xenon microplasma at a temperature of 300 K and pressure of 10 bar becomes non-ideal after the laser heating stage with lower ionization and electronic excitation barriers, which makes the presence of excited species important to the plasma generation process. For these conditions, two-step ionization via excited species becomes a major contributor to plasma ionization. We find that full ionization of the plasma is obtained in ~2 ps when excited species are included in the chemistry model, as opposed to ~2.5 ps for a chemistry mechanism that does not consider their effect. With excited species, the ionization mode transitions from direct ionization via electron-neutral collisions to direct and stepwise ionization as the plasma generation progresses.

36 MATERIALS SCIENCE↗

Weak chaos and the 'melting transition' in a confined microplasma system

We present results demonstrating the occurrence of changes in the collective dynamics of a Hamiltonian system which describes a confined microplasma characterized by long-range Coulomb interactions. In its lower energy regime, we first detect macroscopically the transition from a 'crystallinelike' to a 'liquidlike' behavior, which we call the 'melting transition'. We then proceed to study this transition using a microscopic chaos indicator called the smaller alignment index (SALI), which utilizes two deviation vectors in the tangent dynamics of the flow and is nearly constant for ordered (quasiperiodic) orbits, while it decays exponentially to zero for chaotic orbits as exp[-(lambda{sub 1}-lambda{sub 2})t], where lambda{sub 1}>lambda{sub 2}>0 are the two largest Lyapunov exponents. During the melting phase, SALI exhibits a peculiar stairlike decay to zero, reminiscent of 'sticky' orbits of Hamiltonian systems near the boundaries of resonance islands. This alerts us to the importance of the DELTAlambda=lambda{sub 1}-lambda{sub 2} variations in that regime and helps us identify the energy range over which 'melting' occurs as a multistage diffusion process through weakly chaotic layers in the phase space of the microplasma. Additional evidence supporting further the above findings is given by examining the GALI{sub k} indices, which generalize SALI (=GALI{sub 2}) to the case of k>2 deviation vectors and depend on the complete spectrum of Lyapunov exponents of the tangent flow about the reference orbit.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fundamental Scaling of Microplasmas and Tunable UV Light Generation.

The temporal evolution of spectral lines from microplasma devices (MD) was studied, including impurity transitions. Long-wavelength emission diminishes more rapidly than deep UV with decreasing pulse width and RF operation. Thus, switching from DC to short pulsed or RF operation, UV emissions can be suppressed, allowing for real-time tuning of the ionization energy of a microplasma photo-ionization source, which is useful for chemical and atomic physics. Scaling allows MD to operate near atmospheric pressure where excimer states are efficiently created and emit down to 65 nm; laser emissions fall off below 200 nm, making MD light sources attractive for deep UV use. A first fully-kinetic three-dimensional model was developed that explicitly calculates electron-energy distribution function. This, and non-continuum effects, were studied with the model and how they are impacted by geometry and transient or DC operation. Finally, a global non-dimensional model was developed to help explain general trends MD physics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Collaborative Research: Atmospheric Pressure Microplasma Chemistry-Photon Synergies Final Report

Combining the effects of low temperature, atmospheric pressure microplasmas and microplasma photon sources shows greatly expanded range of applications of each of them. The plasma sources create active chemical species and these can be activated further by addition of photons and associated photochemistry. There are many ways to combine the effects of plasma chemistry and photochemistry, especially if there are multiple phases present. The project combines construction of appropriate test experimental systems, various spectroscopic diagnostics and mathematical modeling.

47 OTHER INSTRUMENTATION↗

One-step atmospheric microplasma synthesis of an NMC-type lithium-ion battery cathode

The manufacture of battery cathode materials is the most energy-intensive step in the production of commercial lithium-ion batteries; specifically, the synthesis of the widely used transition metal oxide cathodes can require tens of hours at temperatures exceeding 700 °C. Attempts to limit the reaction time and energy required to form crystalline cathode materials often still include a heating or calcination step. This communication aims to highlight a nascent yet novel synthesis route: a one-step atmospheric microplasma process for synthesizing cathode particles in less than one second. The hollow-tube reactor employed produces crystalline particles measuring 0.1–3 μm in diameter, displays narrow XRD peaks corresponding to the 003, 104, and 101 planes, and exhibits anodic redox behavior at 3.75 V vs. lithium—characteristic of transition-metal oxide cathode materials—all without requiring an additional calcination step.

25 ENERGY STORAGE↗

Metastable argon dynamics in a pulsed microplasma at 43 GHz

Short pulses of millimeter wave (MMW) radiation at 43 GHz create microplasma within a photonic crystal for pressures from 40 to 600 Torr (1.3 × 10 3 –8.0 × 10 4 Pa). Gas breakdown occurs within a photonic crystal, which acts as an electromagnetic resonator to create a strong initial electric field. The time response of the argon metastable density is experimentally determined during the pulse and in the afterglow using laser absorption. The metastable density overshoots the steady-state condition at the beginning of the pulse and during the afterglow. Modeling is presented to understand these observations. The overproduction of argon 1s5 at the beginning of each pulse is due to a concurrent overshoot in the MMW electric field within the photonic crystal. This field overheats the plasma electrons and enhances the production of excited states. The burst of argon metastables observed in the afterglow is due to the pooled energy of the plasma stored in electrons, ions, and excited states of argon. As a result, understanding metastable production is an important intermediate step to ionization and is also critical in the study of diode-pumped rare gas lasers.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ion Number Density Quantification Utilizing Pulsing Frequency in Negative Differential Resistance (NDR) Regime of Microplasma Operation

A mathematical model is presented for quantifying the ion number density over a range of discharge current in microplasma discharges. The ion number density is determined from measured discharge voltage, current, pulsing frequency, and trace impurity that is injected into the system deliberately. Experiments are conducted in pure helium with nitrogen being introduced as the trace species. The ion number density is estimated over a range of discharge current and is compared with multidimensional simulation results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Preliminary Figures of Merit for Isotope Ratio Measurements: The Liquid Sampling-Atmospheric Pressure Glow Discharge Microplasma Ionization Source Coupled to an Orbitrap Mass Analyzer

ABSTRACT In order to meet a growing need for fieldable mass spectrometer systems for precise elemental and isotopic analyses, the liquid sampling-atmospheric pressure glow discharge (LS-APGD) has a number of very promising characteristics. One key set of attributes that await validation deals with the performance characteristics relative to isotope ratio precision and accuracy. Due to its availability and prior experience with this research team, the initial evaluation of isotope ratio (IR) performance was performed on a Thermo Scientific Exactive Orbitrap instrument. While the mass accuracy and resolution performance for orbitrap analyzers are very well documented, no detailed evaluations of the IR performance have been published. Efforts described here involve two variables: the inherent IR precision and accuracy delivered by the LSAPGD microplasma and the inherent IR measurement qualities of orbitrap analyzers. Important to the IR performance, the various operating parameters of the orbitrap sampling interface, HCD dissociation stage, and ion injection/data acquisition have been evaluated. The IR performance for a range of other elements, including natural, depleted, and enriched uranium isotopes was determined. In all cases the precision and accuracy are degraded when measuring low abundance (<0.1% isotope fractions). In the best case, IR precision on the order of 0.1 %RSD can be achieved, with values of 1-3 %RSD observed for low-abundance species. The results suggest that the LSAPGD is a very good candidate for field deployable MS analysis and that the high resolving powers of the orbitrap may be complemented with a here-to-fore unknown capacity to deliver high-precision isotope ratios.

Environmental Molecular Sciences Laboratory↗

Rapid Determination of Uranium Isotopic Abundance from Cotton Swipes: Direct Extraction via a Planar Surface Reader and Coupling to a Microplasma Ionization Source

The collection of solid particulates and liquids from surfaces by the use of cloth swipes is fairly ubiquitous. In such methods, there is a continuous concern regarding the ability to locate and quantitatively sample the analyte species from the material. In this effort, we demonstrate the initial coupling of an Advion Plate Express plate reader to a liquid sampling–atmospheric pressure glow discharge (LS-APGD) microplasma ionization source with an Orbitrap mass spectrometer to perform uranium isotopic analyses of solution residues on cotton swipes. The Plate Express employs a sampling probe head to engage and seal against the swipe surface. Subsequentially, the analyte residues are desorbed and transported within a 2% HNO 3 electrolyte flow to the ionization source. Quantitative recoveries were observed following a single 30 s extraction step, with the absolute mass sampled per extraction being ~100 ng. While the intrasample variability in the analytical responses for triplicate sampling of the same swipe yield ~30% RSD, this lack of precision is offset by the ability to determine isotope ratios for enriched uranium specimens with a precision of better than 10% RSD. Pooled, intersample precision ( n = 9) was found to be <5%RSD across the various sample compositions. Finally, 235 U/ 238 U determinations (ranging from 0.053 to 1.806) were accurate with errors of <10%, absolute. The 234 U- and 236 U-inclusive ratios were determined with similar accuracy in enriched samples. While the driving force for the effort is in the realm of nuclear nonproliferation efforts, the ubiquitous use of cloth swipes across many application areas could benefit from this convenient approach, including the use of versatile, reduced-format mass spectrometer systems.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Single-Particle Isotopic Analysis Using the Liquid Sampling-Atmospheric Pressure Glow Discharge Microplasma Coupled to an Orbitrap Mass Spectrometer

Isotope ratio (IR) determinations on individual particles can provide valuable information relative to the sample, including processing and dating, which could be valuable to geological and nuclear material analysis communities. In comparison to “bulk” measurements, in which all particle information is lost and homogenized within a sample, “particle” measurements allow for fingerprinting and can provide unique insights related to the sample’s nano- and micro- compositions. Furthermore, the complex nature of particles, with potential isobaric interferences from either the matrix or other elements within the same particle, poses a significant analytical challenge for conventional mass spectrometry platforms employed for elemental analysis due to their limited mass resolution. Presented here is the first demonstration of an ultrahigh resolution method for single particle (SP) isotopic analysis using the liquid sampling-atmospheric pressure glow discharge (LS-APGD) microplasma ionization source coupled to an Orbitrap mass spectrometer and FTMS Booster X2T acquisition/processing system. For proof of concept, well-characterized CeO 2 microparticles with a nominal diameter of 1.0 μm were analyzed at a mass resolution of ∼330,000. Important instrumental parameters were optimized to enable the detection of single particles. The 142 Ce/ 140 Ce ratio of individual particles and the population average were determined and compared to an SP inductively coupled plasma time-of-flight mass spectrometry (ICP-TOF-MS) analysis. The isotopic accuracy and precision were determined by two methods and found to be in good agreement with the SP-ICP-TOF-MS method, with the linear regression slope method providing a more accurate ratio, showing a ∼1.4% relative difference from the ratio determined from a particle digest. The encouraging performance of the method was further supported by a determined detection limit of 2.9 fg ( 142 Ce). The developed method is anticipated to overcome many of the challenges posed by isobaric interferences encountered in conventional mass spectrometry techniques when analyzing real-world samples for particle isotopic composition.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗