Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sensor Integration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Intelligent Sensors: An Integrated Systems Approach

The need for intelligent sensors as a critical component for Integrated System Health Management (ISHM) is fairly well recognized by now. Even the definition of what constitutes an intelligent sensor (or smart sensor) is well documented and stems from an intuitive desire to get the best quality measurement data that forms the basis of any complex health monitoring and/or management system. If the sensors, i.e. the elements closest to the measurand, are unreliable then the whole system works with a tremendous handicap. Hence, there has always been a desire to distribute intelligence down to the sensor level, and give it the ability to assess its own health thereby improving the confidence in the quality of the data at all times. This paper proposes the development of intelligent sensors as an integrated systems approach, i.e. one treats the sensors as a complete system with its own sensing hardware (the traditional sensor), A/D converters, processing and storage capabilities, software drivers, self-assessment algorithms, communication protocols and evolutionary methodologies that allow them to get better with time. Under a project being undertaken at the NASA Stennis Space Center, an integrated framework is being developed for the intelligent monitoring of smart elements. These smart elements can be sensors, actuators or other devices. The immediate application is the monitoring of the rocket test stands, but the technology should be generally applicable to the Intelligent Systems Health Monitoring (ISHM) vision. This paper outlines some fundamental issues in the development of intelligent sensors under the following two categories: Physical Intelligent Sensors (PIS) and Virtual Intelligent Sensors (VIS).

Mahajan, Ajay↗

Integration of sensors through additive manufacturing leading to increased efficiencies of gas turbines for power generation and propulsion

To realize the full capability of additively manufactured components in complex energy systems, it is imperative to minimize early component failures during development phases and during operation. Traditional field feedback timelines and offline inspection protocols significantly reduce the design-manufacturing iteration times. To address this specific question, the project developed and demonstrated a method for the integration of sensors into complex components through additive manufacturing. The team used gas turbine engines as a platform, which meets the need of both power generation and propulsion and offer opportunities for cost reductions and efficiency increases. The innovation of this intelligent integration of sensors into complex components uniquely customized to address questions of integrity and durability for additively manufactured components. With real-time sensing data from additively manufactured components, turbine manufacturers will realize higher efficiencies, reduced component failures, and a 30-50% acceleration in product deployment of high efficiency gas turbine components due to a faster reduction in component risk assessment under actual operating conditions. This is a transformative shift towards a data-driven design and qualification of additively manufactured gas turbine components. To directly integrate sensors into additively manufactured components with all the complexities of actual hardware, powder bed fusion (direct metal laser sintering) and laser metal deposition technologies was developed. Validation took take place in two university laboratories both of which contain actual engine hardware and closely simulate a gas turbine prior to demonstrating the technology in a turbine development test. Indeed, two major technologies from this research cold impact turbine systems in the near future: (1) higher efficiency materials and designs enabled by additive manufacturing with 50% faster design to manufacturing cycle time, to enable faster time-to-market targets; and (2) integration of sensors into additively manufactured components enabling broad health and condition based prognostics for faster component and engine risk reduction.

33 ADVANCED PROPULSION SYSTEMS↗

Waveband Integrated Bioaerosol Sensor (WIBS4) for MARCUS Field Campaign Report

The Waveband Integrated Bioaerosol Sensor Mk. 4 (WIBS4) of Karlsruhe Institute of Technology (KIT) was operated as part of the Measurements of Aerosols, Radiation, and Clouds over the Southern Ocean (MARCUS) field campaign from November 2017 to March 2018. WIBS4 was integrated in the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility second ARM Mobile Facility (AMF2), which was installed on the RSV Aurora Australis Australian Antarctic supply vessel during MARCUS. The aim of this campaign was to characterize the Southern Ocean boundary layer coarse-mode aerosol in terms of the fraction of biological or biogenic compounds. This work was done in close collaboration with Greg McFarquhar from the University of Oklahoma, the principal investigator (PI) for MARCUS, as well as Paul DeMott from Colorado State University, who concurrently sampled particle filters for off-line analysis of the ice nucleating particle concentrations. During four voyages of the vessel between Hobart, Tasmania and the Australian Antarctic stations Davies, Casey, and Mawson, as well as Macquarie Island, fluorescent biological aerosol particles (FBAP) were monitored by the WIBS4 in the size range from 0.5 to 10 μm. A FBAP is defined by its fluorescent behavior that gives simultaneous signals in the F1 (λexcitation=280nm, λemission=310- 400nm) and F3 (λexcitation=370nm, λemission=420-650nm) channels of the WIBS4 (Toprak and Schnaiter, 2013).

MARCUS field campaign, aerosols, Southern Ocean, A↗

Magnetic measurements using array of integrated Hall sensors on the CASTOR tokamak

We have performed the first tests of 'integrated' Hall sensors (IHSs) in a tokamak in-vessel environment. IHS combines the sensing element together with the complex electronic circuitry on a single small chip. The on-chip integrated circuits provide stabilization of the supply voltage, output amplification, noise suppression, and elimination of temperature dependencies. Eight IHSs of A1322LUA type produced by Allegro MicroSystems, Inc. were mounted on a stainless steel ring symmetrically encircling the CASTOR plasmas in poloidal direction 10 mm outside the limiter radius. IHSs were oriented such that they measure the horizontal and vertical magnetic fields. We found out that these sensors qualify for in-vessel use of small to middle sized fusion devices where the radiation is not an issue and the temperature below 150 deg. C can be guaranteed. The main advantages over the traditional pickup coils are the smaller size and more straightforward interpretation of output without the need of rather cumbersome integration and drift removal procedure associated with the use of inductive loops. We successfully exploited the sensors for determination of vertical plasma displacement on CASTOR. This new diagnostic helped us to shed more light into long term observed discrepancy on CASTOR between vertical plasma displacement as deduced by standard magnetic and by nonmagnetic diagnostics (Langmuir probes, bolometers)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

3D Integrated Sensing Solutions

We will present the proposed research project to develop 3D-integrated sensors using advanced manufacturing capability for novel sensors, heterogeneously integrated with energy efficient readout circuits. The lack of precision timing in particle tracking detectors and the absence of low power, high throughput communications solutions to read them out limits progress in multiple fields of fundamental science. The aim of the project is to develop technology to enable large-scale particle detectors with 3D-integrated ASIC designs to simultaneously achieve 10 μm position resolution and 10 ps precision timing, with low-power consumption and high throughput rates. This research program leverages the unique combination of facilities and cross-disciplinary expertise of scientists and engineers at SLAC, FNAL, and LLNL and industrial partners.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

EGR Control for Emisson Reduction Using Fast Response Sensors - Phase 1A

The overall objective of this project was to develop exhaust gas recirculation (EGR) control strategies using fast-response Particulate Matter (PM) sensors and NOx sensors to improve the quality of particulate and gaseous emissions from diesel engines. This project initially comprised three phases: (1) Phase IA - sensor requirements to meet PM sensor specifications, NOx sensor assessment, and initial model development for EGR control; (2) Phase IB - continue development on PM and NOx sensors, integrate the sensor signals into the control simulations, and finalize model development for control strategies; and (3) Phase II - validation testing of the control strategies. Only Phase 1A was funded by DOE and executed by Honeywell. The major objectives of Phase 1A of the project included: (1) Sensor validation and operation of fast-response PM and NOx sensors; (2) Control system modeling of low-pressure EGR controls, development of control strategies, and initial evaluation of these models and strategies for EGR control in diesel engines; (3) Sensor testing to understand applicability of fast-response PM sensors in determining loading rates of the particle trap; and (4) Model validation and sensor testing under steady-state and transient operational conditions of actual engines. In particular, specific objectives included demonstration of: (1) A PM sensor response time constant (T10 - T90) of better than 100 milliseconds (msec); (2) The ability to detect PM at concentrations from 0.2 to 2 Bosch smoke number (BSN) or equivalent; (3) PM sensor accuracy to within 20% BSN over the entire range of operation; and (4) PM sensor repeatability to within 10% over the PM entire sensor range equivalent to a BSN of 0.2 to 2.

33 ADVANCED PROPULSION SYSTEMS↗

Fiber optic sensors

A survey of the developments in the field of fiber optics sensor technology is presented along with a discussion of the advantages of optical measuring instruments as compared with electronic sensors. The two primary types of fiber optics sensors, specifically those with multiwave fibers and those with monowave fibers, are described. Examples of each major sensor type are presented and discussed. Multiwave detectors include external and internal fiber optics sensors. Among the monowave detectors are Mach-Zender interferometers, Michelson interferometers, Sagnac interferometers (optical gyroscopes), waveguide resonators, and polarimeter sensors. Integrated optical sensors and their application in spectroscopy are briefly discussed.

Hesse, J.↗

Electron tunneling infrared sensor module with integrated control circuitry

In an integrated electron tunneling sensor, an automatic tunneling control circuit varies a high voltage bias applied to the sensor deflection electrode in response to changes in sensor output to maintain the proper gap between the sensor tip and membrane. The control circuit ensures stable tunneling activity in the presence of large signals and other disturbances to the sensor. Output signals from the module may be derived from the amplified sensor output. The integrated sensor module is particularly well adapted for use in blood glucose measurement and monitoring system.

Boyadzhyan-Sevak, Vardkes V.↗

Determination of Aerothermal Environment and Ablator Material Response Using Inverse Methods

The Mars Science Laboratory (MSL) was protected during entry into the Martian atmosphere by a thermal protection system that used NASA’s Phenolic Impregnated Carbon Ablator (PICA). The heat shield of the probe was instrumented with the Mars Entry Descent and Landing Instrument (MEDLI) suite of sensors. MEDLI Integrated Sensor Plugs (MISP) included thermocouples that measured in-depth temperatures at various locations on the heatshield. The flight data has been used as a benchmark for validating ablation codes within NASA. This work seeks to refine the estimate of the material properties for the MSL heat shield and the aerothermal environment during Mars entry using estimation methods in DAKOTA on the temperature data obtained from MEDLI.

Thornton, John M.↗

Miniature Flow and Viscosity Sensors

Integration of flow sensing into microfluidic systems such as automated sample preparation and processing has seen limited applications due to the large cost and size of commercially available flow sensors. Nevertheless, flow sensing is a critical missing components for many high precision microfluidic applications. Los Alamos National Laboratory researchers have developed a miniature flow sensor technology based on a novel microfluidic method developed at the Laboratory. The method takes advantage of the fluid-structure interaction between the fluid and an elastic membrane to provide precision measurement. Depending on how it is integrated, it is also possible to use the technology to measure viscosity of the fluid. The flow sensor can work with a wide range of fluids.

47 OTHER INSTRUMENTATION↗

IMU integration into Sensor suite for Inspection of H-Canyon

The Purpose of this internship was to Integrate the sensor suite which will be mounted onto a robotic inspection tool used to survey the H-Canyon Air Exhaust (CAEX) tunnel the Savannah River Site. This sensor suite incorporates 3D-mapping of its surroundings, along with a 360 degree picture of its surroundings stitched in with the li-dar readings. Incorporation of the IMU would enable us to track the position of the robot inside the cave, such that the robot handlers can know where inside the exhaust tunnel the scans have been taken. The Inertial Measurement Unit (IMU) used had ROS compatibility, allowing for high leavel programming and ease of software modification. The sensor transmitted Data in the form of Acceleration. A good portion of the internship concerned the investigation of discrete integration techniques, such that we can acquire precise position information quickly.

47 OTHER INSTRUMENTATION↗

Insect-Inspired Optical-Flow Navigation Sensors

Integrated circuits that exploit optical flow to sense motions of computer mice on or near surfaces ( optical mouse chips ) are used as navigation sensors in a class of small flying robots now undergoing development for potential use in such applications as exploration, search, and surveillance. The basic principles of these robots were described briefly in Insect-Inspired Flight Control for Small Flying Robots (NPO-30545), NASA Tech Briefs, Vol. 29, No. 1 (January 2005), page 61. To recapitulate from the cited prior article: The concept of optical flow can be defined, loosely, as the use of texture in images as a source of motion cues. The flight-control and navigation systems of these robots are inspired largely by the designs and functions of the vision systems and brains of insects, which have been demonstrated to utilize optical flow (as detected by their eyes and brains) resulting from their own motions in the environment. Optical flow has been shown to be very effective as a means of avoiding obstacles and controlling speeds and altitudes in robotic navigation. Prior systems used in experiments on navigating by means of optical flow have involved the use of panoramic optics, high-resolution image sensors, and programmable imagedata- processing computers.

Thakoor, Sarita↗

Secure, Autonomous, Intelligent Controller for Integrating Distributed Sensor Webs

This paper describes the infrastructure and protocols necessary to enable near-real-time commanding, access to space-based assets, and the secure interoperation between sensor webs owned and controlled by various entities. Select terrestrial and aeronautics-base sensor webs will be used to demonstrate time-critical interoperability between integrated, intelligent sensor webs both terrestrial and between terrestrial and space-based assets. For this work, a Secure, Autonomous, Intelligent Controller and knowledge generation unit is implemented using Virtual Mission Operation Center technology.

Ivancic, William D.↗

Lightweight Integrated Optical Sensor for Atmospheric Measurements on Mobile Platforms

The goal of the Phase I program was to develop a novel open path sensor platform technology based on integration of semiconductor waveguides with efficient optoelectronic components on a monolithic platform. The successful Phase I effort resulted in demonstration of a novel optical resonator structure based on semiconductor high contrast gratings (HCGs) that will enable implementation of an ultra-compact, low-power gas sensor suitable for use on mobile platforms. Extensive numerical modeling was performed to design a device optimized for measuring CO2 at a wavelength for which a laser was available for proof of concept. Devices were fabricated and tested to match the target wavelength, angle, and operating temperature. This demonstration is the first implementation of HCGs at the wavelengths of interest and shows the flexibility of the proposed architecture for gas sensing applications. The measured cavity Q was lower than anticipated due to fabrication process challenges. The PSI and UC Berkeley team has identified solutions to these challenges and will produce optimized devices in a Phase II program where a prototype sensor will be fabricated and tested.

54 ENVIRONMENTAL SCIENCES↗

Integrated Tactile Sensor for Robots

Proposed large-scale integrated (LSI) circuit gives robots, partshandling machines, and remote-control devices sense of touch. LSI circuits, placed on contact surfaces of manipulators combine functions of transduction, computing and communicating. Beneath layer of pressure sensitive rubber, resistivity of which changes with pressure, electrodes furnish pressuredependent signal to computation elements. Electrodes and computation elements contained in silicon integrated-circuit wafer.

Raibert, M. H.↗

Wireless SAW Sensors Having Integrated Antennas

A wireless surface acoustic wave sensor includes a piezoelectric substrate, a surface acoustic wave device formed on the substrate, and an antenna formed on the substrate. In some embodiments, the antenna is formed on the surface of the substrate using one or more of photolithography, thin film processing, thick film processing, plating, and printing.

Gallagher, Mark↗

Enabling Experimental Evolution: Multi-Parameter Sensor System Integration into a Culture/Stressor Biofluidics System

Experimental evolution (EE) exposes microbial communities to ecological stressors, simulating dynamics up to near-extinction events. Combined with comparative sequencing and other molecular tools, such data can inform the genetic and other biological mechanisms underlying extremophile adaptation, and other observed effects. Automating this type of experiment using biofluidics can mitigate many traditional obstacles, including delays in assay results and environment adjustment and the need for many replicates. A first-generation device for automating EE procedures, the Automated Adaptive Directed Evolution Chamber (AADEC), was developed at NASA Ames. UV-C radiation was the stressor, an LED-photodiode array measured optical density, magnetic agitation and peristaltic pump systems ensured nutrient availability, and Arduino microcontrollers provided control. Escherichia coli in LB kanamycin media was used for testing and performance verification. A manual laboratory procedure with timed exposure to UV-C was performed to typify tolerance acquisition. Approximately a 106 factor increase in survival ratio was recorded over multiple iterations. Currently, a second-generation device is being developed integrating more real-time sensors: redox potential (ORP), indicating available/consumed metabolic energy; dissolved oxygen (DO), indicating aerobic/anaerobic growth; pH, indicating metabolic products; and electrical conductivity (EC), another indicator of metabolic products. The EC sensor system was constructed and calibrated in-house and matched commercial sensors in the required range. A Raspberry Pi computer automated the electrical system, allowing real-time data acquisition. The fluidics card was made of CNC-milled polycarbonate for biocompatibility. Each sensor parameter can also be used as a selection pressure alone or in combination with others to create extreme microbial environments. As a proof of concept, this work demonstrated sensor operation in one pair of growth-sensor chambers. It can be expanded to a multi-chamber system to enable inter-culture comparisons and multi-population studies. The prior Arduino system will be ported to the RPi system. Future stressors to be added include thermal, reactive oxygen species, and varying nutrient availability.

Govinda Raj, Chinmayee↗

Metal 3D Printing of Low-NOX Fuel Injectors with Integrated Temperature Sensors (Final Technical Report)

This technical report presents the exploration of design and prototyping of an Oxy-fuel injector with integrated temperature sensing capabilities using Additive Manufacturing (AM) technology. The AM process has proven itself as a viable method to fabricate complex shapes for custom-designed metallic components rapidly. The lack of assembly requirements and the virtually unlimited geometrical complexity renders the AM process particularly attractive for fabricating complex energy system components. The unique layer-by-layer fabrication technique allows the embedding of sensors within complex components early in the design process. Sensors can be embedded (without post-production component modifications) in AM-fabricated components through two distinct processes: Stop and Go or Post-Integration. The Stop and Go fabrication process allows sensor placement within a cavity during fabrication; where the process is allowed to continue upon sensor placement. Post-integration process supports selective build of customized compartments for sensors within the part. The Stop and Go process requires an extremely accurate re-alignment of the powder-bed during the restart process. Additionally, metallization and shorting of sensors due to a considerably high temperature of the AM process creates significant fabrication challenges and limit the types of sensors that can be embedded. The Post-Integration of sensors is a practical alternative for components that can be effectively designed and fabricated with pre-built complex sensor compartments without the need for post-production component modifications. The proposed effort aimed at exploring the fabrication of an oxy-fuel injector designed for high-pressure Oxy-Combustion applications (Combustor for Directly Heated Supercritical Power Cycle) with integrated temperature measurement capabilities using the AM technique. Since the current design methodology of injectors is based on conventional fabrication techniques (e.g., multi-step machining and welding processes), a new paradigm of design methodology needs to be developed for their adaptation in the AM fabrication process. One of the most challenging issues addressed in powder bed fusion is the removal of powder from internal channels/cavities as the powder to be removed has been lightly sintered during the fabrication process. In this research, a major task has been assigned to developing and evaluating powder removal techniques that will ultimately be used when removing sintered powder from cavities/channels used for sensor placement. Achieving thorough powder removal will permit the incorporation of intricate cavities, integrated fasteners, or other novel features to incorporate sensors into parts directly post-fabrication – allowing for the novel, AM-based design practices to be developed and employ for sensor integration. The designed injector was initially tested at atmospheric conditions to review its successful operation. The tests were carried out for different firing inputs; with a minimum of 55 kW and a maximum of 275 kW. Later tests were carried out for pressurized conditions between 82 kW to 275 kW firing input. A pressure of 16.35bar was observed in the combustion chamber pressure during the pressurized test of 275 kW firing input; test duration was 15 seconds. Integrated thermocouples within the injector provided temperature data for test operations. The data revealed during the atmospheric condition the injector temperature is almost unaffected by the combustion. However, during the pressurized condition, the injector temperature rapidly up to 205°C within 15 seconds; at a 275 kW firing input.

42 ENGINEERING↗