Search NASA⌕ Search

SEARCH · Search NASA

Results for “Stokes parameters”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Dynamic models of flux tubes in the interpretation of polarization measurements

Recent observations of Stokes parameter profiles indicate the presence of mass motions with large velocity gradients associated with small-scale magnetic elements. Dynamic models of flux tubes were used in order to interpret observations of unresolved elements. It is clear that the physical picture of the dynamic models will be quite different from the hydrostatic ones since there is a strong coupling between the magnetic and the velocity field. Polarization measurements have to be interpreted in terms of dynamic models. Two-D steady flow solutions in slender magnetic tubes have been worked out. It was found that the main properties of the intensity line profiles as well as the asymmetries of the V Stokes profiles can be explained best in terms of magnetic elements with moderate field strength.

Ribes-Nesme, E.↗

Aquarius Instrument and Salinity Retrieval

Aquarius has been designed to map the surface salinity field of the global ocean from space a parameter important for understanding ocean circulation and its relationship to climate and the global water cycle. Salinity is measured remotely from space by measuring the thermal emission from the ocean surface. This is done at the low frequency end of the microwave spectrum (e.g. 1.4 GHz) where the emission is sufficiently sensitive to changes in salinity to be detected with sophisticated radiometers. The goal is to monitor the seasonal and interannual variation of the large scale features of the surface salinity field in the open ocean by providing maps on a monthly basis with a spatial resolution of 150 km and an accuracy of 0.2 psu. These are challenging requirements that have led to some unique features of the instrument. These include: a) The addition of a co-located scatterometer to help provide a correction for roughness; b) The addition of a polarimetric channel (third Stokes parameter) to the radiometer to help correct for Faraday rotation; c) Asun-synchronous orbit with a 6 pm ascending equatorial crossing to minimize Faraday rotation and with the antennas looking away from the sun toward the nighttime side to minimize contamination by radiation from the sun; and d) An antenna designed to limit side lobes in the direction of rays from the sun. In addition, achieving the accuracy goal of 0.2 psu requires averaging over one month and to do this requires a highly stable radiometer. Aquarius has three separate radiometers that image in pushbroom fashion with the three antenna beams looking across track. The antenna is a 2.5-m diameter, offset parabolic reflector with three feed horns and the three beams are arranged to image with the boresight aligned to look across track, roughly perpendicular to the spacecraft heading and pointing away from the Sun. The three beams point at angles of theta = 25.8 deg., 33.8 deg. and 40.3 deg. with respect to the spacecraft nadir which correspond to local incidence angles at the surface of 28.7 deg., 37.8 deg. and 45.6 deg., respectively. The resolution of the three radiometer beams (axes of the 3dB ellipse) is: 76 x 94 km for the inner beam, 84 x 120 km for the middle beam to 96 x 156 km for the outer beam. Together they cover a swath of about 390 km. Aquarius will map the global ice-free ocean every 7-days from which monthly average composites will be derived. This will provide a snapshot of the mean field, as well as resolving the seasonal to interannual variations over the three-year baseline of the mission.

Le Vine, D. M.↗

Scalable Nanoimprint Manufacturing of Functional Multilayer Metasurface Devices

Optical metasurfaces, consisting of subwavelength-scale meta-atom arrays, hold great promise of overcoming the fundamental limitations of conventional optics. Due to their structural complexity, metasurfaces usually require high-resolution yet slow and expensive fabrication processes. Here, using a metasurface polarimetric imaging device as an example, the photonic structures and the Nanoimprint lithography (NIL) processes are designed, creating two separate NIL molds over a patterning area of > 20 mm2 with designed Moiré alignment markers by electron-beam writing, and further subsequently integrate silicon and aluminum metasurface structures on a chip. Uniquely, the silicon and aluminum metasurfaces are fabricated by using the nanolithography and 3D pattern-transfer capabilities of NIL, respectively, achieving nanometer-scale linewidth uniformity, sub-200 nm translational overlay accuracy, and <0.017 rotational alignment error while significantly reducing fabrication complexity and surface roughness. Here, the micro-sized multilayer metasurfaces have high circular polarization extinction ratios as large as ≈20 and ≈80 in blue and red wavelengths. Further, the metasurface chip-integrated CMOS imager demonstrates high accuracy in broad-band, full Stokes parameter analysis in the visible wavelength ranges and single-shot polarimetric imaging. This novel, NIL-based, multilayered nanomanufacturing approach is applicable to the scalable production of large-area functional structures for ultra-compact optic, electronic, and quantum devices.

36 MATERIALS SCIENCE↗

Angle-resolved polarimetry of hybrid perovskite emission for photonic technologies

Coupling between light and matter strongly depends on the polarization of the electromagnetic field and the nature of excitations in a material. As hybrid perovskites emerge as a promising class of materials for light-based technologies such as LEDs, LASERs, and photodetectors, it is critical to understand how their microstructure changes the intrinsic properties of the photon emission process. While the majority of optical studies have focused on the spectral content, quantum efficiency and lifetimes of emission in various hybrid perovskite thin films and nanostructures, few studies have investigated other properties of the emitted photons such as polarization and emission angle. Here, we use angle-resolved cathodoluminescence microscopy to access the full polarization state of photons emitted from large-grain hybrid perovskite films with spatial resolution well below the optical diffraction limit. In this work, mapping these Stokes parameters as a function of the angle at which the photons are emitted from the thin film surface, we reveal the effect of a grain boundary on the degree of polarization and angle at which the photons are emitted. Such studies of angle- and polarization-resolved emission at the single grain level are necessary for future development of perovskite-based flat optics, where effects of grain boundaries and interfaces need to be mitigated.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Planck 2018 results. VII. Isotropy and Statistics of the CMB

Analysis of the Planck 2018 data set indicates that the statistical properties of the cosmic microwave background (CMB) temperature anisotropies are in excellent agreement with previous studies using the 2013 and 2015 data releases. In particular, they are consistent with the Gaussian predictions of the ΛCDM cosmological model, yet also confirm the presence of several so-called “anomalies” on large angular scales. The novelty of the current study, however, lies in being a first attempt at a comprehensive analysis of the statistics of the polarization signal over all angular scales, using either maps of the Stokes parameters, Q and U , or the E -mode signal derived from these using a new methodology (which we describe in an appendix). Although remarkable progress has been made in reducing the systematic effects that contaminated the 2015 polarization maps on large angular scales, it is still the case that residual systematics (and our ability to simulate them) can limit some tests of non-Gaussianity and isotropy. However, a detailed set of null tests applied to the maps indicates that these issues do not dominate the analysis on intermediate and large angular scales (i.e., ℓ ≲ 400). In this regime, no unambiguous detections of cosmological non-Gaussianity, or of anomalies corresponding to those seen in temperature, are claimed. Notably, the stacking of CMB polarization signals centred on the positions of temperature hot and cold spots exhibits excellent agreement with the ΛCDM cosmological model, and also gives a clear indication of how Planck provides state-of-the-art measurements of CMB temperature and polarization on degree scales.

79 ASTRONOMY AND ASTROPHYSICS↗

Full-polarization millimeter wavelength variability of Sagittarius A * during the 2018 EHT campaign

Context. Sagittarius A* (Sgr A*), the supermassive black hole at the center of the Milky Way, provides a unique laboratory to study accretion dynamics and plasma processes near the event horizon. Aims. We investigated the variability and polarization properties of Sgr A* using ALMA observations during the 2018 Event Horizon Telescope campaign. Methods. We analyzed high-cadence full-polarization light curves from ALMA at millimeter wavelengths, performed time-series analysis, and investigated the temporal behavior during an X-ray flare observed by Chandra on 2018 April 24. The variability characteristics are compared with expectations from standard accretion flow models. Results. We find low variability in total intensity (σ/μ < 10%), but significantly higher variability in linear and circular polarization (∼30% and ∼50%, respectively). A time-series analysis reveals red-noise variability, with power spectral densities between −2 and −3 across all Stokes parameters. Polarized intensity shows stable intra-day timescales, while total intensity exhibits more variable timescales, suggesting distinct emission regions, with polarization likely arising from a coherent structure. On April 24, a statistically significant inter-band delay in polarized intensity coincides with a near-simultaneous X-ray and millimeter peak that deviates from the typical delayed flare scenario. This event also features enhanced millimeter variability and coherent polarization loop evolution. The observed simultaneity challenges standard models of transient synchrotron emission with cooling delays, favoring instead a scenario of continuous energy injection in an optically thin region. Conclusions. Our results offer new constraints on the physical mechanisms driving variability in Sgr A*, and provide key observational input for refining theoretical models of accretion and plasma behavior in the vicinity of supermassive black holes.

Galaxy: center↗

Spectrally resolved polarization angle across the motional Stark effect spectrum

A new diagnostic technique has been developed that couples a spectrometer and an image-intensified camera into the traditional motional Stark effect (MSE) system on DIII-D. The image-intensified camera syncs with the photo-elastic modulators to spectrally resolve the Stokes parameters across the Stark multiplet. Polarization dependent phase shift, likely from a plasma facing mirror, leads to the spectropolarimeter measuring a variation in the polarization angle across the MSE spectrum of ∼8°.

Victor, B. S. (ORCID:0000000212512922)↗

Polarization formalism for ALP-induced X-ray emission from magnetars

Missions like NASA's Imaging X-ray Polarimetry Explorer (IXPE) are poised to provide an unprecedented view of the Universe in polarized X-rays. Polarization probes physical anisotropies, a fact exploited by particle physicists to look for the anisotropic a E∙B operator in the axion-like-particle (ALP) Lagrangian. Such studies have typically focused on polarization in the radio and microwaves, through local or cosmic birefringence effects. To such polarization studies we add X-rays emanating from magnetars — a class of neutron stars with near-critical strength magnetic fields — that are important targets for IXPE. ALPs produced in the neutron star core convert to X-rays in the magnetosphere; such X-rays are polarized along the direction parallel to the dipolar magnetic field at the point of conversion. Here, we develop the full theoretical formalism for ALP-induced polarization in the presence of dipolar magnetic fields. For uncorrelated photon and ALP production mechanisms, we completely disentangle the ALP contributions to the Stokes parameters in terms of the ALP intensity, the ALP-to-photon conversion probability, and the ALP-induced birefringence. In the proper limit, our results demonstrate that the inclusion of ALPs suppresses the observed degree of circular polarization compared to its pure astrophysical value. Our results can also be used to impose limits on ALP couplings with IXPE polarization data from magnetars 4U 0142+61 and 1RXS J170849.0-400910, the subject of upcoming work.

79 ASTRONOMY AND ASTROPHYSICS↗

Polarization measurements as a probe of axion-photon coupling: A study of GRB 221009A

Axionlike particles (ALPs) can be produced in gamma ray bursts, altering the polarization of the electromagnetic emission in these events. For the first time, we derive bounds on the axion-photon coupling from polarization measurements of GRB 221009A, performing a full calculation of the Stokes parameters, as it is typically done in the astrophysics community. Within astrophysical uncertainties, our limits on the axion-photon coupling are competitive with complementary probes in the axion mass range 10 −9 eV ≲ 𝑚 𝑎 ≲ 10 −8 eV, further allowing to probe motivated parameter space of ALP dark matter.

axion-like particles↗

Search for Axions in Magnetic White Dwarf Polarization at Lick and Keck Observatories

We present the most sensitive search to date for light axion-like particles with masses below a micro-eV, using spectropolarimetric data collected from the Lick and Keck Observatories. The conversion of optical photons emitted from the surface of a magnetic white dwarf (MWD) into axions in the strong magnetic field around the star induces a nearly wavelength-independent linear polarization in the observed starlight. We analyze the Stokes parameters $(U, Q, I)$ measured with the Kast spectrograph at the Lick Observatory toward the MWDs SDSS J033320+000720 and ZTF J190132+145807, and with the LRISp-ADC instrument at the Keck Observatory toward ZTF J190132+145807, SDSS J002129+150223, and SDSS J100356+053825 to search for this effect. The data show no evidence of axion-induced linear polarization, and we set world-leading constraints on the axion-photon coupling $|g_{aγγ}| \lesssim 1.7 \times 10^{-12} \,\mathrm{GeV}^{-1}$ at the $95\%$ confidence level for masses $m_a \lesssim 2 \times 10^{-7}\,\mathrm{eV}$.

FOS: Physical sciences↗

Solar system applications of Mie theory and of radiative transfer of polarized light

A theory of the multiple scattering of polarized light is discussed using the doubling method of van de Hulst. The concept of the Stokes parameters is derived and used to develop the form of the scattering phase matrix of a single particle. The diffuse reflection and transmission matrices of a single scattering plane parallel atmosphere are expressed as a function of the phase matrix, and the symmetry properties of these matrices are examined. Four matrices are required to describe scattering and transmission. The scattering matrix that results from the addition of two identical layers is derived. Using the doubling method, the scattering and transmission matrices of layers of arbitrary optical thickness can be derived. The doubling equations are then rewritten in terms of their Fourier components. Computation time is reduced since each Fourier component doubles independently. Computation time is also reduced through the use of symmetry properties.

Whitehill, L. P.↗

Gyrosynchrotron radiation and its transfer in a magnetoactive plasma.

Gyrosynchrotron radiation fields from mildly relativistic electrons in a magnetoactive plasma are asymptotically calculated by using the Green tensor and the Fourier transformation. These fields consist of the two components which correspond to the ordinary and extraordinary modes. Taking into account these fields, the emissivities and the absorption coefficients from an arbitrary distribution of electrons are calculated in order to discuss the intensity, spectrum, and polarization of gyrosynchrotron radiation. In general, the transfer of electromagnetic energy takes place along a direction different from that of the wave normal since the radiation fields have a nonvanishing component along the direction of the wave normal. A consideration is given on the problem of radiative transfer in relation to the Stokes parameters.

Sakurai, K.↗

Polarization of gravitational synchrotron radiation.

Development of a method of analysis of gravitational polarization in terms of Stokes parameters similar to those used for the electromagnetic case. Analytical expressions for these parameters are obtained for the gravitational synchrotron radiation corresponding to the Schwarzschild black-hole model. It is shown that interference between odd- and even-parity terms makes a significant contribution to the angular dependence of the polarization.

Breuer, R. A.↗

Interferometric spectropolarimetry - Alternate experimental methods.

Three alternate methods of obtaining spectra of the intensity and state of polarization of light are proposed. The methods make use of a two-beam amplitude division interferometer using the technique of Fourier spectroscopy. They do not require the presence of polarizers in the arms of the instrument. In one method a single analyzer is used in front of the detector with three successive orientations of its transmission axis azimuth. In another method, a (linear) polarizer assuming the same set of orientations is placed in the incident beam. A third method, a hybrid of the former two methods, makes use of both a polarizer and analyzer in the locations indicated. The first method permits the determination of all four Stokes parameters of polarization, whereas the other two methods cannot yield the ellipticity parameter. All methods require the recording of three interferograms. However, two interferograms can provide the intensity and degree of polarization in any of the methods described.

Fymat, A. L.↗

Investigation of Atmospheric Effects in Image Transfer

Several computations on radiation emerging from the atmosphere for different aerosol models have been performed and the reflection matrix of a given surface was defined by incident light signature analyses. A two channel polarimeter is being constructed for measuring the Stokes parameters of reflected light. Surface albedo measurements were made in six wavelength ranges in the ultraviolet, visible, and near infrared spectral regions for six different vegetated surfaces, four soil surfaces, and two roadway surfaces. The effects of polarization changes on the intensity of projected images were studied by using a rotatable polarizer in front of an aerial camera lens.

Coulson, K. L.↗

Principles and techniques of polarimetric mapping.

This paper introduces the concept and potential value of polarimetric maps and the techniques for generating these maps in operational remote sensing. The application-oriented polarimetric signature analyses in the literature are compiled, and several optical models are illustrated to bring out requirements of a sensor system for polarimetric mapping. By use of the concepts of Stokes parameters the descriptive specification of one sensor system is refined. The descriptive specification for a multichannel digital photometric-polarimetric mapper is based upon our experience with the present single channel device which includes the generation of polarimetric maps and pictures. High photometric accuracy and stability coupled with fast, accurate digital output has enabled us to overcome the handicap of taking sequential data from the same terrain.

Halajian, J.↗

Nomenclature of polarized light - Elliptical polarization

Alternative handedness and sign conventions for relating the orientation of elliptical polarization are discussed. The discussion proceeds under two headings: (1) snapshot picture, where the emphasis for the convention is contained in the concept of handedness; and (2) angular momentum consideration, where the emphasis for the convention is strongly associated with mathematical convention and the sign of the fourth Stokes parameter.

Clarke, D.↗