Search NASA⌕ Search

SEARCH · Search NASA

Results for “Scanning hard X-ray microscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

59 records · Page 4

Methods—Kintsugi Imaging of Battery Electrodes: Distinguishing Pores from the Carbon Binder Domain using Pt Deposition

The mesostructure of porous electrodes used in lithium-ion batteries strongly influences cell performance. Accurate imaging of the distribution of phases in these electrodes would allow this relationship to be better understood through simulation. However, imaging the nanoscale features in these components is challenging. While scanning electron microscopy is able to achieve the required resolution, it has well established difficulties imaging porous media. This is because the flat imaging planes prepared using focused ion beam milling will intersect with the pores, which makes the images hard to interpret as the inside walls of the pores are observed. It is common to infiltrate porous media with resin prior to imaging to help resolve this issue, but both the nanoscale porosity and the chemical similarity of the resins to the battery materials undermine the utility of this approach for most electrodes. In this study, a technique is demonstrated which uses in situ infiltration of platinum to fill the pores and thus enhance their contrast during imaging. Reminiscent of the Japanese art of repairing cracked ceramics with precious metals, this technique is referred to as the kintsugi method. The images resulting from applying this technique to a conventional porous cathode are presented and then segmented using a multi-channel convolutional method. We show that while some cracks in active material particles were empty, others appear to be filled (perhaps with the carbon binder phase), which will have implications for the rate performance of the cell. Energy dispersive X-ray spectroscopy was used to validate the distribution of phases resulting from image analysis, which also suggested a graded distribution of the binder relative to the carbon additive. The equipment required to use the kintsugi method is commonly available in major research facilities and so we hope that this method will be rapidly adopted to improve the imaging of electrode materials and porous media in general.

25 ENERGY STORAGE↗

High-Throughput Microstructural Characterization and Process Correlation Using Automated Electron Backscatter Diffraction

The need to optimize the processing conditions of additively manufactured (AM) metals and alloys has driven advances in throughput capabilities for material property measurements such as tensile strength or hardness. High-throughput (HT) characterization of AM metal microstructure has fallen significantly behind the pace of property measurements due to intrinsic bottlenecks associated with the artisan and labor-intensive preparation methods required to produce highly polished surfaces. This inequality in data throughput has led to a reliance on heuristics to connect process to structure or structure to properties for AM structural materials. In this study, we show a transformative approach to achieve laser powder bed fusion (LPBF) printing, HT preparation using dry electropolishing and HT electron backscatter diffraction (EBSD). This approach was used to construct a library of > 600 experimental EBSD sample sets spanning a diverse range of LPBF process conditions for AM Kovar. This vast library is far more expansive in parameter space than most state-of-the-art studies, yet it required only approximately 10 labor hours to acquire. Build geometries, surface preparation methods, and microscopy details, as well as the entire library of >600 EBSD data sets over the two sample design versions, have been shared with intent for the materials community to leverage the data and further advance the approach. Using this library, we investigated process–structure relationships and uncovered an unexpected, strong dependence of microstructure on location within the build, when varied, using otherwise identical laser parameters.

Characterization and Analytical Technique↗

Revisiting Discharge Mechanism of CF x as a High Energy Density Cathode Material for Lithium Primary Battery

Lithium/fluorinated graphite (Li/CFx) primary batteries show great promise for applications in a wide range of energy storage systems due to their high energy density (>2100 Wh kg –1 ) and low self-discharge rate (<0.5% per year at 25 °C). While the electrochemical performance of the CF x cathode is indeed promising, the discharge reaction mechanism is not thoroughly understood to date. In this article, a multiscale investigation of the CF x discharge mechanism is performed using a novel cathode structure to minimize the carbon and fluorine additives for precise cathode characterizations. Titration gas chromatography, X-ray diffraction, Raman spectroscopy, X-ray photoelectron spectroscopy, scanning electron microscopy, cross-sectional focused ion beam, high-resolution transmission electron microscopy, and scanning transmission electron microscopy with electron energy loss spectroscopy are utilized to investigate this system. Results show no metallic lithium deposition or intercalation during the discharge reaction. Crystalline lithium fluoride particles uniformly distributed with <10 nm sizes into the CF x layers, and carbon with lower sp2 content similar to the hard-carbon structure are the products during discharge. This article deepens the understanding of CF x as a high energy density cathode material and highlights the need for future investigations on primary battery materials to advance performance.

25 ENERGY STORAGE↗

Effect of autogenous shrinkage on microcracking and mass transport properties of concrete containing supplementary cementitious materials

It is well-known that supplementary cementitious materials (SCMs) and low water-to-binder (w/b) ratio increase autogenous shrinkage, but the impact on microcracking and long-term transport properties is less understood. This paper examines the effect of microcracking induced by autogenous shrinkage on transport properties of concretes cured up to ~3.6 years. Variables include SCM type (9% SF, 70% GGBS), w/b ratio (0.20–0.45), maximum-aggregate-size (MSA: 5–20 mm) and shrinkage reducing admixture (SRA). Oxygen diffusivity, permeability and water sorptivity were correlated with microcracks characterised using laser scanning confocal microscopy and 3D X-ray microtomography. Results show greater microcracking in mixes containing SCMs, low w/b ratio and large MSA. At the same w/b ratio and binder type, strong positive correlations are observed between transport and microcracking with increasing MSA, confirming the negative impact of autogenous shrinkage. SRA was effective in reducing these effects. The significance is compared with drying shrinkage and implications for durability are discussed.

36 MATERIALS SCIENCE↗

Assessment of Blocking Contacts in Suppressing Polarization Effects in CsPbBr 3 Perovskite Detectors

The CsPbBr 3 perovskite has garnered significant attention as a room-temperature semiconductor for hard radiation detection due to straightforward synthesis, scalable crystal growth, low cost, and excellent energy resolution. However, despite these advantages, at ambient temperature, CsPbBr 3 devices may experience performance deterioration and irreversible failure due to “polarization” induced by electromigration of ions to electrical connections on the device. In this study, we tested several contact materials and their optimization deposition techniques to assess the stability of high-performance CsPbBr 3 γ-ray detectors. Metals, with low work functions (Ti, In, Sn, Sb, Pb, Bi, Al, Au, and TiC) and high-work-function (Au or Pt) contacts, were used to form different Schottky junctions using vacuum thermal evaporation, electron-beam evaporation, and sputtering methods. These detectors were tested in intermittent and continuous modes to assess their stability. Among the tested detectors, the Bi/CLB/Pt electrode configuration demonstrated superior stability, operating effectively for 11 months under periodic testing and 16 days under continuous testing. In contrast, other configurations functioned only for a few months under intermittent conditions. Upon incorporating a ~40-nm-thick TiC passivation layer on the anode side (Bi/TiC/CLB/Pt), the CLB device operated continuously for 36 days without degradation. In many cases, the failure mode of the devices was due to the degradation of the anode. Here, the chemical changes in the fresh and deteriorated anodes were characterized using scanning electron microscopy and energydispersive X-ray spectroscopy

CsPbBr3 perovskite↗