Search NASA⌕ Search

SEARCH · Search NASA

Results for “SCaN”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

PSIDD (2): A Prototype Post-Scan Interactive Data Display System for Detailed Analysis of Ultrasonic Scans

This article presents the description of PSIDD(2), a post-scan interactive data display system for ultrasonic contact scan and single measurement analysis. PSIDD(2) was developed in conjunction with ASTM standards for ultrasonic velocity and attenuation coefficient contact measurements. This system has been upgraded from its original version PSIDD(1) and improvements are described in this article. PSIDD(2) implements a comparison mode where the display of time domain waveforms and ultrasonic properties versus frequency can be shown for up to five scan points on one plot. This allows the rapid contrasting of sample areas exhibiting different ultrasonic properties as initially indicated by the ultrasonic contact scan image. This improvement plus additional features to be described in the article greatly facilitate material microstructural appraisal.

Cao, Wei↗

Combined frequency modulated atomic force microscopy and scanning tunneling microscopy detection for multi-tip scanning probe microscopy applications

A method which allows scanning tunneling microscopy (STM) tip biasing independent of the sample bias during frequency modulated atomic force microscopy (AFM) operation is presented. The AFM sensor is supplied by an electronic circuit combining both a frequency shift signal and a tunneling current signal by means of an inductive coupling. This solution enables a control of the tip potential independent of the sample potential. Individual tip biasing is specifically important in order to implement multi-tip STM/AFM applications. An extensional quartz sensor (needle sensor) with a conductive tip is applied to record simultaneously topography and conductivity of the sample. The high resonance frequency of the needle sensor (1 MHz) allows scanning of a large area of the surface being investigated in a reasonably short time. A recipe for the amplitude calibration which is based only on the frequency shift signal and does not require the tip being in contact is presented. Additionally, we show spectral measurements of the mechanical vibration noise of the scanning system used in the investigations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Direct Nanoscale Characterization of Deep Levels in AgCuInGaSe 2 Using Electron Energy–Loss Spectroscopy in the Scanning Transmission Electron Microscope

A new experimental framework for the characterization of defects in semiconductors is demonstrated. Through the direct, energy-resolved correlation of three analytical techniques spanning six orders of magnitude in spatial resolution, a critical mid-bandgap electronic trap level (E V + 0.56 eV) within Ag 0.2 Cu 0.8 In 1–x Ga x Se 2 is traced to its nanoscale physical location and chemical source. This is achieved through a stepwise, site-specific correlated characterization workflow consisting of device-scale (≈1 mm 2 ) deep level transient spectroscopy (DLTS) to survey the traps present, scanning probe–based DLTS (scanning-DLTS) for mesoscale-resolved (hundreds of nanometers) mapping of the target trap state’s spatial distribution, and scanning transmission electron microscope based electron energy-loss spectroscopy (STEM-EELS) and X-ray energy-dispersive spectroscopy for nanoscale energy-, structure, and chemical-resolved investigation of the defect source. Furthermore, this first demonstration of the direct observation of sub-bandgap defect levels via STEM-EELS, combined with the DLTS methods, provides strong evidence that the longsuspected Cu In/Ga substitutional defects are indeed the most likely source of the E V + 0.56 eV trap state and serves as a key example of this approach for the fundamental identification of defects within semiconductors, in general.

14 SOLAR ENERGY↗

Spatial Resolution in Scanning Electron Microscopy and Scanning Transmission Electron Microscopy Without a Specimen Vacuum Chamber

Abstract A long-standing goal of electron microscopy has been the high-resolution characterization of specimens in their native environment. However, electron optics require high vacuum to maintain an unscattered and focused probe, a challenge for specimens requiring atmospheric or liquid environments. Here, we use an electron-transparent window at the base of a scanning electron microscope’s objective lens to separate column vacuum from the specimen, enabling imaging under ambient conditions, without a specimen vacuum chamber. We demonstrate in-air imaging of specimens at nanoscale resolution using backscattered scanning electron microscopy (airSEM) and scanning transmission electron microscopy. We explore resolution and contrast using Monte Carlo simulations and analytical models. We find that nanometer-scale resolution can be obtained at gas path lengths up to 400 μ m, although contrast drops with increasing gas path length. As the electron-transparent window scatters considerably more than gas at our operating conditions, we observe that the densities and thicknesses of the electron-transparent window are the dominant limiting factors for image contrast at lower operating voltages. By enabling a variety of detector configurations, the airSEM is applicable to a wide range of environmental experiments including the imaging of hydrated biological specimens and in situ chemical and electrochemical processes.

Nguyen, Kayla X. (ORCID:0000000192537064)↗

Phase Equilibrium of Water with Hexagonal and Cubic Ice Using the SCAN Functional

Machine learning models are rapidly becoming widely used to simulate complex physicochemical phenomena with ab initio accuracy. Here, we use one such model as well as direct density functional theory (DFT) calculations to investigate the phase equilibrium of water, hexagonal ice (Ih), and cubic ice (Ic), with an eye toward studying ice nucleation. The machine learning model is based on deep neural networks and has been trained on DFT data obtained using the SCAN exchange and correlation functional. We use this model to drive enhanced sampling simulations aimed at calculating a number of complex properties that are out of reach of DFT-driven simulations and then employ an appropriate reweighting procedure to compute the corresponding properties for the SCAN functional. This approach allows us to calculate the melting temperature of both ice polymorphs, the driving force for nucleation, the heat of fusion, the densities at the melting temperature, the relative stability of ices Ih and Ic, and other properties. We find a correct qualitative prediction of all properties of interest. In some cases, quantitative agreement with experiment is better than for state-of-the-art semiempirical potentials for water. Furthermore, our results also show that SCAN correctly predicts that ice Ih is more stable than ice Ic.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Reproducible strain measurement in electronic devices by applying integer multiple to scanning grating in scanning moiré fringe imaging

Scanning moiré fringe (SMF) imaging by high-angle annular dark field scanning transmission electron microscopy was used to measure the strain field in the channel of a transistor with a CoSi{sub 2} source and drain. Nanometer-scale SMFs were formed with a scanning grating size of d{sub s} at integer multiples of the Si crystal lattice spacing d{sub l} (d{sub s} ∼ nd{sub l}, n = 2, 3, 4, 5). The moiré fringe formula was modified to establish a method for quantifying strain measurement. We showed that strain fields in a transistor measured by SMF images were reproducible with an accuracy of 0.02%.

36 MATERIALS SCIENCE↗

Tilted lidar profiling: Development and testing of a novel scanning strategy for inhomogeneous flows

The most common profiling techniques for the atmospheric boundary layer based on a monostatic Doppler wind lidar rely on the assumption of horizontal homogeneity of the flow. This assumption breaks down in the presence of either natural or human-made obstructions that can generate significant flow distortions. The need to deploy ground-based lidars near operating wind turbines for the American WAKE experimeNt (AWAKEN) spurred a search for novel profiling techniques that could avoid the influence of the flow modifications caused by the wind farms. With this goal in mind, two well-established profiling scanning strategies have been retrofitted to scan in a tilted fashion and steer the beams away from the more severely inhomogeneous region of the flow. Results from a field test at the National Renewable Energy Laboratory's 135-m meteorological tower show that the accuracy of the horizontal mean flow reconstruction is insensitive to the tilt of the scan, although higher-order wind statistics are severely deteriorated at extreme tilts mainly due to geometrical error amplification. A numerical study of the AWAKEN domain based on the Weather Research and Forecasting Model and large-eddy simulation are also conducted to test the effectiveness of tilted profiling. It is shown that a threefold reduction of the error on inflow mean wind speed can be achieved for a lidar placed at the base of the turbine using tilted profiling.

17 WIND ENERGY↗

TH-CD-209-10: Scanning Proton Arc Therapy (SPArc) - The First Robust and Delivery-Efficient Spot Scanning Proton Arc Therapy

Purpose: To develop a delivery-efficient proton spot-scanning arc therapy technique with robust plan quality. Methods: We developed a Scanning Proton Arc(SPArc) optimization algorithm integrated with (1)Control point re-sampling by splitting control point into adjacent sub-control points; (2)Energy layer re-distribution by assigning the original energy layers to the new sub-control points; (3)Energy layer filtration by deleting low MU weighting energy layers; (4)Energy layer re-sampling by sampling additional layers to ensure the optimal solution. A bilateral head and neck oropharynx case and a non-mobile lung target case were tested. Plan quality and total estimated delivery time were compared to original robust optimized multi-field step-and-shoot arc plan without SPArc optimization (Arcmulti-field) and standard robust optimized Intensity Modulated Proton Therapy(IMPT) plans. Dose-Volume-Histograms (DVH) of target and Organ-at-Risks (OARs) were analyzed along with all worst case scenarios. Total delivery time was calculated based on the assumption of a 360 degree gantry room with 1 RPM rotation speed, 2ms spot switching time, beam current 1nA, minimum spot weighting 0.01 MU, energy-layer-switching-time (ELST) from 0.5 to 4s. Results: Compared to IMPT, SPArc delivered less integral dose(−14% lung and −8% oropharynx). For lung case, SPArc reduced 60% of skin max dose, 35% of rib max dose and 15% of lung mean dose. Conformity Index is improved from 7.6(IMPT) to 4.0(SPArc). Compared to Arcmulti-field, SPArc reduced number of energy layers by 61%(276 layers in lung) and 80%(1008 layers in oropharynx) while kept the same robust plan quality. With ELST from 0.5s to 4s, it reduced 55%–60% of Arcmulti-field delivery time for the lung case and 56%–67% for the oropharynx case. Conclusion: SPArc is the first robust and delivery-efficient proton spot-scanning arc therapy technique which could be implemented in routine clinic. For modern proton machine with ELST close to 0.5s, SPArc would be a popular treatment option for both single and multi-room center.

60 APPLIED LIFE SCIENCES↗

X-ray diffraction, differential scanning calorimetry and evolved gas analysis of aged plutonium tetrafluoride (PuF4)

A 30 year-old PuF4 sample consisting of brown powder (PuF4-b) and pink granules (PuF4-p) was analyzed. X-ray difraction shows the bulk is comprised of three compounds: PuF4, PuO2, and PuF4·1.6H2O. Broadening of PuF4 XRD peaks suggests possible a-damage. After annealing at 650 °C, crystalline PuF4 and PuO2 remain. Thermogravimetric analysis and diferential scanning calorimetry—with simultaneous evolved gas analysis—of the separated PuF4-p and PuF4-b components reveal a distinct sequence of reactions. Dehydration occurs between~90 and 300 °C. Exothermic annealing of the a-damage occurs in two stages: at 350–355 °C and at 555–558 °C. Hydrofuoric acid, fuorine and helium desorb during the frst exotherm. Above 700 °C, PuF4 reacts with PuO2, resulting in oxygen release and mass loss.

PuF4, dsc, differential scanning calorimetry, plut↗

Investigating Fast Scanning Calorimetry and Differential Scanning Calorimetry as Screening Tools for Thermoset Polymer Material Compatibility with Laser-Based Powder Bed Fusion

As additive manufacturing (AM) technology has developed and progressed, a constant topic of research in the area is expanding the library of materials to be used with these techniques. Among AM methods that utilize polymers, laser-based powder bed fusion (PBF-LB) has preferentially used thermoplastic polymers as its starting materials, but the deposition and material joining method employed in PBF-LB may also be compatible with powdered thermoset polymer precursors as feedstocks. To assess the compatibility of candidate thermosetting polymers and PBF-LB, characterization techniques and protocols that link fundamental material behavior to material behavior in the processing environment are needed. Therefore, the objectives of this work are to compare the curing behavior measured with two different calorimetry techniques that can operate in different heating rate regimes, differential scanning calorimetry (DSC) and fast scanning calorimetry (FSC), and to assess the capabilities of these techniques to act as materials screening tools for PBF-LB. A commercial polyester powder coating is used as a model material to evaluate the potential of obtaining complimentary information for material screening through a combination of calorimetry methods, and its non-isothermal curing behavior is measured at heating rates between 5 °C/min and 7500 °C/min. Curing exotherms are observed with both calorimetry techniques, and comparing the enthalpy associated with curing shows that incomplete curing occurs at higher heating rates, with relative conversion values of approximately 30%. The curing data are fit with two isoconversional models, Friedman and Starink, which show a reduced activation energy at higher heating rates as well, signifying a lower barrier to curing at the conditions used in the FSC experiments. Overall, the results of this work indicate that using these two calorimetry techniques as tiered screening tools can provide valuable information about how curing may proceed in PBF-LB and inform materials selection and design activities for additive manufacturing.

36 MATERIALS SCIENCE↗

Iron on GaN(0001) pseudo-1 × 1 (1+1/(12) ) investigated by scanning tunneling microscopy and first-principles theory

We have investigated sub-monolayer iron deposition on atomically smooth GaN(0001) pseudo-1 × 1 (1+1/(12) ). The iron is deposited at a substrate temperature of 360 °C, upon which reflection high energy electron diffraction shows a transformation to a √(3)×√(3)-R30° pattern. After cooling to room temperature, the pattern transforms to a 6 × 6, and scanning tunneling microscopy reveals 6 × 6 reconstructed regions decorating the GaN step edges. First-principles theoretical calculations have been carried out for a range of possible structural models, one of the best being a Ga dimer model consisting of 2/9 monolayer of Fe incorporated into 7/3 monolayer of Ga in a relaxed but distorted structure.

36 MATERIALS SCIENCE↗

Characterization of one-dimensional molecular chains of 4,4′-biphenyl diisocyanide on Au(111) by scanning tunneling microscopy

The morphology and electronic structure of vapor deposited 4,4′-biphenyldiisocyanide (BPDI) on a Au(111) surface were investigated using variable-temperature scanning tunneling microscopy. When deposited at room temperature, BPDI molecules form one-dimensional molecular chains similar to that recently observed for the structurally related 1,4-phenyl diisocyanide (PDI). Compared to PDI, the longer periodicity for the BPDI molecular chains is consistent with the addition of a second phenyl ring and supports a structural model in which the BPDI molecules lie parallel to the surface and interconnected by Au-adatoms. The molecular chains are mostly aligned along the [11{sup -}0] direction of the Au(111) substrate, but exhibit frequent changes in angle that are consistent with directions between fcc and hcp three-fold hollow sites. Dispersion-corrected density functional theory calculations for one-dimensional chains of BPDI molecules bound end-to-end via their isocyanide groups to Au-adatoms reproduce the observed periodicity of the chains and show that this morphology is energetically favored over upright binding with one free —NC group. The spatially resolved conductance (dI/dV) map for BPDI on Au(111) exhibits a feature centered at −0.67 eV below the Fermi level which are delocalized along the chain with maxima at the Au-adatom and biphenyl positions. This occupied resonant feature is close to that previously observed for the PDI in both photoemission and conductance measurements and is attributed to an occupied interfacial state resulting from BPDI-Au interactions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Resolution in Carrier Profiling Semiconductors by Scanning Spreading Resistance Microscopy and Scanning Frequency Comb Microscopy

High resolution measurements of the carrier profile in semiconductor devices is required as the semiconductor industry progresses from the 10-nm lithography node to 7-nm and beyond. We examine the factors which determine the resolution of the present method of scanning spreading resistance microscopy as well as such factors for the newer method of scanning frequency comb microscopy that is now under development. Also, for the first time, we consider the sensitivity of both methods to the location of heterogeneities in the semiconductor. In addition, mesoscopic effects on these measurements are considered for the first time. Two simple analytical models are extended to study the sensitivity to heterogeneities as well as mesoscopic effects.

36 MATERIALS SCIENCE↗

The Role of Gas in Determining Image Quality and Resolution During In Situ Scanning Transmission Electron Microscopy Experiments

As gas-solid heterogeneous catalytic reactions are molecular in nature, a full mechanistic understanding of the process requires atomic scale characterization under realistic operating conditions. While atomic resolution imaging has become a routine in modern high-vacuum (scanning) transmission electron microscopy ((S)TEM), both image quality and resolution nominally degrade when reaction gases are introduced. In this work, we systematically assess the effects of different gases at various pressures on the quality and resolution of images obtained at room temperature in the annular dark field STEM imaging mode using a differentially pumped (DP) gas cell. This imaging mode is largely free from inelastic scattering effects induced by the presence of gases and retains good imaging properties over a wide range of gas mass/pressures. We demonstrate the application of the ESTEM with atomic resolution images of a complex oxide alkane oxidation catalyst MoVNbTeOx (M1) immersed in light and heavy gas environments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Probing the limits of Si:P δ -doped devices patterned by a scanning tunneling microscope in a field-emission mode

Recently, a single atom transistor was deterministically fabricated using phosphorus in Si by H-desorption lithography with a scanning tunneling microscope (STM). This milestone in precision, achieved by operating the STM in the conventional tunneling mode, typically utilizes slow (∼102 nm2/s) patterning speeds. By contrast, using the STM in a high-voltage (>10 V) field-emission mode, patterning speeds can be increased by orders of magnitude to ≳104 nm2/s. We show that the rapid patterning negligibly affects the functionality of relatively large micron-sized features, which act as contacting pads for these devices. For nanoscale structures, we show that the resulting electrical transport is consistent with the donor incorporation chemistry constraining the electrical dimensions to a scale of 10 nm even though the pattering spot size is 40 nm.

Rudolph, M.↗