Search NASA⌕ Search

SEARCH · Search NASA

Results for “Precision”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Precision of ENDF and ENDL Formatted Data Files

The purpose is to ensure that today’s processing codes produced output to meet today’s accuracy needs. Since 1958 ENDL and about 1965 ENDF have each used a text format to define nuclear and atomic data in 11 columns for each data field. When these formats originated this was judged to be adequate to reproduce the accuracy of data at the time and to meet the needs of our applications. When these formats originated the dominant computer language of the day was FORTRAN and if written using an E11.4 format it would include only 4 or 5 digits of precision, e.g., 0.1234E-03 or 1.2345E-02, varying from one computer/system to another the result was not even unique. In the case of ENDF the 4 digit precision was not even adequate to uniquely define the atomic weight of the target, e.g., U238 = 92238 = 0.9224E+5 = WRONG! From its inceptions the ENDF format had a precision problem. One of my first tasks when in 1967 fresh out of graduate school I joined what later became the National Nuclear Data Center (NNDC), was to address this precision problem. By working with ENDF producers and users throughout the U.S. we verified, 1) E or D is not required to define FORTRAN readable numbers, e.g., E+4 or +4 are both o.k. 2) With ENDF energy eV and cross section in barns, 2 digit exponents are almost never required. 3) Since energy is never negative we could use the first of the 11 columns for a digit. Knowing this allowed us to produce ENDF/B-II to 6 or 7 digit precision, e.g., blank, decimal point, 2 or 3 digit exponent, e.g., ^1.23456-12 or ^1.234567-3. Below is an example of the actual ENDF/B-II data released. Note, the date 1970 and the atomic weight, ZA, uniquely defined to 6-digit accuracy, ^9.22350+ 4.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Status of CHIP-TRAP: The Central Michigan University High-Precision Penning Trap

Precise and accurate atomic mass data provide crucial information for applications in a wide range of fields in physics and beyond, including astrophysics, nuclear structure, particle and neutrino physics, fundamental symmetries, chemistry, and metrology. The most precise atomic mass measurements are performed on charged particles confined in a Penning trap. Here, we describe the development, status, and outlook of CHIP-TRAP: the Central Michigan University high-precision Penning trap. CHIP-TRAP aims to perform ultra-high precision (~1 part in 10 11 fractional precision) mass measurements on stable and long-lived isotopes produced with external ion sources and transported to the Penning traps. Along the way, ions of a particular m/q are selected with a multi-reflection time-of-flight mass separator (MR-TOF-MS), with further filtering performed in a cylindrical capture trap before the ions are transported to a pair of hyperbolic measurement traps. In this paper, we report on the design and status of CHIP-TRAP and present results from the commissioning of the ion sources, MR-TOF-MS, and capture trap. We also provide an outlook on the continued development and commissioning of CHIP-TRAP.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Performance Verification of the EXtreme PREcision Spectrograph

The EXtreme PREcision Spectrograph (EXPRES) is a new Doppler spectrograph designed to reach a radial-velocity measurement precision sufficient to detect Earth-like exoplanets orbiting nearby, bright stars. We report on extensive laboratory testing and on-sky observations to quantitatively assess the instrumental radial-velocity measurement precision of EXPRES, with a focused discussion of individual terms in the instrument error budget. We find that EXPRES can reach a single-measurement instrument calibration precision better than 10 cm s{sup −1}, not including photon noise from stellar observations. We also report on the performance of the various environmental, mechanical, and optical subsystems of EXPRES, assessing any contributions to radial-velocity error. For atmospheric and telescope related effects, this includes the fast tip-tilt guiding system, atmospheric dispersion compensation, and the chromatic exposure meter. For instrument calibration, this includes the laser fRequency comb (LFC), flat-field light source, CCD detector, and effects in the optical fibers. Modal noise is mitigated to a negligible level via a chaotic fiber agitator, which is especially important for wavelength calibration with the LFC. Regarding detector effects, we empirically assess the impact on the radial-velocity precision due to pixel-position nonuniformities and charge transfer inefficiency (CTI). EXPRES has begun its science survey to discover exoplanets orbiting G-dwarf and K-dwarf stars, in addition to transit spectroscopy and measurements of the Rossiter–McLaughlin effect.

79 ASTRONOMY AND ASTROPHYSICS↗

Low Precision and Efficient Programming Languages for Sustainable AI: Final Report for the Summer Project of 2024

This document contains all relevant material generated during the authors' summer internship at NREL in 2024. This report shows how to improve energy efficiency of a few code samples by using low-precision data types combined with mixed-precision algorithms. The main applications considered here are (i) linear system solvers using mixed precision, and (ii) neural networks using mixed precision. This report also discusses how programming languages affect energy consumption of algorithms, energy metrics for a code and tools, and the available current software and hardware infrastructure.

97 MATHEMATICS AND COMPUTING↗

Speeding up and reducing memory usage for scientific machine learning via mixed precision

Scientific machine learning (SciML) has emerged as a versatile approach to address complex computational science and engineering problems. Within this field, physics-informed neural networks (PINNs) and deep operator networks (DeepONets) stand out as the leading techniques for solving partial differential equations by incorporating both physical equations and experimental data. However, training PINNs and DeepONets require significant computational resources, including long computational times and large amounts of memory. In search of computational efficiency, training neural networks using half precision (float16) rather than the conventional single (float32) or double (float64) precision has gained substantial interest, given the inherent benefits of reduced computational time and memory consumed. However, we find that float16 cannot be applied to SciML methods, because of gradient divergence at the start of training, weight updates going to zero, and the inability to converge to a local minima. To overcome these limitations, we explore mixed precision, which is an approach that combines the float16 and float32 numerical formats to reduce memory usage and increase computational speed. Our experiments showcase that mixed precision training not only substantially decreases training times and memory demands but also maintains model accuracy. Here, we also reinforce our empirical observations with a theoretical analysis. The research has broad implications for SciML in various computational applications.

97 MATHEMATICS AND COMPUTING↗

The electroweak precision constraints of the 2HDM+S

The 2HDM+S is the singlet extension of the Two-Higgs-Doublets Model (2HDM). The singlet field and its mixing with the 2HDM Higgs sector lead to new contributions to the electroweak precision observables, in particular, the oblique parameters. In this paper, we performed a systematic study of the impacts of each mixing angle to the oblique parameters. We adopted the mixing angles and physical Higgs masses as our parameters, which allows a mapping when specific symmetry structure of the Higgs potential and various theoretical considerations are taken into account. We identify five benchmark cases, where at most one mixing angle is nonzero and analyze the 95\% C.L. allowed parameter space by the oblique parameters. In the alignment limit of the 2HDM, we find that other than the usual mass relations of $m_H\sim m_{H^\pm}$ or $m_A\sim m_{H^\pm}$, electroweak precision measurements also impose an upper limit on the neutral Higgs masses. In the cases with nonzero singlet mixing with the 2HDM Higgses $H$ or $A$, we find approximate mass relations of $c^2_{\alpha_{HS}} m_{H} + s^2_{\alpha_{HS}}m_{h_S} = m_{H^\pm}$ or $c^2_{\alpha_{AS}} m_{A} + s^2_{\alpha_{AS}}m_{A_S} = m_{H^\pm}$. Those relations are universal to the 2HDM+S models, with or without further symmetry assumption. We also study the non-alignment limit of the 2HDM+S, which typically has tighter constraints on the masses and mixing angles. At the end, we examine the complementarity between the electroweak precision analyses and the Higgs coupling precision measurements.

2HDM↗

Replicated Computational Results (RCR) Report for “Adaptive Precision Block-Jacobi for High Performance Preconditioning in the Ginkgo Linear Algebra Software”

The article by Flegar et al. titled “Adaptive Precision Block-Jacobi for High Performance Preconditioning in the Ginkgo Linear Algebra Software” presents a novel, practical implementation of an adaptive precision block-Jacobi preconditioner. Performance results using state-of-the-art GPU architectures for the block-Jacobi preconditioner generation and application demonstrate the practical usability of the method, compared to a traditional full-precision block-Jacobi preconditioner. A production-ready implementation is provided in the Ginkgo numerical linear algebra library. In this report, the Ginkgo library is reinstalled and performance results are generated to perform a comparison to the original results when using Ginkgo’s Conjugate Gradient solver with either the full or the adaptive precision block-Jacobi preconditioner for a suite of test problems on an NVIDIA GPU accelerator. After completing this process, the published results are deemed reproducible.

97 MATHEMATICS AND COMPUTING↗

New approach to precisely measure γ-ray intensities for long-lived fission products, with results for the decay of 95 Zr

For many fission products, the rays emitted following decay provide an easily-detectable signature that can be used to identify their quantities and distributions in a sample. As a result, γ-ray spectroscopy is often exploited to study fission-product yields, provided sufficiently accurate information on the γ-ray intensity is available. However, in many cases, the uncertainties in the existing nuclear data are large enough that they compromise the precision achievable for modern experiments and applications. To address this need, we have developed a new experimental method that is well suited to precisely measure absolute γ-ray intensities in the β decay of long-lived fission products. The approach involves the production of a radiopure sample by implantation of a mass-separated ion beam from the CAlifornium Rare Isotope Breeder Upgrade (CARIBU) facility on a thin carbon foil. The emitted β-decay radiation is detected with a 4π gas proportional counter and a meticulously efficiency-calibrated high-purity germanium (HPGe) detector. As a first measurement to demonstrate the approach, we studied the absolute γ-ray intensities of the strongest transitions following the β decay of 95 Zr and its decay-daughter 95 Nb, and determined them to fractional precisions of better than 1–2%. In addition, with a larger sample of activity produced through neutron irradiation of an isotopically-enriched Zr foil, we performed a high-precision measurement of the relative γ-ray intensities following the decay of 95 Zr with just the HPGe detector. Here, the sample-production method at CARIBU and the coincidence detection approach demonstrated here can be applied to study fission products with half-lives longer than a day, which includes isotopes important not only for nuclear-energy and national-security applications, but also for medical-isotope research and environmental monitoring.

4π↗

Photocathode characterisation for robust PICOSEC Micromegas precise-timing detectors

The PICOSEC Micromegas detector is a precise-timing gaseous detector based on a Cherenkov radiator coupled with a semi-transparent photocathode and a Micromegas amplifying structure, targeting a time resolution of tens of picoseconds for minimum ionising particles. Initial single-pad prototypes have demonstrated a time resolution below σ = 25 ps, prompting ongoing developments to adapt the concept for High Energy Physics applications, where sub-nanosecond precision is essential for event separation, improved track reconstruction and particle identification. The achieved performance is being transferred to robust multi-channel detector modules suitable for large-area detection systems requiring excellent timing precision. To enhance the robustness and stability of the PICOSEC Micromegas detector, research on robust carbon-based photocathodes, including Diamond-Like Carbon (DLC) and Boron Carbide (B 4 C), is pursued. Results from prototypes equipped with DLC and B 4 C photocathodes exhibited a time resolution of σ ≈ 32 ps and σ ≈ 34.5 ps, respectively. Efforts dedicated to improve detector robustness and stability enhance the feasibility of the PICOSEC Micromegas concept for large experiments, ensuring sustained performance while maintaining excellent timing precision.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Facile Approach to High Precision Detection of Cell-to-Cell Variation for Li-ion Batteries

Abstract Over the past decade, it has been repeatedly demonstrated that homogeneity in electrochemical performance of lithium-ion cells plays a major role in determining the life and safety of lithium-ion battery modules or packs. Generally, the homogeneity of a battery pack is evaluated by characterizing the cells individually in terms of capacity, mass, impedance. Particularly, high quality electrochemical data heavily relies on the availability of high precision current source to minimize the discrepancy induced by the channel-to-channel variation. Here, a facile and precise measurement method is reported for screening cell-to-cell variations, in which voltage is the only indicator parameter independent of high precision current source. In detail, by connecting the cells in series (CiS), the measurement error of electrochemical data caused by stability and discrepancy of current sources among different charge/discharge equipment can be effectively avoided. The findings of this work showed that the cell-to-cell variations can be simply and sensitively detected with CiS configuration. For example, the relative standard deviation, which is the evaluation criterion of battery homogeneity, was 2.14% based on CiS while it was 0.43% based on individual measurements. The simple and precise CiS measurement is promising for evaluation of cell quality or module integration quality. In addition, this work can also provide a solid foundation for the development of detection algorithms for battery management systems to rapidly monitor battery homogeneity.

25 ENERGY STORAGE↗

Compressing deep neural networks on FPGAs to binary and ternary precision with hls4ml

We present the implementation of binary and ternary neural networks in the hls4ml library, designed to automatically convert deep neural network models to digital circuits with FPGA firmware. Starting from benchmark models trained with floating point precision, we investigate different strategies to reduce the network's resource consumption by reducing the numerical precision of the network parameters to binary or ternary. We discuss the trade-off between model accuracy and resource consumption. In addition, we show how to balance between latency and accuracy by retaining full precision on a selected subset of network components. As an example, we consider two multiclass classification tasks: handwritten digit recognition with the MNIST data set and jet identification with simulated proton-proton collisions at the CERN Large Hadron Collider. The binary and ternary implementation has similar performance to the higher precision implementation while using drastically fewer FPGA resources.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A variational encoder–decoder approach to precise spectroscopic age estimation for large Galactic surveys

Constraints on the formation and evolution of the Milky Way Galaxy require multidimensional measurements of kinematics, abundances, and ages for a large population of stars. Ages for luminous giants, which can be seen to large distances, are an essential component of studies of the Milky Way, but they are traditionally very difficult to estimate precisely for a large data set and often require careful analysis on a star-by-star basis in asteroseismology. Because spectra are easier to obtain for large samples, being able to determine precise ages from spectra allows for large age samples to be constructed, but spectroscopic ages are often imprecise and contaminated by abundance correlations. Here we present an application of a variational encoder–decoder on cross-domain astronomical data to solve these issues. The model is trained on pairs of observations from APOGEE and Kepler of the same star in order to reduce the dimensionality of the APOGEE spectra in a latent space while removing abundance information. The low dimensional latent representation of these spectra can then be trained to predict age with just ∼1000 precise seismic ages. We demonstrate that this model produces more precise spectroscopic ages (∼ 22 per cent overall, ∼ 11 per cent for red-clump stars) than previous data-driven spectroscopic ages while being less contaminated by abundance information (in particular, our ages do not depend on [α/M]). We create a public age catalogue for the APOGEE DR17 data set and use it to map the age distribution and the age-[Fe/H]-[α/M] distribution across the radial range of the Galactic disc.

79 ASTRONOMY AND ASTROPHYSICS↗

Ultrahigh-precision Compton polarimetry at 2 GeV

Here we report a high precision measurement of electron beam polarization using Compton polarimetry. The measurement was made in experimental Hall A at Jefferson Lab during the CREX experiment in 2020. A precision of dP/P = 0.36% was achieved detecting the back-scattered photons from the Compton scattering process. This is the highest precision in a measurement of electron beam polarization using Compton scattering ever reported, surpassing the ground-breaking measurement from the SLD Compton polarimeter. Such precision reaches the level required for the future flagship measurements to be made by the MOLLER and SoLID Experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SMEFT probes in future precision DIS experiments

We analyze the potential of future high-energy deep-inelastic scattering (DIS) experiments to probe new physics within the framework of the Standard Model effective field theory (SMEFT). We perform a detailed study of SMEFT probes at a future Large Hadron-electron Collider (LHeC) and a Future Circular lepton-hadron Collider (FCC-eh) machine, and extend previous simulations of the potential of an electron-ion collider (EIC) to include 𝑍-boson vertex corrections. Precision 𝑍-pole constraints on vertex corrections suffer from numerous degeneracies in the Wilson-coefficient parameter space. We find that both the LHeC and the FCC-eh can help remove these degeneracies present in the existing global fits of precision 𝑍-pole observables and LHC data. The FCC-eh and LHeC will in many cases improve upon the existing precision electroweak bounds on the SMEFT parameter space. This highlights the important role of precision DIS measurements for new physics studies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Understanding Mixed Precision GEMM with MPGemmFI: Insights into Fault Resilience

Emerging deep learning workloads urgently need fast general matrix multiplication (GEMM). Thus, one of the critical features of machine-learning-specific accelerators such as NVIDIA Tensor Cores, AMD Matrix Cores, and Google TPUs is the support of mixed-precision enabled GEMM. For DNN models, lower-precision FP data formats and computation offer acceptable correctness but significant performance, area, and memory footprint improvement. While promising, the mixed-precision computation on error resilience remains unexplored. To this end, we develop a fault injection framework that systematically injects fault into the mixed-precision computation results. We investigate how the faults affect the accuracy of machine learning applications. Based on the characteristics of error resilience, we offer lightweight error detection and correction solutions that significantly improve the overall model accuracy by 75% if the models experience hardware faults. The solutions can be efficiently integrated into the accelerator's pipelines.

Fang, Bo↗

Improved Localization Precision and Angular Resolution of a Cylindrical, Time-Encoded Imaging System From Adaptive Detector Movements

To the first order, the localization precision and angular resolution of a cylindrical, time-encoded imaging (c-TEI) system is governed by the geometry of the system. Improving either measure requires increasing the mask radius or decreasing the detector diameter, both of which are undesirable. Here, we propose an alternative option of repositioning the detector within the mask to increase the detector-to-mask distance in the direction of a source, thereby improving the localization precision and angular resolution in that direction. Since the detector-to-mask distance only increases for a small portion of the field of view (FOV), we propose implementing adaptive imaging where one leverages data collected during the measurement to optimize the system configuration. This article utilizes both simulations and experiments to set upper bounds on the potential gain from adaptive detector movements for one and two sources in the FOV. When only one source is present, adaptive detector movements can improve the localization precision and angular resolution by 20% for a source at 90 cm and by 32% for a far-field source. When two sources are present, adaptive detector movements can improve localization precision and angular resolution by up to 50% for sources that are ~10° apart (90 cm from the system). We experimentally verify these results through maximum likelihood estimation of the source position(s) and image reconstruction of point sources that are close together. As a demonstration of an adaptive imaging algorithm, we image a complex arrangement of special nuclear material at the Zero Power Physics Reactor facility at Idaho National Laboratory.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Rounding Error Analysis of Mixed Precision Block Householder QR Algorithms

Although mixed precision arithmetic has recently garnered interest for training dense neural networks, many other applications could benefit from the speedups and lower storage cost if applied appropriately. The growing interest in employing mixed precision computations motivates the need for rounding error analysis that properly handles behavior from mixed precision arithmetic. We develop mixed precision variants of existing Householder QR algorithms and show error analyses supported by numerical experiments.

97 MATHEMATICS AND COMPUTING↗

High-Performance GMRES Mixed-Precision (HPG-MxP) Benchmark

SAND2024-08539O The High Performance GMRES Mixed-Precision (HPG-MxP) is a benchmark for ranking high-performance supercomputers, allowing use of mixed-precision. Similar to HPCG benchmark, it is designed to profile the computers' capabilities to perform the computational and communication tasks that are commonly found in important classes of real-world applications. At the same time, like HPL-MxP benchmark, it allows the use of mixed-precision arithmetic, while ensuring the double-precision accuracy of the computed solution. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

SciDAC↗