Search NASA⌕ Search

SEARCH · Search NASA

Results for “THERMOSTAT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Io - A volcanic flow model for the hot spot emission spectrum and a thermostatic mechanism

The hot spots of Io are modeled as a steady state of active areas at 600 K, continuing creation of new lava flows and calderas, cooling off of recent flows and calderas, and the cessation of radiation of old flows and calderas from the accumulation of insulation added by resurfacing. There are three adjustable parameters in this model: the area of active sources at 600 K, the rate of production of new area that is cooling, and the temperature of cessation of emission as the result of resurfacing. The resurfacing rate sets constrains on this last parameter. The emission spectrum computed with reasonable values for these parameters is an excellent match to the spectrum from recent observations. A thermostatic mechanism is described whereby the volcanic activity is turned on for a long period of time and is then turned off for a nearly equal period. As a result the presently observed internal heat flow of approximately 1.5 W/sq m may be as much as twice the rate of production of internal heat. Thus the restrictions placed on theories of tidal dissipation by the observed heat flow may be partially relieved.

Sinton, V. M.↗

An inquiry into the cirrus-cloud thermostat effect for tropical sea surface temperature

In this paper, we investigate the relative importance of local vs remote control on cloud radiative forcing using a cumulus ensemble model. It is found that cloud and surface radiation forcings are much more sensitive to the mean vertical motion assoicated with large scale tropical circulation than to the local SST (sea surface temperature). When the local SST is increased with the mean vertical motion held constant, increased surface latent and sensible heat flux associated with enhanced moisture recycling is found to be the primary mechanism for cooling the ocean surface. Large changes in surface shortwave fluxes are related to changes in cloudiness induced by changes in the large scale circulation. These results are consistent with a number of earlier empirical studies, which raised concerns regarding the validity of the cirrus-thermostat hypothesis (Ramanathan and Collins, 1991). It is argued that for a better understanding of cloud feedback, both local and remote controls need to be considered and that a cumulus ensemble model is a powerful tool that should be explored for such purpose.

Lau, K.-M.↗

Programmable Thermostat Module Upgrade for the Multi-Purpose Logistics Module

The STS-121/ULF1.1 mission was the maiden flight of the Programmable Thermostat Module (PTM) system used to control the 28 V shell heaters on the Multi-Purpose Logistics Module (MPLM). These PTMs, in conjunction with a Data Recorder Module (DRM), provide continuous closed loop temperature control and data recording of MPLM on-orbit heater operations. This paper will discuss the hardware design, development, test and verification (DDT&V) activities performed at the Marshall Space Flight Center (MSFC) as well as the operational implementation and mission performance.

Clark, Dallas↗

Programmable Thermostat Module Upgrade for the Multipurpose Logistics Module

The STS-121/ULF 1.1 mission was the maiden flight of the programmable thermostat module (PTM) system used to control the 28 V shell heaters on the multi-purpose logistics module (MPLM). These PTMs, in conjunction with a data recorder module (DRM), provide continuous closed loop temperature control and data recording of MPLM on-orbit heater operations. This Technical Memorandum discusses the hardware design, development, test, and verification (DDT&V) activities performed at the Marshall Space Flight Center as well as the operational implementation and mission performance.

Clark, D. W.↗

Thermostatic Valves Containing Silicone-Oil Actuators

Flow-splitting and flow-mixing thermally actuated spool valves have been developed for controlling flows of a heat-transfer fluid in a temperature-regulation system aboard the Mars Science Laboratory (MSL) rover. Valves like these could also be useful in terrestrial temperature-regulation systems, including automobile air-conditioning systems and general refrigeration systems. These valves are required to provide smoother actuation over a wider temperature range than the flow-splitting, thermally actuated spool valves used in the Mars Explorer Rover (MER). Also, whereas the MER valves are unstable (tending to oscillate) in certain transition temperature ranges, these valves are required not to oscillate. The MER valves are actuated by thermal expansion of a wax against spring-loaded piston rods (as in common automotive thermostats). The MSL valves contain similar actuators that utilize thermal expansion of a silicone oil, because silicone-oil actuators were found to afford greater and more nearly linear displacements, needed for smoother actuation, over the required wider temperature range. The MSL valves also feature improved spool designs that reflect greater understanding of fluid dynamics, consideration of pressure drops in valves, and a requirement for balancing of pressures in different flow branches.

Bhandari, Pradeep↗

Eastern Equatorial Pacific Warming Delayed By Aerosols and Thermostat Response to Co2 Increase

Understanding the tropical Pacific response to global warming remains challenging. Here, we use a range of CMIP6 greenhouse warming experiments to assess the recent and future evolution of the equatorial Pacific east-west temperature gradient and corresponding Walker circulation. In abrupt CO2-increase scenarios many models generate an initial strengthening of this gradient resembling an ocean thermostat (OT), followed by a small weakening; other models generate an immediate weakening that becomes progressively stronger establishing a pronounced eastern equatorial Pacific (EP) warming pattern. The initial response in these experiments is a strong predictor for the future EP pattern simulated in both abrupt and realistic warming scenarios, but not in historical simulations showing no multi-model trend. The likely explanation is that the recent CO2-driven changes in the tropical Pacific are masked by aerosol effects and a potential OT-related delay, while the EP warming pattern will emerge as greenhouse gases overcome aerosol forcing.

Climate and Earth system modelling↗

Coordination of thermostatically controlled loads

Apparatus and methods for a market-based control framework to coordinate a group of autonomous thermostatically controlled loads (TCL) to achieve system-level objectives with pricing incentives is disclosed. In one example of the disclosed technology, a method of providing power to a load via a power grid by submitting bids to a coordinator includes determining an energy response relating price data for one or more energy prices to quantity data for power to be consumed by the load, sending a bid for power for a finite time period based on the energy response to the coordinator, and receiving a clearing price based on: the bid, on bids received from a plurality of additional loads, and a feeder power constraint. In some examples, the energy response is based at least in part on an equivalent thermal parameter model and a control policy indicating one or more power states for the load.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Passive radiative thermostat

A passive radiative thermostat (PRT) is provided. The PRT comprises a phase-change part comprising a thermochromic phase change material; and a wavelength-selector part designed to create electromagnetic resonances in a wavelength range. The wavelength range may include the visible range, the near-infrared range, or the mid-infrared range. The wavelength-selector part may include an electromagnetic cavity resonator or an electromagnetic plasmonic resonator. Further, the phase-change part may include a thermochromic film; and the wavelength-selector part may include a dielectric spacer.

de Melo Kort-Kamp, Wilton Junior↗

System and method for characterization of air leakage in building using data from communicating thermostats and/or interval meters

Systems and methods for characterization of retrofit opportunities are described. Some embodiments are directed to methods for determining the air leakage rate of a building, and accordingly, for determining suitability of sealing of air leaks to improve the energy efficiency of a building. The methods may comprise computing, using at least one computing device disposed remote from a building and based at least in part on heating, ventilation and air conditioning (HVAC) runtime data associated with the building, one or more thermal characteristics of the building. The HVAC runtime data may be computed based on data received from a thermostat or a meter, such as an electric or a gas meter. To isolate the impact of air leakage, subsets of the HVAC runtime data at time intervals selected to have substantially the same conditions, but different wind speeds, may be computed.

Zeifman, Michael↗

Coordination of thermostatically controlled loads

Apparatus and methods for a market-based control framework to coordinate a group of autonomous thermostatically controlled loads (TCL) to achieve system-level objectives with pricing incentives is disclosed. In one example of the disclosed technology, a method of providing power to a load via a power grid by submitting bids to a coordinator includes determining an energy response relating price data for one or more energy prices to quantity data for power to be consumed by the load, sending a bid for power for a finite time period based on the energy response to the coordinator, and receiving a clearing price based on: the bid, on bids received from a plurality of additional loads, and a feeder power constraint. In some examples, the energy response is based at least in part on an equivalent thermal parameter model and a control policy indicating one or more power states for the load.

Lian, Jianming↗

Nonlinear behavior in high-frequency aggregate control of thermostatically controlled loads

Coordinated control of electric loads can provide valuable grid services, such as frequency regulation. However, due to the nonlinear characteristics of such load ensembles, it is important to systematically analyze their behavior and establish a thorough understanding of undesirable phenomena that can potentially arise. In this paper, we analyze the frequency response of an aggregate control scheme, with the goal of exploring controller performance limits. We show that rapid switching commands can induce oscillations in the power output due to the inherent lockout mechanism of the underlying devices. Here, we demonstrate that highly detailed aggregate models are required to capture such phenomena. Such models enable deeper understanding of the control boundaries and therefore play an important role in avoiding the introduction of undesirable effects on the grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Implications of a phase-transition thermostat for chondrule melting

It is widely accepted that chondrules were formed in brief, localized nebular heating episodes. Given the apparent (at least local) high efficiency of chondrule formation, these thermal events seem to have occurred at a large number of different times and/or azimuthal locations in the solar nebula. It is reasonable to expect that the chondrule-forming events, whatever their underlying cause, were not all identical, but instead occurred with some spread of heating intensities. If this was so, it is puzzling that compositional and textural evidence points to peak temperatures certainly within 1400 - 1750 C, and in most cases within 1500 - 1550 C. This problem is addressed in this article and a possible explanation for this restricted range of peak temperatures is discussed.

Love, S. G.↗