Search NASA⌕ Search

SEARCH · Search NASA

Results for “Proficiency testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Integrated Data Collection Analysis (IDCA) Program - RDX Type II Class 5 Standard, Data Set 1

This document describes the results of the first reference sample material—RDX Type II Class 5—examined in the proficiency study for small-scale safety and thermal (SSST) testing of explosive materials for the Integrated Data Collection Analysis (IDCA) Program. The IDCA program is conducting proficiency testing on homemade explosives (HMEs). The reference sample materials are being studied to establish the accuracy of traditional explosives safety testing for each performing laboratory. These results will be used for comparison to results from testing HMEs. This effort, funded by the Department of Homeland Security (DHS), ultimately will put the issues of safe handling of these materials in perspective with standard military explosives. The results of the study will add SSST testing results for a broad suite of different HMEs to the literature, potentially suggest new guidelines and methods for HME testing, and possibly establish what are the needed accuracies in SSST testing to develop safe handling practices. Described here are the results for impact, friction, electrostatic discharge, and scanning calorimetry analysis of a reference sample of RDX Type II Class 5. The results from each participating testing laboratory are compared using identical test material and preparation methods wherever possible. Note, however, the test procedures differ among the laboratories. These results are then compared to historical data from various sources. The performers involved are Lawrence Livermore National Laboratory (LLNL), Los Alamos National Laboratory (LANL), Air Force Research Laboratory/ RXQL (AFRL), Indian Head Division, Naval Surface Warfare Center, (IHD-NSWC), and Sandia National Laboratories (SNL). These tests are conducted as a proficiency study in order to establish some consistency in test protocols, procedures, and experiments and to understand how to compare results when test protocols are not identical.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Statistical scoring procedures applicable to laboratory performance evaluation

Two statistical scoring procedures based on p-values have been developed to evaluate the overall performance of analytical laboratories performing environmental measurements. The overall scores of bias and standing are used to determine how consistently a laboratory is able to measure the true (unknown) value correctly over time. The overall scores of precision and standing are used to determine how well a laboratory is able to reproduce its measurements in the long run. Criteria are established for qualitatively labeling measurements as Acceptable, Warning, and Not Acceptable and for identifying areas where laboratories should re-evaluate their measurement procedures. These statistical scoring procedures are applied to two real environmental data sets.

97 MATHEMATICS AND COMPUTING↗

Integrated Data Collection Analysis (IDCA) Program — RDX Standard Data Sets

The Integrated Data Collection Analysis (IDCA) program is conducting a proficiency study for Small- Scale Safety and Thermal (SSST) testing of homemade explosives (HMEs). Described here are the results for impact, friction, electrostatic discharge, and differential scanning calorimetry analysis of the RDX Type II Class 5 standard, for a third and fourth time in the Proficiency Test and averaged with the analysis results from the first and second time. The results, from averaging all four sets (1, 2, 3 and 4) of data suggest a material to have slightly more impact sensitivity, more BAM friction sensitivity, less ABL friction sensitivity, similar ESD sensitivity, and same DSC sensitivity, compared to the results from Set 1, which was used previously as the values for the RDX standard in IDCA Analysis Reports.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Integrated Data Collection Analysis (IDCA) program--KClO 4 /Dodecane Mixture

The Integrated Data Collection Analysis (IDCA) program is conducting a proficiency study for Small- Scale Safety and Thermal (SSST) testing of homemade explosives (HMEs). Described here are the results for impact, friction, electrostatic discharge, and differential scanning calorimetry analysis of a mixture of KClO 4 and dodecane—KClO 4 /dodecane mixture. This material was selected because of the challenge of performing SSST testing of a mixture of solid and liquid materials. The mixture was found to: 1) be less sensitive to impact than RDX, and PETN, 2) less sensitive to friction than RDX and PETN, and 3) less sensitive to spark than RDX and PETN. The thermal analysis showed little or no exothermic features suggesting that the dodecane volatilized at low temperatures. A prominent endothermic feature was observed and assigned to a phase transition of KClO 4 . This effort, funded by the Department of Homeland Security (DHS), ultimately will put the issues of safe handling of these materials in perspective with standard military explosives. The study is adding SSST testing results for a broad suite of different HMEs to the literature. Ultimately the study has the potential to suggest new guidelines and methods and possibly establish the SSST testing accuracies needed to develop safe handling practices for HMEs. Each participating testing laboratory uses identical test materials and preparation methods wherever possible. Note, however, the test procedures differ among the laboratories. The results are compared among the laboratories and then compared to historical data from various sources. The testing performers involved for the KClO 4 /dodecane mixture are Lawrence Livermore National Laboratory (LLNL), Los Alamos National Laboratory (LANL), Indian Head Division, Naval Surface Warfare Center, (NSWC IHD), and Air Force Research Laboratory (AFRL/RXQL). These tests are conducted as a proficiency study in order to establish some consistency in test protocols, procedures, and experiments and to understand how to compare results when these testing variables cannot be made consistent.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Integrated Data Collection Analysis (IDCA) Program - KClO 4 /Carbon Mixture

The Integrated Data Collection Analysis (IDCA) program is conducting a proficiency study for Small- Scale Safety and Thermal (SSST) testing of homemade explosives (HMEs). Described here are the results for impact, friction, electrostatic discharge, and differential scanning calorimetry analysis of a mixture of KClO 4 and activated carbon—KClO 4 /C mixture. This material was selected because of the challenge of performing SSST testing of a mixture of two solids. The mixture was found to be insensitive to impact, friction, and thermal stimulus, and somewhat sensitive to spark discharge. This effort, funded by the Department of Homeland Security (DHS), ultimately will put the issues of safe handling of these materials in perspective with standard military explosives. The study is adding SSST testing results for a broad suite of different HMEs to the literature. Ultimately the study has the potential to suggest new guidelines and methods and possibly establish the SSST testing accuracies needed to develop safe handling practices for HMEs. Each participating testing laboratory uses identical test materials and preparation methods wherever possible. Note, however, the test procedures differ among the laboratories. The results are compared among the laboratories and then compared to historical data from various sources. The testing performers involved for the KClO 4 /carbon mixture are Lawrence Livermore National Laboratory (LLNL), Los Alamos National Laboratory (LANL), Indian Head Division, Naval Surface Warfare Center, (NSWC IHD), and Air Force Research Laboratory (AFRL/RXQL). These tests are conducted as a proficiency study in order to establish some consistency in test protocols, procedures, and experiments and to understand how to compare results when these testing variables cannot be made consistent.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Integrated Data Collection Analysis (IDCA) Program - KClO 3 /Dodecane Mixture

The Integrated Data Collection Analysis (IDCA) program is conducting a proficiency study for Small-Scale Safety and Thermal (SSST) testing of homemade explosives (HMEs). Described here are the results for impact, friction, electrostatic discharge, and differential scanning calorimetry analysis of a mixture of KClO 3 and dodecane—KClO 3 /dodecane mixture. This material was selected because of the challenge of performing SSST testing of a mixture of solid and liquid materials. The mixture was found to: 1) be more sensitive to impact than RDX, and PETN, 2) less sensitive to friction than PETN, and 3) less sensitive to spark than RDX. The thermal analysis showed little or no exothermic features suggesting that the dodecane volatilized at low temperatures. A prominent endothermic feature was observed assigned to melting of KClO 3 . This effort, funded by the Department of Homeland Security (DHS), ultimately will put the issues of safe handling of these materials in perspective with standard military explosives. The study is adding SSST testing results for a broad suite of different HMEs to the literature. Ultimately the study has the potential to suggest new guidelines and methods and possibly establish the SSST testing accuracies needed to develop safe handling practices for HMEs. Each participating testing laboratory uses identical test materials and preparation methods wherever possible. Note, however, the test procedures differ among the laboratories. The results are compared among the laboratories and then compared to historical data from various sources. The testing performers involved for the KClO 3 /dodecane mixture are Lawrence Livermore National Laboratory (LLNL), Los Alamos National Laboratory (LANL), and Indian Head Division, Naval Surface Warfare Center, (NSWC IHD). These tests are conducted as a proficiency study in order to establish some consistency in test protocols, procedures, and experiments and to understand how to compare results when these things cannot be made consistent.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

TH-C-17A-01: Imaging Sensor Comparison for Real-Time Cherenkov Signal Detection From Tissue for Treatment Verification

Purpose: To identify the optimum imaging sensor for a clinical system that would provide real-time imaging of the surface beam profile on patients as novel visual information to radiation therapy technologists, and more rapidly collect clinical data for large-scale studies of Cherenkov applications in radiotherapy. Methods: Four camera types, CMOS, CCD, ICCD and EMICCD, were tested to determine proficiency in the detection of Cherenkov signal in the clinical radiotherapy setting, and subsequent maximum supportable frame rate. Where possible, time-gating between the trigger signal from the LINAC and the intensifiers was implemented to detect signal with room lighting conditions comparable to patient treatment scenarios. A solid water phantom was imaged by the EM-ICCD and ICCD to evaluate the minimum number of accumulations-on-chip required for adequate Cherenkov detection, defined as >200% electron counts per pixel over background signal. Additionally, an ICCD and EM-ICCD were used clinically to image patients undergoing whole-breast radiation therapy, to understand the impact of the resolution limitation of the EM-ICCD. Results: The intensifier-coupled cameras performed best at imaging Cherenkov signal, even with room lights on, which is essential for patient comfort. The tested EM-ICCD was able to support single-shot imaging and frame rates of 30 fps, however, the current maximum resolution of 512 × 512 pixels was restricting. The ICCD used in current clinical trials was limited to 4.7 fps at a 1024 × 1024 resolution. An intensifier with higher quantum efficiency at the entrance photocathode in the red wavelengths (30% QE vs current 7%) promises 16 fps at the same resolution at lower cost than the EM-ICCD. Conclusion: The ICCD with the better red wavelength QE intensifier was determined to be the best suited commercial-off-the-shelf camera to detect real-time Cherenkov signal and provide the best potential for real-time display of radiation dose on the skin during treatment. Funding is from grants from the NIH numbers R01CA109558 and R21EB017559.

60 APPLIED LIFE SCIENCES↗

Grout testing to support tank closure at the Savannah River Site - 15370

Final operational closure of the Savannah River Site (SRS) waste tanks is performed by filling the voids inside the tanks with a series of tailored grout formulas thereby stabilizing the remaining residuals. These tailored grout formulas were each developed to meet the demands of the closure process. The needs identified for the closure process include (1) a flowable, self-consolidating, reducing grout for tank fill, (2) a highly flowable grout capable of filling the 7-1/4 kilometers (4-1/2 miles) of 5-centimeter (2-inch) diameter cooling coils inside the tank, and (3) a highly flowable grout capable of filling equipment remaining in the tank. The specific characteristics of each of the grout formulations were tested to ensure they would function as required during implementation. Performance testing was also done on some of the grout formulations to confirm mix effectiveness and improve worker handling proficiency and conducted additional testing on the bulk fill grout to expand the placement capabilities of the grout. This paper focuses on the evolution of the closure process' identified needs, formulation development, and the subsequent testing of the tailored grout formulations utilized in the past tank closure processes at SRS. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

An Aerial Radiological Survey of Selected Areas of Area 18 - Nevada Test Site

As part of the proficiency training for the Radiological Mapping mission of the Aerial Measuring System (AMS), a survey team from the Remote Sensing Laboratory-Nellis (RSL-Nellis) conducted an aerial radiological survey of selected areas of Area 18 of the Nevada Test Site (NTS) for the purpose of mapping man-made radiation deposited as a result of the Johnnie Boy and Little Feller I tests. The survey area centered over the Johnnie Boy ground zero but also included the ground zero and deposition area of the Little Feller I test, approximately 7,000 feet (2133 meters) southeast of the Johnnie Boy site. The survey was conducted in one flight. The completed survey covered a total of 4.0 square miles. The flight lines (with the turns) over the surveyed areas are presented in Figure 1. One 2.5-hour-long flight was performed at an altitude of 100 ft above ground level (AGL) with 200 foot flight-line spacing. A test-line flight was conducted near the Desert Rock Airstrip to ensure quality control of the data. The test line is not shown in Figure 1. However, Figure 1 does include the flight lines for a ''perimeter'' flight. The path traced by the helicopter flying over distinct roads within the survey area can be used to overlay the survey data on a base map or image. The flight survey lines were flown in an east-west orientation perpendicular to the deposition patterns for both sites. This technique provides better spatial resolution when contouring the data. The data were collected by the AMS data acquisition system (REDAR V) using an array of twelve 2-inch x 4-inch x 16-inch sodium iodide (NaI) detectors flown on-board a twin-engine Bell 412 helicopter. Data, in the form of gamma energy spectra, were collected every second over the course of the survey and were geo-referenced using a differential Global Positioning System. Spectral data allows the system to distinguish between ordinary fluctuations in natural background radiation levels and the signature produced by man-made radioisotopes. Spectral data can also identify specific radioactive isotopes. Based on the results of the RSL NTS 1994 surveys, this area was chosen for a resurvey to improve the spatial resolution of the reported depositions for the Johnnie Boy and Little Feller I events. In addition, the survey was expected to confirm the absence of detectable concentrations of Americium-241 (Am-241) at the Johnnie Boy site and attempt to confirm the presence of Uranium-235 (U-235).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Integrated Data Collection Analysis (IDCA) Program - NaClO 3 /Icing Sugar

The Integrated Data Collection Analysis (IDCA) program is conducting a proficiency study for Small- Scale Safety and Thermal (SSST) testing of homemade explosives (HMEs). Described here are the results for impact, friction, electrostatic discharge, and differential scanning calorimetry analysis of a mixture of NaClO 3 and icing sugar—NaClO 3 /icing sugar mixture. The mixture was found to: be more sensitive than RDX but less sensitive than PETN in impact testing (180-grit sandpaper); be more sensitive than RDX and about the same sensitivity as PETN in BAM fiction testing; be less sensitive than RDX and PETN except for one participant found the mixture more sensitive than PETN in ABL ESD testing; and to have one to three exothermic features with the lowest temperature event occurring at ~ 160°C always observed in thermal testing. Variations in testing parameters also affected the sensitivity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Integrated Data Collection Analysis (IDCA) Program — Ammonium Nitrate

The Integrated Data Collection Analysis (IDCA) program is conducting a proficiency study for Small- Scale Safety and Thermal (SSST) testing of homemade explosives (HMEs). Described here are the results for impact, friction, electrostatic discharge, and differential scanning calorimetry analysis of ammonium nitrate (AN). AN was tested, in most cases, as both received from manufacturer and dried/sieved. The participants found the AN to be: 1) insensitive in Type 12A impact testing (although with a wide range of values), 2) completely insensitive in BAM friction testing, 3) less sensitive than the RDX standard in ABL friction testing, 4) less sensitive than RDX in ABL ESD testing, and 5) less sensitive than RDX and PETN in DSC thermal analyses.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Side effects of antimotion sickness drugs

The effects on operational proficiency of the antimotion sickness drugs scopolamine, promethazine and d-amphetamine are tested using a computerized pursuit meter. Proficiency is not significantly affected by oral doses of 0.25 mg or 0.50 mg scopolamine but is descreased by oral or I.M. doses of 25 mg promethazine. The performance decrement associated with 25 mg oral promethazine is prevented when combined with 10 mg oral d-amphetamine. The combination of 25 mg I.M. promethazine, 25 mg oral promethazine and 10 mg d-amphetamine produces less performance decrement than oral or I.M. doses of promethazine alone, though more performance decrement than a placebo. I.M. promethazine is adsorbed slowly and consequently may provoke drowsiness.

Wood, C. D.↗

Integrated Data Collection Analysis (IDCA) Program — Bullseye ® Smokeless Powder

The Integrated Data Collection Analysis (IDCA) program is conducting a proficiency study for Small- Scale Safety and Thermal (SSST) testing of homemade explosives (HMEs). Described here are the results for impact, friction, electrostatic discharge, and differential scanning calorimetry analysis of Bullseye ® smokeless powder (Gunpowder). The participants found the Gunpowder: 1) to have a range of sensitivity to impact, from less than RDX to almost as sensitive as PETN, 2) to be moderately sensitive to BAM and ABL friction, 3) have a range for ESD, from insensitive to more sensitive than PETN, and 4) to have thermal sensitivity about the same as PETN and RDX.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Integrated Data Analysis (IDCA) Program - PETN Class 4 Standard

The Integrated Data Collection Analysis (IDCA) program is conducting a proficiency study for Small- Scale Safety and Thermal (SSST) testing of homemade explosives (HMEs). Described here are the results for impact, friction, electrostatic discharge, and differential scanning calorimetry analysis of PETN Class 4. The PETN was found to have: 1) an impact sensitivity (DH 50 ) range of 6 to 12 cm, 2) a BAM friction sensitivity (F 50 ) range 7 to 11 kg, TIL (0/10) of 3.7 to 7.2 kg, 3) a ABL friction sensitivity threshold of 5 or less psig at 8 fps, 4) an ABL ESD sensitivity threshold of 0.031 to 0.326 j/g, and 5) a thermal sensitivity of an endothermic feature with T min = ~ 141 °C, and a exothermic feature with a T max = ~205°C.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

ABL and BAM Friction Analysis Comparison

Here, the Integrated Data Collection Analysis (IDCA) program has conducted a proficiency study for Small-Scale Safety and Thermal (SSST) testing of homemade explosives (HMEs). Described here is a comparison of the Alleghany Ballistic Laboratory (ABL) friction data and Bundesanstalt fur Materialforschung und -prufung (BAM) friction data for 19 HEM and military standard explosives.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Integrated Data Collection Analysis (IDCA) Program — KClO 3 /Icing Sugar (-100 mesh) Mixture

The Integrated Data Collection Analysis (IDCA) program is conducting a proficiency study for Small-Scale Safety and Thermal (SSST) testing of homemade explosives (HMEs). Described here are the results for impact, friction, electrostatic discharge, and scanning calorimetry analysis of a mixture of KClO 3 sized through a 100-mesh sieve mixed with icing sugar, also sized through a 100-mesh sieve—KClO 3 /icing sugar (-100) mixture. This material was selected because of the challenge of performing SSST testing of a mixture of two solid materials. The mixture was found to be: 1) more sensitive to impact than RDX, with sensitivity similar to PETN, 2) the same or more sensitive to friction than PETN, and 3) less sensitive to spark than RDX. The analysis showed that the mixture has thermally stability similar to RDX and is perhaps more energetic upon decomposition but variable results indicate sampling issues.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗