Search NASA⌕ Search

SEARCH · Search NASA

Results for “Return Temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Remote sensing volatile elements for new signatures from underground nuclear explosions

The detection of radioactive noble gas isotopes is one of the key tools in detecting underground nuclear explosions but other volatile elemental species may also migrate to the surface that have historically been overlooked. To investigate this possibility we have been studying which elements are most readily volatilized into air from solid materials (rocks, concrete, glass etc.) following short duration (60-120 sec) spot heating spanning a wide temperature range (100-2000°C). The widest possible range of elements (Li-U) were monitored during the experiments that produced some unexpected results with regards to the apparent atmospheric persistence of some volatilized elements long after heating had ceased and the sample had returned to room temperature. Results highlighting elemental volatility as a function of temperature from different materials will be presented along with examples illustrating the extended periods over which some elements remain detectable by real time atmospheric sampling.

Underground Nuclear Explosions, Volatile Elements,↗

Thermoelectric power generation in the core of a nuclear reactor

Thermoelectric energy converters offer a promising solution to generate electrical power using heat in the nuclear reactor core. Despite significant improvements in thermoelectric efficiency of nanostructured materials, the performance of these advanced materials has yet to be demonstrated in the harsh radiation environment of a reactor core. Herein, we demonstrate a thermoelectric generator (TEG) made from nanostructured bulk half-Heusler (HH) materials generating stable electrical power density > 1140 W/m 2 after 30 days in the MIT Nuclear Research Reactor under an unprecedented fast-neutron (>1 MeV) fluence of 1.5 × 10 20 n/cm 2 . Despite an initial degradation due to irradiation damage when operating under relatively low temperatures, our TEG showed a 20-fold increase in power output when operating under high temperature due to in-situ annealing and resulting thermoelectric property recovery. First-principles modeling indicates that a chemically disordered metallic phase was formed under irradiation at lower temperatures, resulting in a drastic degradation in thermoelectric properties, while at sufficiently high temperatures the system returned to the initial chemically ordered HH phase and the thermoelectric properties recovered. Transmission electron microscopy and electron diffraction demonstrated that the chemically disordered phase was formed upon ion irradiation, confirming the prediction from first-principles simulations. Furthermore, the results suggest that with proper control over the TEG operating temperatures, the nanostructured bulk TEGs could produce stable electrical power and operate indefinitely in the core of a nuclear reactor.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Unclonable RFID-based tag-seal for storage containers

We are using the DoD MIL-STD as our guide for microelectronics aging (MIL-STD 883J, Method 1016.2: Life/Reliability Characterization Tests). In that document they recommend aging at 3 temperatures between 200-300C, separated by at least 25C, with the supply voltage at the maximum recommended voltage for the devices at 125C (3.6V in our case). If that voltage causes excessive current or power then it can be reduced and the duration of the tests extended. The MIL-STD also recommends current limiting resistors in series with the supply. Since we don’t have much time and we may not have enough ovens and other equipment, two temperatures separated by at least 50C would be an acceptable backup plan. To ensure a safe range of conditions is used, we are executing 24-hour step tests. For these, we will apply the stress for 24 hours and then measure the device to make sure it wasn’t damaged. During the stress the PUFs should be exercised, but we don’t need to measure their response. Rather, at set intervals our devices should be returned to nominal temperature (under bias), and then measured. The MIL-STD puts these intervals at 4, 8, 16, 32, 64, 128, 256, 512 and 1000 hours, although the test can be stopped early if 75% of the devices have failed. A final recommendation per the MIL-STD is that at least 40 devices should be measured under each condition. Since we only have 25 parts, we will place 10 devices in each of two stress conditions.

25 ENERGY STORAGE↗

Evaluation of Canisterized Foams and Evaluation of Radiation Hardened Foams for D&D Activities

The introduction of polyurethane foams has previously been examined elsewhere within the DOE complex with regards to decontamination and decommissioning (D&D) activities, though its use has been prohibited as a result of excessive heat generation and flammability concerns per the safety basis. Should these foams be found compatible with respect to the facility safety basis requirements, D&D work involving large void containing structures such as gloveboxes could be eased through the fixation of residual contamination after decontamination efforts have concluded. To this end, SRNL embarked on a characterization of commercial epoxy foams to identify the characteristics that would be most important to safety basis requirements. Through SRNL’s efforts, the performance of commercial two-part epoxy foams was evaluated for their foaming characteristics, temperature profiles, loading capability with high-Z (high density) additives, and applicability for shielding gamma emission from isotopes including; Am-241, Cs-137, and Co-60. It was found that these foams are capable of encapsulation of a desired volume, though the ideal and experimental expansion coefficients were found to differ. While heat is generated during the reaction, no samples generated heat above 70 °C. Of the down–selected materials, heating was on the order of 40 °C for the flexible foam and 60 °C for the rigid foam. Both were found to return to room temperature after 20 minutes regardless of the volume of foam cast. It was also found that the direct introduction of high-Z additives were capable of attenuating 98% of Am-241 gamma signal, 16% of Cs-137 signal, and 9.5% of Co-60 signal at 1:1 loading capacities of total liquid constituent weight to additive weight. These efforts are currently being reviewed for the ASTM January 2017 subcommittee discussions to address the lack of test methods and standards regarding these materials with respect to D&D environments.

36 MATERIALS SCIENCE↗

TATB ratchet growth and hydrostatically-confined PBX 9502

The explosive TATB (1,3,5-triamino-2,4,6-trinitirobenzene) is formulated with various polymeric binders to create plastic-bonded explosives like PBX 9502 (95 wt% TATB and 5 wt% Kel-F binder). TATB crystals are graphitic and plate-like in nature and single crystals exhibit anisotropic thermal expansion where the direction normal to the platelet surface grows 10-20 times more than the in-plane platelet direction. Compactions of TATB, with and without binder, exhibit irreversible volume expansion, also known as ratchet growth, when thermal cycled to hot or cold temperatures. Specifically, when TATB-based compactions return to ambient after a temperature excursion away from room temperature, the volume of the specimen is slightly larger. Repeated thermal cycles can reduce the density by 1 to 2%. Axial confinement on a cylindrical specimen has previously been shown by us to suppress growth in the confining direction but then increase growth in the unconfined directions (likely due to creep effects). In the work presented here, PBX 9502 specimens were placed in cup assemblies where they were embedded in Sylgard (an incompressible silicon resin) to provide hydrostatic confinement when the assemblies were placed under different axial loads. The loaded cup assemblies were thermally cycled 10 times to hot and cold temperatures. Finally, results show that increasing the hydrostatic confining pressure causes a decrease in the PBX 9502 volume expansion that occurs.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Prototype energy models for data centers

Data centers in the United States consume about two percent of the nation’s electricity. Because heat gains from IT equipment drive cooling demand, data centers offer unique opportunities for energy savings. However, no prototype energy model for data centers is available in the suite of existing U.S. Department of Energy’s Commercial Prototype Building Models. Here we present the development of two new data center prototype models and their implementation in OpenStudio and EnergyPlus. The small-size data center model represents a computer room in a building served by computer room air conditioners (CRACs); while the large-sized model represents stand-alone data centers served by computer room air handlers (CRAHs) with a central chiller plant. For each data center model, two levels of IT equipment (ITE) load density were considered, to cover the wide range of IT power density of data centers: 40 and 100 W/ft 2 (430 and 1076 W/m 2 ) for the computer room, and 100 and 500 W/ft 2 (1076 and 5382 W/m 2 ) for the stand-alone data center. All other assumptions, such as building envelope, lighting, HVAC efficiencies and schedules, were based on the minimal requirements of ASHRAE Standard 90.1 at various vintages. We introduced a novel concept of supply and return air approach temperatures to capture the essential effects of non-uniform airflow and temperature distribution in data centers. The approach temperatures were pre-computed by computational fluid dynamics (CFD) simulations for various configurations of ITE loads and airflow containment management in data centers. A new feature was developed in EnergyPlus to implement the approach temperature method. A case study was conducted to demonstrate the use of the data center models. The two data center models cover all U.S. climate zones and can be used to evaluate energy saving measures for data centers, as well as to support development of data center energy efficiency codes and standards.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Application of Cryocoolers to a Vintage Dilution Refrigerator

A dilution refrigerator is required for 50mK detector operation of CDMS (Cryogenic Dark Matter Search). Besides shielding the dilution refrigerator itself, the liquid nitrogen shield and liquid helium bath in the refrigerator cool the detector cryostat heat shields and cool electronics, resulting in significant external heat loads at 80K and at 4K. An Oxford Instruments Kelvinox 400 has served this role for ten years but required daily transfers of liquid nitrogen and liquid helium. Complicating the cryogen supply is the location 800 meters below ground in an RF shielded, class 10000 clean room at Soudan, MN. Nitrogen and helium re-liquefiers using cryocoolers were installed outside the clean room and continuously condense room temperature gas and return the liquids to the dilution refrigerator through a transfer line. This paper will describe the design, installation, controls and performance of liquefaction systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Project Report: High Frequency Axion LDRD - A Multiport Approach to Thermal Noise and Scattering Parameter Simulation of Cryogenic Experiments

In this report, a simple algorithm for detailed system-level thermal noise analysis is developed, demonstrated, and verified. This method uses noise-wave theory and noise covariance matrices to cascade noise and scattering parameters of multiport devices at different temperatures. This method addresses the effects of return loss, multiport isolation/coupling, and static temperature differentials between components, and will work in cases where the noise temperature is at or near the quantum noise limit. An ideal multidevice network will first be demonstrated to show that this method’s results are consistent with the Friis cascade when component parameters such as return loss and isolation are ideal. Following the ideal multidevice example, a cryogenic experiment is conducted to demonstrate that the proposed simulation method is successful when real data are used.

42 ENGINEERING↗

Surface energy transport following relativistic laser-solid interaction

A planar Al target is excited by a 25 fs laser pulse focused to intensity up to 3x10{sup 18} W/cm{sup 2} in a {approx}1 {mu}m radius spot; subsequent heat propagation along the target surface, imaged by a delayed probe pulse, appears as a roughly circular area of reduced reflectivity centered on the pump spot, that expands to as much as 12{+-}3 {mu}m in radius within 500 fs. We present a semiempirical model in which the pump laser pulse drives hot electrons into the target via collisionless interactions. A return current heats the target and, above a critical temperature, includes runaway electrons that return to the surface before dissipating their energy. Ultrafast radial expansion of the heated surface layer is explained by lateral diffusive motion of returning runaway electrons oscillating across the target surface layer confined by space charge. Isotropy of the observed expansion is consistent with dominance of resonance absorption over jxB heating, indicating prepulse heating is important.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental Study of Counterflow Cooling Using a Test Loop to Simulate the Thermal Characteristics of a HTS Cable System

The counterflow cooling configuration is a compact, efficient, and relatively low cost thermal management approach for long-length HTS cable systems. In the counter-flow cooling configuration the coolant flow, typically liquid nitrogen, is initially supplied through the center of the cable turning around at the far end of the cable and returning through the annular space between the cable and the inner cryostat wall, using a single cryostat. The temperature distributions along the cable and the nitrogen flow streams are extremely difficult to measure in an operating HTS cable because of the issues associated with installing thermometers on high voltage components. A 5-meter long test loop has been built that simulates a counter-flow cooled, HTS cable using a heated metal tube to simulate the cable. The test loop contains calibrated thermometers to measure the temperature distribution along the tube and the return liquid nitrogen stream. Measured temperature distributions in the return flow stream and along the tube wall for varying flow rates and heating conditions to simulate a HTS cable are presented and discussed.

Demko, Jonathan A↗

Field Performance of Inverter-Driven Heat Pumps in Cold Climates

Traditionally, air-source heat pumps (ASHPs) have been used more often in warmer climates; however, some new ASHPs are gaining ground in colder areas. These systems operate at subzero (Fahrenheit) temperatures and many do not include backup electric resistance elements. There are still uncertainties, however, about capacity and efficiency in cold weather. Also, questions such as “how cold is too cold?” do not have clear answers. These uncertainties could lead to skepticism among homeowners; poor energy savings estimates; suboptimal system selection by heating, ventilating, and air-conditioning contractors; and inconsistent energy modeling. In an effort to better understand and characterize the heating performance of these units in cold climates, the U.S. Department of Energy Building America team, Consortium for Advanced Residential Buildings (CARB), monitored seven inverter-driven, ductless ASHPs across the Northeast. Operating data were collected for three Mitsubishi FE18 units, three Mitsubishi FE12 units, and one Fujitsu 15RLS2 unit. The intent of this research was to assess heat output, electricity consumption, and coefficients of performance (COPs) at various temperatures and load conditions. This assessment was accomplished with long- and short-term tests that measured power consumption; supply, return, and outdoor air temperatures; and airflow through the indoor fan coil.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ion-Conducting Thermoresponsive Films Based on Polymer-Grafted Cellulose Nanocrystals

Mechanically robust, thermo-responsive, ion-conducting nanocomposite films are prepared from poly(2-phenylethyl methacrylate) grafted cellulose nanocrystals (MxG-CNC-g-PPMA). One-component nanocomposite films of the polymer grafted nanoparticle (PGN) MxG-CNC-g-PPMA are imbibed with 30 wt% imidazolium-based ionic liquid, to produce flexible ion-conducting films. These films with 1-hexyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide (MxG-CNC-g-PPMA/[H]) not only displays remarkable improvements in toughness (>25 times) and tensile strength (>70 times) relative to the corresponding nanocomposites consisting of the ionic liquid imbibed in the two component CNC/PPMA nanocomposite, but also shows higher ionic conductivity than the corresponding neat PPMA with the same wt.% of ionic liquid. Notably, the one-component film containing 1-ethyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide (MxG-CNC-g-PPMA/[E]) exhibits temperature responsive ionic conduction. The ionic conductivity decreases at around 60°C as a consequence of the lower critical solution temperature (LCST) phase transition of the grafted polymer in the ionic liquid, which leads to phase separation. Moreover, holding the MxG-CNC-g-PPMA/[E] film at room temperature for 24 hours returns the film to its original homogenous state. These materials exhibit properties relevant to thermal cutoff safety devices (e.g., thermal fuse) where a reduction in conductivity above a critical temperature is needed.

36 MATERIALS SCIENCE↗

High-frequency electrical behavior in V 3 O 5 thin films

Vanadium oxides are known for their metal–insulator transition (MIT), with V 3 O 5 being notable for its transition temperature exceeding room temperature. At about 430 K, this material shows a change in crystal symmetry accompanied with one order of magnitude increase in its electrical conductivity and alterations in its optical properties. Although the property changes during the MIT in V 3 O 5 are less pronounced than those observed in VO 2 , its transition temperature is 90 K higher, making it appealing for applications requiring elevated temperatures. In this article, the high-frequency characteristics were determined in a V 3 O 5 two-terminal device in the range from 5 to 35 GHz. The S-parameters showed that the return loss at room temperature was close to −1.5 dB, and the isolation between ports was approximately −50 dB. At temperatures above the metal–insulator transition, the isolation decreased to around −40 dB at 35 GHz. For S11 and S22, similar behavior was observed at room temperature, with a notable change in the S-parameter phase of the device. This behavior suggests that V 3 O 5 may function well as a capacitor because the considerable change in phase could control the flow of electrical signals in devices. This property also may be used for matching purposes, especially considering its response to temperature changes. Additionally, conductivity calculation from S-parameters shows a decrease of approximately two orders of magnitude at 500 K and one order of magnitude at 300 K compared to DC values. These findings highlight V 3 O 5 potential for integration into radio frequency devices that demand consistent performance in high-temperature environments.

36 MATERIALS SCIENCE↗

Temperature-Following Thermal Barrier Coatings for High Efficiency Engines (Final Report)

HRL Laboratories and General Motors (GM), pursued this effort to increase the efficiency of internal combustion engines (ICEs) by developing and implementing temperature-following thermal barrier coatings (TBCs) to decrease heat loss from the combustion chamber. HRL developed microsphere TBCs based on hollow high-temperature alloy spheres with average diameter of 50 μm and wall thickness ~1 μm (microspheres) that achieve unprecedented low thermal conductivity and heat capacity (10X lower than the state of the art) while offering exceptional environmental and mechanical resistance.> In current ICEs, approximately 29% of the fuel’s energy is lost to the cooling system and about 22% goes into moving the car. By limiting heat losses from the combustion chamber with insulating coatings, fuel energy can be redirected into additional piston work and into the exhaust stream. The additional energy that goes into the exhaust stream can be turned into useful work through the use of an exhaust energy recovery device, such as turbocompounding and/or through driving a turbocharger to increase the power density of the engine allowing downsizing. Insulating coatings for piston crowns have been pursued in the past, but previous materials—typically ceramics—exhibited low thermal conductivity but retained high heat capacity. Such materials reduce heat losses but stabilize at a high surface temperature. The high surface temperature heats the incoming gases, which lowers volumetric efficiency and increases propensity for knock, resulting in degraded engine performance. This program developed an innovative new material that combines low thermal conductivity with low heat capacity. These unique properties allow it to follow rapid changes in gas temperature during each combustion cycle. A metallic microsphere TBC has been demonstrated that exhibits increased surface temperature during the combustion period, resulting in reduced heat transfer losses, while still returning to a low surface temperature during the gas exchange period. A 10X lower thermal conductivity and heat capacity than state-of-the-art thermal barrier coatings has been demonstrated. These unprecedented thermal properties are achieved through the coating architecture, which consists of closed pores on the microscale and exhibits a total porosity of 90% to 95%. By selecting a high-temperature nickel alloy as the coating material, the ductility and strength of metals can be harnessed to achieve much better durability and damage tolerance than brittle ceramic coatings can achieve.

33 ADVANCED PROPULSION SYSTEMS↗

TEMPERATURE HISTORY AND DYNAMICAL EVOLUTION OF (101955) 1999 RQ 36: A POTENTIAL TARGET FOR SAMPLE RETURN FROM A PRIMITIVE ASTEROID

It has been recently shown that near-Earth objects (NEOs) have a temperature history-due to the radiative heating by the Sun-non-trivially correlated to their present orbits. This is because the perihelion distance of NEOs varies as a consequence of dynamical mechanisms, such as resonances and close encounters with planets. Thus, it is worth investigating the temperature history of NEOs that are potential targets of space missions devoted to return samples of prebiotic organic compounds. Some of these compounds, expected to be found on NEOs of primitive composition, break up at moderate temperatures, e.g., 300-670 K. Using a model of the orbital evolution of NEOs and thermal models, we studied the temperature history of (101955) 1999 RQ{sub 36} (the primary target of the mission OSIRIS-REx, proposed in the program New Frontiers of NASA). Assuming that the same material always lies on the surface (i.e., there is no regolith turnover), our results suggest that the temperatures reached during its past evolution affected the stability of some organic compounds at the surface (e.g., there is 50% probability that the surface of 1999 RQ{sub 36} was heated at temperatures {>=}500 K). However, the temperature drops rapidly with depth: the regolith at a depth of 3-5 cm, which is not considered difficult to reach with the current designs of sampling devices, has experienced temperatures about 100 K below those at the surface. This is sufficient to protect some subsurface organics from thermal breakup.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Suppression of the metal-insulator transition by magnetic field in (Pr{sub 1−y}Y{sub y}){sub 0.7}Ca{sub 0.3}CoO{sub 3} (y = 0.0625)

The (Pr{sub 1−y}Y{sub y}){sub 0.7}Ca{sub 0.3}CoO{sub 3} compound (y = 0.0625, T{sub MI-SS}=40 K), at the lower limit for occurrence of the first-order metal-insulator (MI) and simultaneous spin-state (SS) transitions, has been studied using electrical resistivity and magnetization measurements in magnetic fields up to 17 T. The isothermal experiments demonstrate that the low-temperature insulating phase can be destabilized by an applied field and the metallic phase returns well below the transition temperature T{sub MI-SS}. The reverse process with decreasing field occurs with a significant hysteresis. The temperature scans taken at fixed magnetic fields reveal a parabolic-like decrease in T{sub MI-SS} with increasing field strength and a complete suppression of the MI-SS transition in fields above 9 T.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Climate Model Response from the Geoengineering Model Intercomparison Project (GeoMIP)

Solar geoengineering—deliberate reduction in the amount of solar radiation retained by the Earth—has been proposed as a means of counteracting some of the climatic effects of anthropogenic greenhouse gas emissions. We present results from Experiment G1 of the Geoengineering Model Intercomparison Project, in which 12 climate models have simulated the climate response to an abrupt quadrupling of CO2 from preindustrial concentrations brought into radiative balance via a globally uniform reduction in insolation. Models show this reduction largely offsets global mean surface temperature increases due to quadrupled CO2 concentrations and prevents 97% of the Arctic sea ice loss that would otherwise occur under high CO2 levels but, compared to the preindustrial climate, leaves the tropics cooler (-0.3 K) and the poles warmer (+0.8 K). Annual mean precipitation minus evaporation anomalies for G1 are less than 0.2mmday-1 in magnitude over 92% of the globe, but some tropical regions receive less precipitation, in part due to increased moist static stability and suppression of convection. Global average net primary productivity increases by 120% in G1 over simulated preindustrial levels, primarily from CO2 fertilization, but also in part due to reduced plant heat stress compared to a high CO2 world with no geoengineering. All models show that uniform solar geoengineering in G1 cannot simultaneously return regional and global temperature and hydrologic cycle intensity to preindustrial levels.

climate↗

Thermal hydraulic model of the molten salt reactor experiment with the NEAMS system analysis module

System analysis codes have a long history of providing best-estimate and conservative safety analysis for both light water and advanced reactor technologies, including molten salt reactors. As interest continues to expand with advanced reactor concepts, system analysis codes will need revisions to accommodate the behavior of these technologies. Legacy system analysis codes will need to be updated to the latest numerical techniques to shorten execution time and increase the accuracy of results. One example of a modern system analysis code that already encompasses these characteristics is the System Analysis Module (SAM). One key objective of this paper was to review available information for system code modeling of the Molten Salt Reactor Experiment (MSRE) from sources in the open literature and collect the information from these open sources in one place for the first time. This supports the potential objective of developing an open specification for system code analysis for MSRE steady state and transients with and without reactor kinetics. Data from actual MSRE tests will serve as the basis for code-to-code comparison exercises, including the MSRE zero power physics tests, the fuel pump start-up and coast down tests, and the natural circulation transient. The objective is to produce a code-to-code benchmark with a standardized set of comparison problems, recognizing the limitations of the original data. To demonstrate an initial application of this objective and the usefulness of compiling this open data, two Molten Salt Reactor Experiment (MSRE)-related models were developed to evaluate SAM for liquid fueled molten salt reactors. One model was the SAM MSRE hydraulic mockup, which provided experimental data for pressure drop measurements. The second model was the complete MSRE primary loop. The MSRE primary loop model incorporated a fluoride salt fuel/coolant with heat transfer in both the core and heat exchanger. For both the hydraulic mockup and MSRE primary loop models, a holistic 1-D system description was built using open documentation, an open description that can be readily modified and applied for any system analysis code. SAM results for the pressure drop of the hydraulic mockup model were within 6% with measurements. Coolant temperatures for the primary loop model matched the expected axial change in temperature from historical calculations. Using alternative coolant properties obtained from the literature, corresponding to salts with different actinide contents, returned similar trends in core temperature profiles. A thermal hydraulic demonstration of a loss-of-flow transient showed the importance of coupling SAM thermal hydraulic analysis to neutronics. Here, this coupling is essential for simulating MSR transients with system analysis codes.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗