Search NASA⌕ Search

SEARCH · Search NASA

Results for “NEUTRON COUNTER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Ground calibration and in-flight commissioning of the Gamma-Ray and Neutron Spectrometer (GRNS) for NASA’s Psyche mission

NASA's Psyche spacecraft is currently enroute to the asteroid 16 Psyche, where it will perform an orbital investigation focused on determining the nature of the asteroid. A key part of this investigation is measurements of elemental composition to determine if the asteroid is rich in iron-nickel metal. To that end, the Psyche spacecraft payload includes a Gamma-Ray and Neutron Spectrometer (GRNS). GRNS is composed of two subsystems; a Gamma-Ray Spectrometer (GRS) with a high-purity germanium γ-ray sensor surrounded by a borated plastic scintillator Anti-Coincidence Shield (ACS), and a Neutron Spectrometer (NS) with three 3 He-filled gas proportional counters that are sensitive to different neutron energy regimes. We describe results from the pre-launch calibration campaign, along with early in-flight results from post-launch instrument commissioning. The information detailed here is focused on providing future users of GRNS data with the information needed to properly interpret the observations from the instrument.

Peplowski, Patrick N. [Johns Hopkins Univ., Baltim↗

Nuclear Science Symposium, 27th, and Symposium on Nuclear Power Systems, 12th, Orlando, Fla., November 5-7, 1980, Proceedings

Advances in instrumentation for use in nuclear-science studies are described. Consideration is given to medical instrumentation, computerized fluoroscopy, environmental instrumentation, data acquisition techniques, semiconductor detectors, microchannel plates and photomultiplier tubes, reactor instrumentation, neutron detectors and proportional counters, and space instrumentation.

Martini, M.↗

Fast neutron background characterization of the future Ricochet experiment at the ILL research nuclear reactor

Abstract The future Ricochet experiment aims at searching for new physics in the electroweak sector by providing a high precision measurement of the Coherent Elastic Neutrino-Nucleus Scattering (CENNS) process down to the sub-100 eV nuclear recoil energy range. The experiment will deploy a kg-scale low-energy-threshold detector array combining Ge and Zn target crystals 8.8 m away from the 58 MW research nuclear reactor core of the Institut Laue Langevin (ILL) in Grenoble, France. Currently, the Ricochet Collaboration is characterizing the backgrounds at its future experimental site in order to optimize the experiment’s shielding design. The most threatening background component, which cannot be actively rejected by particle identification, consists of keV-scale neutron-induced nuclear recoils. These initial fast neutrons are generated by the reactor core and surrounding experiments (reactogenics), and by the cosmic rays producing primary neutrons and muon-induced neutrons in the surrounding materials. In this paper, we present the Ricochet neutron background characterization using $$^3$$ 3 He proportional counters which exhibit a high sensitivity to thermal, epithermal and fast neutrons. We compare these measurements to the Ricochet Geant4 simulations to validate our reactogenic and cosmogenic neutron background estimations. Eventually, we present our estimated neutron background for the future Ricochet experiment and the resulting CENNS detection significance. Our results show that depending on the effectiveness of the muon veto, we expect a total nuclear recoil background rate between 44 ± 3 and 9 ± 2 events/day/kg in the CENNS region of interest, i.e. between 50 eV and 1 keV. We therefore found that the Ricochet experiment should reach a statistical significance of 4.6 to 13.6 $$\sigma $$ σ for the detection of CENNS after one reactor cycle, when only the limiting neutron background is considered.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Novel Perovskite Semiconductors for the Detection of Special Nuclear Material

Special nuclear material detection using portable, highly efficient detectors is of paramount importance to national security and environmental monitoring. Current neutron detectors, including gas proportional counters and scintillators, are not suitable for discrete or portable monitoring due to size, weight, and power limitations. For example, 3 He gas proportional detectors have significant drawbacks, including long absorption lengths, high voltage requirements, and dependence on the availability of 3 He. The goal of this project is to synthesize a novel, boron-based perovskite semiconductor crystals to create a more efficient and more portable neutron detector. This innovative material will lead to a significant decrease in power and size requirements with higher operating temperatures than other traditional solid-state detectors. Directly incorporating 10 B eliminates the need for a conversion layer and leads to high neutron absorption coefficients. In this seedling project, we used inverse temperature crystallization with boron precursors to create CH 3 NH 3 PbI 3-x (BF 4 ) x . The crystals were analyzed with X-ray diffraction, but the results were inconclusive. Future work will focus on tailoring the solution growth and selecting appropriate solvents and precursors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Resource Prospector Neutron Spectrometer System: RP's Bloodhound

The primary goal of the Resource Prospector Neutron Spectrometer System (NSS) is to locate and characterize hydrogen-bearing volatile deposits, especially subsurface ice, that may exist at the lunar poles. A key objective is to detect water-equivalent hydrogen concentrations of 0.5 wt% or greater while on a moving rover. A second objective is to determine approximate burial depth of enhanced hydrogen-bearing materials up to 1 meter below otherwise dry regolith. The instrument will be carried aboard a landed mobility system at the lunar poles. The instrument operates by measuring the changes in the leakage flux of low energy neutrons out of the regolith. These neutrons are produced by galactic cosmic rays, which are so energetic that they shatter the nuclei in surface materials. The neutrons interact with other nuclei and lose energy, becoming thermalized in the process. Hydrogen is most efficient at thermalizing neutrons owing to protons' similar mass - statistically, neutrons lose half their energy per collision with protons. With hydrogen in the soil, leakage fluxes of neutrons in the 0.5 eV to 500 keV energy range are reduced. A concentration of only1-2 wt% water-equivalent hydrogen results in a decrease in epithermal leakage flux of a factor of two. The leakage flux of thermal neutrons, from 0 to 0.5 eV in energy, can either increase or decrease depending on the hydrogen abundance and stratigraphy. As with the highly successful Lunar Prospector Neutron Spectrometer, the RP NSS detects both thermal and epithermal neutrons by using two helium-3 gas proportional counters, one covered by cadmium and the other uncovered. The former detects only epithermal neutrons with energies above approximately 0.5 eV, the latter detects both thermal (less than 0.5 eV) and epithermal energies (greater than 0.5 eV). When a neutron enters the detector tube and interacts with a helium-3 nucleus, the resulting reaction produces an energetic proton and triton that ionize the gas. The resulting electrons are accelerated toward a high-voltage anode and cascade, amplifying the net charge, which is collected at the anode. The number of electrons produced is proportional to the energy that the triton and proton deposit in the gas. A charge sensitive pre-amplifier converts the total charge to a step voltage output. A shaper amplifier then shapes this step into a uni-polar waveform with peaking time appropriate for the detection depending on the event rate. The integrated shaped waveform, representing the deposited triton/proton energy, is then measured. A histogram, or pulse height analysis, is performed to record the main capture peak and wall effect pulses. A threshold for detection is also required to limit the low amplitude counting rate such as noise floor. The system electronics consists of 2 modules - the Sensor Module (SM) front-end and the Data Processing Module (DPM) back-end circuits. SM is designed as a light-weight and low power front-end housing the two helium-3 proportional counter detectors, preamp and HVPS. It is mounted external to the rover body to detect the thermalized neutron flux with a minimum of host background. The DPM is located inside the rover; it digitizes the SM signals, performs pulse height analysis and accumulates the count rate for each spectral channel. The DPM controls high voltage and thresholding, and sends the science data to the host craft via an RS422 serial asynchronous protocol. The payload host provides all thermal management and control for the SM and DPM.

hydrogen-bearing volatile deposits↗

Time-of-flight experiments for nuclear structure and astrophysics

Neutron-rich isotopes are atomic nuclei with a large neutron excess compared to their stable counter parts. Their study provides essential information to understand the properties of the nuclear interaction, and to model nuclear processes in extreme astrophysical environments where neutron-rich isotopes drive the chains of nuclear reactions. Experimentally, these unstable isotopes are difficult to study because of their short half-lives and low production yields at particle accelerator laboratories. The TOF-Bρ technique is a mass measurement technique specialized for experiments with fast beams of short-lived radioactive isotopes. In this project we used the technique for two experiments performed at the National Superconducting Cyclotron Laboratory to measure new masses of isotopes in the region of 112 Mo and 46 S. The experiments at the NSCL were complemented by the development of new timing radiation detectors and experimental techniques to improve the performance and reach of mass measurements on neutron-rich isotopes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Science & Technology Review: Awards for Livermore Innovation

At Lawrence Livermore National Laboratory, we focus on science and technology research to ensure our nation’s security. We also apply that expertise to solve other important national problems in energy, bioscience, and the environment. Science & Technology Review (S&TR) is published eight times a year to communicate, to a broad audience, the Laboratory’s scientific and technological accomplishments in fulfilling its primary missions. The publication’s goal is to help readers understand these accomplishments and appreciate their value to the individual citizen, the nation, and the world. In 2021, Lawrence Livermore technologies received three R&D 100 awards, which honor the year’s top 100 innovations from around the world. The feature article beginning on p. 4 describes the Laboratory’s winners: the Multiplicity Counter for Thermal and Fast Neutrons, Flux, and the Optical Transconductance Varistor. The 2021 awards raised the Laboratory’s total R&D 100 awards to 173 since 1978. The R&D 100 logo is reprinted in this issue with permission from R&D World magazine.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Swift and NuSTAR Observations of GW170817: Detection of a Blue Kilonova

With the first direct detection of merging black holes in 2015, the era of gravitational wave (GW) astrophysics began. A complete picture of compact object mergers, however, requires the detection of an electromagnetic (EM) counterpart. We report ultraviolet (UV) and x-ray observations by Swift and the Nuclear Spectroscopic Telescope Array of the EM counter part of the binary neutron star merger GW170817.The bright, rapidly fading UV emission indicates a high mass (0.03 solar masses) wind-driven outflow with moderate electron fraction (Ye ≈ 0.27). Combined with the x-ray limits, we favor an observer viewing angle of ≈30° away from the orbital rotation axis, which avoids both obscuration from the heaviest elements in the orbital plane and a direct view of any ultra relativistic, highly collimated ejecta (a gamma-ray burst afterglow).

Evans, P. A.↗

Next-generation neutron detection using a 6 Li glass scintillator composite

Neutron detectors are crucial in fundamental science, nuclear security, safeguards, and civil applications. 3 He-filled gas proportional counters are the gold standard for thermal neutron detection, prized for their efficiency, neutron/gamma discrimination, and stability; however, the scarcity of 3 He has prompted the search for alternatives. Here, we introduce a neutron detector design based on a scintillating composite consisting of 6 Li glass scintillator particles dispersed in an organic matrix. A detector consisting of this scintillating composite, photomultiplier tubes (PMTs) for optical detection, and electronics for reading out the PMT signal in both pulse and current modes was prototyped and characterized using various neutron and gamma sources. The prototype achieves a measured intrinsic detection efficiency of 6.70 ± 0.01%, a die-away time of 10.3 ± 0.1 μs, a negligible gamma misidentification probability, and response linearity up to at least 3.7 × 10 6 incident neutrons/s established via a cross-calibration technique. This detector holds the potential to outperform traditional 3 He-gas-based neutron detection systems, offering a viable alternative amidst the ongoing 3 He shortage and promising advancements in neutron detection technology.

47 OTHER INSTRUMENTATION↗

Long-term Neutron Background Environment Measured by the Dynamic Albedo of Neutrons (DAN) Instrument onboard Mars Science Laboratory (MSL)

The Dynamic Albedo of Neutrons (DAN) instrument onboard Mars Science Laboratory (MSL) consists of a pulsed neutron generator (PNG) and the neutron detector/electronics (DE) module. There are two 3He-proportional counters used in the DE module. One counter is surrounded with a Cd shell enclosure and measures epi-thermal neutrons with >0.4 eV. The second detector does not have a Cd shell enclosure and measures both thermal and epi-thermal neutrons. The main scientific objectives of DAN are two-fold: (1) the primary objective is to measure the bulk hydrogen abundance (in forms of water or hydrated minerals) of the sub-surface and (2) the secondary objective is to measure the background neutron environment at the surface. DAN achieves the first objective by using a pulsed 14 MeV neutron source (ACTIVE mode). Emitted neutrons undergo a series of nuclear interactions with the regolith and lose energy. The DAN DE module then measures the time profile of the neutrons returned from the regolith. Even a small amount of hydrogen, as low as 0.1 weight % in the regolith, can effectively moderate the high energy neutrons [Mitrofanov, et al., ]. The less-moderated (or epi-thermal) neutrons arrive at the detector earlier than the more-moderated (or thermal) neutrons. The shape and magnitude of neutron time profile curves after pulses can be used to estimate the depth distribution of the hydrogen content. When no neutron pulse is used (PASSIVE mode) DAN measures the neutron background environment at the Mars surface. There are two sources of the background neutrons which DAN would measure: one is secondary neutrons generated by galactic cosmic ray (GCR) interactions with atmospheric and surface materials and the other is neutrons from the Multi-Mission Radioisotope Thermoelectric Generator (MMRTG) onboard MSL as a power source. The passive mode data for the first 1300 sols of the MSL mission are presented in this paper. A summary of the DAN surface operation is described by [Mitrofanov et al., 2012; Jun et al., 2013.

Tate, C.↗

A novel photomultiplier tube neutron time-of-flight detector

A traditional neutron time-of-flight (nTOF) detector used in inertial confinement fusion consists of a scintillator coupled with a photomultiplier tube (PMT). The instrument response function (IRF) of such a detector is dominated by the scintillator-light decay. At DT neutron yields larger than 1013 a novel detector consisting of a microchannel-plate photomultiplier tube in a housing without a scintillator (PMT nTOF) can be used to measure DT yield, ion temperature, and neutron velocity. Most of the neutron signal in PMT nTOF is produced from neutron interaction with a PMT window. The direct interaction of neutrons with MCP has negligible contribution. The elimination of the scintillator removes the scintillator decay from the instrument response function and makes the IRF of the PMT nTOF faster, which makes the ion temperature and neutron velocity measurements more accurate. Three PMT nTOFs were deployed on the OMEGA Laser System for the first time to diagnose inertial confinement fusion plasma. Here, the design details, characteristics, and calibration results of these detectors in DT implosions on OMEGA are presented. Recommendations on the use of different PMTs for specific applications are provided.

47 OTHER INSTRUMENTATION↗

Neutron-induced capture-to-fission cross section ratio measured at LANSCE

Capture-to-fission cross section ratios are used as an alternative to absolute cross section measurements. This is due to the simplification on the calculations and the reduction of the uncertainties with respect to an absolute measurement of the cross section by eliminating experimental complications like self-absorption, beam/target overlap and non-uniformities. Different capture-to-fission reactions have been measured through the years at the Los Alamos Neutron Science Center (LANSCE) at Los Alamos National Laboratory (LANL) using the Detector for Advanced Neutron Capture Experiments (DANCE) combined with different fission detectors. Some of these are a Parallel Plate Avalanche Counter (PPAC) to detect fission fragments (FF), and the NEUtron detector array at DANCE (NEUANCE) to detect fission neutrons. As DANCE detects the γ-rays produced in capture and fission reactions, the fission instrument placed inside the DANCE cavity is used to tag the fission γ-rays for background identification and subtraction. Some examples of capture-to-fission ratio measurements performed with DANCE in the last years are the 233 U, 235 U and 239 Pu. The measurement technique, the different setups, and other potential applications of the instruments will be explained.

Nuclear Criticality Safety Program (NCSP)↗

Characterizing Shielded Special Nuclear Material by Neutron Capture Gamma-Ray Multiplicity Counting

We present a new neutron multiplicity counting analysis and measurement method for neutron-shielded fissile material using neutron-capture gamma rays. Neutrons absorbed in shielding produce characteristic gamma rays that preserve the otherwise lost neutron multiplicity signature. Neutron multiplicity counting provides estimates of fission parameters, such as neutron leakage multiplication, spontaneous fissioner (e.g. Pu-240) mass, and (α,n) ratio. Standard neutron multiplicity counting can incorporate the new neutron-capture gamma-ray multiplicity counting technique to characterize previously degenerate or intractable source configurations by maximizing the multiplicity signature. The new method decouples neutron source-detector interferences, such as reflection and thermalization time in the detector, that could improve measurements of the mean neutron lifetime. We also develop a detector prototype for the multiplicity counting of neutron-capture gamma rays and present detector design considerations, such as detection material and shielding, to optimize the detection of the 2.2 MeV hydrogen capture gamma ray. We simulate the prototype neutron- capture gamma-ray multiplicity counter against the BeRP ball in polyethylene shells to inform future measurements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A fast-neutron spectrometer of advanced design

Fast neutron spectrometer combines helium filled proportional counters with solid-state detectors to achieve the properties of high efficiency, good resolution, rapid response, and effective gamma ray rejection.

Moler, R. B.↗