Search NASA⌕ Search

SEARCH · Search NASA

Results for “Reference Standards”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

The effect of sample holder material on ion mobility spectrometry reproducibility

When a positive detection of a narcotic occurs during the search of a vessel, a decision has to be made whether further intensive search is warranted. This decision is based in part on the results of a second sample collected from the same area. Therefore, the reproducibility of both sampling and instrumental analysis is critical in terms of justifying an in depth search. As reported at the 2nd Annual IMS Conference in Quebec City, the U.S. Coast Guard has determined that when paper is utilized as the sample desorption medium for the Barringer IONSCAN, the analytical results using standard reference samples are reproducible. A study was conducted utilizing papers of varying pore sizes and comparing their performance as a desorption material relative to the standard Barringer 50 micron Teflon. Nominal pore sizes ranged from 30 microns down to 2 microns. Results indicate that there is some peak instability in the first two to three windows during the analysis. The severity of the instability was observed to increase as the pore size of the paper is decreased. However, the observed peak instability does not create a situation that results in a decreased reliability or reproducibility in the analytical result.

Jadamec, J. Richard↗

Preparation of large-particle-size monodisperse latexes in space

Results are reported of latex sphere polymerization experiments performed on two flights of the Columbia and three flights of the Challenger. The trials were carried out because polymerization of the spheres in space avoids coagulation, nucleation of a new crop of particles, and excessive stirring requirements, and allows growth of spheres larger than 4 microns diam. The Monodisperse Latex Reactor (MLR) held four stirred 100 cc sealed stainless steel cylindrical containers. The mixtures were monitored for the conversion times, volume decreases as spheres formed and the mixture temperature. The spheres were grown from 0.19 micron seeds. Details of the flight preparation efforts are outlined. In flights which did not experience mechanical malfunctions spheres 3-30 microns diam were grown that had noticeably lower size variations than did the ground-based control particles. The 10 micron diam spheres grown on STS-6 were accepted as standard reference material by the NBS and became the first products made in space to be commercially sold on earth; the 30 micron spheres also became NBS standards. The experiments confirmed all projected benefits of producing the spheres in space, as well as provided the opportunity to grow more larger offsize spheres by finishing the growths on earth.

Vanderhoff, J. W.↗

Rotating pressure measurement system using an on board calibration standard

A computer-controlled multichannel pressure measurement system was developed to acquire detailed flow field measurements on board the Large Low Speed Centrifugal Compressor Research Facility at the NASA Lewis Research Center. A pneumatic slip ring seal assembly is used to transfer calibration pressures to a reference standard transducer on board the compressor rotor in order to measure very low differential pressures with the high accuracy required. A unique data acquisition system was designed and built to convert the analog signal from the reference transducer to the variable frequency required by the multichannel pressure measurement system and also to provide an output for temperature control of the reference transducer. The system also monitors changes in test cell barometric pressure and rotating seal leakage and provides an on screen warning to the operator if limits are exceeded. The methods used for the selection and testing of the the reference transducer are discussed, and the data acquisition system hardware and software design are described. The calculated and experimental data for the system measurement accuracy are also presented.

Senyitko, Richard G.↗

Results of the 1981 NASA/JPL balloon flight solar cell calibration program

The calibration of the direct conversion of solar energy through use of solar cells at high altitudes by balloon flight is reported. Twenty seven modules were carried to an altitude of 35.4 kilometers. Silicon cells are stable for long periods of time and can be used as standards. It is demonstrated that the cell mounting cavity may be either black or white with equal validity in setting solar simulators. The calibrated cells can be used as reference standards in simulator testing of cells and arrays.

Seaman, C. H.↗

Thermodynamic Data For 50 Chemical Elements

Report presents data on thermo-dynamic properties of 50 chemical elements, isotope (deuterium) of one of elements, and electron gas, all in standard reference states. Data tabulated as functions of temperature; also given in form of least-squares-fit coefficients of two functional forms for heat capacities at constant pressure in standard states, with constants of integration for enthalpy and entropy.

Mcbride, Bonnie J.↗

Lunar Regolith Simulant Materials: Recommendations for Standardization, Production, and Usage

Experience gained during the Apollo program demonstrated the need for extensive testing of surface systems in relevant environments, including regolith materials similar to those encountered on the lunar surface. As NASA embarks on a return to the Moon, it is clear that the current lunar sample inventory is not only insufficient to support lunar surface technology and system development, but its scientific value is too great to be consumed by destructive studies. Every effort must be made to utilize standard simulant materials, which will allow developers to reduce the cost, development, and operational risks to surface systems. The Lunar Regolith Simulant Materials Workshop held in Huntsville, AL, on January 24 26, 2005, identified the need for widely accepted standard reference lunar simulant materials to perform research and development of technologies required for lunar operations. The workshop also established a need for a common, traceable, and repeatable process regarding the standardization, characterization, and distribution of lunar simulants. This document presents recommendations for the standardization, production and usage of lunar regolith simulant materials.

Sibille, L.↗

Verification of technical elements of the advanced spacecraft based upon the CCSDS recommendation

We are going to meet the era when advanced spacecraft such as space stations are developed and operated. The current system of the satellite operations control will need to undergo many changes. We consider that the future system will require the following functions: the function for interchanging data between international agencies, processing the various kinds of space data, and distributing data as many unspecified users require. However, we have to solve the following problems in order to satisfy these requirements: the problem of standardization of space data communication protocol, establishment of multimedia data management method, and standardization of the user interface. This paper describes three techniques to solve the above mentioned problems. That is, standardization of the data communication protocol between space and ground by AOS (Advanced Orbiting System) protocol of CCSDS (Consultative Committee for Space Data Systems) Recommendation, management of multimedia data by catalog reference, standardization of user interface by SFDU(Standard Formatted Data Unit) of CCSDS Recommendation.

Hara, Hideo↗

Controlled-Shape, Ultrasonic-Angle-Beam Standard Reflector

New ultrasonic angle-beam standard reflector uses impression of letter "l" steel-die stamp. NDE techniques and standard reflector apply to use of pulse-echo-type ultrasonic equipment for inspection of wrought metals including forgings and forging stock; rolled billet, bar or plate; and extruded bar, tube, and shapes. "l" reference standard reflector affords advantages of easy insertion in inspected item using common hand-tools and greatly reduced implementation time through elimination of machining operations.

Berry, J., Robertf.↗

Performance comparison of Malvern instruments laser diffraction drop size analyzer

The performance of ten laser diffraction particle sizing instruments (Malvern models 2200 and 2600) has been evaluated using a synthetic particle size reference standard in a round-robin test at nine independent laboratories. A calibration reticle consisting of a two-dimensional array of opaque, circular particle images photoetched in chrome thin film deposited on a glass substrate was used as the reference. Mean diameters (e.g., D32) for the reticle measured by the ten unmodified instruments varied by 27 percent. In contrast, data from six instruments with individually calibrated photodetector correction factors demonstrated much better agreement and were within 2.6 percent of the actual reticle properties.

Hirleman, E. D.↗

Numeric data distribution: The vital role of data exchange in today's world

The major aim of the NIST standard Reference Data Program (SRD) is to provide critically evaluated numeric data to the scientific and technical community in a convenient and accessible form. A second aim of the program is to provide feedback into the experimental and theoretical programs to help raise the general standards of measurement. By communicating the experience gained in evaluating the world output of data in the physical sciences, NIST/SRD helps to advance the level of experimental techniques and improve the reliability of physical measurements.

Chase, Malcolm W.↗

International comparison of radiometers - Techniques and results.

Description of an international comparison of radiometers made on May 10 through 14, 1971, with 24 instruments, each one representing the calibration standard of a different country or a major laboratory. All were pyranometers, viewing the sun and sky, thus bypassing the conventional method of transferring the standard from Angstrom pyrheliometers. This is the first time that pyranometers from all around the globe have been brought together in order to verify the scale on which to report solar radiation data. A highly accurate data collection system measured simultaneously the output of each instrument and that of a reference standard at 20-sec intervals. Over 300,000 radiometric signals were recorded under varying atmospheric conditions, as well as data on turbidity, temperature, and other relevant parameters. Computer programs were developed for overnight analysis of the data and distribution to participants on the following day. Among major findings are that instruments of different types and independent calibration such as those of Eppley, U. S. A., World Radiation Center, Switzerland, and Melbourne, Australia, show better agreement than anticipated, that certain national standards have to be revised by as much as 16% and that the cosine factor is highly dependent on the type of instrument.

Thekaekara, M. P.↗

Solar cell calibration facility validation of balloon flight data: A comparison of shuttle and balloon flight results

The Solar Cell Calibration Facility (SCCF) experiment was designed and built to evaluate the effect of the Earth's upper atmosphere on the calibration of solar cell standards. During execution of the experiment, a collection of carefully selected solar cells was flown on the shuttle, and reflown on a high-altitude balloon, then their outputs were compared. After correction to standard temperature and intensity values of 28 C and an Earth-Sun distance of 1 AU, the solar cell outputs during the two flights were found to be identical. The conclusion is therefore that the high-altitude balloon flights are very good vehicles for calibrating solar cells for use as space flight reference standards.

Anspaugh, B. E.↗

Computation of diffuse sky irradiance from multidirectional radiance measurements

Accurate determination of the diffuse solar spectral irradiance directly above the land surface is important in characterizing the reflectance properties of these surfaces, especially vegetation canopies. This determination is also needed to infer the net radiation budget of the earth-atmosphere system above these surfaces. An algorithm is developed here for the computation of hemispheric diffuse irradiance using the measurements from an instrument called PARABOLA, which rapidly measures upwelling and downwelling radiances in three selected wavelength bands. The validity of the algorithm is established from simulations. The standard reference data set of diffuse radiances of Dave (1978), obtained by solving the radiative transfer equation numerically for realistic atmospheric models, is used to simulate PARABOLA radiances. Hemispheric diffuse irradiance is estimated from a subset of simulated radiances by using the algorithm described. The algorithm is validated by comparing the estimated diffuse irradiance with the true diffuse irradiance of the standard data set. The validations include sensitivity studies for two wavelength bands (visible, 0.65-0.67 micron; near infrared, 0.81-0.84 micron), different atmospheric conditions, solar elevations, and surface reflectances. In most cases the hemispheric diffuse irradiance computed from simulated PARABOLA radiances and the true irradiance obtained from radiative transfer calculations agree within 1-2 percent. This technique can be applied to other sampling instruments designed to estimate hemispheric diffuse sky irradiance.

Ahmad, Suraiya P.↗

Overview of GSICS visible calibration methods.

Global Space-based Inter-Calibration System (GSICS) is an international collaborative effort initiated in 2005 by the World Meteorological Organization (WMO) and the Coordination Group for Meteorological Satellites (CGMS) to 1-monitor, 2-improve and 3-harmonize the quality of observations from operational weather and environmental satellites of the Global Observing System (GOS). GSICS aims at ensuring consistent accuracy among space-based observations worldwide for climate monitoring, weather forecasting, and environmental applications by 1-monitoring instrument performance, 2-operational inter-calibration of satellite instruments, 3-radiometrically scaling observations to absolute reference standards, 4-recalibration of archived datasets. Although many of the GSIC visible inter-calibration methods are based on medium pixel-level imagers such as MODIS, VIIRS, AVHRR, and geostationary sensors, the methods are applicable to high spatial resolution imagery such as Landsat. For sensor inter-calibration efforts, coincident ray-matched reflectance pairs are used to transfer the calibration from the reference to the target instrument. Spectral band adjustment factors (SBAF) are applied to account for any spectral band differences. For sensor stability monitoring, PICS, deep convective cloud (DCC) and polar ice Earth viewed targets are utilized. GSICS uses the moon for stability monitoring by using the GSICS Implementation of the USGS Robotic Lunar Observatory (ROLO) model (GIRO). GSICS is looking forward to the launch of CLARREO on the international space station (ISS) in 2023. The CLARREO hyperspectral reflective solar band (RSB) sensor will establish an absolute calibration reference in space, which will characterize invariant targets and will inter-calibrate concurrent sensors. Examples of these calibration methods will be presented at the workshop.

Visible calibration methods↗

Considerations for Qualifying Reliable Eddy Current Array Technique for Detection of Backwall Cracks

A reliable nondestructive evaluation (NDE) technique provides minimum 90% probability of detection(POD) with 95% confidence for detection of cracklike flaws of a qualified size. In this case, the flaws are on backside of material. Eddy current array (ECA) probe or a single sensor eddy current probe in c-scanning mode is used for the flaw detection. Here, two geometries are considered for the test specimens. The two geometries are, a flat plate, and tube or pipe. The probe is assumed to be on outer diameter (OD)surface and the flaw is assumed to be at the inner diameter (ID) surface for tube inspection. The flaw and probe are on opposite side of wall thickness for inspection of plate material. The application may be used for acreage inspection or just for inspection of butt weld and heat affected zone (HAZ) in a tube, cylinder, or plate. The proposed approach is based on developing an instrument standardization or calibration procedure. Decision threshold of inspection procedure is determined using empirical qualification and noise data. The work explores essential parameters that are required to meet certain conditions to ensure reliable flaw detection. Physics-based simulation of eddy current array flaw detection is used to understand effect of essential parameters on signal response (amplitude and phase),and therefore flaw detectability. Simulation data is used to justify choice of calibration reference standard requirements and the qualification approach. An ECA technique qualification model is provided. The paper gives brief description of tasks to be completed for qualifying ECA technique for reliable detection of cracklike flaws.

Eddy current array inspection, nondestructive eval↗

Status of emerging standards for removable computer storage media and related contributions of NIST

Standards for removable computer storage media are needed so that users may reliably interchange data both within and among various computer installations. Furthermore, media interchange standards support competition in industry and prevent sole-source lock-in. NIST participates in magnetic tape and optical disk standards development through Technical Committees X3B5, Digital Magnetic Tapes, X3B11, Optical Digital Data Disk, and the Joint Technical Commission on Data Permanence. NIST also participates in other relevant national and international standards committees for removable computer storage media. Industry standards for digital magnetic tapes require the use of Standard Reference Materials (SRM's) developed and maintained by NIST. In addition, NIST has been studying care and handling procedures required for digital magnetic tapes. NIST has developed a methodology for determining the life expectancy of optical disks. NIST is developing care and handling procedures for optical digital data disks and is involved in a program to investigate error reporting capabilities of optical disk drives. This presentation reflects the status of emerging magnetic tape and optical disk standards, as well as NIST's contributions in support of these standards.

Podio, Fernando L.↗

Our Sun IV: The Standard Model and Helioseismology: Consequences of Uncertainties in Input Physics and in Observed Solar Parameters

Helioseismic frequency observations provide an extremely accurate window into the solar interior; frequencies from the Michaelson Doppler Imager (MDI) on the Solar and Heliospheric Observatory (SOHO) spacecraft, enable the adiabatic sound speed and adiabatic index to be inferred with an accuracy of a few parts in 10(exp 4) and the density with an accuracy of a few parts in 10(exp 3). This has become a Serious challenge to theoretical models of the Sun. Therefore, we have undertaken a self-consistent, systematic study of the sources of uncertainties in the standard solar models. We found that the largest effect on the interior structure arises from the observational uncertainties in the photospheric abundances of the elements, which affect the sound speed profile at the level of 3 parts in 10(exp 3). The estimated 4% uncertainty in the OPAL opacities could lead to effects of 1 part in 10(exp 3); the approximately 5%, uncertainty in the basic pp nuclear reaction rate would have a similar effect, as would uncertainties of approximately 15% in the diffusion constants for the gravitational settling of helium. The approximately 50% uncertainties in diffusion constants for the heavier elements would have nearly as large an effect. Different observational methods for determining the solar radius yield results differing by as much as 7 parts in 10(exp 4); we found that this leads to uncertainties of a few parts in 10(exp 3) in the sound speed int the solar convective envelope, but has negligible effect on the interior. Our reference standard solar model yielded a convective envelope position of 0.7135 solar radius, in excellent agreement with the observed value of 0.713 +/- 0.001 solar radius and was significantly affected only by Z/X, the pp rate, and the uncertainties in helium diffusion constants. Our reference model also yielded envelope helium abundance of 0.2424, in good agreement with the approximate range of 0.24 to 0.25 inferred from helioseismic observations; only extreme Z/X values yielded envelope helium abundance outside this range. We found that other current uncertainties, namely, in the solar age and luminosity, in nuclear rates other than the pp reaction, in the low-temperature molecular opacities, and in the low-density equation of state, have no significant effect on the quantities that can be inferred from helioseismic observations. The predicted pre-main-sequence lithium depletion is uncertain by a factor of 2. The predicted neutrino capture rate is uncertain by approximately 30% for the Cl-27 experiment and by approximately 3% for Ga-71 experiments, while the B-8 neutrino flux is uncertain by approximately 30%.

Boothroyd, Arnold I.↗

Method and apparatus for measuring thermal conductivity of small, highly insulating specimens

A hot plate method and apparatus for the measurement of thermal conductivity combines the following capabilities: 1) measurements of very small specimens; 2) measurements of specimens with thermal conductivity on the same order of that as air; and, 3) the ability to use air as a reference material. Care is taken to ensure that the heat flow through the test specimen is essentially one-dimensional. No attempt is made to use heated guards to minimize the flow of heat from the hot plate to the surroundings. Results indicate that since large correction factors must be applied to account for guard imperfections when specimen dimensions are small, simply measuring and correcting for heat from the heater disc that does not flow into the specimen is preferable. The invention is a hot plate method capable of using air as a standard reference material for the steady-state measurement of the thermal conductivity of very small test samples having thermal conductivity on the order of air.

Miller, Robert A.↗