Search NASA⌕ Search

SEARCH · Search NASA

Results for “Muon Accelerator Program”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

61 records · Page 4

Status of ICARUS NUMI Interaction Cross-Section Analysis

The ICARUS experiment, utilizing Liquid Argon Time Projection Chamber (LAr TPC) technology, has been installed at Fermilab in Chicago, Illinois, following its initial operation in Italy and subsequent refurbishment at CERN. ICARUS completed commissioning in June 2022. Currently, the experiment is in the phase of analyzing data from its two runs of physics data acquisition and gearing up for the third run. While its primary objective is to function as the far detector of the Short Baseline Neutrino program (SBN), seeking sterile neutrino signatures, ICARUS also offers diverse physics capabilities, including searches beyond the standard model and measurements of cross-sections. In addition to being exposed to the common Booster Neutrino (BNB) beamline, ICARUS also receives off-axis neutrinos from the Main Injector (NuMI) beam. Due to the off-axis angle between NuMI and ICARUS, coupled with contributions from both pion and kaon decays to neutrino fluxes, interactions of NuMI neutrinos within ICARUS can be detected over a range of several GeV in energy. These interactions present opportunities for crucial cross-section measurements and model tests within an energy range that overlaps both the SBN oscillation search and a portion of the DUNE spectrum. This poster presentation will delve into our efforts to conduct a muon-neutrino cross-section measurement, where the signal is defined by events with no pions produced in the final state of the interaction, along with some preliminary muon-neutrino inclusive measurements. Additionally, it will provide updates on the current status and future plans, including reconstruction, selection, and analysis procedures.

43 PARTICLE ACCELERATORS↗

High-Field Magnets for Future Hadron Colliders

Recent strategy updates by the international particle physics community have confirmed strong interest in a next-generation energy frontier collider after completion of the High-Luminosity LHC program and construction of a e + e - Higgs factory. Both hadron and muon colliders provide a path toward the highest energies, and both require significant and sustained development to achieve technical readiness and optimize the design. For hadron colliders, the energy reach is determined by machine circumference and the strength of the guiding magnetic field. To achieve a collision energy of 100 TeV while limiting the circumference to 100 km, a dipole field of 16 T is required and is within the reach of niobium–tin magnets operating at 1.9 K. Magnets based on high-temperature superconductors may enable a range of alternatives, including a more compact footprint, a reduction of the cooling power, or a further increase of the collision energy to 150 TeV. The feasibility and cost of the magnet system will determine the possible options and optimal configurations. In this article, I review the historical milestones and recent progress in superconducting materials, design concepts, magnet fabrication, and test results and emphasize current developments that have the potential to address the most significant challenges and shape future directions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Development of a Beam Halo Monitor

Muons, Inc. proposed improved Residual-Gas luminescent Beam Profile Monitors for Intense Beams by adding novel features including a mirascope, a light collecting device devised in the 16th century by an inventor of the telescope. A modern mirascope consists of 2 paraboloids. Light generated by the beam is collected by the paraboloids and creates a beam image. By placing a lens near the image it is possible to collect almost 100% of the emitted light, up to ten times better than existing fluorescence profilometers. Intense (multi-MW) proton beams pose a challenge for beam profile measurements. Solid-based beam intercepting instrumentation produces unallowable levels of radiation at these high powers. An alternative is to use a zero-or-low mass device such as a residual-gas profile monitor, either through collection of ionization or fluorescence. Fluorescence has an intrinsic advantage over the usual collection of ionized electrons in that it is not affected by the strong and variable electric and magnetic fields created by the beam that can distort profiles and make calibration difficult. For this reason, we proposed the fluorescence technique using the mirascope and other methods to enhance light collection and versatility by modifying the residual gas and its spatial distribution. In Phase I, we designed a mirascope and its electronics for commissioning and beam tests in a proposed Phase II. The design was based on optical simulations done in Phase I, and a physics run plan was developed for optimizing and testing. The Phase II experimental site and program have been planned and our goal is to produce a universal low cost Mirascope Residual-Gas Luminescent Beam Profile Monitor that can replace all other profile monitors currently used in accelerators.

43 PARTICLE ACCELERATORS↗

Search for a Hidden Sector Scalar from Kaon Decay in the Dimuon Final State at ICARUS

We present a search for long-lived particles (LLPs), produced in kaon decays, that decay to two muons inside the ICARUS neutrino detector. This channel would be a signal of hidden sector models that can address outstanding issues in particle physics such as the strong CP problem and the microphysical origin of dark matter. The search is performed with data collected in the Neutrinos at the Main Injector (NuMI) beam at Fermilab corresponding to 2.41 × 10 20 protons-on-target. No new physics signal is observed, and we set world leading limits on heavy QCD axions, as well as for the Higgs portal scalar among dedicated searches. Limits are also presented in a model-independent way applicable to any new physics model predicting the process 𝐾 → 𝜋 + 𝑆⁡(→ 𝜇⁢𝜇), for a LLP 𝑆. This result is the first search for new physics performed with the ICARUS detector at Fermilab. It paves the way for the future program of LLP searches at ICARUS.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Background studies and normalization of signal events in the Mu2e experiment

The Mu2e experiment is currently being constructed at Fermilab to search for the neutrino-less conversion of negative muons into electrons in the field of an aluminum nucleus. The experiment aims at a sensitivity of four orders of magnitude higher than previous related experiments, which implies highly demanding accuracy requirements both in the design and during the operation. To achieve such a goal, two important tasks should be accomplished. First, it is essential to estimate precisely the particle yields and all the backgrounds that could mimic the monoenergetic conversion electron signal. Second, it is necessary to normalize the signal events accurately. The normalization of the signal events is planned to be done using a detector system made of an HPGe detector and a Lanthanum Bromide detector, which will measure the rate of muons stopped on the aluminum target by looking at the emitted characteristic X-and γ-rays of energies up to 1809 keV. Therefore, it is essential to evaluate the detector system's performance before the start of the actual experiment. In this study, the first task was addressed by an extensive campaign of Monte Carlo simulations to investigate the relevant parameters and their impact on the experiment's sensitivity. The second task was handled by taking advantage of the Helmholtz-Zentrum Dresden-Rossendorf (HZDR) pulsed Bremsstrahlung photon beam at the ELBE facility. The detector system was tested at the ELBE facility under timing and background conditions similar to the ones expected at the Mu2e experiment. The study presents and discusses the simulation results and the detector system testing campaign.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Workshop on a future muon program at FNAL

The Snowmass report on rare processes and precision measurements recommended Mu2e-II and a next generation muon facility at Fermilab (Advanced Muon Facility) as priorities for the frontier. The Workshop on a future muon program at FNAL was held in March 2023 to discuss design studies for Mu2e-II, organizing efforts for the next generation muon facility, and identify synergies with other efforts (e.g., muon collider). Topics included high-power targetry, status of R&D for Mu2e-II, development of compressor rings, FFA and concepts for muon experiments (conversion, decays, muonium and other opportunities) at AMF. This document summarizes the workshop discussions with a focus on future R&D tasks needed to realize these concepts.

43 PARTICLE ACCELERATORS↗

Identification and reconstruction of low-energy electrons in the ProtoDUNE-SP detector

Measurements of electrons from 𝜈𝑒 interactions are crucial for the Deep Underground Neutrino Experiment (DUNE) neutrino oscillation program, as well as searches for physics beyond the standard model, supernova neutrino detection, and solar neutrino measurements. This article describes the selection and reconstruction of low-energy (Michel) electrons in the ProtoDUNE-SP detector. ProtoDUNE-SP is one of the prototypes for the DUNE far detector, built and operated at CERN as a charged particle test beam experiment. A sample of low-energy electrons produced by the decay of cosmic muons is selected with a purity of 95%. This sample is used to calibrate the low-energy electron energy scale with two techniques. An electron energy calibration based on a cosmic ray muon sample uses calibration constants derived from measured and simulated cosmic ray muon events. Another calibration technique makes use of the theoretically well-understood Michel electron energy spectrum to convert reconstructed charge to electron energy. In addition, the effects of detector response to low-energy electron energy scale and its resolution including readout electronics threshold effects are quantified. Finally, the relation between the theoretical and reconstructed low-energy electron energy spectra is derived, and the energy resolution is characterized. The low-energy electron selection presented here accounts for about 75% of the total electron deposited energy. After the addition of lost energy using a Monte Carlo simulation, the energy resolution improves from about 40% to 25% at 50 MeV. These results are used to validate the expected capabilities of the DUNE far detector to reconstruct low-energy electrons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗