Search NASA⌕ Search

SEARCH · Search NASA

Results for “Pixel array detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Automated co-adding and energy calibration of large array microcalorimeter data with zero sample knowledge

State-of-the-art microcalorimeter spectrometers now contain large detector arrays with hundreds of individual pixels. Each individual pixel outputs a unique and non-linear response with respect to deposited energy. This work describes a pattern-recognition algorithm to combine these responses into a single energy-calibrated histogram, referred to as co-adding pixels. Photo-peaks from different pixels are matched together based upon how well the match aligns the centroids and heights of neighboring peaks. This usually results in around 100 co-adding calibration points from 30 to 300 keV for a several day acquisition of plutonium items with masses between 0.5 and 10 grams. An additional algorithm energy-calibrates this co-added spectrum using the fluoresced K x-ray emissions from a tantalum absorber and inherent x-ray escape peaks from the tin absorbers. Both algorithms operate without knowledge of the source and are fully automated. This work presents results from the acquisitions of high and low burnup plutonium, 10% enriched uranium, a 153 Gd calibration source, and a 57 Co+ 166m Ho calibration source. In all measurements, resolution defined as the full-width at half-maximum (FWHM) of photo-peaks is preserved between the individual pixel and co-added spectra at around 65 eV for incident photon energies between 60 and 208 keV. The energy calibration algorithm is approximate and yields a calibration curve off by an average of around 200 eV for incident photon energies between 60 and 208 keV.

47 OTHER INSTRUMENTATION↗

Characterization of silicon drift detectors with electrons for the TRISTAN project

Sterile neutrinos are a minimal extension of the standard model of particle physics. A promising model-independent way to search for sterile neutrinos is via high-precision β-spectroscopy. The Karlsruhe tritium neutrino (KATRIN) experiment, equipped with a novel multi-pixel silicon drift detector focal plane array and read-out system, named the TRISTAN detector, has the potential to supersede the sensitivity of previous laboratory-based searches. In this work we present the characterization of the first silicon drift detector prototypes with electrons and we investigate the impact of uncertainties of the detector’s response to electrons on the final sterile neutrino sensitivity.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Magnetic Microcalorimeter (MMC) Gamma Detectors with Ultra-High Energy Resolution

The goal of this LCP is to develop ultra-high resolution gamma-ray detectors based on magnetic microcalorimeters (MMCs) for accurate measurements of nuclear decay data and NDA of nuclear materials. For highest energy resolution, we are introducing erbium-doped silver (Ag:Er) as a novel sensor material and implement several geometry and design changes to improve the signal-to-noise ratio. The detector sensitivity will be increased by developing arrays of 32 Ag:Er pixels read out by 16 SQUID preamplifiers, and by developing a cryogenic Compton veto to reduce the spectral background. For highest energy resolution we will operate the MMC detector arrays in a dilution refrigerator with a base temperature <10 mK. The detector performance and utility will be demonstrated with radioactive sources of interest to the safeguards community. In FY16 and FY17, we had purchased a liquid-cryogen-free dilution refrigerator and installed 16 SQUID preamplifiers and writing for MMC detector operation at ~10 mK. We have also developed the process to fabricate the first Ag:Er-based MMCs, built prototype detector arrays and tested them with different radioactive sources. We have also shown that our MMC detectors can achieve the LCP goal of an energy resolution below 50 eV as needed to resolve most closelyspaced lines of interest for NDA. The goals for FY18 were then 1) to optimize the MMC design based on the measured detector characteristics and to increase the array size to 32-pixels for increased sensitivity, and 2) to demonstrate the utility of MMC gamma-ray detectors in applications relevant in nuclear safeguards.

42 ENGINEERING↗

Characterization of EJ-270 and Ce-doped LiCAF scintillators for the development of high-rate neutron reflectometer detectors

The Second Target Station of the Spallation Neutron Source at Oak Ridge National Laboratory is anticipated to provide a neutron source with ∼20 times increase in peak brightness than the First Target Station. The neutron reflectometers currently in operation at the First Target Station need to be upgraded due to the increased neutron flux. A prototype neutron detector module based upon a pixelated scintillator array readout by silicon photomultipliers is being developed to address the high-rate challenge faced with future neutron reflectometer instruments at the Second Target Station. Two types of scintillator materials were considered for this detector development, i.e., 6 Li-loaded EJ-270 plastic scintillator and Ce-doped LiCAF single crystal. This paper reports the scintillator characterization results, including light yield, pulse shape discrimination performance, capability to detect thermal neutrons in a high γ-ray field, and γ-ray sensitivity. The number of photons produced per neutron capture by EJ-270 and LiCAF:Ce was measured to be 2176 ± 91 and 2651 ± 108, respectively. EJ-270 demonstrated a good capability to discriminate between neutrons and γ-rays by employing the commonly used charge comparison method (figure-of-merit: 1.13 ± 0.01 for an energy cut of 292–426 keVee) and a reasonable performance when using the time-over-threshold techniques; however, no discrimination was observed from LiCAF:Ce regardless of the pulse shape discrimination approaches utilized, making pulse height discrimination necessary for LiCAF:Ce to differentiate between neutrons and γ-rays. Both EJ-270 and LiCAF:Ce exhibited an acceptable capacity to detect thermal neutrons at high exposure rates up to approximately 584 mR/h. Furthermore, the γ-ray sensitivities measured with a 60 Co source at an exposure rate of around 1145 mR/h were determined to be (6.11 ± 0.87) × 10 −6 and (7.64 ± 1.08) × 10 −7 for EJ-270 and LiCAF:Ce, respectively.

EJ-270↗

High Energy Micron Scale Pixel Hybrid Detector

The objective of this technology development project has been to fabricate and characterize a new X-ray area image sensor innovation designed for high efficiency detection and imaging of hard X-rays (>20 KeV) with micron scale pixel resolution. A key technology component consists of a monolithic hybrid X-ray detector built by layering an amorphous Selenium X-ray photoconductor film directly deposited on a small pitch (7.8μm) CMOS active pixel readout array. A specific goal of this work is to provide a new detector tool to researchers working with synchrotron light sources, to extend the depth of exploration into nanoscale structures, and do so cost effectively. Early generation X-ray imaging detector tools fail to provide adequate resolving power and efficiency at high energies and our innovation provides a solution. A majority of proposed phase I tasks were completed. Those tasks included, in collaboration with KA Imaging, successful fabrication of specified a-Se layers on a 1Mpixel CMOS readout array to create the direct hybrid X-ray imaging array, packaging of the imaging array, assembly of electronics into a shielded detector box, loading user interface software for camera control and image capture, and performing initial (no X-ray) detector evaluation at Farrier Microengineering facilities. After initial tests, extensive testing using the X-ray beam line 1-BM source at Argonne National Laboratory Advanced Photon Source(ANL-APS) was performed. Imaging performance studies were conducted at multiple X-ray beam energies. Studies included X-ray response vs. X-ray energy, vs. applied detector field strength (HV), response linearity vs. integration time, MTF vs. beam energy, image lag measurements, and micron scale resolution pattern target imaging. This high energy micron scale X-ray detection technology is a first of a kind to be evaluated at the ANL-APS and is supported by Dr. Antonino Miceli, head of the detector physics group. Accomplishments include the first successful demonstration of a 1Mpix amorphous Selenium on CMOS readout direct hybrid X-ray imaging detector at a DOE sponsored National Laboratory. Modeled performance predictions were confirmed, proving micron scale resolution as well as an order of magnitude increase in conversion efficiency over conventional scintillator detector performance. A discovery of evidence of propagation-based phase contrast edge enhancement was unplanned and will be exploited in future experiments. This phase 1 technology demonstration verifies the efficacy of proposed high energy micron scale pixel X-ray hybrid a-Se imaging array products. The new detector products will cost effectively replace early generation detector technologies that currently fail to address increasing demand for tools to study nano structures and physical processes at high X-ray energies above 20keV. For example, current systems for transmission X-ray microscopy have low efficiency and available large pixel (~55µm) direct detectors do not offer sufficient resolution for Bragg fringe imaging at high energies. This detector innovation will solve these inadequacies. The new detector technology will compete in a $50M scientific X-ray detector market, growing at 6%, and will benefit Microtomography(µCT), X-ray diffractometry (XRD), Coherent Diffraction Imaging (CDI) applications. One application specified by Dr. Miceli at ANL is the 3D reconstruction of compact crystals at high energies requires small pixel high efficiency X-ray detectors. Farrier Microengineering, working with colleagues at KA Imaging and the University of Waterloo, successfully achieved the critical objectives of the Phase I proposal. We have proven the technical feasibility of this innovation by building and successfully testing a 1Mpixel a-Se/CMOS hybrid direct X-ray imaging array. Our commercialization roadmap of detector products will be implemented during a phase II project. We will demonstrate a migration of the technology to larger detector array sizes, improved temporal performance with detector layer engineering, and improved environmental and operational stability. Manufacturability and cost effectiveness are key objectives and product designs will leverage current state of the art CMOS wafer fabrication quality and volume manufacturing economics.

36 MATERIALS SCIENCE↗

Characterization of a Pixelated Cadmium Telluride Detector System Using a Polychromatic X-Ray Source and Gold Nanoparticle-Loaded Phantoms for Benchtop X-Ray Fluorescence Imaging

In this paper, the imaging dose and scan time have been considered as the two major constraints for routine benchtop x-ray fluorescence computed tomography (XFCT) imaging. One way to address this issue is to acquire x-ray fluorescence (XRF) signals in parallel through a 2D array of single-crystal detectors or a pixelated detector along with the cone-beam x-ray source. To identify a detector system suitable for this purpose, a commercially available, fully spectroscopic cadmium telluride (CdTe) pixelated detector, HEXITEC (High-Energy X-ray Imaging Technology), was tested under the experimental conditions optimized for benchtop XFCT imaging of gold nanoparticles (GNPs). Specifically, two different parallel-hole stainless steel collimators were fabricated and coupled with the detector for seamless integration into our existing benchtop cone-beam XFCT system. After the detector deployment, this benchtop XFCT system was used to detect XRF photons from GNP-loaded phantoms. A pixel-merging algorithm was introduced to enhance the sensitivity of XRF photon detection thereby minimizing the scan time. The effect of pixel-level charge sharing correction algorithms was investigated within the context of benchtop XFCT imaging. The detector energy resolution, in terms of the full width at half maximum (FWHM) values at different gold K-shell XRF energies, was also determined. Of the two charge sharing correction algorithms examined, the charge sharing addition gave better sensitivity than the charge sharing discrimination (csd). On the other hand, under the current experimental conditions, the energy resolution of the HEXITEC detector was the best with the csd and estimated to be 1.56 keV FWHM at 66-69 keV photon energy. Overall, despite some degradation of the detector energy resolution (compared with typical single crystal CdTe detectors), the HEXITEC detector enabled parallel data acquisition under the experimental conditions typical of benchtop XFCT imaging and operated well within our benchtop XFCT setup.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of a coarsely pixelated LAPPD photosensor for the SoLID gas Cherenkov detectors

The SoLID spectrometer's gas Cherenkov counters require photosensors that operate in a high luminosity and high background environment. The reference design features arrays of 9 or 16 tiled multi-anode photomultipliers (MaPMTs), distributed across 32 sectors, to serve the light-gas and heavy-gas Cherenkov counters, respectively. To assess the viability of a pixelated INCOM Large Area Picosecond Photodetector (LAPPD TM ) as an alternative photosensor to replace MaPMT arrays in either detector, we evaluated its performance under realistic SoLID running conditions in Hall C at the Thomas Jefferson National Accelerator Facility (Jefferson Lab). The results of this test confirmed that the coarse-pixelated (2.5 × 2.5 cm 2 pixel size) LAPPD is capable of handling the total projected signal and background rates of the three pillar SoLID experiments. The tested photosensor detected Cherenkov signals with the capability of separating single-electron events from pair production events while rejecting background. Although the design was not aimed at ring-imaging Cherenkov detectors, Cherenkov disk images were captured in two different gas radiators. Through a direct comparison with a GEANT4 simulation, we confirmed the experimental performance of the LAPPD.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The brighter-fatter effect in the JWST MIRI Si:As IBC detectors: I. Observations, impact on science, and modeling

Context.The Mid-Infrared Instrument (MIRI) on board theJames WebbSpace Telescope (JWST) uses three Si:As impurity band conduction (IBC) detector arrays. The output voltage level of each MIRI detector pixel is digitally recorded by sampling up the ramp. For uniform or low-contrast illumination, the pixel ramps become nonlinear in a predictable way, but in areas of high contrast, the nonlinearity curve becomes much more complex. The origin of the effect is poorly understood and currently not calibrated out of the data. Aims.We provide observational evidence of the brighter-fatter effect (BFE) in MIRI conventional and high-contrast coronagraphic imaging, low-resolution spectroscopy, and medium-resolution spectroscopy data, and we investigate the physical mechanism that gives rise to the effect on the MIRI detector pixel raw voltage integration ramps. Methods.We used public data from the JWST/MIRI commissioning and Cycle 1 phase. We also developed a numerical electrostatic model of the MIRI detectors using a modified version of the publicPoisson_CCDcode. Results.We find that the physical mechanism behind the BFE manifesting in MIRI data is fundamentally different to that of charge-coupled devices and photodiode arrays such as the Hawaii-XRG near-infrared detectors used by the NIRISS, NIRCam, and NIRSpec instruments on board JWST. Observationally, the BFE makes the JWST MIRI data yield 10–25% larger point sources and spectral line profiles as a function of the relative level of de-biasing of neighboring detector pixels. This broadening impacts the MIRI absolute flux calibration, time-series observations of faint companions, and point spread function modeling and subtraction. We also find that the intra-pixel 2D profile of the shrinking Si:As IBC detector depletion region directly impacts the accuracy of the pixel ramp nonlinearity calibration model.

Astronomy & Astrophysics↗

Fast neutron radiography-based on single-photon digital photosensor: concept and demonstration

For decades, fast neutron radiography performed using pulse-counting detectors employed PMTs coupled to plastic scintillator pixel arrays. SiPM-based systems are now sought to replace fragile PMTs, but conventional, “analog” SiPMs suffer from intrinsic limitations which limit their achievable performance. Among these limitations, a complete analog readout and digitizer chain is required, a counterintuitive approach when considering that the single-photon avalanche diode (SPAD), the basic unit cell of SiPMs, is a Boolean detector providing digital detection at the sensor level. This paper outlines a new concept for neutron radiography instrumentation by using photon-to-digital converters (PDCs, aka digital SiPMs), a fully digital solution to sense the scintillation light.

Pratte, Jean-Francois↗

End-to-End Simulations of a 3.4-Meter Detector Wall for Neutron-Diagnosed Subcritical Experiments

The Nevada National Security Site, together with Los Alamos National Laboratory and Lawrence Livermore National Laboratory, is developing a novel diagnostic to measure the reactivity of subcritical experiments. This capability is known as neutron-diagnosed subcritical experiments. The decay of the fission gamma rays from the neutron-interrogated subcritical experiment is measured as a function of time with a large (~3-meter diameter) detector wall consisting of 151 individual detector pixels. The data from this current mode measurement inform the neutron multiplication factor, keff, and thus the relative reactivity of the subcritical experiment. The Nevada National Security Site developed the Gamma Array Simulation Toolkit initially to help inform the design of the individual detector pixels and the 3.4-meter diameter detector wall to be fielded as part of neutron-diagnosed subcritical experiments. This toolkit is now being used to simulate and predict the performance of the final design of the individual detector pixels and the aggregate detector wall. Key detector characteristics evaluated from these simulations include impulse response, pulse height spectrum, number of photoelectrons per MeV, detector efficiency, and cross talk between detector pixels. Collectively, the results of these simulations inform how well the fission gamma ray die-off distribution from a neutron-diagnosed subcritical experiment measurement can be resolved. This is critical to determining the relative reactivity of the experiment. Furthermore, the Gamma Array Simulation Toolkit can be used to aid in the analysis of the experimental data from a neutrondiagnosed subcritical experiment measurement once the simulation has been benchmarked.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

End-to-End Simulations of a 3.4-Meter Detector Wall for Neutron-Diagnosed Subcritical Experiments

The Nevada National Security Site, together with Los Alamos National Laboratory and Lawrence Livermore National Laboratory, is developing a novel diagnostic to measure the reactivity of subcritical experiments. This capability is known as neutron-diagnosed subcritical experiments. The decay of the fission gamma rays from the neutron-interrogated subcritical experiment is measured as a function of time with a large (~3-meter diameter) detector wall consisting of 151 individual detector pixels. The data from this current mode measurement inform the neutron multiplication factor, keff, and thus the relative reactivity of the subcritical experiment. The Nevada National Security Site developed the Gamma Array Simulation Toolkit initially to help inform the design of the individual detector pixels and the 3.4-meter diameter detector wall to be fielded as part of neutron-diagnosed subcritical experiments. This toolkit is now being used to simulate and predict the performance of the final design of the individual detector pixels and the aggregate detector wall. Key detector characteristics evaluated from these simulations include impulse response, pulse height spectrum, number of photoelectrons per MeV, detector efficiency, and cross talk between detector pixels. Collectively, the results of these simulations inform how well the fission gamma ray die-off distribution from a neutron-diagnosed subcritical experiment measurement can be resolved. This is critical to determining the relative reactivity of the experiment. Furthermore, the Gamma Array Simulation Toolkit can be used to aid in the analysis of the experimental data from a neutron-diagnosed subcritical experiment measurement once the simulation has been benchmarked.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

End-to-End Simulations of a 3.4-Meter Detector Wall for Neutron-Diagnosed Subcritical Experiments

The Nevada National Security Site, together with Los Alamos National Laboratory and Lawrence Livermore National Laboratory, is developing a novel diagnostic to measure the reactivity of subcritical experiments. This capability is known as neutron-diagnosed subcritical experiments. The decay of the fission gamma rays from the neutron-interrogated subcritical experiment is measured as a function of time with a large (~3-meter diameter) detector wall consisting of 151 individual detector pixels. The data from this current mode measurement inform the neutron multiplication factor, keff, and thus the relative reactivity of the subcritical experiment. The Nevada National Security Site developed the Gamma Array Simulation Toolkit initially to help inform the design of the individual detector pixels and the 3.4-meter diameter detector wall to be fielded as part of neutron-diagnosed subcritical experiments. This toolkit is now being used to simulate and predict the performance of the final design of the individual detector pixels and the aggregate detector wall. Additionally, key detector characteristics evaluated from these simulations include impulse response, pulse height spectrum, number of photoelectrons per MeV, detector efficiency, and cross talk between detector pixels. Collectively, the results of these simulations inform how well the fission gamma ray die-off distribution from a neutron-diagnosed subcritical experiment measurement can be resolved. This is critical to determining the relative reactivity of the experiment. Furthermore, the Gamma Array Simulation Toolkit can be used to aid in the analysis of the experimental data from a neutron-diagnosed subcritical experiment measurement once the simulation has been benchmarked.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pixel-to-pixel variation on a calibrated PILATUS3-based multi-energy soft x-ray detector

A multi-energy soft x-ray pin-hole camera based on the PILATUS3 100 K x-ray detector has recently been installed on the Madison Symmetric Torus. This photon-counting detector consists of a two-dimensional array of ∼100 000 pixels for which the photon lower-threshold cutoff energy Ec can be independently set for each pixel. This capability allows the measurement of plasma x-ray emissivity in multiple energy ranges with a unique combination of spatial and spectral resolution and the inference of a variety of important plasma properties (e.g., Te, nZ, Zeff). The energy dependence of each pixel is calibrated for the 1.6–6 keV range by scanning individual trimbit settings, while the detector is exposed to fluorescence emission from Ag, In, Mo, Ti, V, and Zr targets. The resulting data for each line are then fit to a characteristic “S-curve” which determines the mapping between the 64 possible trimbit settings for each pixel. The statistical variation of this calibration from pixel-to-pixel was explored, and it was found that the discreteness of trimbit settings results in an effective threshold resolution of ΔE < 100 eV. A separate calibration was performed for the 4–14 keV range, with a resolution of ΔE < 200 eV.

VanMeter, P. (ORCID:0000000244537948)↗

Temperature-dependent characterization of large-area superconducting microwire array with single-photon sensitivity in the near-infrared

Superconducting nanowire single photon detectors (SNSPDs) are a leading detector technology for time-resolved single-photon counting from the ultraviolet to the near-infrared regime. The recent advancement in single-photon sensitivity in micrometer-scale superconducting wires opens up promising opportunities to develop large area SNSPDs with applications in low background dark matter detection experiments. Here, we present the first detailed temperature-dependent study of a 4-channel 1×1 mm 2 WSi superconducting microwire single photon detector (SMSPD) array, including the internal detection efficiency, dark count rate, and importantly the coincident dark counts across pixels. The detector shows saturated internal detection efficiency for photon wavelengths ranging from 635 nm to 1650 nm, time jitter of about 160 ps for 1060 nm photons, and a low dark count rate of about 10 -2 Hz. Additionally, the coincidences of dark count rate across pixels are studied for the first time in detail, where we observed an excess of correlated dark counts, which has important implications for low background dark matter experiments. The results presented is the first step towards characterizing and developing SMSPD array systems and associated background for low background dark matter detection experiments.

47 OTHER INSTRUMENTATION↗

Magnetic Microcalorimeter (MMC) Gamma Detectors with Ultra-High Energy Resolution

The goal of this LCP is to develop ultra-high resolution gamma detectors based on magnetic microcalorimeters (MMCs) for accurate non-destructive analysis (NDA) of nuclear materials. For highest energy resolution, we will introduce erbium-doped silver (Ag:Er) as a novel sensor material, and implement several geometry and design changes to improve the signal-to-noise ratio. The detector sensitivity will be increased by developing arrays of 32 Ag:Er pixels read out by 16 SQUID preamplifiers, and by developing a cryogenic Compton veto to reduce the spectral background. Since best MMC performance requires detector operation at ~10 mK, we will purchase a dilution refrigerator with a base temperature <10 mK and adapt it for MMC operation. The detector performance will be tested with radioactive sources of interest to the safeguards community.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Test and characterization of finely segmented pixel CZT detectors for future hard x-ray missions

The NuSTAR (Nuclear Spectroscopic Telescope Array) mission was launched in 2012, and it has successfully deployed the first orbiting telescopes to focus high energy X-ray (3 - 79 keV) light, providing a wealth of new information on high-energy X-rays sources. Follow-up missions, such as the proposed HEX-P, BEST, and FORCE, could perform a deeper black hole census providing a more refined measurement of black hole spins, allowing for greater knowledge about supermassive black holes. Here, these missions are motivated by the recent breakthroughs in the hard X-ray mirror technologies, where mirrors, either made of monolithic silicon segments, or made directly or via replication of shells, demonstrate the feasibility of making hard X-ray mirrors with angular resolutions of 5-10 arc-seconds Half Power Diameter (HPD) compared to the NuSTAR’s 1 arc-minute HPD. Such a high angular resolution requires matched detectors with higher degree of segmentation to fully benefit from the achievable improved spatial resolution. In the above framework, the HEXID ASIC, a novel pixelated front-end suitable for reading out a finely segmented CZT sensor with 150 μm pixel pitch in a hexagonal arrangement has been developed. This readout pixelated chip is capable of processing photon-generated charge packets over a large dynamic range (from 2 keV up to 180 keV), while keeping a low input noise (ENC <20 e - ). In this work, the initial characterization of the ASIC prototype will be presented.

47 OTHER INSTRUMENTATION↗

Robust analysis of space-, time-, and energy-resolved soft x-ray measurements of magnetically confined fusion plasmas (invited)

A novel compact multi-energy soft x-ray (ME-SXR) diagnostic based on the PILATUS3 100K x-ray detector has been developed in collaboration between the Princeton Plasma Physics Laboratory and the University of Wisconsin-Madison and tested on the Madison Symmetric Torus (MST) reversed-field pinch. This solid-state photon-counting detector consists of a two-dimensional array of ~100 000 pixels for which the lower photon absorption cutoff energy can be independently set, allowing it to be configured for a unique combination of simultaneous spatial, spectral, and temporal resolution of ~1 cm, 100 eV, and 500 Hz, respectively. The diagnostic is highly versatile and can be readily adapted to diverse plasma operating conditions and scientific needs without any required downtime. New results from improved-confinement and quasi-single helicity plasmas in the MST demonstrate how the detector can be applied to study multiple aspects of the evolution of magnetically confined fusion-grade plasmas. These include observing the evolution of thermal emissivity, characterizing the energy of mid-Z excitation lines, extracting the T e profile, and observing the evolution of non-thermal populations. A technique for integrating the ME-SXR diagnostic into an integrated data analysis framework based on Bayesian inference is also presented. As a result, this allows ME-SXR measurements to be combined with data for complementary diagnostics in order to simultaneously infer Te and nZ from all available information.

47 OTHER INSTRUMENTATION↗

Characterization and performance of the second-year SPT-3G focal plane

The third-generation instrument for the 10-meter South Pole Telescope, SPT-3G, was first installed in January 2017. In addition to completely new cryostats, secondary telescope optics, and readout electronics, the number of detectors in the focal plane has increased by an order of magnitude from previous instruments to ~16,000. The SPT-3G focal plane consists of ten detector modules, each with an array of 269 trichroic, polarization-sensitive pixels on a six-inch silicon wafer. Within each pixel is a broadband, dual-polarization sinuous antenna; the signal from each orthogonal linear polarization is divided into three frequency bands centered at 95, 150, and 220 GHz by in-line lumped element filters and transmitted via superconducting microstrip to Ti/Au transition-edge sensor (TES) bolometers. Properties of the TES film, microstrip filters, and bolometer island must be tightly controlled to achieve optimal performance. For the second year of SPT-3G operation, we have replaced all ten wafers in the focal plane with new detector arrays tuned to increase mapping speed and improve overall performance. Here we discuss the TES superconducting transition temperature and normal resistance, detector saturation power, bandpasses, optical efficiency, and full array yield for the 2018 focal plane.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗