Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sample Preparation Laboratory”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Novel Sample-handling Approach for XRD Analysis with Minimal Sample Preparation

Sample preparation and sample handling are among the most critical operations associated with X-ray diffraction (XRD) analysis. These operations require attention in a laboratory environment, but they become a major constraint in the deployment of XRD instruments for robotic planetary exploration. We are developing a novel sample handling system that dramatically relaxes the constraints on sample preparation by allowing characterization of coarse-grained material that would normally be impossible to analyze with conventional powder-XRD techniques.

Sarrazin, P.↗

Tank 14H Preliminary Cease Waste Removal Sample Analyses

Savannah River Mission Completion Waste Removal and Tank Closure requested that Savannah River National Laboratory perform characterization analyses of Tank 14H in support of closure activities, specifically preliminary cease waste removal. This report provides important characterization of the prepared filtrate and air-dried solids in the January 2026 Tank 14H sample, HTF-14-26-1,2,3,4,5,6, for I-129, Tc-99, Cs-137, and Sr-90. The results reported here were utilized by SRMC to declare preliminary cease waste removal for Tank 14H.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Olivine Dissolution and Formation of Secondary phases in Ultramafic Soils

Introduction: Olivine has been proposed as an indicator for the duration of water-rock interaction within Martian rocks and sediments [1-3]. The use of olivine as a mineralogical indicator for past aqueous alteration on Mars requires interpretation of a complex combination of factors including pH, temperature, and composition [5,6]. Here, we examine the persistence of natural olivine within terrestrial ultramafic soils (Fe/Mg-rich, Al-poor) developing under different climatic conditions and the incipient dissolution of emplaced forsterite (Fo) and fayalite (Fa) surfaces to investigate environmental effects on incipient olivine dissolution, olivine persistence in soils, and formation of secondary phases. Methods: Field Sites. We examined olivine weathering and secondary material formation in ultramafic soils at 6 sites in the Klamath Mountains (KM) of northern California with a mean annual temperature of ~12.8℃ and precipitation of ~55.7-95.4 cm/year [7], and soil pH of ~6.5-7.3; 4 sites in the Tablelands (TB) of Newfoundland, Canada with a mean annual temperature of <3.9℃ and precipitation of ~120.0 cm/year [8], and soil pH of ~7.7; and at 3 sites at Pickhandle Gulch (PG), Nevada with a mean annual temperature of ~14.4℃ and precipitation of ~14.1 cm/year [7], and soil pH of ~8.5. Sampling sites span an age range of ~12.1-50+ kya in the Klamath Mountains [9,10] and ~13-30 kya in the Tablelands [11]. Pickhandle Gulch sites are undated. Parent Material and Soil Analyses. Polished thin sections of bulk soil prepared by Wagner Petrographic, Inc were carbon-coated and analyzed on a JEOL 2100 SEM in back-scattered electron mode in the EMIL lab at UNLV and at the 13-ID-E synchrotron beamline at Argonne National Laboratory using µXRF, µXRD, and XAS. Soil and parent material samples were powdered in a Fritsch pulverisette and analyzed by XRD and soil by VNIR. Soil preparation is further described in [12]. Disk Preparation, Burial, and Collection. Fo disks were cut from a column prepared via hot-pressing and Fa disks by sintering synthetic fayalite powder, see [13] for detail. Disks were polished to a 0.25-micron level with diamond grit. Disks were buried in 3 KM soils, 4 TB soils, and 3 PG soils, collected after exactly 365 days, and washed gently with 100% reagent grade ethanol to remove potential adhered soil material. Weathered disks and soil samples were stored in a -20℃ freezer until analysis. Unaltered control disks prepared identically to the buried disks were stored at -20℃ for the duration of the experiment. Disk Analyses. One Fo and Fa disk from each climate zone was analyzed on a variable pressure Zeiss Supra 40VP SEM at Northern Arizona University. A separate Fo and Fa disk from each climate zone was analyzed by XPS using a Physical Electronics VersaProbe II at the Penn State Univ. Materials Characterization Lab after a Na-dodecyl sulfate wash and ozonation to remove carbon contamination as in [14]. VNIR measurements were conducted at Johnson Space Center using an ASD FieldSpec3 under ambient lab conditions on a separate Fo and Fa disk from each climate zone. One separate Fo and Fa control sample was analyzed for each technique for comparison with weathered samples. XPS uncertainty was determined from 5 repeat measurements on controls. Results: Bedrock and Soil Results Olivine is present in the parent material in the KM and TB. Olivine is found in ~12.1 ka KM soils but is absent from all older soils, while persisting into the oldest (>20 ka) TB soil (Figure 1). In both locations, olivine is found as cores surrounded by a serpentine rind (Figure 2). VNIR spectra from the analyzed soils possess strong OH-associated spectral features at ~2.33 µm indicating the presence of Mg-rich phyllosilicates as well as ferric-oxide features at ~0.92 µm in the KM (Figure 3). Primary crystalline silicate grains mostly incorporate Fe2+, while poorly crystalline weathering rinds are best fit by ferric oxide XAS standards (Figure 4). µXRF also shows that Fe and Ni concentrate in weathering rinds and Cr remains within interior silicate grains (Figure 4). Buried Sample Results All Fo surfaces exhibited formation of dissolution features including shallow pitting not observed on controls. Dissolution features were most visually widespread on the KM disk (Figure 5). Leaching of Mg from KM and TB Fo disks was evident from <1.6 Mg/Si ratios measured by XPS (Figure 6). Fe-rich precipitates in SEM (Figure 5) and Fe presence in XPS scans (Figure 6) indicate Fe deposition onto KM and TB Fo disk surfaces. The appearance of a spectral feature at 0.55 µm in the VNIR spectra from the TB Fo suggests this Fe is ferric (Figure 7). The PG Fo appears least altered, with minimal formation of dissolution features in SEM (Figure 5), a Mg/Si ratio inconsistent with leaching (~2) (Figure 6), and VNIR spectra almost identical to the control sample. Analysis of Fa surfaces is ongoing. The higher temperatures and more acidic pH in the KM soils likely drive the faster dissolution of the Fo disks described above. While the TB soils experience greater precipitation than in the KM, the cooler temperatures and more basic soil pH facilitate observable but more limited alteration. The dry climate and basic soil pH at PG lead to minimal dissolution of the PG disk surfaces.

A D Feldman↗

Determination of Phenols and Trimethylamine in Industrial Effluents

For regulatory purposes to control certain odorous compounds the analysis of phenols and trimethylamines in industrial effluents is necessary. The Bay Area Air Pollution Control District laboratory has been determining these gases by gas chromatographic techniques. The procedures for sample collection, preparation for analysis and determination are described in detail. Typical data from various sources showing the effect of proposed regulations is shown. Extensive sampling and usage of these procedures has shown them to be accurate, reliable and suitable to all types of source effluents.

Levaggi, D. A.↗

Laboratory on the Moon: Equipping and Testing of a Habitat Laboratory for the Scientific Exploration of the Moon by Humans

A human habitat on the Moon is predestined to house a laboratory, especially if it is built for scientific missions on the Moon. This laboratory could be used for (1) conducting experiments utilizing the lunar gravity and prepare experiments to be placed outside the laboratory in the lunar environment, (2) conducting analyses of lunar rock and regolith in high volume, and (3) performing preliminary analyses and screening of samples to be sent to Earth for more detailed, specialized analysis. In the past, spaceflight missions have often been implemented by adding scientific instruments after most of the engineering work is already finished, limiting scientific studies to relatively scattered, insular topics. However, if prepared appropriately, a research laboratory on the Moon can help address scientific questions thoroughly and at a fundamental level. Moreover, the challenge of creating a viable habitat is not only an engineering one, but one that requires input from architects, designers, and psychologists. After all, the crew not only works inside the habitat laboratory, but they spend (close to) their entire time on the Moon inside the habitat and under the isolation and confinement that comes with it. We combine science, engineering, and architecture to create a habitat laboratory that meets their conflicting requirements: The laboratory of the Moon and Mars Base Analog (MaMBA) has been designed with inputs from (1) scientists of selected disciplines, particularly geology, materials science, chemistry, biology, and medicine, (2) space architects specializing on extraterrestrial bases, and (3) engineers for the constraints imposed by the lunar environment. The MaMBA laboratory was built in 2019 into the mock-up of the first MaMBA module (out of six). Subsequently, the laboratory was tested by volunteer scientists for its usability. The scientists used the laboratory for work deemed representative of lunar scientific analyses; the complete test runs lasted one week each, with one test run in June 2019 and the second test run in late September 2019 following some modifications suggested by the scientists. Here, we will present an overview of the scientific topics that we think should be addressed on the Moon, together with a suggestion of scientific instrumentation that would be helpful for such investigations. Moreover, we present the MaMBA laboratory, equipped with the proposed instrumentation, and the outcomes of the test runs with a particular focus on the lessons learned regarding the equipping of the laboratory.

Christiane Heinicke↗

Creep suppression and fatigue in bio-based composites manufactured via conventional and large format additive manufacturing processes

The emergence of novel extrusion-based additive manufacturing (AM) processes has prompted the development of new thermoplastic composite feedstocks, and broadening sustainability initiatives have driven the development of bio-based and recyclable material for AM feedstocks. Poly(lactic acid) (PLA) with wood flour (WF) is one composite system that has been demonstrated in numerous AM applications, as well as traditional processing methods (i.e., compression and injection molding); however, there has been a need to understand how the variation in processing methodology impacts the material performance of these bio-based feedstocks from a fundamental perspective, with particular emphasis on creep for an extended application use-life. Herein, PLA/WF is explored as a feedstock material for large format additive manufacturing (LFAM) and the performance of additively manufactured materials is compared to those produced via more traditional processing methods. It is also demonstrated that the addition of WF decreases the material’s coefficient of thermal expansion (CTE) while increasing its Young’s modulus, susceptibility to water uptake, and creep fatigue resistance. Essentially, the addition of 20 wt% WF results in a 92 % decrease in rubbery regime CTE while simultaneously resulting in a 14 % increase in modulus, 190 % increase in water uptake, and a 31 % decrease in residual strain after cyclic creep tests. The processing method was also found to play a large role in the final part performance, with the printed material increasing the crystallinity by 183 % and 214 % compared to its compression and injection molded counterparts. Furthermore, the porosity of printed samples increased by two orders of magnitude compared to samples prepared via traditional processing methods.

36 MATERIALS SCIENCE↗

Neutrons reveal the dynamics of leaf thylakoids in living plants

The study is the first known exploration of photosynthetic membranes dynamics in living plants by high resolution quasielastic neutron scattering spectroscopy. We investigated the mobility and flexibility of thylakoid membranes in common duckweed (Landoltia punctata) and identified dynamics across various length scales corresponding to individual membranes and membranes stack. We employed classical models typically used to study lipid bilayers to characterize the undulation modes and rigidity of the membranes and reveal how structural variations influence the observed complex dynamics. Our findings show that the stacks of thylakoids in duckweed behave as rigid systems, exhibiting an effective bending coefficient in the lower range associated with surfactant membranes. In contrast, the single thylakoid leaflets display greater apparent flexibility and are well situated within the bi-continuous surfactant phase dynamics. While our observations enhance the understanding of the intricate architecture and mobility of photosynthetic cellular machinery, they also highlight the limitations of applying ideal lipid membranes models to describe complex biological systems. This work opens more questions and the need for further investigations across extended length and time scales, as well as the importance of rigorous sample preparation and experimental control.

Applied physics↗

LDEF space optics handbook

There is a need to present design guidelines derived from the Long Duration Exposure Facility (LDEF) space optics experiments to hardware designers. In response to this need a small study program was just started by SAIC and POD Associates for the Phillips Laboratory. The objective is to prepare a top-level review of available results on the behavior of certain optical components in the LDEF space experiments. The optics interest centers on optical surfaces and coatings, and fabrication processes for laser windows and mirrors. The program has two main parts: the first phase, to be completed by the end of 1992, consists of identifying and acquiring data from the appropriate investigators. The second phase, ending in December 1993, comprises report preparation as well as selected, prioritized, additional characterization of certain samples, coordinated with the principal investigators and the Phillips Laboratory. This program is getting under way at the time of the Symposium and does not warrant more than the present summary at this time.

Champetier, Robert J.↗

Tank Waste Characterization: History, Challenges, and Success Stories

The preparation and chemical and radiochemical analysis of Hanford tank waste samples can be performed with standard laboratory equipment and instruments as relatively routine processes that are not particularly challenging. Rather, the main challenges of tank waste characterization are associated with radiological dose and sampling limitations. Accurate, representative and effective sampling techniques are difficult with the waste tanks because they were not designed for routine sampling. There are a finite number of sampling locations for each tank based on riser positioning, depth and the operational functionality of the sampling riser. For example, in one recently emptied SST, there was one riser that was found to have had concrete dumped down it, thereby eliminating that sampling port. Additionally, the waste within the tank; especially true for the saltcake and sludge, is not homogenous. The ability to adequately mix a million-gallon double shell tank (DST) is a concern for data reproducibility. Another real challenge that must be addressed for sampling single shell tanks, is how to dissolve the salt cake waste in a compromised (leaking) SST. These physical constraints mean that uncertainty in the representativeness of samples must be considered when applying analytical results to the bulk contents of the tank. The tank waste is highly radioactive and thus can only be handled initially by facilities that can receive samples into concrete-shielded hot cells with remote operation with an example provided in Figure 1. The shielding protects the worker from the radiological dose while mineral oil windows and remotely operated manipulators enables the samples to be handled. At Hanford, analytical laboratories with these hot cell capabilities are limited to the Pacific Northwest National Laboratory and the main Hanford operations support laboratory, 222-S Laboratory. Because of their highly radioactive nature, samples must be sufficiently diluted to facilitate their analysis outside of a shielded cell. In some cases, this means some accuracy must be compromised to complete the analysis beyond that normally encountered for non-radioactive material.

Waste Characterization, BBI, PHOENIX: Tank Farms: ↗

Flash electropolishing for TEM: Reducing FIB‐induced defects in tungsten with protocols for new materials

Focused ion beam (FIB) milling has become the dominant approach for site-specific transmission electron microscopy (TEM) specimen preparation; however, FIB damage remains a critical limitation for reliable microstructural characterisation, particularly in radiation effects studies. Tungsten is especially susceptible to FIB damage due to its high nuclear stopping power, which promotes the formation and strong diffraction contrast of FIB-induced ‘black spot’ defects that are indistinguishable from very fine irradiation-induced loops/defects resulting from low to intermediate temperature neutron irradiation. In this work, flash electropolishing is systematically evaluated as a post-FIB treatment for minimising preparation-induced artefacts for TEM analysis of tungsten-based alloys. Using a range of non-, ion-, and neutron-irradiated tungsten materials, the effectiveness of flash electropolishing has been assessed through direct comparison with conventional FIB and plasma-FIB preparation including low-energy Ga, Ar, Xe ion cleaning. The results demonstrate that flash electropolishing effectively removes FIB-damaged layers and ‘black spot’ defects, thereby enabling reliable observation of irradiation-induced dislocation structures. Key processing parameters governing flash electropolishing quality – including lamella thickness, applied voltage, polishing duration, electrolyte chemistry, and cathode geometry – have been systematically evaluated, and clear criteria were established for determining when flash electropolishing is required to ensure reliable microstructural analysis. This work also provides practical guidance for implementing flash electropolishing as an artefact-controlled specimen-preparation approach for TEM characterisation of FIB-produced specimens. The systematic protocol can be extended to other, non-tungsten materials.

TEM sample preparation↗

Investigating Amino Acid Heterogeneity in Milligram-Scale Samples of the Murchison CM2 Carbonaceous Chondrite

Analyses of different aliquots of the Tagish Lake meteorite have resulted in amino acid abundance variations of an order of magnitude or more, even when performed using the same techniques, by the same personnel, in the same laboratories (e.g., Simkus et al. 2019). Up to ~five-fold variations have been observed for specific amino acids in different samples of the same meteorite, such as α aminoisobutryic acid (AIB) in Murchison. These variations are often attributed differing sample composition or differing alteration history, neither of which is mutually exclusive. Distinguishing between these two explanations is challenging and time consuming, requiring detailed mineralogical analyses to be performed in conjunction with high precision organics analysis. The potential for innate sample-level heterogeneity presents a significant complication when parsing the effects of different processes or conditions during preparation of meteorite samples for analysis, as differences in organic yields or abundances could be due to differences in laboratory processing or differences among the samples themselves. In this work, we investigated the degree of innate organic heterogeneity present in a single ~250 mg chip of divided into 21 samples.

A. S. Burton↗

Electromagnetic Compatibility Test and Analysis Campaign of NASA's Mars 2020 Rover Final Submission

NASA's Mars 2020 Perseverance Rover—with a launch window opening July 2020, and landing expected February 2021—has mission objectives to look for evidence of habitability, seek biosignatures of past life, collect and cache samples for possible future return to Earth, and prepare for future human missions to Mars. The Rover platform is similar to the previous Mars Science Laboratory (MSL) “Curiosity” rover that landed in 2012 but contains a new suite of scientific instruments and upgrades to existing functionality: seven new and/or upgraded scientific payloads, an upgraded arm and sampling system, and a Helicopter demonstration. These changes—along with new efficiency goals to operate more Rover subsystems concurrently and thus collect more science—presented new electromagnetic compatibility (EMC) challenges. In this paper, we will describe the campaign to ensure Mars 2020 mission success from an electromagnetic environment perspective: 1) confirming existing MSL heritage subsystems and EMC requirements were compatible with the new Mars 2020 mission objectives, 2) engaging with engineers and scientists early in the project to identify and evaluate risks before hardware assembly and performing ambitious risk reduction tests, 3) undertaking a comprehensive subsystem qualification test program based on tailored MIL-STD-461F requirements, occasionally leading to redesign, 4) synthesizing the data collected to perform detailed analyses toward the goal of making risk-informed decisions at a system level. The spacecraft successfully completed all three planned system level tests, demonstrating self-compatibility with minimal impact to operations from electromagn

Gonzales, Edward C↗

Evaporation Rate Study and NDMA Formation from UDMH/NO2 Reaction Products

Laboratory samples of uns-dimethylhydrazine (UDMH) fuel/oxidizer (nitrogen dioxide) non-combustion reaction products (UFORP) were prepared using a unique permeation tube technology. Also, a synthetic UFORP was prepared from UDMH, N-nitrosodimethylamine (NDMA), dimethylammonium nitrate, sodium nitrite and purified water. The evaporation rate of UFORP and synthetic UFORP was determined under space vacuum (approx 10(exp -3) Torr) at -40 ?C and 0 ?C. The material remaining was analyzed and showed that the UFORP weight and NDMA concentration decreased over time; however, NDMA had not completely evaporated. Over 85% of the weight was removed by subjecting the UFORP to 10(-3) Torr for 7 hours at -40 ?C and 4 hours at 0 ?C. A mixture of dimethylammonium nitrate and sodium nitrite formed NDMA at a rapid rate in a moist air environment. A sample of UFORP residue was analyzed for formation of NDMA under various conditions. It was found that NDMA was not formed unless nitrite was added.

Buchanan, Vanessa D.↗

Ultrasonic Apparatus for Pulverizing Brittle Material

The figure depicts an apparatus that pulverizes brittle material by means of a combination of ultrasonic and sonic vibration, hammering, and abrasion. The basic design of the apparatus could be specialized to be a portable version for use by a geologist in collecting powdered rock samples for analysis in the field or in a laboratory. Alternatively, a larger benchtop version could be designed for milling and mixing of precursor powders for such purposes as synthesis of ceramic and other polycrystalline materials or preparing powder samples for x-ray diffraction or x-ray fluorescence measurements to determine crystalline structures and compositions. Among the most attractive characteristics of this apparatus are its light weight and the ability to function without need for a large preload or a large power supply: It has been estimated that a portable version could have a mass <0.5 kg, would consume less than 1 W h of energy in milling a 1-cm3 volume of rock, and could operate at a preload <10 N. The basic design and principle of operation of this apparatus are similar to those of other apparatuses described in a series of prior NASA Tech Briefs articles, the two most relevant being Ultrasonic/ Sonic Drill/Corers With Integrated Sensors (NPO-20856), Vol. 25, No. 1 (January 2001), page 38 and Ultrasonic/ Sonic Mechanisms for Deep Drilling and Coring (NPO-30291), Vol. 27, No. 9 (September 2003), page 65. As before, vibrations are excited by means of a piezoelectric actuator, an ultrasonic horn, and a mass that is free to move axially over a limited range. As before, the ultrasonic harmonic motion of the horn drives the free-mass in a combination of ultrasonic harmonic and lower-frequency hammering motion. In this case, the free-mass is confined within a hollow cylinder that serves as a crushing chamber, and the free-mass serves as a crushing or milling tool. The hammering of the free-mass against a material sample at the lower end of the chamber grinds the sample into powder in a relatively short time. The restriction of the free-mass to axial motion only makes the grinding very efficient. The free-mass can be fabricated to have teeth on its lower face to enhance the grinding effect. Optionally, there can be a hole at the bottom of the chamber covered with a sieve to tailor the size distribution of the powder leaving the crushing chamber.

Sherrit, Stewart↗

Cellulose Acetate Replica Cleaning Study of Genesis Non-Flight Sample 3CZ00327

The Genesis mission collected solar wind and brought it back to Earth in order to provide precise knowledge of solar isotopic and elemental compositions. The ions in the solar wind were stopped in the collectors at depths on the order of 10 to a few hundred nanometers. This shallow implantation layer is critical for scientific analysis of the composition of the solar wind and must be preserved throughout sample handling, cleaning, processing, distribution, preparation and analysis. We are working interactively with the community of scientists analyzing Genesis samples, using our unique laboratory facilities -- and, where needed, our unique cleaning techniques -- to significantly enhance the science return from the Genesis mission. This work is motivated by the need to understand the submicron contamination on the collectors in the Genesis payload as recovered from the crash site in the Utah desert, and -- perhaps more importantly -- how to remove it. That is, we are evaluating the effectiveness of the wet-chemical "cleaning" steps used by various investigators, to enable them to design improved methods of stripping terrestrial contamination from surfaces while still leaving the solar-wind signal intact.

Kuhlman, K. R.↗

Small Particulate Contamination Survey Of Genesis Flight Sample 61423

The Genesis mission collected solar wind and brought it back to Earth in order to provide precise knowledge of solar isotopic and elemental compositions. The ions in the solar wind stop in the collectors at depths on the order of 10 to a few hundred nanometers. This shallow implantation layer is critical for scientific analysis of the composition of the solar wind and must be preserved throughout sample handling, cleaning, processing, distribution, preparation and analysis. We continue to work with the community of scientists analyzing Genesis samples using our unique laboratory facilities -- and, where needed, our unique cleaning techniques -- to significantly enhance the science return from the Genesis mission. This work is motivated by the need to understand the submicron contamination on the collectors in the Genesis payload as recovered from the crash site in the Utah desert, and -- perhaps more importantly -- how to remove it. We continue to evaluate the effectiveness of the wet-chemical "cleaning" steps used by various investigators, to enable them to design improved methods of stripping spacecraft and terrestrial contamination from surfaces while still leaving the solar-wind signal intact.

Kuhlman, K. R.↗

Toward Automated Plasma Focus Ion Beam Instrument Calibration for Materials Processing [Poster]

To accelerate the transition to autonomous focused ion beam (FIB) microscopy, we require an objective figure of merit (FOM) for assessing calibration. For our purposes, these FOMs related to beam astigmatism, quad, and focus. Intelligent calibration integrated into scripted workflows will enable fully automated sample preparation workflows that produce higher quality samples with less operator time.

97 MATHEMATICS AND COMPUTING↗