Search NASASearch

SEARCH · Search NASA

Results for “POROSITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Near Infrared In-situ Measurements for the Detection of Keyhole Porosity in Autogenous Ti-6AL-4V Welds

Certification of additive manufactured metal parts requires nondestructive evaluation (NDE) to ensure build quality. NDE can be performed during the build process or post build. For large parts with complex geometries, post build NDE can be challenging. In-situ NDE potentially provides a way to perform the inspection layer by layer. This work explores the use of a high speed near infrared (NIR) camera that is focused in-line with a laser to obtain high spatial and temporal resolution thermal imagery of the melt pool and associated cooling areas. The thermal data is obtained during a laser melting process using Ti-6AL-4V plate and of particular interest is the detection of keyhole porosity. Keyhole porosity can result from non-optimal build conditions, such as excessive laser power at a given laser scanning speed, that creates an entrapped bubble. The NIR measured melt pool and cooling areas are processed to detect keyhole porosity. The results are compared to X-ray CT results for validation.

additive manufacturing

Near Infrared In-situ Measurements for the Detection of Keyhole Porosity in Autogenous Ti-6AL-4V Welds

Certification of additive manufactured metal parts requires nondestructive evaluation (NDE) to ensure build quality. NDE can be performed during the build process or post build. For large parts with complex geometries, post build NDE can be challenging. In-situ NDE potentially provides a way to perform the inspection layer by layer. This work explores the use of a high speed near infrared (NIR) camera that is focused in-line with a laser to obtain high spatial and temporal resolution thermal imagery of the melt pool and associated cooling areas. The thermal data is obtained during a laser melting process using a Ti-6Al-4V plate and of particular interest is the detection of keyhole porosity. Keyhole porosity can result from non-optimal build conditions, such as excessive laser power at a given laser scanning speed, that creates an entrapped bubble. The NIR measured melt pool and cooling areas are processed to detect keyhole porosity. The results are compared to X-ray CT results for validation. Small keyhole pores buried deep were not detectable with this technique, however, some larger subsurface elongated pores along with some open surface pores did show some promise for detectability.

additive manufacturing

The Role of Bedrock Circulation Depth and Porosity in Mountain Streamflow Response to Prolonged Drought

Quantitative understanding is lacking on how the depth of active groundwater circulation in bedrock affects mountain streamflow response to a multi-year drought. We use an integrated hydrological model to explore the sensitivity of a variety of streamflow metrics to bedrock circulation depth and porosity under a plausible extreme drought scenario lasting up to 5 years. Endmember depth versus hydraulic conductivity relationships and porosity values for fractured crystalline rock are simulated. With drought, a deeper circulation system with higher drainable porosity more effectively buffers minimum flow and significantly limits perennial stream loss in comparison to a shallow circulation system. Streamflow buffering is accomplished through extensive groundwater storage loss. However, deeper circulation systems experience prolonged recovery from drought in comparison to storage-limited shallow systems. Research highlights the importance of characterizing the deeper bedrock hydrogeology in mountainous watersheds to better understand and predict drought impacts on stream ecosystem health and water resource sustainability.

54 ENVIRONMENTAL SCIENCES

Measurement of density and porosity of lunar rocks based on samples of Luna 16 automatic lunar station

Three fragments of holocrystalline igneous rocks of the gabbro type, weighing 30 to 50 mg each, were investigated. The density of the fragments was established with a mercury pycnometer and was found to be 3.05 to 3.12 g/cu cm, with a relative error not more than 2 percent. The porosity was found for the difference between the volumes determined with the mercury and with the gas techniques; for all three samples together it was 13 percent, and the error of determination was 70 percent owing to the small volumes. It can be anticipated that the porosity of the rock in bulk will be higher than the value obtained based on small fragments. The porosity of lunar rocks can markedly affect the isostatic distribution of rocks and must be taken into account when developing models of lunar structure.

Volynets, V. F.

Parametric performance of circumferentially grooved heat pipes with homogeneous and graded-porosity slab wicks at cryogenic temperatures

A recently developed, potentially high-performance nonarterial wick has been extensively tested. This slab wick has an axially varying porosity which can be tailored to match the local stress imposed on the wick. The purpose of the tests was to establish the usefulness of the graded-porosity slab wick at cryogenic temperatures between 110 K and 260 K, with methane and ethane as working fluids. For comparison, a homogeneous (i.e., uniform porosity) slab wick was also tested. The tests included: (1) maximum heat pipe performance as a function of fluid inventory, (2) maximum performance as a function of operating temperature, (3) maximum performance as a function of evaporator elevation, and (4) influence of slab wick orientation on performance. The experimental data was compared with theoretical predictions obtained with the computer program GRADE.

Groll, M.

Parametric performance of circumferentially grooved heat pipes with homogeneous and graded-porosity slab wicks at cryogenic temperatures

A recently developed, potentially high-performance nonarterial wick was extensively tested. This slab wick has an axially varying porosity which can be tailored to match the local stress imposed on the wick. The purpose of the tests was to establish the usefulness of the graded-porosity slab wick at cryogenic temperatures between 110 and 260 K, with methane and ethane as working fluids. For comparison, a homogeneous (i.e., uniform porosity) slab wick was also tested. The tests included: maximum heat pipe performance as a function of fluid inventory, maximum performance as a function of operating temperature, maximum performance as a function of evaporator elevation, and influence of slab wick orientation on performance. The experimental data were compared with theoretical predictions obtained with the GRADE computer program.

Groll, M.

Graded-porosity heat-pipe wicks

To maximize the capacity of a nonarterial heat pipe, a wick is considered whose porosity is allowed to vary axially along its length. At every axial location the porosity is set no lower than required to maintain the wick in a nearly saturated state under the maximum heat-transport rate. The result is a wick whose permeability is everywhere as high as possible. The differential equation that governs the optimum porosity variation is solved numerically between a condenser-end boundary condition that just prevents a liquid slug or puddle in the vapor spaces and an evaporator-end boundary condition that just prevents circumferential groove dry-up. Experimental performance measurements for an ammonia heat pipe are presented.

Eninger, J. E.

Effects of thermally induced porosity on an as-HIP powder metallurgy superalloy

The effect of thermally induced porosity on the mechanical properties of an as-hot-isostatically pressed and heat-treated pressing made from low carbon Astroloy is examined. Tensile, stress-rupture, creep, and low cycle fatigue tests were performed and the results were compared with industrial acceptance criteria. It is shown that the porous pressing has a porosity gradient from the rim to the bore with the bore having 1-1/2% greater porosity. Mechanical properties of the test ring below acceptance level are tensile reduction in area at room temperature and 538 C and time for 0.1% creep at 704 C. It is also found that the strength, ductility, and rupture life of the rim are slightly inferior to those of the rim of the sound pressings, while those of the bore are generally below the acceptable level. At strain ranges typical of commercial aircraft engines, the low cycle fatigue life of the rim of the porous pressings is slightly lower than that of the sound pressings.

Dreshfield, R. L.

Ultrasonic measurement of porosity in casts and welds

The development of a quantitative nondestructive method which involves ultrasonic attenuation measurements in frequency domain to determine volume fraction of porosity in aluminum cast is discussed. The aluminum alloy A357 casting samples were produced at the Ohio State University Foundry with controlled porosity contents ranging from 0% to 6%. A computer controlled system was used to direct ultrasonic beam to a test sample to different places to conduct ultrasonic attenuation measurements. The plot of attenuation coefficients as a function of frequency was then evaluated based on existing theories to determine volume fraction of porosity and pore size.

Adler, L.

Porosity determination of thermal barrier coatings

Coating porosity is believed to be a critical factor for the thermal conductivity of thermal barrier coatings (TBCs). A number of different techniques have been used to determine the porosities of thermal barrier coatings for diesel applications as part of a NASA/DOE sponsored study. A comparison is made between methods based on water immersion, optical microscopy, eddy current thickness measurements, and Archimedes principle for TBC porosity determination.

Van Roode, Mark

Review and statistical analysis of the ultrasonic velocity method for estimating the porosity fraction in polycrystalline materials

A review and statistical analysis of the ultrasonic velocity method for estimating the porosity fraction in polycrystalline materials is presented. Initially, a semi-empirical model is developed showing the origin of the linear relationship between ultrasonic velocity and porosity fraction. Then, from a compilation of data produced by many researchers, scatter plots of velocity versus percent porosity data are shown for Al2O3, MgO, porcelain-based ceramics, PZT, SiC, Si3N4, steel, tungsten, UO2,(U0.30Pu0.70)C, and YBa2Cu3O(7-x). Linear regression analysis produced predicted slope, intercept, correlation coefficient, level of significance, and confidence interval statistics for the data. Velocity values predicted from regression analysis for fully-dense materials are in good agreement with those calculated from elastic properties.

Roth, D. J.

CFD modeling of turbulent flows around the SSME main injector assembly using porosity formulation

Hot gas turbulent flow distribution around the main injector assembly of the Space Shuttle Main Engine (SSME) and liquid oxygen (LOX) flow distributions through the LOX posts have great effect on the combustion phenomenon inside the main combustion chamber. An advanced computational fluid dynamics (CFD) analysis will help to provide more accurate and efficient characterization of this type of flow field. In order to design a CFD model to be an effective engineering analysis tool with good computational turn-around time and still maintain good accuracy in describing the flow features, the concept of porosity is employed to describe the effects of blockage and drag force due to the presence of the LOX posts in the turbulent flow field around the main injector assembly of the SSME. A validated non-isotropic porosity model is developed and incorporated into an existing Navier-Stokes flow solver (FDNS). Volume and surface porosity parameters, which are based on the configurations of local LOX post clustering, are introduced into the governing equations.

Cheng, Gary C.

The effect of weld porosity on the cryogenic fatigue strength of ELI grade Ti-5Al-2.5Sn

The effect of weld porosity on the fatigue strength of ELI grade Ti-5Al-2.5Sn at cryogenic temperature was determined. A series of high cycle fatigue (HCF) and tensile tests were performed at -320 F on specimens made from welded sheets of the material. All specimens were tested with weld beads intact and some amount of weld offset. Specimens containing porosity and control specimens containing no porosity were tested. Results indicate that for the weld configuration tested, the fatigue life of the material is not affected by the presence of spherical embedded pores.

Rogers, P. R.

Thermal diffusivity measurements on composite porosity samples

A phase lag technique is used to make quantitative measurements of diffusivity in composite porosity samples. Changes in through-ply diffusivity in a graphite composite due to varying porosity levels are examined. The relationship between the amount of porosity and the change in diffusivity is analyzed using an electrical analog for modeling heat flow in the composite.

Zalameda, Joseph N.

Review and statistical analysis of the use of ultrasonic velocity for estimating the porosity fraction in polycrystalline materials

A review and statistical analysis of the ultrasonic velocity method for estimating the porosity fraction in polycrystalline materials is presented. Initially, a semiempirical model is developed showing the origin of the linear relationship between ultrasonic velocity and porosity fraction. Then, from a compilation of data produced by many researchers, scatter plots of velocity versus percent porosity data are shown for Al2O3, MgO, porcelain-based ceramics, PZT, SiC, Si3N4, steel, tungsten, UO2,(U0.30Pu0.70)C, and YBa2Cu3O(7-x). Linear regression analysis produces predicted slope, intercept, correlation coefficient, level of significance, and confidence interval statistics for the data. Velocity values predicted from regression analysis of fully-dense materials are in good agreement with those calculated from elastic properties.

Roth, D. J.

Assessment of passive porosity with free and fixed separation on a tangent ogive forebody

Subsonic wind tunnel tests were performed on solid and porous (22 percent) 5.0-caliber forebody models to assess the effect of free and fixed cross-flow separation on the effectiveness of passive porosity. The effectiveness of passive porosity to control the local pressure loading for forced cross-flow separation is found to be similar to that observed for the free cross-flow separation condition. It is also found that the effectiveness of passive porosity is significantly enhanced in the presence of large positive pressures on the porous surface.

Wood, Richard M.

Surface areas and porosities of ices used to simulate stratospheric clouds

Surface areas, bulk densities, and porosities of ices formed at 85 or 200 K are measured to study the morphology of the vapor-deposited ices that have been used to simulate ice clouds in the laboratory. Surface areas are measured from the Brunauer, Emmett, and Teller (BET) analysis of absorption isotherms obtained at 72.2 K. Bulk densities and porosities are determined photogrammetrically. Results show that water ice and HNO3-H2O ice films deposited from the vapor at temperatures below 200 K exhibit large BET surface areas and are highly porous. For the ices annealed at temperatures above 200 K, external surface areas calculated from the observed particle sizes agree reasonably well with the BET areas, which indicates that the annealed ices are composed of nonporous particles and that the porosity of these ices is due to interstices among the particles.

Keyser, Leon F.

Effective Thermal Conductivity of High Porosity Open Cell Nickel Foam

The effective thermal conductivity of high-porosity open cell nickel foam samples was measured over a wide range of temperatures and pressures using a standard steady-state technique. The samples, measuring 23.8 mm, 18.7 mm, and 13.6 mm in thickness, were constructed with layers of 1.7 mm thick foam with a porosity of 0.968. Tests were conducted with the specimens subjected to temperature differences of 100 to 1000 K across the thickness and at environmental pressures of 10(exp -4) to 750 mm Hg. All test were conducted in a gaseous nitrogen environment. A one-dimensional finite volume numerical model was developed to model combined radiation/conduction heat transfer in the foam. The radiation heat transfer was modeled using the two-flux approximation. Solid and gas conduction were modeled using standard techniques for high porosity media. A parameter estimation technique was used in conjunction with the measured and predicted thermal conductivities at pressures of 10(exp -4) and 750 mm Hg to determine the extinction coefficient, albedo of scattering, and weighting factors for modeling the conduction thermal conductivity. The measured and predicted conductivities over the intermediate pressure values differed by 13%.

Sullins, Alan D.